• Title/Summary/Keyword: liquid standard

Search Result 1,136, Processing Time 0.028 seconds

Assessment on the Extraction Efficiency of Explosive Compounds in Soil for Improving the Working Draft of International Standard (국제표준(안) 개선을 위한 토양 중 화약물질 추출 효율성 평가)

  • Lee, Goon-Taek;Jung, In-Ho;Kim, Bo-Hyun;Kim, Dong-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.1
    • /
    • pp.42-46
    • /
    • 2012
  • The ISO document of ISO/TC/190/SC3/WG11/N11 is a working draft of international standard (WD) dealing with analytical method for the determination of explosives and related compounds using high performance liquid chromatography. The scope of this WD covers the storage of samples, preparing test portion, extraction and instrumentation. The main purpose of this study was to improve the extraction conditions which were already adopted in the WD. For this purpose, mechanical shaking method could be corresponded up to 18 hours of ultrasonic bath extraction in the WD was tested. Methanol was also tested with the intention of being added as an extracting solvent other than acetonitrile in the WD. According to the results, 16 hours of mechanical shaking method showed statistically the same effectiveness as that of 18 hours of ultrasonic bath extraction. In case of extracting solvent, methanol also showed statistically the same extraction capability as acetonitrile for DNB, TNT, 2-A-DNT and 2,4-DNT. However, the recovery rate of TNB with methanol extraction was 40% higher than that of acetonitrile extraction. Through adding mechanical shaking method into committee draft (cf. the next stage draft of the WD during the process for making international standard), ISO standard of analyzing explosives and related compounds in soil would become more useful in dealing with huge number of field samples in the laboratory. In other aspect, adopting methanol as an alternative extracting solvent would be very effective in the terms of exchangeability with GC-ECD/MS method which is being developed by German experts.

Liquid Uptake and Methanol Transport Behaviour of PVDF/SPEEK/TiO2 Hybrid Membrane for DMFC (DMFC용 PVDF/SPEEK/TiO2 하이브리드 막의 수분함량과 메탄올 전이현상)

  • You, Sun-Kyung;Kim, Han-Joo;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.177-180
    • /
    • 2005
  • A series of inorganic-organic hybrid membranes were prepared with a systematic variation of titanium dioxide nano particles content. Their liquid uptake, methanol permeability and proton conductivity as a function of inorganic oxide content were investigated. The results obtained show that the inorganic oxide network decreases the proton conductivity and liquid uptake. It is also found that increase in inorganic oxide content leads to decrease of methanol permeability. In terms of the morphology, membranes are homogeneous and exhibit a good adhesion between inorganic domains and the polymer matrix. The properties of the composite membranes are compared with the standard nafion membrane.

Liquefaction Characteristics of HDPE, PP and PS by Isothermal Pyrolysis (HDPE, PP 및 PS의 등온열분해에 의한 액화 특성)

  • Yu, Hong-Jeong;Park, Su-Yul;Lee, Bong-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.198-205
    • /
    • 2002
  • Isothermal pyrolysis of high density polyethylene(HDPE), polypropylene(PP) and polystyrene(PS) was performed at $450^{\circ}C$, respectively. The effect of pyrolysis time on yield and product composition was investigated. Conversion and liquid yield obtained during HDPE pyrolysis continuously increased with time up to 80minutes, but those of PP and PS did not largely change after 35minutes. Each liquid product formed during the pyrolysis was classified into gasoline, kerosene, light oil and wax according to the distillation temperature based on the petroleum product quality standard of Korea Petroleum Quality Inspection Institute. The major liquid product of HDPE pyrolysis was light oiH34 wt.% based on the amount of HDPE treated) and the amounts of the other liquid ingredients(gasoline, kerosene and wax) were almost the same. On the other hand, the pyrolysis of PP produced 27 wt.% gasoline, 22 wt.% kerosene, 24 wt.% light oil and 13wt.% wax, and the pyrolysis of PS produced 56 wt.% gasoline, 12 wt.% kerosene, 9 wt.% light oil and 13 wt.% wax.

In-situ measurement of railway-traffic induced vibrations nearby the liquid-storage tank

  • Goktepe, Fatih;Kuyuk, Huseyin S.;Celebi, Erkan
    • Earthquakes and Structures
    • /
    • v.12 no.5
    • /
    • pp.583-589
    • /
    • 2017
  • In this study, result of a field investigation of railway traffic-induced vibrations is provided to examine acceptability levels of ground vibration and to evaluate the serviceability of a liquid-storage tank. Free field attenuation of the amplitudes as a function of distance is derived by six accelerometers and compared with a well-known half-space Bornitz's analytical solution which considers the loss of the amplitude of waves due to geometrical damping and material damping of Rayleigh. Bornitz's solution tends to overlap vertical free field vibration compared with in-situ measured records. The vibrations of the liquid-storage tank were compared with the USA, Federal Transportation Railroad Administration (FTA) criteria for acceptable ground-borne vibrations and with the criteria in DIN 4150-3 German standard. Comparing the thresholds stated in DIN 4150-3, absolute peak particle velocities are within the safe limits, however according to FTA velocity level at the top of the water tank exceeds the allowable limits. Furthermore, it is intended to indicate experimentally the effect of the kinematic interaction caused by the foundation of the structure on the free-field vibrations.

