• Title/Summary/Keyword: liquid flow

Search Result 2,932, Processing Time 0.029 seconds

Separation of Hydrocarbon Mixture Using (O/W)/O Emulsion Liquid Membrane ((O/W)/O 에멀젼형 액막을 이용한 탄화수소 혼합물의 분리)

  • Jeong, M.C.;Park, H.Y.;Oh, J.T.;Kim, J.K.;Shin, M.H.;Kim, W.S.
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.763-770
    • /
    • 1997
  • The separation of benzene-cyclohexane mixture using (O/W)/O emulsion liquid membrane was studied. The operating parameters which can affect the selectivity, benzene yield, and emulsion size distribution were examined and determined by the batch type operation. The unsteady state and steady state extraction behavior in continuous pulse stirred reactor(CPSR) were verified. The optimum conditions for benzene selectivity and yield in batch operation were as follows; emulsion mixing intensity 4000 rpm, Tween 80 concentration 0.4%, volume ratio of membrane phase to internal phase 0.75, volume ratio of dispersed phase to continuous phase 0.5, and permeation time 10 minutes, As impeller speed increased and the microdrop holdup decreased, the Sauter mean diameter decreased. Turbulence damping parameter of modified Calabrease correlation considering microdrop holdup was 2.28. The optimum conditions of continuous operation were as follows; agitation speed 300 rpm, pulse frequence 2 times/sec, flow rate of continuous phase 30ml/min, and flow rate of emulsion phase 12.0ml/min.

  • PDF

Removal of Cobalt ion by Foam Flotation(I): Precipitate Flotation (거품부상법을 이용한 코발트이온제거(I): 침전부상법)

  • Jung, In Ha;Park, Hee Seoung;Moon, Je Sun;Yim, Sung Paal;Bae, Ki Kwang
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.41-45
    • /
    • 1999
  • Simulated liquid waste containing 50 ppm cobalt ion was treated by precipitate flotation using the surfactant of sodium lauryl sulfate. The effects of initial cobalt ion concentration, pH, surfactant concentration, removal time, gas flow rate and foreign ions were estimated on removal efficiency. 35% $H_2O_2$ was added for pre-treatment stage before precipitate flotation. As the result of pre-treatment, optimum removal pH and the pH of treated water being discharged were lowed and optimum removal pH range was broadened. For the result of this experiment, 99.8% removal efficiency was obtained at the condition of 50ppm of initial cobalt ion concentration, pH 9.5, 70 mL/min of gas flow rate, and 30 min of removal time. Attraction between precipitate and surfactant was supposed to be influenced by solubility and chemical affinity among species in sloution as well as zeta potential. The influence of foreign ions such as, $NO_3{^-}$, ${SO_4}^{-2}$, $Na^+$, $Ca^{+2}$ on the removal efficiency was also observed. Removal efficiency by precipitate flotation containing 0.1 M of ${SO_4}^{-2}$ ion decreased to 90% due to the decrease of zeta potential and interruption of precipitation.

  • PDF

Copper Recovery from Waste Water of Electronic Industry in a Fluidized Bed Reactor (유동층 반응기에서 전자 공장폐수로부터 동의 회수)

  • Lim, Wan-Mook;Woo, Kwang-Jae;Cho, Yong-Jun;Kang, Yong;Won, Chang-Whan;Kim, Sang-Done
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.482-488
    • /
    • 1997
  • Copper recovery from waste water of electronic industry has been conducted effectively in a fluidized bed reactor. Initial concentration of copper in the waste water, liquid flow rate in the reactor, reaction temperature and time and current density between the cathode and anode in the reactor have been selected as operating variables. The effects of operating variables on the recovery of copper have been studied. It has found that the copper resolved in the waste water can be recovered continuously by means of a fluidized bed reactor The recovery of copper decreased with an increase in the initial concentration of copper in the waste water, while it increased with increasing reaction time and current density, however, it exhibited its maximum value with the variations of liquid flow rate and reaction temperature. The optimum reaction condition to maintain the copper recovery around 85% is as follows ; $X_o=3wt%$, $U_L=0.5cm/s$, $T=25^{\circ}C$, $I=7A/dm^2$ and t=2hrs within this experimental condition.

