• 제목/요약/키워드: liquid chromatography-mass spectrometry (LC-MS)

검색결과 458건 처리시간 0.04초

Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Lithospermic Acid B in Rat Serum

  • Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Kim, Youn-Chul;Sohn, Dong-Hwan;Lee , Hye-Suk
    • Archives of Pharmacal Research
    • /
    • 제27권12호
    • /
    • pp.1202-1206
    • /
    • 2004
  • A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/ MS) method for the determination of lithospermic acid B (LSB) in rat serum was developed. LSB and internal standard, 7-hydroxy-3-phenyl-chromen-4-one (HPC) were extracted from rat serum with methyl-tert-butyl ether at acidic pH and analyzed on a Luna $C_8$ column with the mobile phase of acetonitrile-ammonium formate (10 mM, pH 6.5) (50:50, v/v). The analytes were detected using a negative electrospray ionization tandem mass spectrometry in the multiple- reaction-monitoring mode. The standard curve was linear $(r^2 = 0.997)$ over the concentration range of 10.0-500 ng/mL. The coefficient of variation and relative error for intra- and interassay at three QC levels were 1.1~6.2% and -10.3~-2.7%, respectively. The recovery of LSB from serum sample ranged from 73.2 to 79.5%, with that of HPC (internal standard) being 75.1 %. The lower limit of quantification for LSB was 10 ng/mL using 50 ${\mu}L$ of serum sample.

Development of a Sensitive Analytical Method of Polynemoraline C Using LC-MS/MS and Its Application to a Pharmacokinetic Study in Mice

  • Pang, Minyeong;Lee, Jaehyeok;Jeon, Ji-Hyeon;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • 제12권4호
    • /
    • pp.200-205
    • /
    • 2021
  • Polynemoraline C, a pyridocoumarin alkaloid, exhibits anticholinergic, anti-inflammatory, antitumor, and antimicrobial activities. A sensitive analytical method of polynemoraline C in mouse plasma was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Polynemoraline C and 13C-caffeine (internal standard) in mouse plasma were extracted using a liquid-liquid extraction method coupled with ethyl acetate. This extraction method resulted in high and reproducible extraction recovery in the range of 73.49%-77.31% with no interfering peaks around the peak retention time of polynemoraline C and 13C-caffeine. The standard calibration curves for polynemoraline C were linear over the range of 0.5-200 ng/mL with r2 > 0.985. The accuracy, precision, and the stability of the data were within acceptable limits on the FDA guideline. After intravenous and oral administration of polynemoraline C at doses of 5 and 30 mg/kg, respectively, the present method was successfully applied to the pharmacokinetic study of polynemoraline C. Polynemoraline C in mouse plasma showed a multi-exponential elimination pattern with a high volume of distribution values. This compound's absolute oral bioavailability was found to be 17.0%. Polynemoraline C's newly developed LC-MS/MS method can be used for further studies on the efficacy, toxicity, and biopharmaceutics of polynemoraline C, as well as its pharmacokinetic studies.

Determination of 11 Illicit Compounds in Dietary Supplements Using High-Performance Liquid Chromatography and Liquid Chromatography-Tandem Mass Spectrometry

  • Shin, Dasom;Kang, Hui-Seung;Kim, Hyung-soo;Moon, Guiim
    • 한국식품위생안전성학회지
    • /
    • 제35권4호
    • /
    • pp.326-333
    • /
    • 2020
  • 본 연구는 불법적으로 식품에 사용될 수 있는 부정물질 11종에 대한 안전관리 강화를 위해 정량 및 정성 분석이 가능한 HPLC-DAD와 LC-MS/MS를 검증하기 위해 수행되었다. 확립된 시험법은 AOAC 가이드라인에 따라 직선성, 정밀성, 정량한계 및 회수율 등을 통해 유효성을 확인하였다. 본 실험에서 정량한계를 포함하여 검량선을 작성하였고, 모두 0.99 이상의 직선성을 확인하였다. 또한 정확성은 LC (90.0-106%), LC-MS/MS (83.0-114%) 이고, 정밀도는10% 이하로 재현성이 우수하였다. 확립된 시험법은 식품 중 부정물질 안전관리 및 모니터링에 활용될 것으로 사료된다.

