Simultaneous Measurement of Liquid-level, Concentration and Temperature of a Urea Tank using Ultrasonic and Electrical Conductivity Sensors (초음파와 전기전도 센서를 이용한 우레아 탱크 수위, 농도 및 온도의 동시 측정 방안)

  • Choi, Byungchul;Kim, Taewook
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.71-78
    • /
    • 2017
  • The purpose of this study is to propose the basic data for the development of a sensor capable of simultaneously measuring the liquid-level, concentration and temperature of a urea tank using ultrasonic and electrical conductivity sensors for diesel vehicles with a urea-SCR system. It was found that the liquid-level of the urea tank using the ultrasonic sensor showed a good linearity with the actual liquid-level, and the urea concentration maintained good linearity in the range of 32.5 wt% to 10 wt%. It was an effective measurement of urea concentration to use the electrical conductivity sensor in the temperature range of $-10{\sim}22^{\circ}C$ and to use the ultrasonic sensor at $22^{\circ}C$ or more. Simultaneous measurement of concentration, liquid-level and temperature of the urea tank will be possible by attaching the electrical conductivity sensor and the ultrasonic sensor (split-type) to one sensor together.

Experimental Study on Micro PIV Measurement using a Micro Liquid Lens (마이크로 유체렌즈를 이용한 마이크로 PIV 측정에 관한 실험적 연구)

  • Jeong, S.R.;Dang, T.D.;Choi, J.H.;Kim, G.M.;Park, C.W.
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.3
    • /
    • pp.22-28
    • /
    • 2010
  • In the present study, we performed the velocity field measurement in a microchannel using a focal length variable micro liquid lens. The liquid lens is used as a beam expander in a micro-PIV system to acquire the scatter image of the seeded particle. A thin film-type micro liquid lens was made of PDMS material and it was attached on top of the 700-micron-wide working fluid supply channel trench. As a result, the focal length and contact angle of the liquid lens changed with variations in applied pressure.

A Study on the Thickness Characteristics of the Liquid Sheet Formed by an Impinging Jet Onto a Wall (벽 충돌 제트로 생성되는 액막의 두께 분포 특성 연구)

  • J. S. Lee;T. Y. Lee;J. M. Jo;B. S. Kang
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.68-74
    • /
    • 2023
  • In this study, the thickness of the liquid sheet formed by a low speed impinging jet onto a wall was measured by the direct contact method. The spatial distribution characteristics of the sheet thickness in the radial and circumferential directions, and the effects of jet velocity and liquid viscosity were analyzed. The measurement results were compared with the theoretical predictions for two impinging jets. The wavy surface was observed for low viscosity water, but not for high viscosity glycerol solutions. The sheet thickness decreased as the circumferential angle or the distance from the impinging point increased. The sheet thickness increased as the liquid viscosity increased. Comparison with the theoretical predictions showed some differences from the measurement results.

Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

  • Seo, Mansu;Park, Hana;Yoo, DonGyu;Jung, Youngsuk;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.64-69
    • /
    • 2014
  • Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid propellant stored in space is proven with good measurement accuracy.

The Birefringence measurement of liquid crystal ZLI-1253

  • Cho, Chang-Ho;Jung, Gyoung-Geun;Lee, Tae-Jong;Kim, Chil-Min;Lee, Chul-Se
    • The Journal of Natural Sciences
    • /
    • v.1
    • /
    • pp.7-14
    • /
    • 1987
  • The birefringence measurement of liquid crystal ZLI-1253 dependent upon the spectral response and the applied voltage have been studied using He-Ne laser and Ar-ion laser.

  • PDF

Measurement System of Dynamic Liquid Motion using a Laser Doppler Vibrometer and Galvanometer Scanner (액체거동의 비접촉 다점측정을 위한 레이저진동계와 갈바노미터스캐너 계측시스템)

  • Kim, Junhee;Shin, Yoon-Soo;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.5
    • /
    • pp.227-234
    • /
    • 2018
  • Researches regarding measurement and control of the dynamic behavior of liquid such as sloshing have been actively on undertaken in various engineering fields. Liquid vibration is being measured in the study of tuned liquid dampers(TLDs), which attenuates wind motion of buildings even in building structures. To overcome the limitations of existing wave height measurement sensors, a method of measuring liquid vibration in a TLD using a laser Doppler vibrometer(LDV) and galvanometer scanner is proposed in this paper: the principle of measuring speed and displacement is discussed; a system of multi-point measurement with a single point of LDV according to the operating principles of the galvanometer scanner is established. 4-point liquid vibration on the TLD is measured, and the time domain data of each point is compared with the conventional video sensing data. It was confirmed that the waveform is transformed into the traveling wave and the standing wave. In addition, the data with measurement delay are cross-correlated to perform singular value decomposition. The natural frequencies and mode shapes are compared using theoretical and video sensing results.

