• 제목/요약/키워드: linear compressive behavior

검색결과 87건 처리시간 0.02초

Micro-mechanical modeling for compressive behavior of concrete material

  • Haleerattanawattana, P.;Senjuntichai, T.;Limsuwan, E.
    • Structural Engineering and Mechanics
    • /
    • 제18권5호
    • /
    • pp.691-707
    • /
    • 2004
  • This paper presents the micro-mechanical modeling for predicting concrete behavior under compressive loading. The model is able to represent the heterogeneities in the microstructure up to three phases, i.e., aggregate particles, matrix and interfaces. The smeared crack concept based on non-linear fracture mechanics is implemented in order to formulate the constitutive relation for each component. The splitting tensile strength is considered as a fracture criterion for cracking in micro-level. The finite element method is employed to simulate the model based on plane stress condition by using quadratic triangular elements. The validation of the model is verified by comparing with the experimental results. The influence of tensile strength from both aggregate and matrix phases on the concrete compressive strength is demonstrated. In addition, a guideline on selecting appropriate tensile strength for each phase to obtain specified concrete compressive strength is also presented.

폴리우레탄 폼 비선형 압축 거동 해석용 온도 의존 손상 점소성 구성방정식 (Temperature-Dependent Viscoplastic-Damage Constitutive Model for Nonlinear Compressive Behavior of Polyurethane Foam)

  • 이정호;김슬기;이제명
    • 한국전산구조공학회논문집
    • /
    • 제29권5호
    • /
    • pp.437-445
    • /
    • 2016
  • 현재 많은 산업에서 구조물의 온도환경 유지를 위한 단열재로 폴리우레탄 폼이 사용되며, 수명 동안 정적 및 동적의 다양한 하중이 이에 부과된다. 폴리우레탄 폼은 고분자재료로써 다공성이며, 단열성능은 내부기공의 크기에 크게 의존한다. 또한, 폴리우레탄 폼의 기계적 거동은 변형률 속도 및 온도에 대한 의존성이 큰 동시에 압축에 대하여 큰 비선형 연성거동을 보인다. 이러한 비선형 연성 압축거동 중에 폴리우레탄 폼은 변형률의 증가에 따라 기공율과 탄성계수의 감소를 보인다. 따라서 본 연구에서는 상기 특성들을 포함한 폴리우레탄 폼의 변형률 속도 및 온도 의존 비선형 압축거동을 모사하기 위하여 온도 의존 손상 점소성 구성방정식이 개발되었다.

고압하에서의 적층복합재의 기계적 거동에 대한 실험적 고찰 (Experimental Investigation on the Mechanial Behavior of Graphite/Epoxy Composites Under Hydrostatic Pressure)

  • 이경업;배국동
    • 대한기계학회논문집A
    • /
    • 제20권8호
    • /
    • pp.2431-2435
    • /
    • 1996
  • In order to determine the effects of hydrostatic pressure on the mechanical behavior of graphite fiber reinforced composites, the modulus, fracture stress(maximum stress), and fracture strain of graphite/epoxy composites have been determined as a function of pressure. Composite specimens used in this study were 90-deg unidirectional and had a 60% fiber volume fraction. Compressive tests under five different pressure levels were conducted. The result showed the modulus measured from as initial slope of stress-strain curve increased bilinearly with pressure with a break at 200 MPa. It was also found that fracture stress and fracture strain increased in a linear fashion with pressure.

UHPCC의 압축응력-변형률 관계에 대한 강섬유 혼입률의 영향 (The Effect of Steel-Fiber Contents on the Compressive Stress-Strain Relation of Ultra High Performance Cementitious Composites (UHPCC))

  • 강수태;류금성
    • 콘크리트학회논문집
    • /
    • 제23권1호
    • /
    • pp.67-75
    • /
    • 2011
  • 이 연구에서는 UHPCC에서 강섬유 혼입률이 압축거동에 미치는 영향에 관한 연구를 수행하였으며, 그 결과로부터 UHPCC에 적용가능한 압축거동 모델을 제시하고자 하였다. 섬유혼입률 0~5 vol.%에 대해 실험을 수행한 결과, 섬유혼입률이 증가함에 따라 압축강도 및 그 때의 극한변형률 및 탄성계수가 증가하는 경향을 확인할 수 있었다. 이와 같은 결과는 100 MPa 이하의 강섬유보강 콘크리트에 대한 기존 연구 결과들과 비교했을 때, 압축강도는 섬유보강효과가 거의 동일한 경향을 나타내는 반면, 극한변형률과 탄성계수에 대한 섬유보강효과는 상대적으로 훨씬 적게 나타났다. 섬유혼입률이 증가함에 따른 UHPCC의 압축강도, 극한변형률 및 탄성계수의 변화를 섬유보강지수(RI)를 이용한 선형관계식으로 표현하였다. UHPCC의 압축거동에 대한 섬유보강효과는 거동의 형상에 전혀 영향을 미치지 않으며, 다만 압축강도와 그 때의 극한변형률 및 탄성계수에 영향을 미치는 점을 고려하여 UHPCC의 압축응력-변형률 관계를 제시하였다.