LC/MS/MS를 이용한 수중의 카바릴·유기인계 농약 동시분석 (Simultaneous determination of carbaryl & organophosphorous pesticides in water by liquid chromatography-tandem mass spectrometry)

  • 박근영;신정철;표동진
    • 분석과학
    • /
    • 제31권1호
    • /
    • pp.39-46
    • /
    • 2018
  • 온라인 고체상 추출을 이용한 LC/MS/MS를 사용하여 carbaryl과 유기인계 농약 7 종을 동시에 분석하는 방법을 확립하였다. 분석 대상농약은 carbaryl, diazinon, methyl-demeton, fenitrothion, malathion, parathion, phenthoate, EPN 등 8 종이다. 본 연구에서는 온라인 고체상 추출과 LC/MS/MS의 ESI positive mode로 전처리 없이 물 시료 $500{\mu}L$를 직접 주입하여 10분안에 분석하였다. 농약 8 종의 회수율은 86.8~100 % 였고, 정확도는 90.6~98.8 %로 90 %이상이었고, 정밀도는 1.3~5.2 %로 나타났으며 검출한계 및 정량한계는 각각 $0.05{\sim}0.28{\mu}g/L$, $0.16{\sim}0.89{\mu}g/L$ 였다. $0.5{\mu}g/L$에서 $8.0{\mu}g/L$까지 다섯 개의 농도로 검량선을 작성한 결과 모든 물질의 상관계수(r2)가 0.99이상을 나타냈다. 방법의 유효성 평가를 한 결과 모든 내용에서 적합하므로확립한 분석방법으로 수질 시료에서 농약을 조사한 결과 모두 검출되지 않았다.

Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry

  • Jang, Haejong;Mai, Xuan-Lan;Lee, Gunhee;Ahn, Jae Hyoung;Rhee, Jongsook;Truong, Quoc-Ky;Vinh, Dinh;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제9권4호
    • /
    • pp.95-99
    • /
    • 2018
  • An innovative, simple, and rapid assay method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the simultaneous determination of eight statin drugs in human urine. A simple sample clean-up procedure using the "dilute and shoot" (DAS) approach enabled a fast and reliable analysis. The influence of the dilution factor was investigated to ensure detectability and reduce the matrix effect. Chromatographic separation was performed on a Phenomenex Kinetex C18 column ($50{\times}3.0mm$ i.d., $2.6{\mu}m$) using an elution gradient of mobile phase A composed of 0.1% acetic acid, and mobile phase B composed of acetonitrile, at a flow rate of 0.35 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using electrospray ionization in positive ion mode. The total chromatographic run time was 15 min. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy, precision, and stability. The present method was successfully applied to the analysis of Rosuvastatin in urine samples after oral administration to healthy human subjects.

Mass Spectrometry-Based Metabolite Profiling and Bacterial Diversity Characterization of Korean Traditional Meju During Fermentation

  • Lee, Su Yun;Kim, Hyang Yeon;Lee, Sarah;Lee, Jung Min;Muthaiya, Maria John;Kim, Beom Seok;Oh, Ji Young;Song, Chi Kwang;Jeon, Eun Jung;Ryu, Hyung Seok;Lee, Choong Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권11호
    • /
    • pp.1523-1531
    • /
    • 2012
  • The metabolite profile of meju during fermentation was analyzed using mass spectrometry techniques, including GC-MS and LC-MS, and the bacterial diversity was characterized. The relative proportions of bacterial strains indicated that lactic acid bacteria, such as Enterococcus faecium and Leuconostoc lactis, were the dominant species. In partial least-squares discriminate analysis (PLS-DA), the componential changes, which depended on fermentation, proceeded gradually in both the GC-MS and LC-MS data sets. During fermentation, lactic acid, amino acids, monosaccharides, sugar alcohols, and isoflavonoid aglycones (daidzein and genistein) increased, whereas citric acid, glucosides, and disaccharides decreased. MS-based metabolite profiling and bacterial diversity characterization of meju demonstrated the changes in metabolites according to the fermentation period and provided a better understanding of the correlation between metabolites and bacterial diversity.