Measurement of Heat Flux in Rocket Combustors Using Plug-Type Heat Flux Gauges

  • Kim, Min Seok;Yu, I Sang;Kim, Wan Chan;Shin, Dong Hae;Ko, Young Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.4
    • /
    • pp.788-796
    • /
    • 2017
  • This paper proposes a new measurement method to improve the shortcomings of an existing integral method for measuring heat flux in plug-type heat flux gauges in the high-temperature and high-pressure environments of liquid-rocket combustors. Using the existing integral measurement method, the calculation of the surface area for the heat flux in the gauge exhibits error in relation to the actual surface area. To solve this problem, transient profiles obtained from ANSYS Fluent were used to calculate unsteady heat flux as it adjusted to the measured temperature. First, a heat flux gauge was designed and manufactured specifically for use in the high-temperature and high-pressure conditions that are similar to those of liquid rocket combustors. A calibration test was performed to prove the reliability of the manufactured gauge. Then, a combustion experiment was conducted, in which the gauge was used to measure unsteady heat flux in a liquid rocket combustor that used kerosene and liquid oxygen as propellants. Reasonable heat flux values were obtained using the gauge. Therefore, the proposed measurement method is considered to offer significant improvement over the existing integral method.

Complex Permittivity Measurement of Reference Liquids using the Slotted Coaxial Line at Mobile Communication Frequencies

  • Kim, Jeong-Ho;Gimm, Youn-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.3
    • /
    • pp.97-101
    • /
    • 2004
  • Complex permittivities of reference liquids were measured by a liquid holder of slotted coaxial line with a movable probe at mobile communication frequencies. The validity of the liquid measurement system was checked by experimental tests with the reference liquids proposed in IEEE Std. 1528-200X or IEC 106/61/CDV.

A Rapid Method for the Measurement of the Absolute Activity of Carbon-14 in Pea Plant Tissue

  • Kendall, F.H.;Park, Chang-Kyu;Mer, C.L.
    • Applied Biological Chemistry
    • /
    • v.18 no.2
    • /
    • pp.56-60
    • /
    • 1975
  • A rapid method for the measurement of the absolute activity of carbon-14 in cotyledons and root of etiolated pea seedlings has been developed. Fresh tissue was frozen in liquid air, ground and suspended in gel phosphor and subjected to measurement for its radioactivity by liquid scintillation counter. Apparent activity of the suspended tissue sample calculated by counting efficiency value obtained by internal standardisation, was found to be related to absolute activity of the tissue, determined by flask combustion technique, by a constant factor. Once this factor is determined experimentally, analysis of C-14 lebelled tissue involves only fairly simple suspension counting by liquid scintillation counter. Present method appears to be applicable to other tissues tagged with C-14.

  • PDF

A Comparison of Collection Concentrations Based on Airborne Toluene Diisocyanates Measurement Methods (공기 중 Toluene diisocyanates 측정방법에 따른 포집농도 비교)

  • Park, Hyung-Sung;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.341-347
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the differences in airborne TDI concentrations based on the filter collection method and liquid collection method and to compare airborne TDIs concentrations by sampling method change when using the filter collection method in the spray-painting process. Methods: For the sample measurement, the filter collection method(OSHA#42) and liquid collection method(NIOSH#5522) were used; for the sampling method, the full-period single sampling and full-period consecutive sampling methods were used. The samples were collected in spray-painting and drying process locations. Results: In all samples collected from the spray-painting and drying process locations through the filter collection and liquid collection methods, greater amounts of 2,6-TDI than 2,4-TDI were detected. When the TDI collection concentrations based on the sampling methods were compared, the concentrations of 2,4-TDI and 2,6-TDI collected by the consecutive sampling method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the single sampling method for both the filter collection method and liquid collection method used in the spray-painting process. These differences were statistically significant. Conclusions: When TDI collection concentrations based on the sample measurement methods were compared, the concentration of 2,4-TDI and 2,6-TDI collected through the liquid collection method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the filter collection method, and the differences were statistically significant. In the drying process, no difference was shown in the collection concentrations of 2,4-TDI and 2,6-TDI with the two measurement methods.