• Title/Summary/Keyword: load balance

Search Result 569, Processing Time 0.031 seconds

A Study on the Intelligent Load Management System Based on Queue with Diffusion Markov Process Model (확산 Markov 프로세스 모델을 이용한 Queueing System 기반 지능 부하관리에 관한 연구)

  • Kim, Kyung-Dong;Kim, Seok-Hyun;Lee, Seung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.891-897
    • /
    • 2009
  • This paper presents a novel load management technique that can lower the peak demand caused by package airconditioner loads in large apartment complex. An intelligent hierarchical load management system composed of a Central Intelligent Management System(CIMS) and multiple Local Intelligent Management Systems(LIMS) is proposed to implement the proposed technique. Once the required amount of the power reduction is set, CIMS issues tokens, which can be used by each LIMS as a right to turn on the airconditioner. CIMS creates and maintains a queue for fair and proper allocation of the tokens among the LIMS requesting tokens. By adjusting the number tokens and queue management policies, desired power reduction can be achieved smoothly. The Markov Birth and Death process and the Balance Equations utilizing the Diffusion Model are employed for evaluation of queue performances during transient periods until the static balances among the states are achieved. The proposed technique is tested using a summer load data of a large apartment complex and give promising results demonstrating the usability in load management while minimizing the customer inconveniences.

Design and Implementation of Multi-Agent System for Load Shedding in Microgrid (마이크로그리드 환경에서 부하차단을 위한 다중 에이전트 시스템의 설계 및 구현)

  • Lim, Yujin;Kim, Hak-Man
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.125-132
    • /
    • 2012
  • In an islanded operation mode of a microgrid, load shedding is used to balance between the power supplied and the power demanded. The conventional load-shedding schemes have considered that a load uses a continuous range of values to present its load demand. However, in reality, some loads use integer and discrete values. We design a multi-agent system for the load shedding with consideration of the discrete characteristic of load demands. Besides, we define a control architecture, functionalities of agents, and interactions among agents for implementation of the system. Through experiments in various test scenarios, we show the feasibility and performance of the system.

Nutrient Balance in the Paddy Fields Watershed with a Source of River Water (하천관개지역 광역논에서의 영양물질의 물질수지)

  • Lee, Jeong Beom;Lee, Jae Yong;Li, Si Hong;Jang, Jeong Ryeol;Jang, Ik Geun;Kim, Jin Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.11-19
    • /
    • 2014
  • The objective of this research was to investigate concentration and load of nutrients such as total nitrogen (TN), nitrate nitrogen ($NO_3$-N) total phosphorous (TP), and phosphate phosphorous ($PO_4$-P) in a 23.4-ha paddy fields watershed with river water source. Water samples for irrigation water, drainage water, ponded water and groundwater were collected, and irrigation and drainage water were measured at 5~10 day intervals during normal days and at 2~6 hours intervals during three storm events. The amount of irrigation water in the study area was over 2,000 mm, which is almost identical to that in the area irrigated from a large reservoir but much more than that in the area irrigated from a pumping station. Mean flow-weighted concentrations of TN and TP in irrigation water were 2.8 and 0.15 mg/L, respectively, higher than those in the area irrigated from a large reservoir or a pumping station. The ratios of irrigation load to total inflow load for TN and TP were 88 %, and the ratios of surface outflow load to total outflow load for TN and TP were over 90 %, indicating that total nutrient load may be greatly affected by water management. The nutrient loads per area in the study area were estimated as TN 21.1 kg/ha and TP 1.1 kg/ha. Especially, the TP load per area in the study area was smaller than that in the area irrigated from a large reservoir or a pumping station. This may be because outflow load is not high likely due to sedimentation of particulate P and irrigation water load is high due to high TP concentration in irrigation water and high amount of irrigation water.

