• 제목/요약/키워드: load Q

검색결과 373건 처리시간 0.023초

Buckling Analysis of Rectangular Plates using an Enhanced 9-node Element

  • LEE, Sang Jin
    • Architectural research
    • /
    • 제18권3호
    • /
    • pp.113-120
    • /
    • 2016
  • The stability and resistance of the plates under in-plane loading is crucial in the design of structures. For the assessment of structural stability, it is necessarily required to have accurate finite element technologies. Therefore, the enhanced 9-node plate (Q9-ANS) element is introduced for the linear buckling analysis of plate where the critical buckling load has to be determined. The Q9-ANS is developed with the Reissner-Mindlin (RM) assumptions which consider transverse shear deformation of the plate. Assumed shear strain is used to alleviate the shear locking phenomenon. Numerical examples are carried out to verify the performance of the Q9-ANS element in calculation of critical buckling load of the plates.

광역논에서의 질소 .인의 농도와 오염부하량 특성 (Characteristics of Concentration and Load of Nitrogen and Phosphorous in Paddy Field Areas)

  • 김진수
    • 한국농공학회지
    • /
    • 제41권4호
    • /
    • pp.47-56
    • /
    • 1999
  • The concentration and load of T-N and T-P in paddy field areas in Chongwon, Chungbuk , Korea , were investigated during the irrigation period. The concentration of T-N and T-P in ponded water in paddies is higher than that in the irrigation, drainage and percolation waters. For T-N, the average concentration indrainage water was higher than that in irrigation water until end of Jung, But lower thereafter. The average T-N concentration in irrigation water was 2.3 ∼3.2mg/l and therefore the agricultural water quality standard at on-farm level for T-N should be established realistically . The expontial L(load)-Q(discharge) equations have higher coefficients of determination than the linear L-Q equations . Especially, the exponential L-Q equation of T_N showed a coefficient of determinatino of over 0.9 for irrigation water.

  • PDF

점토층 위 모래지반의 지지력비에 따른 얕은 기초의 지지력 거동 (Behavior of Bearing Capacity for Shallow Foundation on a Sand overlying Clay Depending on Bearing Capacity Ratio)

  • 정민형;신효희;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.198-208
    • /
    • 2011
  • 연약 점성지반 위에 상대적으로 낮은 하중의 구조물이 얹어질 때, 상부에 모래층을 두어 지지력을 증진시킬 수 있다. 이와같은 점토 위 모래층이 놓이는 조건에 대한 지지력 검증은 현장에서 평판재하시험 등을 통해 지지력 검증이 어렵기 때문에 설계단계에서부터 정확한 지지력 예측이 필요하다. 따라서, 본 연구는 점토 위 모래층이 놓이는 지반의 지지력 거동을 파악하기 위해 2차원 실내토조실험과 FEM 해석을 수행하였다. 주요 인자로 깊이비 H/B와 지지력비 $q_c/q_s$를 선정하여, 모래층 높이, 점토의 비배수전단강도 그리고 재하 폭을 변수로 하였다. 그 결과, 실내토조실험은 FEM 해석과 적합성이 상당히 높게 나타났다. 이론식과의 비교에 있어서 보다 최신 연구인 Okamura et al.(1998)의 메커니즘보다 관입전단 메커니즘과 그 유사성이 크게 나타났으며, 하중확산 메커니즘의 적용성을 위하여 등가하중확산각을 제시하였다. 또한, $q_c/q_s$에 대하여 무차원 단위의 한계깊이비 $H_f$의 선형 회귀식을 제안하였다.

