• Title/Summary/Keyword: liquid scintillation counting

Search Result 64, Processing Time 0.025 seconds

Application of Geometry-Efficiency Variation Technique to Activity Measurement of $^{204}T1$ for 3-PM Liquid Scintillation Counting

  • Lee Hwa Yong;Seo Ji Suk;Kwak Ji Yeon;Hwang Han-Yull;Lee K. B.;Lee Jong Man;Park Tae Soon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.121-126
    • /
    • 2004
  • 3-PM liquid scintillation counting using the geometry-efficiency variation technique has been applied to the activity measurement of $^{204}T1$, which decays to $^{204}Hg\;and\;^{204}Pb\;by\;{\beta}^-$ and E.C., respectively. The TDCR values K have been derived over a wide range, 0.78 < K < 0.97, by displacing the detectors up to 50 mm away from an unquenched liquid scintillation sample $^{204}Tl$. The derived plots of the logic sums of double coincidences $N_D(K)$ very K vary linearly in the observed regions. The fractions of losses due to electron capture decay have been taken into account by employing a PENELOPE Monte Carlo simulation. The calibrated activity is 102.3 kBq at a reference date of July 1st, 2002 (UT) with a combined uncertainty of $0.63\%$. This is consistent with the value determined by means of the CIEMAT/NIST method at KRISS.

Tritium( $^3$H) Activity Measurement by the Liquid Scintillation Counting Method

  • Hwang, Sun-Tae;Oh, Pil-Jae;Lee, Min-Kie;Kim, Wi-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.299-302
    • /
    • 1994
  • At a nuclear power plant, environmental radioactivity monitoring is routine work for the radiation safety management For the environmental monitoring of tritium($^3$H) activity in water sampled liquid scintillation counting( LSC) method is applied to measure low- energy beta activity from tritium in the samples. The $^3$H activity is measured using the BECKMAN 5801 system at the KRISS( Korea Research Institute of Standards and Science) for evaluating the lower limits of detection( LLD) of $^3$H measurement and the measuring capability of low-level $^3$H activity at four nuclear Power Plant sites. The LSC systems used for low-level $^3$H activity measurements at the nuclear Power Plants are confirmed to satisfy throughout an intercomparison study under the experimental arrangements by the KRISS.

  • PDF

Determination of the Water Uptake Rate into Biodegradable Polymer (생분해성 고분자로의 물의 유입속도 측정)

  • Park, Eun-Seok;Chi, Sang-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.3
    • /
    • pp.223-226
    • /
    • 1995
  • A new method to study water uptake into biodegradable polymer was developed. Polymer was gently mixed with the tritiated buffer and the radioactivity level of the polymer due to water uptake was measured by liquid scintillation counting. The rate of water uptake was estimated from the plot of the amount of water in the device as a function of time. The technique used in this study is particularly useful for estimating water uptake of biodegradable polymers which were difficult to study by other techniques such as weight gain used for hydrogel.

  • PDF

An Improved Movable 3 photomultiplier (3PM)-γ Coincidence Counter Using Logical Sum of Double Coincidences in β-Channel for Activity Standardization

  • Hwang, Han Yull;Lee, Jong Man
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.76-80
    • /
    • 2020
  • Background: To improve the measurement accuracy of liquid-scintillation counting for activity standardization, it is necessary to significantly reduce the background caused by thermal noise or after-pulses. We have therefore improved a movable 3 photomultiplier (3PM)-γ coincidence-counting method using the logical sum of three double coincidences for β events. Materials and Methods: We designed a new data-acquisition system in which β events are obtained by counting the logical sum of three double coincidences. The change in β-detection efficiency can be derived by moving three photomultiplier tubes sequentially from the liquid-scintillation vial. The validity of the method was investigated by activity measurement of 134Cs calibrated at the Korea Research Institute of Standards and Science (KRISS) with 4π(PC)β-γ(NaI(Tl)) coincidence counting using a proportional counter (PC) for the β detector. Results and Discussion: Measurements were taken over 14 counting intervals for each liquidscintillation sample by displacing three photomultiplier tubes up to 45 mm from the sample. The dead time in each β- and γ-counting channel was adjusted to be a non-extending type of 20 ㎲. The background ranged about 1.2-3.3 s-1, such that the contributions of thermal noise or after-pulses were negligible. As the β-detection unit was moved away from the sample, the β-detection efficiencies varied between 0.54 and 0.81. The result obtained by the method at the reference date was 396.3 ± 1.7 kBq/g. This is consistent with the KRISS-certified value of 396.0 ± 2.0 kBq/g within the uncertainty range. Conclusion: The movable 3PM-γ method developed in the present work not only succeeded in reducing background counts to negligible levels but enabled β-detection efficiency to be varied by a geometrical method to apply the efficiency extrapolation method. Compared with our earlier work shown in the study of Hwang et al. [2], the measurement accuracy has much improved. Consequently, the method developed in this study is an improved method suitable for activity standardization of β-γ emitters.

