• Title/Summary/Keyword: liquid flow

Search Result 2,932, Processing Time 0.028 seconds

Simulation of oxygen mass transfer in fuel assemblies under flowing lead-bismuth eutectic

  • Feng, Wenpei;Zhang, Xue;Chen, Hongli
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.908-917
    • /
    • 2020
  • Corrosion of structural materials presents a critical challenge in the use of lead-bismuth eutectic (LBE) as a nuclear coolant in an accelerator-driven system. By forming a protective layer on the steel surfaces, corrosion of steels in LBE cooled reactors can be mitigated. The amount of oxygen concentration required to create a continuous and stable oxide layer on steel surfaces is related to the oxidation process. So far, there is no oxidation experiment in fuel assemblies (FA), let alone specific oxidation detail information. This information can be, however, obtained by numerical simulation. In the present study, a new coupling method is developed to implement a coupling between the oxygen mass transfer model and the commercial computational fluid dynamics (CFD) software ANSYS-CFX. The coupling approach is verified. Using the coupling tool, we study the oxidation process of the FA and investigate the effects of different inlet parameters, such as temperature, flow rate on the mass transfer process.

Numerical study of oxygen transport characteristics in lead-bismuth eutectic for gas-phase oxygen control

  • Wang, Chenglong;Zhang, Yan;Zhang, Dalin;Lan, Zhike;Tian, Wenxi;Su, Guanghui;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2221-2228
    • /
    • 2021
  • One-dimensional oxygen transport relation is indispensable to study the oxygen distribution in the LBE-cooled system with an oxygen control device. In this paper, a numerical research is carried out to study the oxygen transport characteristics in a gas-phase oxygen control device, including the static case and dynamic case. The model of static oxygen control is based on the two-phase VOF model and the results agree well with the theoretical expectation. The model of dynamic oxygen control is simplified and the gas-liquid interface is treated as a free surface boundary with a constant oxygen concentration. The influences of the inlet and interface oxygen concentration, mass flow rate, temperature, and the inlet pipe location on the mass transfer characteristics are discussed. Based on the results, an oxygen mass transport relation considering the temperature dependence and velocity dependence separately is obtained. The relation can be used in a one-dimensional system analysis code to predict the oxygen provided by the oxygen control device, which is an important part of the integral oxygen mass transfer models.

Influence of Piston Bowl Geometry on Combustion of a Diesel/CNG Reactivity Controlled Compression Ignition Engine (디젤/천연가스 반응성제어 압축착화 엔진에서 피스톤 형상에 따른 연소 특성)

  • Kim, Hyunsoo;Kim, Wooyeong;Bae, Choongsik
    • Journal of ILASS-Korea
    • /
    • v.26 no.2
    • /
    • pp.57-66
    • /
    • 2021
  • The reactivity controlled compression ignition (RCCI) is the technology that provides two different types of fuel to the combustion chamber with the advantage of significantly reducing particulate matter and nitrogen oxides emissions. However, due to the characteristics of lean combustion, combustion efficiency is worsened. The conventional type of pistons for conventional diesel combustion (CDC) has mostly been used in the researches on RCCI. Because the pistons for CDC are optimized to enhance flow and target spray, the pistons are unsuitable for RCCI. In this study, a piston that is suitable for RCCI is designed to improve combustion efficiency. The new piston was designed by considering the factors such as squish geometry, bowl depth, and surface area. The experiment was carried out by fixing the energy supply to 0.9kJ/cycle and 1.5kJ/cycle respectively. The two pistons were quantitatively compared in terms of thermal efficiency and combustion efficiency.