암반에 근입된 현장타설말뚝의 선단하중전이거동 분석 (End Bearing Load Transfer Behavior of Rock Socketed Drilled Shafts)

  • 조후연;정상섬;설훈일
    • 한국지반공학회논문집
    • /
    • 제25권8호
    • /
    • pp.77-93
    • /
    • 2009
  • 본 연구에서는 3차원 유한차분해석을 통하여 말뚝직경, 암반물성, 불연속면의 간격 및 방향 등 주요 인자가 암반근입 현장타설말뚝의 선단거동에 미치는 영향에 대한 분석을 수행하였으며, 이를 토대로 초기기울기 및 극한 단위선단지지력을 변수로 하는 쌍곡선형태의 선단하중전이(q-w)함수를 제안하였다. 제안식의 국내 암반지반에의 적용을 위하여 국내에서 수행된 14개 현장 23본의 시험말뚝의 재하시험자료를 토대로 제안식의 경험계수를 산정하였으며, 더불어 기존 초기기울기 및 극한단위선단지지력 산정식의 타당성 검토도 수행하였다. 현장재하시험 사례와의 비교분석 결과, 본 연구에서 제안된 산정식은 국내 암반지반에 근임된 현장타설말뚝의 선단거동을 비교적 잘 예측 가능하고, 말뚝지지력 및 침하량 예측값이 실측값에 가까움을 알 수 있었다.

Calculation and field measurement of earth pressure in shield tunnels under the action of composite foundation

  • Chi Zhang;Shi-ju Ma;Yuan-cheng Guo;Ming-yu Li;Babak Safaei
    • Geomechanics and Engineering
    • /
    • 제34권1호
    • /
    • pp.17-27
    • /
    • 2023
  • Taking a subway shield tunnel in a certain section of Zhengzhou Metro Line 5 as an example, the field tests of shield cutting cement-soil monopile composite foundation were carried out. The load and internal force of the tunnel lining under the action of composite foundation were tested on-site and the distribution characteristics and variation laws of earth pressure around the tunnel under the load holding state of the composite foundation were analyzed. Five different load combinations (i.e., overburden load theory + q0, Terzaghi's theory + q0, Bierbaumer's theory + q0, Xie's theory + q0, and the proposed method (the combination of compound weight method and Terzaghi's theory) + q0) were used to calculate the internal force of the tunnel structure and the obtained results were compared with the measured internal force results. The action mode of earth pressure on the tunnel lining structure was evaluated. Research results show that the earth pressure obtained by the calculation method proposed in this paper was more consistent with the measured value and the deviation between the two was within 5%. The distribution of the calculated internal force of the tunnel structure was more in line with the distribution law of field test data and the deviation between the calculated and measured values was small. This effectively verified the rationality and applicability of the proposed calculation method. Research results provided references for the design and evaluation of shield tunnels under the action of composite foundations.

Performance of Rock-socketed Drilled Shafts in Deep Soft Clay Deposits

  • Kim, Myung-Hak
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.409-429
    • /
    • 2006
  • In designing rock-socketed drilled shaft, bearing capacity evaluation is very important because the maximum values of base and side resistance are not generally mobilized at the same value of displacement, FHWA and AASHTO code suggest different ultimate bearing capacity formular according to rock type and shaft settlement. In domestic code suggest base resistance and side resistance can be added on condition that after confirming the result of field load test with axial load transfer test. This paper shows that static load test and hi-directional load test result analysis of deep rock-socketed drilled shaft in three different sites. Load-settlement curve, t-z, and q-w curve in rock-socketed part were calculated and compared. t-z curve in weathered and soft rock showed no deflection softening behavior in pretty large strain (about 2-3% of diameter). Ultimate resistance could be the summation of side resistance and base resistance in rock-socketed drilled shaft in domestic sites.

  • PDF

함정용 탐색레이더 안테나의 구동 토크 분석 및 감쇄에 대한 연구 (Study on Analysis of Driving Torque and Reduction for Naval Surveillance Radar Antenna)

  • 김승우;양윤석
    • 한국군사과학기술학회지
    • /
    • 제12권3호
    • /
    • pp.388-395
    • /
    • 2009
  • Surveillance Radar System for naval vessels is a primary core sensor for command and fire control, and provides CFCS(Command and Fire Control System) information for 3-D surveillance and fire control. It's composed of Antenna, Transmitter/Receiver, Signal Processor, and Air drier, which are installed on and under deck. They should be designed and produced in order to endure at any operating circumstances. This paper analyzes load of a driving part for driving the antenna considering factors under external operating circumstances, and proposes a condition of load for maintaining fixed RPM through analyzing internal load of the driving part, and how to reduce the load to meet the condition. This paper is verified through experimental studies.

