• 제목/요약/키워드: liquid storage

검색결과 851건 처리시간 0.029초

Characteristic analysis and condenser design of gas helium circulation system for zero-boil-off storage tank

  • Jangdon Kim;Youngjun Choi;Keuntae Lee;Jiho Park;Dongmin Kim;Seokho Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • 제25권4호
    • /
    • pp.65-69
    • /
    • 2023
  • Hydrogen is an eco-friendly energy source and is being actively researched in various fields around the world, including mobility and aerospace. In order to effectively utilize hydrogen energy, it should be used in a liquid state with high energy storage density, but when hydrogen is stored in a liquid state, BOG (boil-off gas) is generated due to the temperature difference with the atmosphere. This should be re-condensed when considering storage efficiency and economy. In particular, large-capacity liquid hydrogen storage tank is required a gaseous helium circulation cooling system that cools by circulating cryogenic refrigerant due to the increase in heat intrusion from external air as the heat transfer area increases and the wide distribution of the gas layer inside the tank. In order to effectively apply the system, thermo-hydraulic analysis through process analysis is required. In this study, the condenser design and system characteristics of a gaseous helium circulation cooling system for BOG recondensation of a liquefied hydrogen storage tank were compared.

Shock absorption of concrete liquid storage tank with different kinds of isolation measures

  • Jing, Wei;Chen, Peng;Song, Yu
    • Earthquakes and Structures
    • /
    • 제18권4호
    • /
    • pp.467-480
    • /
    • 2020
  • Concrete rectangular liquid storage tanks are widely used, but there are many cases of damage in previous earthquakes. Nonlinear fluid-structure interaction (FSI) is considered, Mooney-Rivlin material is used for rubber bearing, nonlinear contact is used for sliding bearing, numerical calculation models of no-isolation, rubber isolation, sliding isolation and hybrid isolation concrete rectangular liquid storage tanks are established; dynamic responses of different structures are compared to verify the effectiveness of isolation methods; and influences of earthquake amplitude, bidirectional earthquake and far-field long-period earthquake on dynamic responses are investigated. Results show that for liquid sloshing wave height, rubber isolation cause amplification effect, while sliding isolation and hybrid isolation have reduction effect; displacement of rubber isolation structure is much larger than that of sliding isolation with limiting-devices and hybrid isolation structure; when PGA is larger, wall cracking probability of no-isolation structure becomes larger, and probability of liquid sloshing wave height and structure displacement of rubber isolation structure exceeds the limit is also larger; under bidirectional earthquake, occurrence probabilities that liquid sloshing wave height and structure displacement of rubber isolation structure exceed the limit will be increased; besides, far-field long-period earthquake mainly influences structure displacement and liquid sloshing wave height. On the whole, control effect of sliding isolation is the best, followed by hybrid isolation, and rubber isolation is the worst.

Seismic Performance Improvement of Liquid Storage Tank using Lead Rubber Bearing (납고무받침을 이용한 액체저장탱크 내진성능향상)

  • Kim, Hu-Seung;Oh, Ju;Jung, Hie-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제39권3호
    • /
    • pp.441-449
    • /
    • 2019
  • Recently, interest in the seismic safety of structures is rising in South Korea due to the occurrences of earthquakes of 5.0 or greater magnitudes such as Gyeongju earthquake (September 2016) and Pohang earthquake (November 2017). In particular, the importance of living facilities that cause human injuries and property losses is more emphasized. Representative living facilities include gas and oil storage facilities and water tanks. In this study, the seismic performance of liquid storage tanks is improved by applying the lead rubber bearing, which is a seismic isolation method. The lead rubber bearing was designed considering the foundation of liquid storage tanks, and the general properties of the lead rubber bearing were verified through compression and shear tests using fabricated specimens. Furthermore, the behaviors of liquid storage tanks according to seismic and non-seismic isolations were analyzed through durability test, shaking table test and finite element analysis using ANSYS.

