• 제목/요약/키워드: link level flow control

검색결과 20건 처리시간 0.015초

4-레벨 인버터의 DC-링크 전압 균형을 위한 향상된 전압 제어 기법 (An Improved Voltage Control Scheme for DC-Link Voltage Balancing in a Four-Level Inverter)

  • 김래영;이요한;최창호;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.544-554
    • /
    • 1999
  • Multi-level inverters are now receiving widespread interest form the industrial drives for high power variable speed applications. Especially, for the high power variable speed applications, a diode clamped multi-level inverter has been widely used. However, it has the inherent problem that the voltage of the link capacitors fluctuates. This paper describes a voltage control scheme effectively to suppress the DC-link potential fluctuation for a diode clamped four-level inverter. The current to flow from/into the each link capacitor is analyzed and the operation limit is obtained when a conventional SVPWM is used. To overcome the operation limit, a modified carrier-based SVPWM is proposed. Various simulation and experiment results are presented to verify the proposed voltage control scheme for DC-link voltage balancing.

  • PDF

ISDN을 위한 최적 데이타 링크 흐름 제어에 관한 연구 (A Study on The Optimal Data Link Window Flow Control for ISDN)

  • 김동연;신우철;박민용;이상배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1174-1177
    • /
    • 1987
  • The design of flow control protocols for integrared networks with complete voice traffic on the data link level is investigated. The class of admissible flow control policies analyzed maximized the average data link throughput subject to an average system time delay constraints a finite intervals (O,s). In particular, it is shown that the optimum control law is bang-bang (window flow mechanism). The window size L can be analytically derived from maximum tolerated time delay T, the input arrival C of the queueing system, the duration of the time interval S, the initial number of packets in the queue.

  • PDF

Neutral-Point-Clamped 인버터의 저 변조지수에서 DC 링크 전압 균형을 위한 간단한 컨트롤 기법 (A Simple Control Strategy for Balancing the DC-link Voltage of Neutral-Point-Clamped Inverters at low modulation index)

  • 마창수;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.560-564
    • /
    • 2003
  • This paper proposes a simple control strategy based on the discontinuous PWM(DPWM) to balance the DC-link voltage of three-level Neutral-Point-Clamped(WPC) inverters at low modulation index. New DPWM methods in multi-level inverter are also introduced. The proposed DPWM method changes the path and duration to flow the neutral point current out of or into neutral point of the DC-link and it makes the overall fluctuation of the DC-link voltage zero during a sampling time of reference voltage vector. Therefore, the voltage of the DC-link can be balanced fairly well and also the voltage ripple of the DC-link is reduced significantly. Moreover, comparing with conventional methods, the proposed strategy is very simple. The validity of the proposed DPWM method is verified by experiment

  • PDF

Performance Analysis of Random Early Dropping Effect at an Edge Router for TCP Fairness of DiffServ Assured Service

  • 허경
    • 한국통신학회논문지
    • /
    • 제31권4B호
    • /
    • pp.255-269
    • /
    • 2006
  • The differentiated services(DiffServ) architecture provides packet level service differentiation through the simple and predefined Per-Hop Behaviors(PHBs). The Assured Forwarding(AF) PHB proposed as the assured services uses the RED-in/out(RIO) approach to ensusre the expected capacity specified by the service profile. However, the AF PHB fails to give good QoS and fairness to the TCP flows. This is because OUT(out- of-profile) packet droppings at the RIO buffer are unfair and sporadic during only network congestion while the TCP's congestion control algorithm works with a different round trip time(RTT). In this paper, we propose an Adaptive Regulating Drop(ARD) marker, as a novel dropping strategy at the ingressive edge router, to improve TCP fairness in assured services without a decrease in the link utilization. To drop packets pertinently, the ARD marker adaptively changes a Temporary Permitted Rate(TPR) for aggregate TCP flows. To reduce the excessive use of greedy TCP flows by notifying droppings of their IN packets constantly to them without a decrease in the link utilization, according to the TPR, the ARD marker performs random early fair remarking and dropping of their excessive IN packets at the aggregate flow level. Thus, the throughput of a TCP flow no more depends on only the sporadic and unfair OUT packet droppings at the RIO buffer in the core router. Then, the ARD marker regulates the packet transmission rate of each TCP flow to the contract rate by increasing TCP fairness, without a decrease in the link utilization.

DiffServ 네트워크에서 공평성 향상을 위한 TRC Dropper의 성능 분석 (The Performance Analysis of TRC Dropper to improve fairness on DiffServ Networks)

  • 김훈기;홍성화
    • 한국시뮬레이션학회논문지
    • /
    • 제18권3호
    • /
    • pp.91-102
    • /
    • 2009
  • 평균 윈도우 크기는 평균 처리율과 많은 관계를 가지고 있다. 제안된 dropper는 fairness를 향상시키기 위해 윈도우 크기를 각 플로우의 레벨에 맞게 제어하도록 한다. 경쟁 패킷 드랍은 플로우가 많은 양의 대역폭을 차지하기 위해 동작한다. 경쟁 패킷 드랍 때문에 플로우는 전송 속도를 반으로 줄이게 되며, 이에 따라 코어 링크의 여유 용량이 존재하게 된다. 다른 플로우는 이 새로운 용량을 사용하게 되고, 따라서 다른 플로우는 좋은 처리율을 가지게 된다. 이런 방식으로 TCP의 전송속도를 제어하는 edge router의 새로운 기능 block인 TRC Dropper(Transmission Rate Control Dropper)를 제안한다. 제안한 TRC Dropper를 통하여 플로우들 간에 공평한 대역폭 분배를 실현하여 상대적으로 차별화된 서비스를 제공할 수 있다.

