Storage Stability of Seasoned-Dried Pacific Saury (Imported Product) Treated with Liquid Smoke

  • Cha, Yong-Jun;Park, Sung-Young;Cho, Woo-Jin;Lee, Young-Mi;Kim, Hyounjin;Kim, Jin-Soo
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.4
    • /
    • pp.235-239
    • /
    • 2001
  • In order to enhance suitable processing methods of imported Pacific saury, Cololabis saira, storage stability of seasoned-dried Pacific saury (imported product) treated with liquid smoke (T2 product) was compared with a control (C, seasoning only) and T1 (treatment of 0.05% BHT instead of liquid smoke). The histamine contents of 3 seasoned-dried products were within a stable range (9.08 ~ 12.08 mg/100 g) during storage. The water activities of all products were in the 0.698 ~ 0.755 range. The viable cell count of T2 was lower than those of C and T1 during storage. The change in color values of C, T1 and T2 were not significant with increasing storage period. The results of the sensory evaluation during storage showed that the shelf-life of T2 was extended to 60 days, while those of C and T1 were limited to up to 45 days.

  • PDF

Axisymmetrical free-vibration analysis of liquid-storage tanks considering the liquid compressibility

  • Cho, Jin-Rae;Lee, Jin-Kyu
    • Structural Engineering and Mechanics
    • /
    • v.13 no.4
    • /
    • pp.355-368
    • /
    • 2002
  • In this paper, we address the numerical investigation on the effect of liquid compressibility onto the natural frequency of liquid-filled containers. Traditionally the liquid motion has been treated as an ideal fluid motion. However, from the numerical experiments for the axisymmetrical free-vibration of cylindrical liquid-storage tanks, we found that the relative difference in natural frequencies between ideal and compressible motions becomes remarkable, as the slenderness of tank or the relative liquid-fill height becomes larger. Therefore, in such cases of dynamic systems, the liquid compressibility becomes an important parameter, for the accurate vibration analysis. For the free-vibration analysis of compressible liquid-structure interaction we employed the coupled finite element formulation expressed in terms of the acoustic wave pressure and the structure deformation.

Pseudo-Dynamic Tests on Base-Isolated Liquid Storage Tanks (기초분리(基礎分離)된 액체저장(液體貯藏)탱크의 유사(類似) 동적실험(動的實驗))

  • Kim, Nam Sik;Lee, Dong Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.51-64
    • /
    • 1993
  • Base-isolated liquid storage tanks under seismic loading were tested by the Pseudo-dynamic test method. Substructuring technique in which a mixed integration method was adopted and the liquid tanks were simply modeled as a discrete system. This study gave experimental verification on the advantage of mounting the liquid tanks on base isolators in order to reduce the hydrodynamic forces on the tank wall.

  • PDF

Seismic reliability of concrete rectangular liquid-storage structures

  • Cheng, Xuansheng;He, Peicun;Yu, Dongjiang
    • Structural Engineering and Mechanics
    • /
    • v.70 no.5
    • /
    • pp.563-570
    • /
    • 2019
  • To analyze the seismic reliability of concrete rectangular liquid storage structures (CRLSSs), assuming that the wall thickness and internal liquid depth of CRLSSs are random variables, calculation models of CRLSSs are established by using the Monte Carlo finite element method (FEM). The principal stresses of the over-ground and buried CRLSSs are calculated under three rare fortification intensities, and the failure probabilities of CRLSSs are obtained. The results show that the seismic reliability increases with the increase of wall thickness, whereas it decreases with the increase of liquid depth. Between the two random factors, the seismic reliability of CRLSSs is more sensitive to the change in wall thickness. Compared with the over-ground CRLSS, the buried CRLSS has better reliability.

Response of base-isolated liquid storage tanks to near-fault motions

  • Jadhav, M.B.;Jangid, R.S.
    • Structural Engineering and Mechanics
    • /
    • v.23 no.6
    • /
    • pp.615-634
    • /
    • 2006
  • Seismic response of the liquid storage tanks isolated by the elastomeric bearings and sliding systems is investigated under near-fault earthquake motions. The fault normal and parallel components of near-fault motion are applied in two horizontal directions of the tank. The continuous liquid mass of the tank is modeled as lumped masses known as sloshing mass, impulsive mass and rigid mass. The corresponding stiffness associated with these lumped masses has been worked out depending upon the properties of the tank wall and liquid mass. It is observed that the resultant response of the isolated tank is mainly governed by fault normal component with minor contribution from the fault parallel component. Further, a parametric study is also carried out to study the effects of important system parameters on the effectiveness of seismic isolation for liquid storage tanks. The various important parameters considered are: aspect ratio of tank, the period of isolation and the damping of isolation bearings. There exists an optimum value of isolation damping for which the base shear in the tank attains the minimum value under near-fault motion. The increase of damping beyond the optimum value will reduce the bearing and sloshing displacements but increases the base shear. A comparative performance of five isolation systems for liquid storage tanks is also studied under normal component of near-fault motion and found that the EDF type isolation system may be a better choice for design of isolated tank in near-fault locations. Finally, it is also observed that the satisfactory response can be obtained by analysing the base-isolated tanks under simple cycloidal pulse instead of complete acceleration history.