New Cooling Techniques of High Tc Superconductor Systems (고온초전도 시스템의 새로운 냉각기술)

  • Chang, Ho-Myung
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.7-11
    • /
    • 1999
  • The recent progress in new cooling techniques of the high Tc superconductor(HTS) systems is reported and discussed with some practical examples. At the beginning stage of the HTS development in research laboratories, liquid nitrogen(LN$_2$) is the standard medium for an effective cooling. The success of HTS in many different application areas, however, has required a variety of need in the cooling temperature and the cooling capacity with specific design restrictions. While the utilization of alternative liquid cryogens such as liquid neon (LNe) or liquid hydrogen (LH$_2$) has been tired in some of them, even solid cryogens such as solid nitrogen (SN$_2$) or solid hydrogen (SH$_2$) may be another option in special applications. The gaseous helium cooled by a cryogenic refrigerator has also been a good candidate in many cases. One of the best cooling methods for the HTS is the direct conduction-cooling by a closed-cycle refrigerator with no cryogen at all. The refrigeration may be based on Joul-Thomson, Brayton, Stirling, Gifford-McMahon, or pulse tube cycles. The pros and cons of the newly proposed cooling methods are described and some significant design issues are presented.

  • PDF

Numerical Analysis of Cryogenic Liquid Nitrogen Jets at Supercritical Pressures using Multi-Environment Probability Density Function approach (다점 확률분포 모델을 이용한 초임계 압력 액체질소 제트 해석)

  • Jung, Kiyoung;Kim, Namsu;Kim, Yongmo
    • Journal of ILASS-Korea
    • /
    • v.22 no.3
    • /
    • pp.137-145
    • /
    • 2017
  • This paper describes numerical modeling of transcritical and supercritical fluid flows within a liquid propellant rocket engine. In the present paper, turbulence is modeled by standard $k-{\varepsilon}$ model. A conserved scalar approach in conjunction with multi-environment probability density function model is used to account for the turbulent mixing of real-fluids in the transcritical and supercritical region. The two real-fluid equations of state and dense-fluid correction schemes for mixtures are used to construct thermodynamic data library based on the conserved scalar. In this study, calculations are made on two cryogenic nitrogen jets under different chamber pressures. Sensitivity analysis for two different real-fluid equations of sate is particularly emphasized. Based on numerical results, precise structures of cryogenic nitrogen jets are discussed in detail. Numerical results show that the current real-fluid model can predict the essential features of the cryogenic liquid nitrogen jets.

Determination of tylosin in edible meats by high-performance liquid chromatography (HPLC를 이용한 식육내 타이로신의 잔류분석법)

  • Kim, Gon-sup;Shin, Sun-hye;Kim, Jong-su;Ra, Do-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.13-19
    • /
    • 2001
  • A simple and rapid analytical method for the determination of tylosin in chicken, pork and muscle was established by High-Performance Liquid Chromatography(HPLC). Chicken, pork and beef muscle(5 g) were fortified by adding the $0.2{\mu}g/ml$ of standard tylosin and the drug was extracted from meats with 70% acetonitrile(ACN) and followed by liquid-liquid partition for clean-up procedure. Then $20{\mu}l$ portion of ACN elution was directly analyzed by HPLC with spectra 100 variable wavelength detector, and unfortified blank control were treated similarly. The average recovery rate of tylosin added to chicken, pork and beef muscle were $83{\pm}2.3$, $96{\pm}3.3$ and $92{\pm}1.6$(%) at the level 0.2 ppm, respectively. No tylosin residues in marketing meats. These results suggested that HPLC methodology could be acceptable for the extraction, determination and screening of tylosin residues in edible meats.

  • PDF

Rapid Quantification of Topotecan in Biological Samples by Liquid Chromatography/Tandem Mass Spectrometry

  • Shin, Beom-Soo;Lee, Mann-Hyung;Yoo, Sun-Dong
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.5
    • /
    • pp.367-372
    • /
    • 2009
  • A rapid liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay method was developed for the determination of topotecan levels in rat serum. The assay utilized a single liquid-liquid extraction with a mixture of ethy l acetate and acetonitrile (6:1 v/v) and isocratic elution. The multiple reaction monitoring was based on the transition of m/z 422.0$\rightarrow$376.5 for topotecan and 315.1$\rightarrow$226.6 for clomipramine (internal standard). The developed assay was validated to demonstrate the specificity, recovery, lower limit of quantification (LLOQ), accuracy and precision. The assay was linear over a concentration range from 0.5-100 ng/mL, with LLOQ being 0.5 ng/mL using a small volume of rat serum (0.1 mL). The mean intra- and inter-day assay accuracy was 87.7-111.0% and 97.8-108.3, respectively, and the mean intra- and interday precision was between 1.6-4.3% and 3.8-10.3, respectively. The developed assay was applied to a pharmacokinetic study after a bolus i.v. injection of topotecan in rats.

Simultaneous Analysis of Pesticide Priority Pollutants in Water Samples (수질 시료 중의 Pesticide Priority Pollutants 동시분석에 관한 연구)

  • Kim Kye-Young;Kim Chong-Hyeak;Lee Sueg-Geun
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.590-598
    • /
    • 1993
  • The simultaneous analysis of samples, 16 organic pesticides in water among 129 priority pollutants listed by EPA, was performed by GC-ECD (electron capture detector) and GC/MS-SIM (selected ion monitoring). Two extraction procedures, liquid-liquid extraction (LLE) and solid-phase extraction (SPE), were studied as an extraction and concentration method. Accuracy and precision of the methods were measured by the calculation of mean recovery and mean relative standard deviation. Finally, the detection limits, the experimental limitations, and prospects were discussed.

  • PDF