• Title/Summary/Keyword: load limits

Search Result 315, Processing Time 0.033 seconds

전압불평형율의 현장측정 및 분석 (Field Measurement and Analysis of Voltage Unbalance Factor)

  • 정종호;박영진;이은웅;김종겸
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.41-46
    • /
    • 2005
  • Most of LV customer have applied the 3-phase four wire system distribution system because it has advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But voltage unbalance more commonly emerges in individual customer loads due to phase load unbalance, especially where, single-phase power loads are used. Voltage unbalance factor(VUF) represents the loss of symmetry in the supply(magnitude and angle). It leads some problems such as de-rating or power losses. In this paper, voltage and current waveform in the actual fields have been measured and analyzed in relation with internationally allowable voltage unbalance limits.

3상 4선식 부하설비의 전압 불평형율 허용 기준 (Allowable Limits for Voltage Unbalance Factor of Three Phase Four Wire Load System)

  • 김종겸;박영진;정종호;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.51-56
    • /
    • 2006
  • 저압 수용가에 적용되고 있는 3상 4선식 배전방식은 단상 및 3상 부하를 동시에 이용할 수 있는 장점이 있는 반면 부하의 불평형 운전에 의한 임피던스의 변화로 전압 불평형이 발생하게 된다. 이들 부하 중에서는 선형 및 비선형 부하가 사용될 경우 고조파의 발생으로 부하에 나쁜 영향을 미칠 수 있다. 그래서 본 논문에서는 전압 불평형율의 허용범위를 제한하기 위해 전압 불평형율에 대한 측정방법, 불평형율의 계산방법 그리고 현장 측정 등을 통해 도출된 결과들을 분석하여 가장 효과적인 허용범위를 제안하였다.

  • PDF

경부고속철도 시험선 구간에서 G7 고속전철 차량의 동특성 검토 (Review on the Dynamic Behavior of G7 High Speed Train(KHST) in the KTX Test Line)

  • 박찬경;김영국;배대성;박태원
    • 한국철도학회논문집
    • /
    • 제4권4호
    • /
    • pp.131-137
    • /
    • 2001
  • The dynamic behavior of high speed train is very important because of its safety and passengers' ride comfort. The railway vehicle is composed of many suspension components, such as 1st springs, 1st dampers, 2nd springs and 2nd dampers, that have an influence on the dynamic characteristics of high speed train. Also, the wheel/rail shapes and the track geometry affect the dynamic behavior of high speed train. This paper reviews the dynamic behavior of KHST in the KTX test line. The VAMPIRE program is used for this simulation. The simulation results are within the limits of safety criteria. Thus the KHST can operate safely at 350 km/h in the KTX test line.

  • PDF

IIR 필터를 기저로 이용한 능동소음제어 알고리즘의 설계 기법 (Design of the ANC algorithm using IIR filter bases)

  • 오시환;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.445-448
    • /
    • 1996
  • For a lightly damped system, IIR based filter can have better performance than FIR filter as an adaptive filter in ANC algorithm. IIR based filter which has an infinite impulse response can model a lightly damped acoustic system with a small number of weights compared that of FIR filter and has no nonlinearity and instability problems on weight updating process which are associated to the conventional IIR filters. There are, however, some drawbacks such as design parameters to be determined earlier to get better performance and much increased computational power especially in the presence of error path. In this study, base filter parameters are determined in systematic manner, with the knowledge of the nominal impulse response of the system which should be identified, by Prony's method. Three methods reducing the computational load are proposed and their performance and application limits are discussed. Simulation and experimental results demonstrate the feasibility of the proposed method.

  • PDF

FATIGUE RESISTANCE OF DENTAL IMPLANTS TREATED WITH LASER METHOD

  • Park, Eun-Young
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.734-739
    • /
    • 2006
  • Statement of problem. Many surface processing methods of dental implant have been developed, the laser processing is one of them. Purpose. This study was to investigate in vitro the fatigue resistance of implants treated with laser method(CSM implant, CSM Company, Daegu, Korea). Material and methods. Fatigue tests of 23 laser treated CSM implant(CSM Company, Daegu, Korea) were conducted using Instron 8871 (Load cell, 5 kN, Instron Co., England), according to ISO 14801 (2003), Results. From 300 N, each specimens were not fractured and withstood until more than 5,000,000 cycle. Conclusion. Within the limits of this in vitro study, implants treated with laser method (CSM implant, CSM Company, Daegu, Korea) have had enough rigidity and fatigue resistance to use clinically with reliance.

