• Title/Summary/Keyword: liquid scintillation counting

Search Result 64, Processing Time 0.027 seconds

Mechanism of Quenching by Dimethylanilines in Liquid Scintillation Counting (Liquid Scintillation Counting 에서의 Dimethylaniline 에 依한 消光機構)

  • Lee, Ik-Choon
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.2
    • /
    • pp.43-46
    • /
    • 1964
  • Quenching constants, q, determined for N,N-dimethylanilines by liquid scintillation counting indicate that the quenching involves an energy transfer process to these compounds causing strong n-${\pi}$ interaction within the quencher molecule, which is then followed by an non-radiative degradation of the excitation energy to ground state.

  • PDF

A Rapid Method for the Measurement of the Absolute Activity of Carbon-14 in Pea Plant Tissue

  • Kendall, F.H.;Park, Chang-Kyu;Mer, C.L.
    • Applied Biological Chemistry
    • /
    • v.18 no.2
    • /
    • pp.56-60
    • /
    • 1975
  • A rapid method for the measurement of the absolute activity of carbon-14 in cotyledons and root of etiolated pea seedlings has been developed. Fresh tissue was frozen in liquid air, ground and suspended in gel phosphor and subjected to measurement for its radioactivity by liquid scintillation counter. Apparent activity of the suspended tissue sample calculated by counting efficiency value obtained by internal standardisation, was found to be related to absolute activity of the tissue, determined by flask combustion technique, by a constant factor. Once this factor is determined experimentally, analysis of C-14 lebelled tissue involves only fairly simple suspension counting by liquid scintillation counter. Present method appears to be applicable to other tissues tagged with C-14.

  • PDF

Study on the Radiocarbon Dating with Liquid Scintillation Counting (액체섬광계수법을 이용한 방사성탄소 연대측정법 연구)

  • Kim, Nak Bae;Woo, Hyung Joo;Hong, Wan;Cho, Soo Young
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.381-387
    • /
    • 1992
  • Optimum counting condition of a low level liquid scintillation counter for radiocarbon dating has been determined to minimize the contribution of tritium activity and get the highest FOM by the variation of scintillation solutions, scintillation solution to benzene ratio, and ${\beta}$-ray spectrum counting ranges. Under the condition, background count rate has been reduced to $2.26{\pm}0.03cpm$, and the maximum measurable age reached to about 40,000 years. And the practicality of counting system has been verified by the analysis of shell and peat samples.

  • PDF

Development of Movable Detection System for Efficiency Measurement in 3-PM Liquid Scintillation Counting

  • Hwang, H-Y;Kwak, S.I;Cho, Y.H;Byun, J.I;Lee, H.Y;Seo, J.S;Kwak, J.Y;Lee, J.M;Lee, K.B;Park, T.S;Chung, K.H;Lee, C.W
    • Nuclear Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.165-170
    • /
    • 2003
  • We developed an improved 3-PM liquid scintillation counting (3-PM LSC) method in which three detectors can be displaced to back and forth directions, and a data acquisition system being able to provide the values for all parameters required for the method. The detectors are entirely located in a 20-mm lead chamber of an inner diameter of 500 mm. A saw-toothed gear ties up all detectors so as to move them uniformly, up to 50 mm with unit of 1 mm. The data acquisition system was designed in an integrated circuit to perform the necessary works such as fast amplification, discrimination, coincidence and logic analysis. It generates values of nine parameters among twelve's generated in the 3-PH LSC method. The dead time of each counting channel is of extending type, valving from 10 to 100 $mutextrm{s}$. We measured the TDCR values with an unquenched liquid scintillation source 1"C by displacing the detectors with a step of 2.5 mm away from counting vial. Their values were derived on the range from 0.9 to 0.6. The extent is three times wider than those regions observed by applying the defocalization technique.ique.

A comparative study of different radiometric methodologies for the determination of 226Ra in water

  • Al-Hamarneh, Ibrahim F.;Almasoud, Fahad I.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.159-164
    • /
    • 2018
  • An evaluation of various radiometric methods to analyze $^{226}Ra$ in water has been employed on a set of 10 standard solutions of different concentrations in the range of $1-10Bq/L^{-1}$. The analysis was carried out using well-established procedures by means of gamma-ray, alpha-particle and liquid scintillation spectrometry. The feasibility of the various methods has been quantified in terms of relative standard error and percentage error. Correlations between the various methods have been presented and discussed. In general, good agreement was found in the results of various methodologies, which assures the accuracy of the methods and allows for the validation of instrumentation and procedures. Of the different methods adopted here, a combined procedure for the determination of $^{226}Ra$ along with $^{228}Ra$ using Quantulus 1220 ultra-low level background liquid scintillation counting gave the most accurate results.