Analytical Study on Free Vibration of Cylindrical Liquid-Storage Tanks (원통형 액체저장탱크의 고유진동에 대한 이론적 연구)

  • Lee, Jin-Kyu;Lee, Sang-Young;Kim, Ki-Whan;Cho, Jin-Rae;Park, Tae-Hak;Lee, Woo-Yong
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.602-607
    • /
    • 2000
  • Fuel-storage tank is a representative example of liquid-structure interaction systems. In order to prevent the undesired structural failure by a variety of external loads, the reliable analysis of the dynamic response of such structural system is of a great importance. In this paper, we address the analytical study on free vibration of axisymmetric cylindrical fuel-storage tanks together with the parametric investigation of eigen-characteristics with respect to the relative fuel fill-height and the relative tank height. Numerical results illustrating theoretical results are also included.

  • PDF

Cryopreservation of Mulberry(Morus) Seeds in Liquid Nitrogen(L$N_2$) (건조 및 초저온 처리에 의한 뽕나무 종자의 장기 보존)

  • 최영철;류근섭;방혜선
    • Journal of Sericultural and Entomological Science
    • /
    • 제42권1호
    • /
    • pp.1-5
    • /
    • 2000
  • To investigate the possibility of crypreservation of mulberry seeds in liquid nitrogen(LN$_2$), characteristics of the seeds were examined after picking mulberry syncarps and drying-heat treatment. Storage in LN$_2$has the potential of providing indifinite preservation of valuable seed germplasm. Determining the tolerance of seeds among given cultivars to LN$_2$cooling and subsequent rewarming is the first step to establishing the feasibility of LN$_2$storage. Seeds of 4 mulberry varities were treated to LN$_2$(-196$\^{C}$) for 24 hours after drying heat treatment. Seed moisture content of Daeryukppong was the highest. As moisture content of mulberry seed was below 1%, storage in LN$_2$was safe. And drying heat treatment for 60 minutes was suitable to prevent decreased germination rate and germination vigor of seeds. The seeds of Cheongilppong were unsuibable to cryopreserve in LN$_2$for longterm storage.

  • PDF

Finite Element Analysis of the Corrugated Membrane of LNG Storage Tank for Its Geometric Design (LNG 저장탱크용 멤브레인 형상설계를 위한 유한요소해석)

  • 김성원;이성우;이중남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.620-624
    • /
    • 1997
  • Corrugated membranes which are used as a means of liquid- and gas-sealing for a LNG storage tank and provide one of the most reliable primary barrier are the main component of in-ground membrane types for the assurance of high safety. It absorbs large thermal and mechanical deformations caused by ultra low temperature of LNG, -162 .deg.c, the cryogenic liquid and mechanical deformations caused by was carried out on crossing corrugation by commercial F.E code, ANSYS. This paper presents some of results in stress analysis of membranes performed for the purpose to investigate the strength of existing membrane for LNG storage tank designed by IHI,MHI, KHI and KGC expect for Technigaz eariy published. Based on these analytical studies,design criteria were estabilished and SHI original membranes having a high level of safety and fitting to larger capacities were developed.

  • PDF

Effect of Topdressing Methods of Nitrogen Fertilizer on Growth, Yield and Storage of Onion(Allium cepa L.) in Mulch-Cropping System (양파(Allium cepa L,) 멀칭재배시 질소비료 추비방법이 생육, 수량 및 저장성에 미치는 영향)

  • 김우일;서전규
    • Food Science and Preservation
    • /
    • 제5권2호
    • /
    • pp.127-132
    • /
    • 1998
  • In order to fad out an efficient way of topdressing nitrogen fertilizer in mulch-cropping system of onion(Allium cepa L.), solid, slow-release, and liquid forms of nitrogen fertilizers were allied to cv. 'Changnyungdaego' various number of times at different time, with 5 topdress applications of solid fertilizer serving as a control. Whole basal application of conventional solid fertilizer and 2 slow-release fertilizers were labor-saving and showed improved storage quality of bulbs, but resulted in poor plant growth and considerably low yield due to fertilizer shortage from early April. This suggests that topdress application is necessary. Liquid form of nitrogen fertilizer was more effective for plant growth and yield and saving labor than the solid form. Early applications was effective for increasing yield and storage quality of onion bulbs harvested. Thus two applications of liquid form of nitrogen fertilizer in February and March at rome month interval are recommended in mulch crowing system of onion.