A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater (복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구)

  • Choi, Hwi-Ung;Rokhman, Fatkhur;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

Seismic Analysis of Liquid Storage Structures sing Eulerian Formulation (Eulerian 기법을 이용한 유체저장구조물의 지진해석)

  • 윤정방;김재민;김영석;전영선
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1991.10a
    • /
    • pp.43-48
    • /
    • 1991
  • In this paper the liquid sloshing effects in rectangular liquid stroage structures under earthquake loadings are studied. The study focuses on the investigation of the effect of the flexibility of the stroage wall. The storage structure is modelled using beam elements. The motion of the liquid is expressed by the Laplace equation. The equation of motion is formulated including the coupling between the wall motion and the sloshing motion. Seismic analyses have been carried out utilizing the response spectra method.

  • PDF

Seismic response analysis of an unanchored vertical vaulted-type tank

  • Zhang, Rulin;Cheng, Xudong;Guan, Youhai;Tarasenko, Alexander A.
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.67-77
    • /
    • 2017
  • Oil storage tanks are vital life-line structures, suffered significant damages during past earthquakes. In this study, a numerical model for an unanchored vertical vaulted-type tank was established by ANSYS software, including the tank-liquid coupling, nonlinear uplift and slip effect between the tank bottom and foundation. Four actual earthquakes recorded at different soil sites were selected as input to study the dynamic characteristics of the tank by nonlinear time-history dynamic analysis, including the elephant-foot buckling, the liquid sloshing, the uplift and slip at the bottom. The results demonstrate that, obvious elephant-foot deformation and buckling failure occurred near the bottom of the tank wall under the seismic input of Class-I and Class-IV sites. The local buckling failure appeared at the location close to the elephant-foot because the axial compressive stress exceeded the allowable critical stress. Under the seismic input of Class-IV site, significant nonlinear uplift and slip occurred at the tank bottom. Large amplitude vertical sloshing with a long period occurred on the free surface of the liquid under the seismic wave record at Class-III site. The seismic properties of the storage tank were affected by site class and should be considered in the seismic design of large tanks. Effective measures should be taken to reduce the seismic response of storage tanks, and ensure the safety of tanks.

Analytical Study on the Temperature and Pressure Changes in DME FPSO Storage Tank with Liquid Filling level (DME FPSO 저장탱크의 액충전량에 따른 온도 및 압력변화에 대한 해석 연구)

  • Yun, Sangkook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1024-1029
    • /
    • 2012
  • As DME (Dimethyl ether) is the one of the future possible massive energy sources synthesized from natural gas, KOGAS has been doing to obtain overseas resources to meet the domestic needs. and tried to build new DME FPSO ship. This paper presents that it can help for the DME storage tank designers and storage management engineers doing proper work by understood the evaporation phenomena and pressure change of DME by thermal intake in storage tank. The experimental result shows that the evaporation rate and pressure are increased with higher liquid filling level. The proper DME liquid filling level in tank is obtained as lower than full 98% volume of tank in case of storing longer than a day, because the pressure is increased rapidly with full 98% filled level of storage tank.

Seismic vulnerability of sliding isolation concrete rectangular liquid storage tanks

  • Cheng, Xuansheng;Yin, Siyuan;Chen, Wenjun;Jing, Wei
    • Structural Engineering and Mechanics
    • /
    • v.84 no.4
    • /
    • pp.503-515
    • /
    • 2022
  • Based on the sliding isolation concrete LSS (liquid-storage structure), the specific seismic vulnerability is analyzed according to the general failure mode. In this study, 12 seismic inputs with different characteristics are used, and their acceleration peak values are modulated. By inputting these waves to the sliding isolation concrete storage structure, the finite-element models of different concrete rectangular LSSs are obtained and analyzed, and the failure probabilities are obtained according to the IDA (incremental dynamic analysis) curves of the structure. The results show that when the seismic acceleration peak value gradually increases from 0.1 g to 1.0 g, the failure probability of LSS gradually increases with the increase in friction coefficient. However, the failure probability of a sliding isolation LSS is less than 100% and far less than the failure probability of a non-isolated rectangular LSS, which shows that an isolated liquid storage structure continues working under a big earthquake. Thus, the sliding isolation for the concrete LSS has a significant damping effect.