  • PDF

Study on 222Rn reduction rate in boiling groundwater (가열에 의한 지하수 중 222Rn 제거율 고찰)

  • Kim, MoonSu;Kim, Hyun-Koo;Park, Sun-Wha;Kim, Hyoung-Seop;Ju, Byoung-Kyu;Kim, Dong-Su;Cho, Sung-Jin;Yang, Jae-Ha;Kwon, Oh-Sang;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.353-360
    • /
    • 2015
  • Boiling is an efficient removal method to reduce radon in groundwater when ventilating indoor air. 13 groundwater samples with various radon concentrations were used to evaluate the reduction rate of radon with heating temperature and time. The groundwater samples were obtained by Bladder pump and on-situ measurements such as dissolved oxygen (DO) and hydrogen concentration (pH) and so on were carried out by a flow cell system isolated from the ambient atmosphere environment. All samples for measuring radon in groundwater were analyzed by liquid scintillation counter (LSC). The experiment result showed that increasing groundwater temperature enhanced radon removal rate but the initial radon concentration with high level lowered the removal rate. This means that radon reduction in groundwater by heating needs more heating energy and longer heating time with radon concentrations. Radon removal rate in groundwater, therefore, mainly depends on the initial radon concentration, heating temperature, and heating time.

A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber (Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰)

  • Ryu, Woo-Jung;Han, Keun-Hee;Choi, Won-Kil;Lee, Jong-Sub;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.795-800
    • /
    • 2009
  • In this study, the $CO_2$ removal characteristics of the Vortex tube type absorbtion apparatus were investigated to enhance the compactness of $CO_2$ absorption process and to reduce the amount of absorbing solution of the $CO_2$ separation process. The Vortex tube with the diameter of 17 mm and the length of 250mm was introduced in the experimental apparatus to treat $20Nm^3/hr$ of $CO_2$ containing flue gas. The flue gases for experiments containing 11~13 vol% of $CO_2$ were supplied from the coal-firing CFBC power plant with 12 ton/hr of steam producing capacity. The mixed solutions of 20 wt% of MEA as base solution with the adding solutions like HMDA, AMP and KOH were used as absorbents. The experiments were executed under the various conditions like the absorbing solution concentrations in the range of 20 to 50 wt%, the flow rate of $CO_2$ containing flue gases in the range of 6 to $15Nm^3/hr$ and the flow rate of absorbing solution in the range of 1.0 to 3.0 l/min. As a results, the $CO_2$ removal efficiency of mixed absorbent of 20 wt% of MEA with HMDA was remarkable. From this study, we concluded that the efficient separation of $CO_2$ from flue gases using the features of the Vortex tube type absorbing unit for gas/liquid contact and the separation of gas/liquid be possible. But more works are needed to increase the $CO_2$ removal efficiency of Vortex tube process.

An Experimental Study on the Improvement of Foam Fire-Extinguishing System's Mixing Ratios by Expanding the Cross Sectional Area of the Stock Solution Inhaling Piping (원액흡입배관 단면적 확장에 의한 포 소화설비 혼합비 개선에 관한 실험적 연구)

  • Yun, Ki-Jo;Jang, Kyung-Nam;Baek, Eun-Sun;Park, Bong-Rae;Park, Hee-Joog
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.30-37
    • /
    • 2013
  • The ultimate purpose of the present study is to secure a effective method for foam liquid discharge when the mixing ratio deviates from the permissible range due to a decrease in the bypass flow rate resulting from a decrease in the cross sectional area of the foam liquid piping ranging from the branching header of one foam proportioner to the branching headers of multiple branching foam fire-extinguishing systems in the region for fire extinguishing and then to the standpipe at the lower part of the storage tank when a fire occurred in a combustible tank. To this end, the cause of mixing ratio variations following changes in the flow rates of existing foam fire extinguishing systems was analyzed, methods for compensation for constant mixing ratios were investigated, and it was proved that metering orifice replacements that could expand the cross sectional area of the stock solution inhaling piping was the most effective way for the improvement of form fire extinguishing systems' mixing ratios through foam proportioner venturi, foam chamber orifice, and metering orifice replacement experiments.

Effect of Clamping Pressure on Surface Properties of Gas Diffusion Layer in PEFCs (체결압이 고분자연료전지 기체확산층의 표면성질에 미치는 영향)

  • Ahn, Eun-Jin;Park, Gu-Gon;Yoon, Young-Gi;Park, Jin-Soo;Lee, Won-Yong;Kim, Chang-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.306-310
    • /
    • 2007
  • Characteristics of GDL (Gas Diffusion Layer) mainly determine the gas diffusion and water removal in a cell, thereby changing the performance and affecting durability of PEFC. To optimize the water management and understand the two phase flow in a GDL, it is important to study the behaviors of GDL micro structure under the real operating condition. In the clamped condition of cell, the GDL beneath the rib is more compressed than beneath the channel. Many researches on physical, electrochemical, mechanical behaviors of gas diffusion layer has been conducted. However, changes in surface properties under clamped condition have rarely studied. In present study, the morphology of broken connections of carbon fibers and detachment of PTFE coatings on the fibers were shown from the microscopic observations. In addition, changes in wetting properties of GDL by compression were investigated by using XPS and liquid uptake methods. The hydrophobic characteristics of GDL surface beneath the rib of the flow field plate are changed due to the deformation of micro structure.