Effect of Strain Path on Lattice Strain Evolution during Monotonic and Cyclic Tension of Magnesium Alloy

  • Yoon, Cheol;Gharghouri, Michael A.;Lee, Soo Yeol
    • 한국재료학회지
    • /
    • 제25권5호
    • /
    • pp.221-225
    • /
    • 2015
  • In-situ neutron diffraction has been employed to examine the effect of strain path on lattice strain evolution during monotonic and cyclic tension in an extruded Mg-8.5wt.%Al alloy. In the cyclic tension test, the maximum applied stress increased with cycle number. Lattice strain data were acquired for three grain orientations, characterized by the plane normal to the stress axis. The lattice strain in the hard {10.0} orientation, which is unfavorably oriented for both basal slip and {10.2} extension twinning, evolved linearly throughout both tests during loading and unloading. The {00.2} orientation exhibited significant relaxation associated with {10.2} extension twinning. Coupled with a linear lattice strain unloading behavior, this relaxation led to increasingly compressive residual strains in the {00.2} orientation with increasing cycle number. The {10.1} orientation is favorably oriented for basal slip, and thus showed a soft grain behavior. Microyielding occurred in the monotonic tension test and in all cycles of the cyclic test at an applied stress of ~50 MPa, indicating that strain hardening in this orientation was not completely stable from one cycle to the next. The lattice strain unloading behavior was linear in the {10.1} orientation, leading to a compressive residual strain after every cycle, which, however, did not increase systematically from one cycle to the next as in the {00.2} orientation.

Experimental and numerical research on the behavior of steel-fiber-reinforced-concrete columns with GFRP rebars under axial loading

  • Iman Saffarian;Gholam Reza Atefatdoost;Seyed Abbas Hosseini;Leila Shahryari
    • Structural Engineering and Mechanics
    • /
    • 제86권3호
    • /
    • pp.399-415
    • /
    • 2023
  • This paper presents the experimental and numerical evaluations on the circular SFRC columns reinforced GFRP rebars under the axial compressive loading. The test programs were designed to inquire and compare the effects of different parameters on the columns' structural behavior by performing experiments and finite element modeling. The research variables were conventional concrete (CC), fiber concrete (FC), types of longitudinal steel/GFRP rebars, and different configurations of lateral rebars. A total of 16 specimens were manufactured and categorized into four groups based on different rebar-concrete arrangements including GRCC, GRFC, SRCC, and SRFC. Adding steel fibers (SFs) into the concrete, it was essential to modify the concrete damage plastic (CDP) model for FC columns presented in the finite element method (FEM) using ABAQUS 6.14 software. Failure modes of the columns were similar and results of peak loads and corresponding deflections of compression columns showed a suitable agreement in tests and numerical analysis. The behavior of GFRP-RC and steel-RC columns was relatively linear in the pre-peak branch, up to 80-85% of their ultimate axial compressive loads. The axial compressive loads of GRCC and GRFC columns were averagely 80.5% and 83.6% of axial compressive loads of SRCC and SRFC columns. Also, DIs of GRCC and GRFC columns were 7.4% and 12.9% higher than those of SRCC and SRFC columns. Partially, using SFs compensated up to 3.1%, the reduction of the compressive strength of the GFRP-RC columns as compared with the steel-RC columns. The effective parameters on increasing the DIs of columns were higher volumetric ratios (up to 12%), using SFs into concrete (up to 6.6%), and spiral (up to 5.5%). The results depicted that GFRP-RC columns had higher DIs and lower peak loads compared with steel-RC columns.

고강도 철근 콘크리트 보의 휨 설계 및 연성능력 (Flexural Design and Ductile Capacity of Reinforced High Strength Concrete Beams)

  • 신성우;유석형;안종문;이광수
    • 콘크리트학회지
    • /
    • 제8권6호
    • /
    • pp.141-149
    • /
    • 1996
  • 동일한 인장철근배근상태($\rho$/$\rho_b$=constant)에서 휨을 받는 고강도 철근 콘크리트 보는 보통강도의 철근 콘크리트보에 비해 더욱 취성적인 거동을 하게 된다. 본 실험결과 연성적인 파괴를 유도하기 위하여 콘크리트의 강도가 830kg/$cm^2$이상일 경우 철근비를 $0.6\rho_b$이하로 배근하여야 할 것으로 나타났다. 또한 콘크리트 강도가 830kg/$cm^2$ 이상일 경우 사각형응력 블록을 사용한 ACI 휨강도식의 안전율이 감소하였으며, 삼각형에 가까운 압축응력 분포를 나타내었다. 이는 콘크리트 강도가 증가할수록 응력-변형률 곡선이 거의 선형적으로 증가하는 재료적 성질에 기인하는 것으로 사료된다.