Novel Buck Mode Three-Level Direct AC Converter with a High Frequency Link

  • Li, Lei;Guan, Yue;Gong, Kunshan;Li, Guangqiang;Guo, Jian
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.407-417
    • /
    • 2018
  • A novel family of Buck mode three-level direct ac converters with a high frequency link is proposed. These converters can transfer an unsteady high ac voltage with distortion into a regulated sinusoidal voltage with a low THD at the same frequency. The circuit configuration is constituted of a three-level converter, high frequency transformer, cycloconverter, as well as input and output filters. The topological family includes forward, push-pull, half-bridge, and full-bridge modes. In order to achieve a reliable three-level ac-ac conversion, and to overcome the surge voltage and surge current of the cycloconverter, a phase-shifted control strategy is introduced in this paper. A prototype is presented with experimental results to demonstrate that the proposed converters have five advantages including high frequency electrical isolation, lower voltage stress of the power switches, bi-directional power flow, low THD of the output voltage, and a higher input power factor.

UPFC의 스위칭레벨 상세 모의 및 동적 특성 고찰 (Study of Dynamic Characteristics of an UPFC Switching-Level Model)

  • 원동준;김선호;한학근;이송근;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1287-1289
    • /
    • 1999
  • The UPFC(Unified Power Flow Controller) controls the magnitude and phase of the series injected voltage to exchange the real and reactive power with transmission line. The UPFC consists of two inverters connected together through the DC link capacitor. This paper describes the detailed UPFC switching-level model. PWM (Pulse Width Modulation) method is chosen to operate the inverters. Automatic voltage control mode and automatic power flow control mode is selected to control the UPFC. EMTP simulation is offered to obtain the basic operation characteristics of the UPFC and the dynamic characteristics of the UPFC is studied in detail.

  • PDF

A Fair Scalable Inter-Domain TCP Marker for Multiple Domain DiffServ Networks

  • Hur, Kyeong;Eom, Doo-Seop
    • Journal of Communications and Networks
    • /
    • 제10권3호
    • /
    • pp.338-350
    • /
    • 2008
  • The differentiated services (DiffServ) is proposed to provide packet level service differentiations in a scalable manner. To provide an end-to-end service differentiation to users having a connection over multiple domains, as well as a flow marker, an intermediate marker is necessary at the edge routers, and it should not be operated at a flow level due to a scalability problem. Due to this operation requirement, the intermediate marker has a fairness problem among the transmission control protocol (TCP) flows since TCP flows have intrinsically unfair throughputs due to the TCP's congestion control algorithm. Moreover, it is very difficult to resolve this problem without individual flow state information such as round trip time (RTT) and sending rate of each flow. In this paper, to resolve this TCP fairness problem of an intermediate marker, we propose a fair scalable marker (FSM) as an intermediate marker which works with a source flow three color marker (sf-TCM) operating as a host source marker. The proposed fair scalable marker improves the fairness among the TCP flows with different RTTs without per-flow management. Through the simulations, we show that the FSM can improve TCP fairness as well as link utilization in multiple domain DiffServ networks.

Transient stability improvement using quasi-multi pulse BTB-STATCOM

  • Vural, Ahmel M.;Bayindi, Kamil C.
    • Advances in Energy Research
    • /
    • 제2권1호
    • /
    • pp.47-59
    • /
    • 2014
  • Back-to-back STATCOM configuration is an extension of STATCOM in which the reactive power at two-sides and the real power flow through the DC link can be controlled concurrently and independently. This flexible operation brings many advantages to the micro-grids, distributed generation based systems, and deregulated power systems. In this paper, the dynamic control characteristics of the back-to-back STATCOM is investigated by simulating the detailed converter-level model of the converters in PSCAD. Various case studies in a single-machine test system are studied to present that the real power control feature of the BtB-STATCOM, even with a simple controller design, can enhance the transient stability of the machine under different fault scenarios.

Defending HTTP Web Servers against DDoS Attacks through Busy Period-based Attack Flow Detection

  • Nam, Seung Yeob;Djuraev, Sirojiddin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권7호
    • /
    • pp.2512-2531
    • /
    • 2014
  • We propose a new Distributed Denial of Service (DDoS) defense mechanism that protects http web servers from application-level DDoS attacks based on the two methodologies: whitelist-based admission control and busy period-based attack flow detection. The attack flow detection mechanism detects attach flows based on the symptom or stress at the server, since it is getting more difficult to identify bad flows only based on the incoming traffic patterns. The stress is measured by the time interval during which a given client makes the server busy, referred to as a client-induced server busy period (CSBP). We also need to protect the servers from a sudden surge of attack flows even before the malicious flows are identified by the attack flow detection mechanism. Thus, we use whitelist-based admission control mechanism additionally to control the load on the servers. We evaluate the performance of the proposed scheme via simulation and experiment. The simulation results show that our defense system can mitigate DDoS attacks effectively even under a large number of attack flows, on the order of thousands, and the experiment results show that our defense system deployed on a linux machine is sufficiently lightweight to handle packets arriving at a rate close to the link rate.