Removal of Cobalt Ions by Precipitate Foam Flotation (침전 포말부선법에 의한 Cobalt Ion의 제거)

  • 정인하;이정원
    • Resources Recycling
    • /
    • v.7 no.3
    • /
    • pp.11-16
    • /
    • 1998
  • Simulated waste liquid containing 50 ppm cobalt ion was t$\xi$sted by precipitate flotation using a sodium lauryl sulfate as a c collector. The effects of initial cobalt ion concentration, pH, surfactant concentration, flotation time, gas flow rate and foreign i ions on removal efficiency of cobalt ion were studied. Pretreatment of the waste liquid with 35% $H_2O_2$, prior to precipitate f flotation made shin of optimal flotation pH from the strong alkalinity to weak alkaline range and made a favorable flotation of c cobalt ion in wide range of pH. For the result of this experiment, 99.8% removal efficiency was obtained on the conditions of initial coball ion concentration 50 ppm, pH 9.5 gas flow rate 70 mllmin, flotation time 30 min. The simulate ion was fanned t to be the most harmful ion against removal of cobalt by precipitate flotation of the species which were tested The presence of 0.1 M of $SO_4^{2-}$ ion decreased remo,때 $\xi$폐iciency of cobalt to 90% while the cobalt were almost entirely removed in the a absence of sulfate ion.

  • PDF

Metalorganic Chemical Vapor Deposition of Copper Films on TiN Substrates Using Direct Liquid Injection of (hfac)Cu(vtmos) Precursor ((hfac)Cu(vtmos)의 액체분사법에 의한 TiN 기판상 구리박막의 유기금속 화학증착 특성)

  • Jun, Chi-Hoon;Kim, Youn-Tae;Kim, Dai-Ryong
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1196-1204
    • /
    • 1999
  • We have carried out copper MOCVD(metalorganic chemical vapor deposition) onto the reactive sputtered PVD-TiN and rapid thermal converted RTP-TiN substrates using direct liquid injection for effective delivery of the (hfac)Cu(vtmos) [$C_{10}H_{13}O_{5}CuF_{6}$Si: 1,1,1,5,5,5-hexafluoro-2,4- pentadionato (vinyltrimethoxysilane) copper (I)] precursor. Especially, the influences of deposition conditions and the substrate type on growth rate, crystal structure, microstructure, and electrical resistivity of copper deposits have been discussed. It is found that the film growth with 0.2ccm precursor flow rate become mass-transfer controlled up to Ar flow rate of 200sccm and pick-up rate controlled at a vaporizer above 1.0Torr reactor pressure. The surface-reaction controlled region from 155 to 225$^{\circ}C$ at 0.6Torr reactor pressure results in the apparent activation energies of 12.7~14.1kcal/mol, and above 224$^{\circ}C$ the growth rate with $H_2$ addition could be improved compared to the pure Ar carrier. The Cu/RTP-TiN structures which have high copper nucleation density in initial stage of growth show more pronounced (111) preferred orientations and lower electrical resistivities than those on PVD-TiN. The variation of electrical resistivity with substrate temperature reflects the three types of film microstructure changes, showing the lowest value for the deposit at 165$^{\circ}C$ with small grains of good contacts.

  • PDF

Study on Three-Dimensional Analysis of Agricultural Plants and Drone-Spray Pesticide (농작물을 위한 드론 분무 농약 살포의 3차원 분석에 관한 연구)

  • Moon, In Sik;Kown, Hyun Jin;Kim, Mi Hyeon;Chang, Se Myong;Ra, In Ho;Kim, Heung Tae
    • Smart Media Journal
    • /
    • v.9 no.4
    • /
    • pp.176-186
    • /
    • 2020
  • The size and shape of crops are diverse, and the growing environment is also different. Therefore, when one uses a drone to spray pesticides, the characteristics of each crop must be considered, and flight conditions such as the flight height and forwarding velocity of the drone should be changed. The droplet flow of pesticides is affected by various flight conditions, and a large change occurs in the sprayed area. As a result, an uneven distribution of liquid may be formed at the wake, and the transport efficiency will be decreased as well as there would be a risk of toxic scatter. Therefore, this paper analyzes the degree of distribution of pesticides to the crops through numerical analysis when pesticide is sprayed onto the selected three crops with different characteristics by using agricultural drones with different flight conditions. On the purpose of establishing a guideline for spraying pesticides using a drone in accordance with the characteristics of crops, this paper compares the amount of pesticides distributed in the crops at the wake of nozzle flow using the figure of merit, and the sum of transported liquid rate divided by the root mean square of the probability density function.