A Rapid Method for the Measurement of $^{222}Rn$ in Groundwater and Hot Spring Water using Ultra Low-Level Liquid Scintillation Counter and Pulse Shape Analysis (극저준위 액체섬광계수기와 파형분석법을 이용한 지하수 및 온천수중 $^{222}Rn$의 신속측정법)

  • Kim, Chang-Kyu;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.103-115
    • /
    • 1995
  • For the determination of $^{222}Rn$ in water by a very simple and time saving liquid scintillation counting method that does not require any chemical separation, an optimum analytical condition has been investigated. The optimum pulse shape analysis(PSA) level for the measurement of $^{222}Rn$ using LKB 1220 Quantulus liquid scintillation counter was 110 for Optiphase HiSafe3 cocktail and 90 for toluene-based cocktail. The counting efficiencies of $^{222}Rn$ in the window covering u spectra using Optiphase HiSafe3 cocktail were 282.2% for glass vial and 271.6% for Teflon vial, whereas the counting efficiencies in toluene-based cocktail were 262.3% and 247.5% for glass and Teflon vials, respectively. The minimum detectable activity(MDA) in the u window for a 60-min measurement with a Teflon vial using Optiphase HiSafe3 cocktail was $0.30Bq/{\iota}$. The analytical method studied from this work was also applied to the determination of $^{222}Rn$ in some groundwater and hot spring water samples.

  • PDF

Simulation of Beta Ray Spectra in Liquid Scintillation Counting System by means of Monte Carlo Method (Monte Carlo 계산에 의한 액체섬광계수기의 베타선 스펙트럼 Simulation)

  • Yi, Chul-Young;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.17-25
    • /
    • 1993
  • Beta ray spectra of $^3H,\;^{14}C\;and\;^{36}Cl$ in liquid scintillation counting system have been calculated using the Monte Carlo method by which physical behaviors of particle transport in medium were simulated. The calculations have been carried out on the basis of beta rays being slowing down according to the continuous slowing down approximation(CSDA) model. Beta rays generated in simulation geometry were traced until they lost their energy below 0.3keV that in known to be the detection limit in the liquid scintillation counter. Scintillator solution in which pure beta emitting radionuclides were dissolved uniformly was assumed to be bottled in the shape of right circular cylinder with 12.5mm in radius and 35mm in height. The comparison of the calculated and measured results showed satisfactory agreement between those two, with slight discrepancy due to self quenching in the case of lower energy of emitted beta particles in the solution.

  • PDF

Low level tritium analysis using liquid scintillation counter (액체섬광계수기를 이용한 저준위 트리튬 분석법연구)

  • Yoon, Yoon Yeol;Cho, Soo Young;Lee, Kil Yong;Kim, Yongje
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.419-423
    • /
    • 2007
  • Environmental low level tritium analysis was studied using liquid scintillation counter(LSC) and electrolytic enrichment method. To obtain low level blank count, various counting vials were investigated. Among them, teflon coated PE vial had a lower blank count rate (1.86 cpm) and we obtained 2.01 Bq/L detection and tritium separation factor was above 20. LSC counting efficiency obtained $28.70{\pm}0.27%$ using the NIST tritium standard water sample.