  • PDF

Shaking table test of liquid storage tank with finite element analysis considering uplift effect

  • Zhou, Junwen;Zhao, Ming
    • Structural Engineering and Mechanics
    • /
    • 제77권3호
    • /
    • pp.369-381
    • /
    • 2021
  • The seismic responses of elevated tanks considering liquid-structure interaction are presented under horizontal earthquake. The scaled model tank is fabricated to study the dynamic responses of anchored tank and newly designed uplift tank with replaced dampers. The natural frequencies for structural mode are obtained by modal analysis. The dynamic responses of tanks are completed by finite element method, which are compared with the results from experiment. The displacement parallel and perpendicular to the excitation direction are both gained as well as structural acceleration. The strain of tank walls and the axial strain of columns are also obtained afterwards. The seismic responses of liquid storage tank can be calculated by the finite element model effectively and the results match well with the one measured by experiment. The aim is to provide a new type of tank system with vertical constraint relaxed which leads to lower stress level. With the liquid volume increasing, the structural fundamental frequency has a great reduction and the one of uplift tank are even smaller. Compared with anchored tank, the displacement of uplift tank is magnified, the strain for tank walls and columns parallel to excitation direction reduces obviously, while the one perpendicular to earthquake direction increases a lot, but the values are still small. The stress level of new tank seems to be more even due to uplift effect. The new type of tank can realize recoverable function by replacing dampers after earthquake.

An Approach to the Localization of Technology for a Transport and Storage Container for Very Low-Level Radioactive Liquid Waste

  • Shin, Seung Hun;Choi, Woo Nyun;Yoon, Seungbin;Lee, Un Jang;Park, Hye Min;Kim, Hee Reyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제20권1호
    • /
    • pp.127-131
    • /
    • 2022
  • The structural safety of prototype transport and storage containers for very low-level radioactive liquid waste was experimentally estimated for its localization development. Transport containers for radioactive liquid waste have been researched and developed, however, there are no standardized commercial containers for very low-level radioactive waste in Korea. In this study, the structural safety of the designated IP-2 type container capable of transporting and temporarily storing large amounts of very low-level liquid waste, which is generated during the operation and decommissioning of nuclear power plants, was demonstrated. The stacking and drop tests, which were conducted to determine the structural integrity of the container, verified that there was no external leakage of the contents in spite of its structural deformation due to the drop impact. This study shows the effort required for the localization of the technology used in manufacturing transport and storage containers for very low-level radioactive liquid waste, and the additional structural reinforcement of the container in which the commercial intermediate bulk container (IBC) external frame was coupled.

Seismic Fragility Analysis of Base Isolated Liquid Storage Tank (면진 유체 저장 탱크의 지진취약도 분석)

  • Ahn, Sung-Moon;Choi, In-Kil;Choun, Young-Sun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.453-460
    • /
    • 2005
  • In this study, the seismic fragility analysis of a base isolated condensate storage tank installed in the nuclear power plant. The condensate storage tank is safety related structure in a nuclear power plant. The failure of this tank affect significantly to the core damage frequency of the nuclear power plants. The seismic analysis of the liquid storage tank was performed by the simple calculation method and the dynamic time storage analysis method. The convective and impulsive fluid mass is modeled as added masses proposed by several researchers. To evaluate the effectiveness of the isolation system, the comparison of HCLPF and core damage frequencies in non-isolated and isolated cases are carried out. It can be found from the results that the seismic isolation system increases the seismic capacity of a condensate storage tank and decreases the core damage frequency significantly.

  • PDF