Analytical Method Validation of (-)Epicatechin gallate in Penthorum chinense Pursh Extract using HPLC

  • Kwon, Jin Gwan;Jung, Yeon Woo;Seo, Changon;Hong, Seong Su;Lee, Ji Eun;Shin, Hyun Tak;Jung, Su Young;Choi, Chun Whan;Kim, Jin Kyu
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.100-100
    • /
    • 2019
  • This study attempted to establish a High Performance Liquid Chromatography (HPLC) analysis method for the determination of (-)-epicatechin gallate as a part of the quality control for the development of functional cosmetic materials from Penthorum chinense Pursh extracts. HPLC was performed on a Unison US-C18 column ($4.6{\times}250mm$, $5{\mu}m$) with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and methyl alcohol at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 280 nm. The HPLC method was performed in accordance with the International Conference on Harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation were 0.11 and 0.33 mg/mL, respectively. Calibration curves showed good linearity (r2 > 0.9999), and the precision of analysis was satisfied (less than 0.6%). Recoveries of quantified compounds ranged from 99.51 to 101.92%. This result indicates that the established HPLC method is very useful for the determination of marker compound in P. chinense Pursh extracts.

  • PDF

A Study on Heat Transfer Characteristics of the Outside Surface of Ambient Vaporizer (액화가스용 대기식 기화기의 외측 열전달 특성에 관한 연구)

  • Kang, Seung Mo;Seo, Dongmin;Ko, Dong Guk;Choi, Jun-Ho;Park, Woe-Chul;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.4
    • /
    • pp.5-10
    • /
    • 2017
  • This paper analyzed the heat transfer characteristics on the outer surface of the ambient air vaporizer which received the heat from the air through natural convection by using numerical and experimental methods. The working fluid was a liquid nitrogen. The experimental variables were the length (2,000 mm, 1,800 mm, 1,600 mm) and width of the vaporizer fin and the fluid flow ($6.7m^3/h$, $7.1m^3/h$, $7.5m^3/h$). Based on the temperature data from the experiments, the heat transfer coefficient was calculated. Numerical analyses were also conducted in order to find the heat transfer coefficient for the range of Nusselt number which was difficult to get the data from experiments. The correlation equation between Nusselt number and Rayleigh number were suggested using both the experimental and numerical data.

  • PDF

Cryopreservation of Hevea brasiliensis zygotic embryos by vitrification and encapsulation-dehydration

  • Nakkanong, Korakot;Nualsri, Charassri
    • Journal of Plant Biotechnology
    • /
    • v.45 no.4
    • /
    • pp.333-339
    • /
    • 2018
  • The mature zygotic embryos of the Hevea brasiliensis were cryopreserved through the use of the vitrification and encapsulation/dehydration techniques. In all the experiments, the zygotic embryos were pre-cultured for three days in the MS medium supplemented with 0.3 M sucrose before they were used for the cryopreservation technique. In the vitrification procedure, the effect of the plant vitrification solutions (PVS2 and PVS3) and exposure time were studied. The highest survival rate (88.87%) and regrowth (66.33%) were achieved when the precultured zygotic embryos were incubated in a loading solution for 20 minutes at $0^{\circ}C$. They were subsequently exposed to PVS2 for 120 minutes at $0^{\circ}C$ and plunged directly into liquid nitrogen. Cryopreservation by the encapsulation-dehydration method was successfully done by leaving the encapsulated zygotic embryos in a laminar flow for 4 hours prior to plunging into a LN. The survival rate and regrowth of the encapsulated zygotic embryos were 37.50% and 27.98%, respectively. The cryopreserved zygotic embryos were able to develop into whole plants.

A Sensitive and Rapid LC-MS/MS Method for Determination of Berberine in Human Plasma

  • Kim, Jae Hee;Mai, Xuan-Lan;Kim, Kyu Yeon;Sim, Min-Seok;Lee, So-Yeon;Seo, Hee-Won;Lee, Gunhee;Kim, Dae-Jung;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.56-60
    • /
    • 2019
  • Coptidis Rhizoma (CR) has been used widely in traditional medicine to treat common diseases. This study aimed to develop a high-sensitivity liquid chromatography-tandem mass (LC-MS) spectrometry method for the evaluation of the pharmacokinetics of a new natural product that contain CR extract with the main bioactive compound, berberine, at trace concentrations. Human plasma samples were pretreated with methanol by a protein precipitation method. Berberine was analyzed on a Kinetex C18 column ($2.1mm{\times}50mm$, $100{\AA}$, $1.7{\mu}m$) using a mobile phase of 10 mM ammonium formate/0.1% formic acid in water (A) and acetonitrile (B) (50:50, v/v) with a flow rate of 0.25 mL/min. The analyte was detected by using electrospray ionization in positive mode with multiple reaction monitoring (MRM). The method was sensitive, with a lower limit of quantification of 1 pg/mL, which has not been previously obtained. The method was validated (over the range of 1-50 pg/mL) and applied successfully for the pharmacokinetic study of human plasma samples.

