• Title/Summary/Keyword: load balance

Search Result 568, Processing Time 0.022 seconds

A study on Dynamic Characteristics of Hydraulic Motor Brake System Integrated Counter Balance Valve (유압 모터 브레이크 시스템의 동특성에 관한연구)

  • Yun, So-Nam;Kim, Hyeong-Ui
    • 한국기계연구소 소보
    • /
    • s.20
    • /
    • pp.27-32
    • /
    • 1990
  • A counter balance valve is used as one part of hydraulic motor brake system. The function of this valve is to protect over-run or free falling of inertia load. But occasionally the brake system with counter balance valve makes some undesirable problems such as pressure surges or vibrations. In this study, for the purpose of easy estimation about dynamic chrcteristics of hydraulic system including counter balance valve, precise formulation describing fluid dynamics and valve dynamics under various boundary conditions were made. dynamic caracteristics were analysed by numerical intergration using Runge-Kutta method, because the equations in this circuit with counter balance valve contain various nonlinear terms. So the analyzing method developed in this study enabled very easy estimating the relation between the performance of counter balance valve and various physical parameters related to the valve.

  • PDF

A Symmetric Carrier Technique of CRPWM for Voltage Balance Method of the Flying Capacitor Multi-level Iinverter (플라잉 커패시터 멀티-레벨 인버터의 커패시터 전압 균형을 이루기 위한 캐리어 비교방식을 이용한 캐리어 대칭 기법)

  • Jeon J.H.;Kim T.J.;Kang D.W.;Hyun D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.606-610
    • /
    • 2003
  • This paper presents a simple carrier symmetric method for the voltage balance of flying capacitors in FCMLI(flying capacitor multi-level inverter). To achieve the voltage balance of flying capacitors, the utilization of each carrier must be balanced during a half-cycle of the switching period such as PSPWM(Phase-Shifted PWM). However, the CRPWM(Carrier Redistribution PWM) method causes the fluctuation of flying capacitor voltages because the balanced utilization of carriers is not achieved. Moreover, it does not consider that the load current change has an influence on flying capacitor voltages by assuming that the current flows Into the load. To overcome the drawbacks of CRPWM, it is modified by the technique that carriers of each band are disposed symmetrically at every fundamental period. Firstly, the CRPWN method is reviewed and the theory on voltage balance of flying capacitors is analyzed. The proposed method Is introduced and is verified through the experiment result.

  • PDF

Debonding failure analysis of prestressed FRP strengthened RC beams

  • Hoque, Nusrat;Jumaat, Mohd Z.
    • Structural Engineering and Mechanics
    • /
    • v.66 no.4
    • /
    • pp.543-555
    • /
    • 2018
  • Fiber Reinforced Polymer (FRP), which has a high strength to weight ratio, are now regularly used for strengthening of deficient reinforced concrete (RC) structures. While various researches have been conducted on FRP strengthening, an area that still requires attention is predicting the debonding failure load of prestressed FRP strengthened RC beams. Application of prestressing increases the capacity and reduces the premature failure of the beams largely, though not entirely. Few analytical methods are available to predict the failure loads under flexure failure. With this paucity, this research proposes a method for predicting debonding failure induced by intermediate crack (IC) for prestressed FRP-strengthened beams. The method consists of a numerical study on beams retrofitted with prestressed FRP in the tension side of the beam. The method applies modified Branson moment-curvature analysis together with the global energy balance approach in combination with fracture mechanics criteria to predict failure load for complicated IC-induced failure. The numerically simulated results were compared with published experimental data and the average of theoretical to experimental debonding failure load is found to be 0.93 with a standard deviation of 0.09.

Design and Implementation of WMI based VOD Service for efficient Load Balance Policy (효율적인 부하 분산 정책을 위한 WMI 기반 VOD 서비스의 설계 및 구현)

  • Bang, Han-Min;Jung, In-Bum
    • Journal of Industrial Technology
    • /
    • v.29 no.A
    • /
    • pp.123-126
    • /
    • 2009
  • Cluster-based servers are utilized for large scale streaming services. These servers show good performance under fair resource usage balance policies between backend nodes. In this paper, cluster-based VOD servers are implemented based on WMI functions. Based on these functions, the information of resource usages in backend nodes can be exchanged and also the working states of cluster nodes can be monitored periodically. In experiences, we find motivations to design an effective load balancing policy. In addition, to provide reliable streaming services, the method to detect a partial failure in cluster-based servers is proposed.

  • PDF

Analytical Study on Effects of Bearing Geometry on Performance of Sliding Thrust Bearings (미끄럼 스러스트베어링의 성능에 미치는 베어링 형상의 영향 해석)

  • Kim, Ho-Jong;Choi, Sung-Pil;Ha, Hyun-Cheon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.7-13
    • /
    • 2006
  • In the present study, we develop an analysis module to be applicable to design of sliding thrust bearings. The pressure equation is solved by using the finite element method. Average lubricant temperature is obtained from using the energy balance method. The module developed has been applied to three types of thrust bearing, such as tapered-land thrust bearings of angular and diamond types, and tilting-pad thrust bearings. Effects of the dam of the tapered-lad thrust bearings have also been investigated. It has been seen that the tapered-land thrust bearings of angular type result in the highest load capacity, while the tilting pad thrust bearings result in the lowest lubricant temperature. It has also been seen that the dam in the tapered-land thrust bearings increases both the load capacity and lubricant temperature.