A study of balance between work and family, and of happiness: focused on working women with preschool-aged children (일-가정 균형감과 행복도 : 영유아기 자녀를 둔 기혼취업여성을 중심으로)

  • SONG, Hyerim
    • Journal of Family Resource Management and Policy Review
    • /
    • v.19 no.3
    • /
    • pp.81-99
    • /
    • 2015
  • This study investigates the balance between work and family, and the happiness of married working women who have preschool-aged children. Data were collected from 321 questionnaires that consisted of three parts: 1) basic demographic variables, 2) family-life variables, and 3) working-life variables. SPSS 21.0 was used for the statistical analysis. The variables that were identified to have a statistically significant impact on the balance between work and family were income, age of first child, time spent on housework and childcare on weekdays, time spent on housework on weekends, family-friendly service in the workplace and flexibility of work schedule. 2) The variables that were identified to have a statistically significant impact on happiness were age, income, time spent on housework on weekends, satisfaction with spouse's participation in housework and childcare, average working time, family-fiendly service in the workplace, flexibility of work schedule, and balance between work and family. The majority of the variables that influence balance between work and family, and happiness related to aspects of work, such as family-fiendly service, flexibility of work schedules, and average working time. The results also found that the load of housework and childcare on weekends is a heavy burden for working women. Further research needs to focus on developing the extending index of happiness including the measure of balance between work and life. In addition, further studies with more varied groups need to be conducted.

Study for Loading Characteristic of Tilting Mechanism on Korea Tilting Train (II) - Adjustmemt for Interface of carbody and Bogie (한국형틸팅열차 틸팅기구장치 부하특성 평가 연구(II) - 대차/차체 인터페이스 조정에 의한 정적부하 영향분석)

  • Ko, Tae-Hwan;Lee, Wang-Sang;Lee, Bum-Sang
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.951-956
    • /
    • 2011
  • As the evaluation of loading characteristic on tilting mechanism is the most important one of the function test of tilting mechanism, the changing characteristic of load must be investigated on tilting of carbody for both the static and running condition of train. In this study, we reduced the load of tilting mechanism by adjusting the interface of carbody and bogie such as the weight balance, level of underframe, height of leveling valve, height of axle box and center position of tilting actuator with the characteristic curve of load for optimal condition of the tilting mechanism obtained in the previous study. Furthermore, the factor and effect of the interfacial structures respecting the load of tilting mechanism was evaluated by analyzing the changing characteristic of load obtained in the process of adjustment of interfaces. From these data, we will propose the maintenance standards for interfacial structures and tilting mechanism in order to minimize the load of tilting mechanism by analyzing in detail the characteristic of load for the main factors of the interfacial structure effecting on the load of tilting mechanism.

  • PDF

A lateral load pattern based on energy evaluation for eccentrically braced frames

  • Fakhraddini, Ali;Fadaee, Mohammad Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • v.27 no.5
    • /
    • pp.623-632
    • /
    • 2018
  • Performance-Based Plastic Design (PBPD) method has been recently developed to evaluate the behavior of structures in different performance levels. The PBPD method utilizes a base shear force and a lateral load pattern that are estimated based on energy and yielding mechanism concepts. Using of current lateral force pattern results in weak structural members in upper stories of a structure so that the values of the story drift in these stories are larger than the target drift, particularly in high-rise buildings. Therefore, such distribution requires modifications to overcome this drawback. This paper proposes a modified lateral load pattern for steel Eccentrically Braced Frames (EBFs) based on parametric study. In order to achieve the modified load pattern, a group of 26 EBFs has been analyzed under a set of 20 earthquake ground motions. Additionally, results of nonlinear dynamic analyses of EBFs have been post-processed by nonlinear regression analysis in order to derive the new load pattern. To prove the efficiency of present study, three EBFs as examples were designed by modified pattern and current PBPD distribution. Inelastic dynamic analyses results showed that the story drifts using modified lateral load pattern were well within the target values in comparison with current pattern in PBPD, particularly where the effect of the height is significant. The modified load pattern reduces the possibility of underdesigning in upper levels and overdesigning in lower levels of the frames.