Comparison of Cell Lysis Techniques via Q-TOF LC/MS

  • Kaplan, Ozan;Oncul, Selin;Ercan, Ayse;Celebier, Mustafa
    • Mass Spectrometry Letters
    • /
    • 제11권2호
    • /
    • pp.36-40
    • /
    • 2020
  • Untargeted metabolomics is a useful tool for drug development focusing on novel chemotherapeutic and chemopreventative agents against cancer cells. In recent years, quadrupole time of flight liquid chromatography-mass spectrometry (Q-TOF LC/MS)-based untargeted metabolomic approaches have gained importance to evaluate the effect of these agents at the molecular level. The researchers working on cell culture studies still do not apply standardized methodologies on sample preparation for untargeted metabolomics approaches. In this study, the rough and wet lysis techniques performed on MCF-7 breast cancer cells were compared with each other via the Q-TOF LC/MS-based metabolomic approach. The C18 and hydrophilic interaction liquid chromatography (HILIC) columns were used for the separation of the metabolites in MCF-7 cell lysates. 505 peaks were detected through the HILIC column and 551 peaks were found through the C18 column for the wet lysis technique. This situation supported by the base peak chromatograms showed that the wet lysis technique allowed us to extract higher number of non-polar metabolites. Almost equal number of metabolites was found for the C18 and HILIC columns (697 peaks for the HILIC column and 695 peaks for the C18 column) when the rough lysis technique was used. However, the intensities of polar metabolites were higher for the rough lysis technique on base peak chromatograms for both the HILIC and C18 columns. Although cell lysis technique, which is the first step in the sample preparation for cell culture studies, does not cause dramatic differences in the number of the detected metabolite peaks, it affects the polar and non-polar metabolite ratio significantly. Therefore, it must be considered carefully especially for in vitro drug development studies.

Determination of Flunixin and 5-Hydroxy Flunixin Residues in Livestock and Fishery Products Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)

  • Dahae Park;Yong Seok Choi;Ji-Young Kim;Jang-Duck Choi;Gui-Im Moon
    • 한국축산식품학회지
    • /
    • 제44권4호
    • /
    • pp.873-884
    • /
    • 2024
  • Flunixin is a veterinary nonsteroidal anti-inflammatory agent whose residues have been investigated in their original form within tissues such as muscle and liver. However, flunixin remains in milk as a metabolite, and 5-hydroxy flunixin has been used as the primary marker for its surveillance. This study aimed to develop a quantitative method for detecting flunixin and 5-hydroxy flunixin in milk and to strengthen the monitoring system by applying to other livestock and fishery products. Two different methods were compared, and the target compounds were extracted from milk using an organic solvent, purified with C18, concentrated, and reconstituted using a methanol-based solvent. Following filtering, the final sample was analyzed using liquid chromatography-tandem mass spectrometry. Method 1 is environmentally friendly due to the low use of reagents and is based on a multi-residue, multi-class analysis method approved by the Ministry of Food and Drug Safety. The accuracy and precision of both methods were 84.6%-115% and 0.7%-9.3%, respectively. Owing to the low matrix effect in milk and its convenience, Method 1 was evaluated for other matrices (beef, chicken, egg, flatfish, and shrimp) and its recovery and coefficient of variation are sufficient according to the Codex criteria (CAC/GL 71-2009). The limits of detection and quantification were 2-8 and 5-27 ㎍/kg for flunixin and 2-10 and 6-33 ㎍/kg for 5-hydroxy flunixin, respectively. This study can be used as a monitoring method for a positive list system that regulates veterinary drug residues for all livestock and fisheries products.

Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

  • Yim, Yong-Hyeon;Park, Ji-Youn;Han, Myung-Sub;Park, Mi-Kyung;Kim, Byung-Joo;Lim, Young-Ran;Hwang, Eui-Jin;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.440-446
    • /
    • 2005
  • A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

A Sensitive and Rapid LC-MS/MS Method for Determination of Berberine in Human Plasma

  • Kim, Jae Hee;Mai, Xuan-Lan;Kim, Kyu Yeon;Sim, Min-Seok;Lee, So-Yeon;Seo, Hee-Won;Lee, Gunhee;Kim, Dae-Jung;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제10권2호
    • /
    • pp.56-60
    • /
    • 2019
  • Coptidis Rhizoma (CR) has been used widely in traditional medicine to treat common diseases. This study aimed to develop a high-sensitivity liquid chromatography-tandem mass (LC-MS) spectrometry method for the evaluation of the pharmacokinetics of a new natural product that contain CR extract with the main bioactive compound, berberine, at trace concentrations. Human plasma samples were pretreated with methanol by a protein precipitation method. Berberine was analyzed on a Kinetex C18 column ($2.1mm{\times}50mm$, $100{\AA}$, $1.7{\mu}m$) using a mobile phase of 10 mM ammonium formate/0.1% formic acid in water (A) and acetonitrile (B) (50:50, v/v) with a flow rate of 0.25 mL/min. The analyte was detected by using electrospray ionization in positive mode with multiple reaction monitoring (MRM). The method was sensitive, with a lower limit of quantification of 1 pg/mL, which has not been previously obtained. The method was validated (over the range of 1-50 pg/mL) and applied successfully for the pharmacokinetic study of human plasma samples.