A Fast Configuration Method for Load Balancing in Distribution System (배전계통의 부하평형을 고려한 고속 계통구성방법)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Hwan;Ryoo, Hee-Suk;Kim, Ho-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.381-383
    • /
    • 2003
  • The authors have developed a solution method based on the incremental algorithm. The optimal load balance between feeders is found through the incremental algorithm with allowing the loop configuration. Therefore loops can be configured in the resulting configuration, and then we must eliminate all loops to satisfy radiality of distribution system because the distribution system is operated under radial status. But the optimal load balance through incremental algorithm is deteriorated when the loops are eliminated. In this paper, authors propose a new method which is to improve the searching procedure of path in the incremental algorithm, that is, so as not to make loop in the path configuration.

  • PDF

Service Restoration In Distribution Networks Using Cyclic Best-First Search (순환적 최적우선탐색을 이용한 배전계통의 정전복구)

  • Choi, Sang-Yule
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.162-168
    • /
    • 2004
  • Service restoration is an emergency control in distribution control centers to restore out-of-service area as soon as possible when a fault occurs in distribution networks. Therefore, it requires fast computation time and high quality solutions for load balancing. In this paper, a load balance index and heuristic guided best-first search are proposed for these problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to identify the most effective the set of switches using proposed search technique and a feeder load balance index. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

Three-Phase Four-Wire Inverter Topology with Neutral Point Voltage Stable Module for Unbalanced Load Inhibition

  • Cai, Chunwei;An, Pufeng;Guo, Yuxing;Meng, Fangang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1315-1324
    • /
    • 2018
  • A novel three-phase four-wire inverter topology is presented in this paper. This topology is equipped with a special capacitor balance grid without magnetic saturation. In response to unbalanced load and unequal split DC-link capacitors problems, a qusi-full-bridge DC/DC topology is applied in the balance grid. By using a high-frequency transformer, the energy transfer within the two split dc-link capacitors is realized. The novel topology makes the voltage across two split dc-link capacitors balanced so that the neutral point voltage ripple is inhibited. Under the condition of a stable neutral point voltage, the three-phase four-wire inverter can be equivalent to three independent single phase inverters. As a result, the three-phase inverter can produce symmetrical voltage waves with an unbalanced load. To avoid forward transformer magnetic saturation, the voltages of the primary and secondary windings are controlled to reverse once during each switching period. Furthermore, an improved mode chosen operating principle for this novel topology is designed and analyzed in detail. The simulated results verified the feasibility of this topology and an experimental inverter has been built to test the power quality produced by this topology. Finally, simulation results verify that the novel topology can effectively improve the inhibition of an inverter with a three-phase unbalanced load while decreasing the value of the split capacitor.

The Effect of Ankle Joint Gram Walk on the Physical Function According to Treadmill Gradient (트레드밀 경사도에 따른 발목 중량부하 걷기 후 신체 기능에 미치는 영향)

  • Ko, Tae-Sung;Lee, Dong-Jin;Ryu, Jong-Ho;Jung, Tae-In;Kim, Tae-Jin;Sho, Seul-Ki;Ahn, Jin-Yeung;Yoon, Li-Na;Yoon, Mi-Ji;Lee, Da-Young;Lee, Seul-Bee;Lim, Kyung-Hee
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.8 no.2
    • /
    • pp.25-31
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate knee muscle strength, balance, and proprioception by walking while giving weight to the ankle joint at a load of 0%, 10%, and 15% gradient on a treadmill. Methods : Twenty-four subjects were divided into three groups. Group A walked on a 0% gradient while giving weight to the ankle joint as a load. Group B walked on a 10% gradient while giving weight to the ankle joint as a load. Group C walked on a 15% gradient while giving weight to the ankle joint as a load. This was performed three times per week for four weeks. The walking speed was set at 4km/hour and the walking time was set at 20 minutes. Measurements were performed before and after the experiment. Biodex medical system and Balance system SD were used as measuring instruments. Results : There was no significant difference between the gradients in muscle strength, balance and proprioception. However, there were differences in pretest and posttest measurements for muscle strength, balance and proprioception in each gradient. In particular, the gradient of 10% showed a significant difference. Conclusion : According to the results of this study, to use a 10% gradient is effective when walking while giving weight to the ankle joint as a load.

Empirical Analysis on the Cooling Load and Evaporation Efficiency of Fogging System in Greenhouses (온실의 냉방부하 및 포그시스템의 증발효율 실험분석)

  • Nam, Sang-Woon;Seo, Dong-Uk;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • In order to develop the cooling load estimation method in the greenhouse, the cooling load calculation formula based on the heat balance method was constructed and verified by the actual cooling load measured in the fog cooling greenhouse. To examine the ventilation heat transfer in the cooling load calculation formula, we measured ventilation rates in the experimental greenhouse which a cooling system was not operated. The ventilation heat transfer by a heat balance method showed a relatively good agreement. Evaporation efficiencies of the two-fluid fogging system were a range of 0.3 to 0.94, average 0.67, and it showed that they increased as the ventilation rate increased. We measured thermal environments in a fog cooling greenhouse, and calculated cooling load by heat balance equation. Also we calculated evaporative cooling energy by measuring the sprayed amount in the fogging system. And by comparing those two results, we could verify that the calculated and the measured cooling load showed a relatively similar trend. When the cooling load was low, the measured value was slightly larger than calculated, when the cooling load was high, it has been found to be smaller than calculated. In designing the greenhouse cooling system, the capacity of cooling equipment is determined by the maximum cooling load. We have to consider the safety factor when installed capacity is estimated, so a cooling load calculation method presented in this study could be applied to the greenhouse environmental design.