• Title/Summary/Keyword: linear plasma

Search Result 391, Processing Time 0.029 seconds

Development of Sensitive Analytical Method of Rhodanthpyrone A by a LC-MS/MS and its Application to Bioavailability Study in Rats

  • Kang, Bitna;Yoon, Jeong A;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.10 no.3
    • /
    • pp.88-92
    • /
    • 2019
  • A sensitive analytical method of rhodanthpyrone A in rat plasma was developed using a liquid chromatography-tandem mass spectrometry (LC-MS/MS). Rhodanthpyrone A and rhodanthpyrone B (internal standard) in rat plasma were extracted by a liquid-liquid extraction method with ethyl acetate. This extraction method gave results in high and reproducible extraction recovery in the range of 73.75-79.90% with no interfering peaks around the peak elution time of rhodanthpyrone A and B. The standard calibration curves for rhodanthpyrone A ranged from 0.5 to 2000 ng/mL were linear with $r^2$ > 0.994 and the inter- and intra-day accuracy and precision and the stability were within acceptance criteria. Using this validated analytical method, pharmacokinetics of rhodanthpyrone A following intravenous and oral administration of rhodanthpyrone A at doses of 2 mg/kg and 30 mg/kg, respectively, were investigated. Rhodanthpyrone A in rat plasma showed multi-exponential elimination pattern with high clearance and volume of distribution values. The absolute oral bioavailability of this compound was calculated as 3.7%. Collectively, the newly developed sensitive LC-MS/MS analytical method of rhodanthpyrone A could be successfully applied to investigate the pharmacokinetic properties of this compound and would be useful for the further studies on the efficacy, toxicity, and biopharmaceutics of rhodanthpyrone A.

Electromagnetic Electron-Cyclotron Wave for Ring Distribution with Alternating Current (AC) Electric Field in Saturn Magnetosphere

  • Haridas, Annex Edappattu;Kanwar, Shefali;Pandey, Rama Shankar
    • Journal of Astronomy and Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.35-42
    • /
    • 2022
  • During their respective missions, the spacecraft Voyager and Cassini measured several Saturn magnetosphere parameters at different radial distances. As a result of information gathered throughout the journey, Voyager 1 discovered hot and cold electron distribution components, number density, and energy in the 6-18 Rs range. Observations made by Voyager of intensity fluctuations in the 20-30 keV range show electrons are situated in the resonance spectrum's high energy tail. Plasma waves in the magnetosphere can be used to locate Saturn's inner magnetosphere's plasma clusters, which are controlled by Saturn's spin. Electromagnetic electron cyclotron (EMEC) wave ring distribution function has been investigated. Kinetic and linear approaches have been used to study electromagnetic cyclotron (EMEC) wave propagation. EMEC waves' stability can be assessed by analyzing the dispersion relation's effect on the ring distribution function. The primary goal of this study is to determine the impact of the magnetosphere parameters which is observed by Cassini. The magnetosphere of Saturn has also been observed. When the plasma parameters are increased as the distribution index, the growth/damping rate increases until the magnetic field model affects the magnetic field at equator, as can be seen in the graphs. We discuss the outputs of our model in the context of measurements made in situ by the Cassini spacecraft.

The Effect of Aluminum Element on the Surface Properties of CrAlN Coating Film Deposited via Arc Ion Plating ( Arc Ion Plating으로 증착된 CrAlN 코팅막의 표면 특성에 미치는 Al 원소의 영향 )

  • Jae-Un Kim;Byeong-Seok Lim;Young-Shin Yun;Byung-Woo Ahn;Han-Cheol Choe
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.1
    • /
    • pp.14-21
    • /
    • 2024
  • For this study, CrAlN multilayer coatings were deposited on SKD61 substrates using a multi-arc ion plating technique. The structural characteristics of the CrAlN multilayer coatings were evaluated using X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM). Additionally, the adhesion of the coatings was assessed through scratch testing, and the mechanical strength was evaluated using nanoindentation and tribometric tests for frictional properties. The results show that the CrAlN multilayer coatings possess a uniform and dense structure with excellent mechanical strength. Hardness measurements indicated that the CrAlN coatings have high hardness values, and both the coating adhesion and wear resistance were found to be improved compared to CrN. The addition of aluminum is anticipated to contribute to enhanced durability and wear resistance.