Optimum conditions of benzene synthesis and liquid scintillation counting fir radiocarbon dating ($^14C$년대측정을 위한 벤젠 합성 및 액체섬광계측의 최적 조건)

  • Kang, Hyung-Tea;Nah, Kyung-Ym
    • 보존과학연구
    • /
    • s.15
    • /
    • pp.21-32
    • /
    • 1994
  • Optimum conditions for benzene synthesis and liquid scintillation counting have been studied for the determination of radiocarbon age. In benzene synthesis the carbon dioxide converted to benzene with high efficiency of 91%. Yields of each step with 10L of carbon dioxide were $CO_2$ $\rightarrow$$C_2H_2$(94%), $C_2H_2$$\rightarrow$$C_6H_6$(96%) and$CO_2$$\rightarrow$$C_6H_6$(91%), respectively. Benzene synthesized from oxalate was measured with purity of 95% by GC /MS. $\delta^13$(C$^13$C/$^12$C) of oxalate was measured to $-24.7\{textperthousand}$ by massspectrometer. For liquid scintillation counting of benzene sample low background and highest FOM were measured in 0.5 ml cocktail and 3 ml standard solution with the range of 15.4∼74.9 KeV window setting. Oxalate and background samples weremeasured to $28.7\pm0.12$cpm and $3.92\pm0.04$ cpm in 15.4∼74.9 KeV

  • PDF

A Study on the Analysis of 89Sr and 90Sr with Cerenkov Radiation and Liquid Scintillation Counting Method (첼렌코프광과 액체섬광계수법을 이용한 89Sr 및 90Sr 분석에 대한 연구)

  • Lee, Myung-Ho;Chung, Geun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • An accurate and simple analytical technique for $^{89}Sr$ and $^{90}Sr$, overcoming the demerits of the conventional method, has been developed with extraction chromatography and liquid scintillation counting. The Sr fraction was separated from hindrance elements with oxalate coprecipitation or cation exchange resin and purified with Sr-Spec column. With liquid scintillation counter, $^{89}Sr$ was measured by Cerenkov radiation method, and $^{90}Sr$ was measured by spectrum unfolding method. The developed radioactive strontium separation method was validated by application to the IAEA-reference material (IAEA-375, Soil) and radioactive waste samples.

Determination of $^{241}Pu$ in Environmental Samples Using Liquid Scintillation Counting System (액체섬광계수기를 이용한 환경시료중 $^{241}Pu$분석)

  • Lee, Myung-Ho;Hong, Kwang-Hee;Choi, Yong-Ho;Kim, Sang-Bog;Choi, Geun-Sik;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 1996
  • An optimized method for determining beta-emitting $^{241}Pu$ in the presence of alpha-emitting nuclides was developed using a liquid scintillation counting system. Pulse shape analysis (PSA) level was set using pulse-shape discrimination method and the $^{241}Pu$ counting channel was adjusted for maximum value of figure of merit using the 241pu standard source. The volume of scintillant was determined for the maximum value of counting efficiency. This optimized method has been applied to environmental samples to measure concentration of $^{241}Pu$ in soils and mosses. Also it has been identified the origin of Pu deposited in Korea from the activity ratio of $^{241}Pu/^{239,\;240}Pu$.

  • PDF

Tritium radioactivity estimation in cement mortar by heat-extraction and liquid scintillation counting

  • Kang, Ki Joon;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3798-3807
    • /
    • 2021
  • Tritium extraction from radioactively contaminated cement mortar samples was performed using heating and liquid scintillation counting methods. Tritiated water molecules (HTO) can be present in contaminated water along with water molecules (H2O). Water is one of the primary constituents of cement mortar dough. Therefore, if tritium is present in cement mortar, the buildings and structures using this cement mortar would be contaminated by tritium. The radioactivity level of the materials in the environment exposed to tritium contamination should be determined for their disposal in accordance with the criteria of low-level radioactive waste disposal facility. For our experiments, the cement mortar samples were heated at different temperature conditions using a high-temperature combustion furnace, and the extracted tritium was collected into a 0.1 M nitric acid solution, which was then mixed with a liquid scintillator to be analyzed in a liquid scintillation counter (LSC). The tritium extraction rate from the cement mortar sample was calculated to be 90.91% and 98.54% corresponding to 9 h of heating at temperatures of 200 ℃ and 400 ℃, respectively. The tritium extraction rate was close to 100% at 400 ℃, although the bulk of cement mortar sample was contaminated by tritium.

Quality Control of Radiation Counting Systems and Measurement of Minimum Delectable Activity (방사선 계측기의 품질관리 및 최소검출방사능 측정)

  • 송병철;한성심;김영복;지광용;손세철
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.419-424
    • /
    • 2004
  • Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the $\gamma$-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 Ops within $2{\sigma}$ confidence levels. The average alpha background level for the low background ${\alpha}{\beta}$ counting system was 0.31 cpm and the efficiency for alpha counting was 34.38%. The average beta background level for the ${\alpha}{\beta}$ counting system was 1,30 cpm and the efficiency for beta counting was 46.5%, The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the$\gamma$-spectrometer was found to be 3.2 Bq/$m\ell$ and 3.8 Bq/$m\ell$ for the liquid scintillation counter, and 20.5 and 23.0 Bq/$m\ell$, respectively for the $\alpha$ and $\beta$ counting system.

  • PDF