Microstructure and Mechanical Properties of Pure Titanium Processed using Friction Stir Welding (순수 타이타늄의 기계적 특성에 미치는 마찰 교반 용접 공정 조건의 영향)

  • Lee, Y.J.;Choi, A.;Lee, S.J.;Fujii, Hidetoshi;Shin, S.E.;Lee, D.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.32 no.3
    • /
    • pp.124-130
    • /
    • 2019
  • Friction stir welding is one of the interesting welding methods for titanium and its alloy which proceeds with plastic flow due to thermo-mechanical stirring and friction heat. Solid-state welding can solve severe problems such as high-temperature oxidation, interstitial oxygen diffusion and grain coarsening by liquid-state welding. Dynamic recrystallization and grain refinement can vary significantly with the plunging load and rotational speed of tool during friction stir welding, and suitable process conditions must be optimized to obtain microstructure and better mechanical characteristics. Suitable FSW conditions were 1000 kg of plunging load and 200 rpm of rotational speed and it showed YS 270 MPa, UTS 332.1 MPa, and El 17.3%, which were very similar to those of wrought titanium sheet.

Removal of Flooding in a PEM Fuel Cell at Cathode by Flexural Wave

  • Byun, Sun-Joon;Kwak, Dong-Kurl
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.104-114
    • /
    • 2019
  • Energy is an essential driving force for modern society. In particular, electricity has become the standard source of power for almost every aspect of life. Electric power runs lights, televisions, cell phones, laptops, etc. However, it has become apparent that the current methods of producing this most valuable commodity combustion of fossil fuels are of limited supply and has become detrimental for the Earth's environment. It is also self-evident, given the fact that these resources are non-renewable, that these sources of energy will eventually run out. One of the most promising alternatives to the burning of fossil fuel in the production of electric power is the proton exchange membrane (PEM) fuel cell. The PEM fuel cell is environmentally friendly and achieves much higher efficiencies than a combustion engine. Water management is an important issue of PEM fuel cell operation. Water is the product of the electrochemical reactions inside fuel cell. If liquid water accumulation becomes excessive in a fuel cell, water columns will clog the gas flow channel. This condition is referred to as flooding. A number of researchers have examined the water removal methods in order to improve the performance. In this paper, a new water removal method that investigates the use of vibro-acoustic methods is presented. Piezo-actuators are devices to generate the flexural wave and are attached at end of a cathode bipolar plate. The "flexural wave" is used to impart energy to resting droplets and thus cause movement of the droplets in the direction of the traveling wave.

PILLAR: Integral test facility for LBE-cooled passive small modular reactor research and computational code benchmark

  • Shin, Yong-Hoon;Park, Jaeyeong;Hur, Jungho;Jeong, Seongjin;Hwang, Il Soon
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3580-3596
    • /
    • 2021
  • An integral test facility, PILLAR, was commissioned, aiming to provide valuable experimental results which can be referenced by system and component designers and used for the performance demonstration of liquid-metal-cooled, passive small modular reactors (SMRs) toward their licensing. The setup was conceptualized by a scaling analysis which allows the vertical arrangements to be conserved from its prototypic reactor, scaled uniformly in the radial direction achieving a flow area reduction of 1/200. Its final design includes several heater rods which simulate the reactor core, and a single heat exchanger representing the steam generators in the prototype. The system behaviors were characterized by its data acquisition system implementing various instruments. In this paper, we present not only a detailed description of the facility components, but also selected experimental results of both steady-state and transient cases. The obtained steady-state test results were utilized for the benchmark of a system code, achieving a capability of accurate simulations with ±3% of maximum deviations. It was followed by qualitative comparisons on the transient test results which indicate that the integral system behaviors in passive LBE-cooled systems are able to be predicted by the code.