Influence of methionine supplementation of growing diets enriched with lysine on feedlot performance and characteristics of digestion in Holstein steer calves

  • Torrentera, Noemi;Carrasco, Ramses;Salinas-Chavira, Jaime;Plascencia, Alejandro;Zinn, Richard A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.1
    • /
    • pp.42-50
    • /
    • 2017
  • Objective: Two trials were conducted in order to examine the effects of level of supplemental methionine on productive performance, dietary energetic, plasma amino acid concentration, and digestive function. Methods: Dietary treatments consisted of a steam-flaked corn-based diet containing urea as the only source of supplemental nitrogen supplemented with no supplemental amino acid (control), or control plus 1.01% lysine and 0.032%, 0.064%, 0.096%, or 0.128% methionine. In Trial 1, 150 Holstein steer calves ($127{\pm}4.9kg$) were utilized to evaluate the influence of treatments on growth-performance, dietary energetic, plasma amino acid concentration during the first 112 days of growing period. During the initial 56-d period calves received the 5 experimental diets. During the subsequent 56-d period all calves were fed the control diet. Results: During the initial 56-d period, methionine supplementation increased (linear effect, p<0.01) plasma methionine. In the presence of supplemental lysine, increases on level of methionine in diet did not affect average daily gain. However, increased gain efficiency (quadratic effect, p = 0.03) and estimated dietary net energy (NE; linear effect, p = 0.05). Estimated metabolizable methionine supply was closely associated ($R^2=0.95$) with efficiency NE utilization for maintenance and gain. During the subsequent 56-d period, when all calves received the control diet (no amino acid supplementation), plasma amino acid concentrations and growth performance was not different among groups. However, the effects of methionine supplementation during the initial 56-period carried over, so that following a 56-d withdrawal of supplementation, the overall 112-d effects on gain efficiency (quadratic effect, p = 0.05) dietary NE (linear effect, $p{\leq}0.05$) remained appreciable. In Trial 2, 5 cannulated Holstein steers were used to evaluate treatment effects on characteristics of digestion and amino acid supply to the small intestine. There were no treatment effects on flow of dietary and microbial N to the small intestine. Postruminal N digestion increased (p = 0.04) with increasing level of supplemental methionine. Methionine supplementation linearly increased (p<0.01) duodenal flow of methionine. Likewise, lysine supplementation increased an average of 4.6% (p = 0.04) duodenal flow of lysine. In steers that received non-supplemented diet, observed intestinal amino acid supply were in good agreement with expected. Conclusion: We conclude that addition of rumen-protected methionine and lysine to diets may enhance gain efficiency and dietary energetics of growing Holstein calves. Observed amino acid supply to the small intestine were in good agreement with expected, supportive of NRC (2000, Level 1).

The analysis of impurities in rare earth oxide for fluorescent substance by ICP-MS (ICP-MS에 의한 형광체용 $(Y,\;Eu)_2O_3$ 중 불순물 분석 연구)

  • Kim, Sang-Kyoung;Jang, Seung-Kyu
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • A survey was made on detection limit, reproducibility, matrix effect, linear dynamic range and the memory effect of yttrium and europium in order to analyze rare earth elements which exist as impurities in the rare earth oxide which is raw materials of fluorescent substance. When analysing a certain amount of thulium quantitatively using inductively coupled plasma mass spectrometry, it was found that the analysis was interfered with $EuO^+$ which is one of polyatomic ions caused by plasma. As the intensity of thulium linearly proportional to the europium concentration, it was possible to the determine the actual concentration of thulium.

  • PDF

Application of Inactivation Model on Phytophthora Blight Pathogen (Phytophthora capsici) using Plasma Process (플라즈마 공정을 이용한 고추역병균(Phytophthora capsici) 불활성화 모델의 적용)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1393-1404
    • /
    • 2015
  • Ten empirical disinfection models for the plasma process were used to find an optimum model. The variation of model parameters in each model according to the operating conditions (first voltage, second voltage, air flow rate, pH, incubation water concentration) were investigated in order to explain the disinfection model. In this experiment, the DBD (dielectric barrier discharge) plasma reactor was used to inactivate Phytophthora capsici which cause wilt in tomato plantation. Optimum disinfection models were chosen among ten models by the application of statistical SSE (sum of squared error), RMSE (root mean sum of squared error), $r^2$ values on the experimental data using the GInaFiT software in Microsoft Excel. The optimum models were shown as Log-linear+Tail model, Double Weibull model and Biphasic model. Three models were applied to the experimental data according to the variation of the operating conditions. In Log-linear+Tail model, $Log_{10}(N_o)$, $Log_{10}(N_{res})$ and $k_{max}$ values were examined. In Double Weibull model, $Log_{10}(N_o)$, $Log_{10}(N_{res})$, ${\alpha}$, ${\delta}_1$, ${\delta}_2$, p values were calculated and examined. In Biphasic model, $Log_{10}(N_o)$, f, $k_{max1}$ and $k_{max2}$ values were used. The appropriate model parameters for the calculation of optimum operating conditions were $k_{max}$, ${\alpha}$, $k_{max1}$ at each model, respectively.