Comparison of Phenyl Ethylamine and Hyamine Base as an Absorbent of $Carbon^{14}$ Dioxide ($C^{14}O_2$의 흡수제(吸收劑)로서 폐닐에칠아민과 하이아민베이스의 비교(比較))

  • Chiang, Yun-Hwan
    • Applied Biological Chemistry
    • /
    • v.14 no.1
    • /
    • pp.51-57
    • /
    • 1971
  • In order to compare their absorption abilities of carbon dioxide, Hyamine base and phenyl ethylamine were employed in wet combustion experiments. The known content of liver lipid and uniformly mixed palmitic $acid-C^{14}$ were oxidized with sulfuric acid and phosphoric acid. Carbon dioxide produced was trapped by the amines tested through thin tube. The amines absorbed carbon dioxide were mixed with diotal scintillator and counted by liquid scintillation counter. The counting efficiencies and radioactivity recoveries were 50 to 60 % and nearly 100 % for both amines. However, the absorption ability of carbon dioxide by phenyl ethylamine was about two times that of Hyamine base. This technique would not be necessary for the counting of liver lipid of swim, because the efficiencies were not increased and counting accuracies were similar to those of direct counting.

  • PDF

A Study of the Rn-222 and Ra-226 Analysis in Aqueous Samples with a Low-Level Liquid Scintillation Counter and Pulse-Shape Analysis (저준위 액체섬광계수기와 파형분석법을 이용한 수용액 중 라돈-222 및 라듐-226의 분석법 연구)

  • Shin, Hyun-Sang;Lee, Chang-Woo;Lee, Myung-Ho;Cho, Yung-Hyun;Hong, Kwang-Hee;Choi, Geun-Sik
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.428-435
    • /
    • 1999
  • A method for measuring Rn-222 and Ra-226 in aqueous sample using liquid scintillation counting technique has been studied. The Rn-222 was extracted easily from the water sample (10 mL) by 12 mL of xylene based organic scintillant. After radioactive equilibrium between Rn-222 and its alpha emitting decay products for three hours, the alpha activity from Rn-222 and its decay products were measured in a scintillation vial using the Wallae $1220^{TM}$ Quantulus liquid scintillation counter. Ra-226 concentration in aqueous sample was determined, after isolation of Ra-226 from the sample matrix, by extraction the ingrowth of the Rn-222 and its alpha emitting decay products with xylene based organic scintillant. The optimum pulse-shape analysis (PSA) value was evaluated by the figure of merit (FM) criterion. Minimum detectable activity (MDA) is about 0.14 Bq/L (3.78 pCi) for the region of Rn-222 and its alpha emitting decay products and 0.06 Bq/L (1.63 pCi) for the region of Po-214 respectively, with 200 min, counting time at PSA level 100 in the low-diffusion polyethylene vial and xylene based cocktail solution. Experiment on the optimum sample-cocktail volume ratio, the influence of agitation and the diffusion of radon from vial were carried out.

  • PDF

The effect of liposomal cephalexin on the dry period treatment of bovine Staphylococcus aureus mastitis (젖소의 Staphylococcus aureus성 유방염에 대한 liposomal cephalexin 의 건유기 치료효과)

  • Shin, Jin-ho;Han, Hong-ryul
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.2
    • /
    • pp.251-258
    • /
    • 1992
  • Liposomal cephalexin was used m the dry period treatment of bovine mastitis due to Staphylococcus aureus. Liposomes were prepared by stable plurilamellar vesicle(SPLV) process. The shape and size of SPLVs were examined by transmission electron microscopy. The entrapping efficiency and stability of SPLVs were determined by high performance liquid chromatography or liquid scintillation counting. The size of SPLVs ranged from 0.1 to $4.01{\mu}m$ in diameter, with an entrapping efficiency of cephalexin of 25.8 %. The formulation of liposomal cephalexin was used for treatment were SPLV-entrapped cephalexin and free cephalexin with total cephalexin concentration of 250mg per quarters. All quarters were infused intramammarily at the end of lactation period by liposomal cephalexin, free cephalexin, or blank liposome with free cephalexin. The number of quarters cured by liposomal cephalexin(14/15 quarters, 93 %) was significantly higher than that by free cephalexin(7/15 quarters, 46%). or by blank liposome with free cephalexin(8/15 quarters, 53 % ) (p<0.05).

  • PDF