수심적분법에 의한 유사량 추정연구 (A Study on Estimation by Depth Integrating Method of Sediment Discharge)

  • 서승덕;김활곤;우효섭
    • 한국농공학회지
    • /
    • 제38권1호
    • /
    • pp.90-97
    • /
    • 1996
  • In Korea, total sediment discharge of a river has been estimated simply by using certain sediment transport formulas including, among others, Einstein's formula. Those formular, however, are known not to be reliable enough for the result calculated by them to be used directly to river planning and management. Therefore, the study used the Modified Einstein Procedure to the estimation of total sediment discharge, because this method is reliable estimated by measurement. Here, measurement of sediment discharge used depth integrating method. The major results obtained from the study for estimation by depth integrating method of sediment discharge in Naeseong stream are as follow; 1 The sedeiment characteristics of Naeseong stream are; The distribution of sediment grain size shows that silt and clay are 55% and sand is 45%. and the bed load sediment grain size is constituted that sand contained with the grain size from O.062mm to 2.0mm is 80% 2. The sediment rating formulas derived from the regression analysis between the sediment discharge and flow discharge are; Seogpo-Gyo : Qs=$0.017 \times 10^{-4} Q^{2.352}$, where discharge is l0cms $0.074 \times 10^{-4} Q^{2.066}$, where discharge is l0cms

  • PDF

Evaluation of side resistance for drilled shafts in rock sections

  • Hsiao, Cheng-Chieh;Topacio, Anjerick J.;Chen, Yit-Jin
    • Geomechanics and Engineering
    • /
    • 제21권6호
    • /
    • pp.503-511
    • /
    • 2020
  • This study evaluated the side resistance of drilled shafts socketed into rock sections. Commonly used analysis methods for side resistance of piles in rocks are examined by utilizing a large number of load test data. The analysis of the unit side resistance of pile foundations embedded into rock sections is based on an empirical coefficient (α) and the uniaxial compressive strength (qu) or its root (${\sqrt{q_u}}$). The Davisson criterion was used to interpret the resistance capacity from the load test results to acquire the computed relationships. The α-${\sqrt{q_u}}$ relationship is proven to be reliable in the prediction of friction resistance. This study further analyzed the relationship by including the effect of rock quality designation (RQD) on the results. Analysis results showed that the analysis model of α-${\sqrt{q_u}}$-RQD provided better prediction and reliability considering the RQD classification. Based on these analyses, the side resistance of drilled shafts socked into rocks is provided with statistical data to support the analysis.

단상 직립 기동형 영구자석 동기기의 회로정수에 따른 특성 해석 (Characteristic Analysis of Single Phase Line-start Permanent Magnet Synchronous Motor Considering Circuit Parameters)

  • 강규홍;홍정표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권6호
    • /
    • pp.262-270
    • /
    • 2003
  • In this paper, the characteristics of single-phase line-start permanent magnet synchronous motor driven by constant voltage are analyzed on d-q axis vector diagram and compared with that of current controlled motor. The coupled method of symmetrical coordinates and d-q axis voltage equation are applied to the analysis method like the analysis of single-phase induction motor. From the result of the analysis, it is seen that motors driven by constant voltage source have effects on not only the amplitude of current and torque but also current and current phase angle, so overall characteristics such as power factor and load angle are affected by circuit parameters. For precise analysis and design of single-phase line-start synchronous motor, its characteristics should be analyzed on d-q axis vector plan in consideration of the variation of circuit parameters.