Fluctuation in Plasma Nanofabrication

  • Shiratani, Masaharu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.96-96
    • /
    • 2016
  • Nanotechnology mostly employs nano-materials and nano-structures with distinctive properties based on their size, structure, and composition. It is quite difficult to produce nano-materials and nano-structures with identical sizes, structures, and compositions in large quantities, because of spatiotemporal fluctuation of production processes. In other words, fluctuation is the bottleneck in nanotechnology. We propose three strategies to suppress such fluctuations: employing 1) difference between linear and nonlinear phenomena, 2) difference in time constants, and 3) nucleation as a bottleneck phenomenon. We are also developing nano- and micro-scale guided assembly using plasmas as a plasma nanofabrication.1-5) We manipulate nano- and micro-objects using electrostatic, electromagnetic, ion drag, neutral drag, and optical forces. The accuracy of positioning the objects depends on fluctuation of position and energy of an object in plasmas. Here we evaluate such fluctuations and discuss the mechanism behind them. We conducted in-situ evaluation of local plasma potential fluctuation using tracking analysis of fine particles (=objects) in plasmas. Experiments were carried out with a radio frequency low-pressure plasma reactor, where we set two quartz windows at the top and bottom of the reactor. Ar plasmas were generated at 200 Pa by applying 13.56MHz, 450V peak-to-peak voltage. The injected fine particles were monodisperse methyl methacrylate-polymer spheres of $10{\mu}m$ in diameter. Fine particles were injected into the reactor and were suspended around the plasma/sheath boundary near the powered electrode. We observed binary collision of fine particles with a high-speed camera. The frame rate was 1000-10000 fps. Time evolution of their distance from the center of mass was measured by tracking analysis of the two particles. Kinetic energy during the collision was obtained from the result. Potential energy formed between the two particles was deduced by assuming the potential energy plus the kinetic energy is constant. The interaction potential is fluctuated during the collision. Maximum amplitude of the fluctuation is 25eV, and the average is 8eV. The fluctuation can be caused by neutral molecule collisions, ion collisions, and fluctuation of electrostatic force. Among theses possible causes, fluctuation of electrostatic force may be main one, because the fine particle has a large negative charge of -17000e and the corresponding electrostatic force is large compared to other forces.

  • PDF

Validation of a Selective Method for Simultaneous Determination of Doxifluridine and 5-Fluorouracil in Dog Plasma by LC-MS/MS (LC/MS/MS를 이용한 비글견의 혈장 중 Doxifluridine 및 5-Fluorouracil의 동시 분석법 Validation)

  • Kim, Ghee-Hwan;Kim, Won;Kim, Jin-Sung;Jin, Qingri;Kang, Won-Ku;Lee, Jong-Hwa;Ha, Jung-Heun;Jeong, Eun-Ju
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.179-186
    • /
    • 2007
  • A simple, sensitive and selective liquid chromatographic/tandem mass spectrometric method (LC-MS/MS) was developed and validated for doxifluridine and 5-fluorouracil (5-FU) quantification in dog heparinized plasma. Sample preparation was based on liquid-liquid extraction using a mixture of isopropanol/ethyl acetate (1/9 v/v) to extract doxifluridine, 5-FU and 5-chlorouracil (5-CU, an internal standard) from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 2.7, 1.5 and 1.7 min for doxifluridine, 5-FU and 5-CU, respectively with shorter analysis time within 5 min than previously reported methods. The ionization was optimized using ESI negative mode and selectivity was achieved by tandem mass spectrometric analysis by multiple reaction monitoring (MRM) using the transformations of m/z 244.8>107.6, 129.0>42.0 and 144.9>42.1 for doxifluridine, 5-FU and 5-CU, respectively. The achieved low limit of quantification was 20.0 ng/mL and the assay exhibited linear range of 20-2000 ng/mL ($R^2>0.99957$ for doxifluridine and $R^2>0.99857$ for 5-FU), using $100{\mu}L$ of plasma. Accuracy and precision of quality control samples for both doxifluridine and 5-FU met KFDA and FDA Guidance criteria of 15% for accuracy with coefficients of variation less than 15%. This method demonstrated adequate sensitivity, specificity, accuracy, precision and stability to support the simultaneous analysis of doxifluridine and 5-FU in dog plasma samples in pharmacokinetic and bioequivalence studies.