신뢰도 지수를 고려한 배전계통의 최적 전력전송경로 결정 (Optimal Routing of Distribution Network Considering Reliability Indices)

  • 신동환;노병권;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권9호
    • /
    • pp.1073-1080
    • /
    • 1999
  • Optimal routing of distribution networks can be attained by keeping the line power capacity limit to handle load requirements, acceptable voltage at customer loads, and the reliability indices such as SAIFI, SAIDI, CAIDI, and ASAI limits. This method is composed of optimal loss reduction and optimal reliability cost reduction. The former is solved relating to the conductor resistance of all alternative routes, and the latter is solved relating to the failure rate and duration of each alternative route. The routing considering optimal loss only and both optimal loss and optimal reliability cost are compared in this paper. The case studies with 10 and 24 bus distribution networks showed that reliability cost should be considered as well as loss reduction to achieve the optimal routing in the distribution networks.

  • PDF

공진조건을 이용한 미소신호 안정도 해석 (Analysis of Small Signal Stability Using Resonance Conditions)

  • 조성진;장길수;윤태웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.535-543
    • /
    • 2002
  • Modern power grids are becoming more and more stressed with the load demands increasing continually. Therefore large stressed power systems exhibit complicated dynamic behavior when subjected to small disturbance. Especially, it is needed to analyze special conditions which make small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability and operating conditions can be identified well using node-focus point and 1:1 resonance point. Also, the weak point which limits operating range is found by the analysis of resonance condition, and it is shown that reactive power compensation may solve the problem in the weak points. The proposed method is applied to test systems, and the results illustrate its capabilities.

보이드 성장을 고려한 재료의 성형한계에 대한 비 국소 해석 (Non-Local Analysis of Forming Limits of Ductile Material Considering Damage Growth)

  • 김영석;원성연
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.914-922
    • /
    • 2003
  • In this paper, the strain localization of voided ductile material has been analyzed by nonlocal plasticity formulation in which the yield strength not only depends on an equivalent plastic strain measure (hardening parameter), but also on the Laplacian thereof. The gradient terms in yield criterion show an important role on modeling strain-softening phenomena of material. The influence of the mesh size on the elastic -plastic deformation behavior and the effect of the characteristic length parameter for localization prediction are also investigated. The proposed nonlocal plasticity shows that the load -strain curves converge to one curve. Results using nonlocal plasticity also exhibit the dependence of mesh size is much less sensitivity than that for a corresponding local plasticity formulation.

A New Flame-Stabilization Technology for Lean Mixtures

  • Kim, Duck-Jool;Choi, Gyung-Min
    • Journal of Mechanical Science and Technology
    • /
    • 제14권4호
    • /
    • pp.426-432
    • /
    • 2000
  • The development of a low-pollution burner is important for saving energy and preserving the environment. A low-pollution burner can be produced by lean-mixture combustion and general combustion technology. The flammable limit of premixed flame is narrower than that of diffusion flame. Producing a lean mixture of fuel results in an effective combustion condition, which in turn produces high load and low pollution. In this study, it was found that the influx of $Q_2$ had an effect on extending the lean flammable limits and flame stabilization in a doubled jet burner. And the flame, consisting of small eddies, can be stabilized by the nozzle neck phenomena.

  • PDF

지진하중을 받는 원자력발전소용 냉각펌프의 내진해석 (Seismic Analysis of the Cooling Water Pump for Nuclear Power Plant for the Seismic Load)

  • 정철섭
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1239-1243
    • /
    • 2009
  • To evaluate the structural integrity of the nuclear seismic category penetration cooling water pump under the seismic service conditions the seismic analysis was performed in accordance with IEEE-STD-344 code. The finite element computer program, ANSYS, Version 10.0, is used to perform both a mode frequency analysis and an equivalent static seismic analysis of the pump assembly. The mode frequency analysis results show the fundamental natural frequency is greater than 33 Hz and does not exist in seismic range, thus justifying the use of the static analysis. The stresses resulted from various loadings and their combinations are within the allowable limits specified in the above mentioned IEEE code. The results of the seismic evaluation fully satisfied the structural acceptance criteria of the IEEE code. Accordingly the structural integrity on the pump assembly was proved.