Field Adaptability Test for the Full Load Rejection of Nuclear Turbine Speed Controllers using Dynamic Simulator

  • Choi, In-Kyu;Kim, Jong-An;Woo, Joo-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.67-74
    • /
    • 2009
  • This paper describes the speed control functions of the typical steam turbine speed controllers and the test results of generator load rejection simulations. The goal of the test is to verify the speed controller's ability to limit the steam turbine's peak speed within a predetermined level in the event of generator load loss. During normal operations, the balance between the driving force of the steam turbine and the braking force of the generator load is maintained and the speed of the turbine-generator is constant. Upon the generator's load loss, in other word, the load rejection, the turbine speed would rapidly increase up to the peak speed at a fast acceleration rate. It is required that the speed controller has the ability to limit the peak speed below the overspeed trip point, which is typically 110[%] of rated speed. If an actual load rejection occurs, a substantial amount of stresses will be applied to the turbine as well as other equipments, In order to avoid this unwanted situation, not an actual test but the other method is necessary. We are currently developing the turbine control system for another nuclear power plant and have plan to do the simulation suggested in this paper.

Design of an Asymmetrical Three-phase Inverter for Load Balancing and Power Factor Correction Based on Power Analysis

  • Mokhtari, M.;Golshannavaz, S.;Nazarpour, D.;Aminifar, F.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.293-301
    • /
    • 2011
  • This paper presents a novel theoretical method based on power analysis to obtain voltage reference values for an inverter-based compensator. This type of compensator, which is installed in parallel with the load, is usually referred to as the active filter. The proposed method is tailored to design the compensator in such a way that it can simultaneously balance the asymmetric load, as well as correct the power factor of the supply side. For clarity, a static compensator is first considered and a recursive algorithm is utilized to calculate the reactance values. The algorithm is then extended to calculate voltage reference values when the compensator is inverter based. It is evident that the compensator would be asymmetric since the load is unbalanced. The salient feature associated with the proposed method is that the circuit representation of system load is not required and that the load is recognized just by its active and reactive consumptions. Hence, the type and connection of load do not matter. The validity and performance of the new approach are analyzed via a numerical example, and the obtained results are thoroughly discussed.

A Network Load Sensitive Block Placement Strategy of HDFS

  • Meng, Lingjun;Zhao, Wentao;Zhao, Haohao;Ding, Yang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.9
    • /
    • pp.3539-3558
    • /
    • 2015
  • This paper investigates and analyzes the default block placement strategy of HDFS. HDFS is a typical representative distributed file system to stream vast amount of data effectively at high bandwidth to user applications. However, the default HDFS block placement policy assumes that all nodes in the cluster are homogeneous, and places blocks with a simple RoundRobin strategy without considering any nodes' resource characteristics, which decreases self-adaptability of the system. The primary contribution of this paper is the proposition of a network load sensitive block placement strategy. We have implemented our algorithm and justify it through extensive simulations and comparison with similar existing studies. The results indicate that our work not only performs much better in the data distribution but also improves write performance more significantly than the others.

Development of Load Distribution Controller on the Midnight-Power Boiler (심야전력용 보일러의 부하분산 제어기 개발)

  • Park, Hyun-Chul;Kim, Yeong-Min;Hwang, Jong-Sun;Lim, Byung-Hyun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.132-135
    • /
    • 2003
  • The use of the midnight power faces the crisis of the load peak-cut problem. Which appears at the simultaneous start of the midnight power system. We suggest a control method which uses the characteristics of boiler system. The system used that method consists of 6 heaters and are designed for the load distribution on each heater. Proposed method can take the balance of load during full time of midnight power supplied. The system is composed of measurement part and heater controller. Taking the data of the experience as a reason, the algorithm make the midnight power distribute. Experimental results show the validity of the method and the system proposed.

  • PDF