Bioequivalence Evaluation of Two brands of Cetirizine HCl 10 mg Tablets (Zyrix and Zyrtec) in Healthy Male Volunteers

  • Im, Ho-Taek;Won, Jong-Hoen;Cho, Sung-Hee;Lee, Heon-Woo;Park, Wan-Su;Rew, Jae-Hwan;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.355-360
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two cetirizine HCl tablets, Zyrtec tablet (UCB Pharm. Co., Ltd. Korea, reference product) and Zyrix tablet (Kukje Pharm. Co., Ltd., Korea, test product), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (diazepam), plasma samples were extracted using 1 mL of dichloromethane. Compounds extracted were analyzed by reverse-phase HPLC with ultra-violet detector. This method for determination cetirizine is proved accurate and reproducible with a limit of quantitation of 10 ng/mL in male plasma. Twenty-four healthy male Korean volunteers received each medicine at the cetirizine HCl dose of 10 mg in a $2{\times}2$ crossover study. There was a one-week wash out period between the doses. Plasma concentrations of cetirizine were monitored for over a period of 24 hr after the administration. AUC (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed AUC and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals for the log transformed data were acceptable range of log 0.8 to log 1.25 $(e.g.,\;log\;0.93-log\;1.08\;for\;AUC_{0-t},\;log\;0.91-log\;1.08\;for\;AUC_{0-{\infty}}\;and\;log\;1.01-log\;1.11\;for\;C_{max})$. The major parameters, AUC and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that Zyrix tablet is bioequivalent to Zyrtec tablet.

Effect of Atrial Natriuretic Peptide on the Renal Function in Two-Kidney One-Clip Hypertensive Rats (신성 고혈압 백서에서 Atrial Natriuretic Peptide의 신장기능에 미치는 효과)

  • Cho, Kyung-Woo;Kim, Suhn-Hee;So, June-No;Ryu, Hoon;Seul, Kyung-Hwan
    • The Korean Journal of Physiology
    • /
    • v.23 no.1
    • /
    • pp.67-78
    • /
    • 1989
  • Since the atrial receptor was suggested to be involved in the control of extracellular fluid volume, it has been shown that the granularity of atrial cardiocytes can be changed by water and salt depletion, and that an extract of atrial tissue, when injected intravenously into anesthetized rats, causes a large and rapid increase in renal excretions of sodium and water. The immunoreactive atrial natriuretic peptide (ANP) has been found in the plasma of patients suffering from various cardiovascular diseases. A high level of ANP in the plasma has been reported in essential hypertension. Several studies on the effects of ANP on renal function and arterial blood pressure have presented contradictory results showing attenuated or accentuated responses. Thus, involvement of the ANP in the development of hypertension remains unresolved. Present study was undertaken to investigate whether the ANP is involved in the development of hypertension in two-kidney one-clip Goldblatt hypertensive rats. The plasma concentration of immunoreactive ANP appeared to be significantly elevated in hypertensive rats as compared with normotensive Goldblatt operated and sham-operated rats. Plasma renin concentration was higher in hypertensive rats than in normotensive rats, as observed in earlier experiments. Intravenous infusions of ANP resulted in increases of urine flow and urinary excretions of sodium and potassium in both hypertensive and normotensive rats. The renal response to ANP was markedly accentuated in Goldblatt hypertensive rats. The plasma concentration of ANP showed a linear relationship with the arterial blood pressure. Infusions of ANP reduced blood pressure both in hypertensive and normotensive rats. These results suggest that in Goldblatt hypertensive rats an elevation of ANP level in the plasma may not be a cause, but instead a consequence of hypertension, and that the renal responsiveness to the ANP is accentuated by some unknown mechanisms.

  • PDF