Artificial neural network model using ultrasonic test results to predict compressive stress in concrete

  • Ongpeng, Jason;Soberano, Marcus;Oreta, Andres;Hirose, Sohichi
    • Computers and Concrete
    • /
    • 제19권1호
    • /
    • pp.59-68
    • /
    • 2017
  • This study focused on modeling the behavior of the compressive stress using the average strain and ultrasonic test results in concrete. Feed-forward backpropagation artificial neural network (ANN) models were used to compare four types of concrete mixtures with varying water cement ratio (WC), ordinary concrete (ORC) and concrete with short steel fiber-reinforcement (FRC). Sixteen (16) $150mm{\times}150mm{\times}150mm$ concrete cubes were used; each contained eighteen (18) data sets. Ultrasonic test with pitch-catch configuration was conducted at each loading state to record linear and nonlinear test response with multiple step loads. Statistical Spearman's rank correlation was used to reduce the input parameters. Different types of concrete produced similar top five input parameters that had high correlation to compressive stress: average strain (${\varepsilon}$), fundamental harmonic amplitude (A1), $2^{nd}$ harmonic amplitude (A2), $3^{rd}$ harmonic amplitude (A3), and peak to peak amplitude (PPA). Twenty-eight ANN models were trained, validated and tested. A model was chosen for each WC with the highest Pearson correlation coefficient (R) in testing, and the soundness of the behavior for the input parameters in relation to the compressive stress. The ANN model showed increasing WC produced delayed response to stress at initial stages, abruptly responding after 40%. This was due to the presence of more voids for high water cement ratio that activated Contact Acoustic Nonlinearity (CAN) at the latter stage of the loading path. FRC showed slow response to stress than ORC, indicating the resistance of short steel fiber that delayed stress increase against the loading path.

Seismic response and retrofitting proposals of the St. Titus Chruch, Heraklion, Crete, Greece

  • Tzanakis, Michael J.;Papagiannopoulos, George A.;Hatzigeorgiou, George D.
    • Earthquakes and Structures
    • /
    • 제10권6호
    • /
    • pp.1347-1367
    • /
    • 2016
  • The purpose of this work is to investigate the seismic behavior of St. Titus Church in Heraklion, Crete, Greece as well as the need of its seismic retrofitting. A numerical model of the Church is constructed using shell finite elements and it is then seismically examined using response spectrum and linear time-history analyses. Effects of soil-structure interaction have been also taken into account. The Church without retrofit is expected to exhibit extensive tensile failures and many compressive ones. Aiming to maintain the architectural character of the structure as well as to increase its seismic resistance, a retrofitting procedure involving injection of cement grout in conjunction with reinforced concrete jacketing to the internal side of the masonry walls is proposed. A numerical implementation of the proposed seismic retrofitting is performed and its effect is evaluated by response spectrum and linear time-history analyses. From the results of these analyses, it is shown that compressive failures are eliminated while only few tensile failures of local character take place.

Effect of environmentally friendly materials on steel corrosion resistance of sustainable UHPC in marine environment

  • Tahwia, Ahmed M.;Elgendy, Gamal M.;Amin, Mohamed
    • Structural Engineering and Mechanics
    • /
    • 제82권2호
    • /
    • pp.133-149
    • /
    • 2022
  • This study investigates the resistance of sustainable ultra-high performance concrete (UHPC) on steel reinforcement corrosion. For enhancing the sustainability of UHPC, concrete mixes were prepared with ordinary Portland cement main binder, and mixes with moderate to high percentages of blast furnace cement (CEM III), fly ash (FA), and slag cement as partial replacements of the full quantity of the used cement. Linear polarization resistance technique was employed to estimate the electrochemical behavior of the concrete specimens. Results showed that the compressive strength and the resistance of steel to corrosion in marine environments can be enhanced by improving the sustainability of UHPC through incorporation of CEM III, FA, and slag cement. FA replacement of up to 50% with the addition of 15% SF content produced better compressive strength and steel corrosion resistance than slag cement whether with the use of ordinary Portland cement or blast furnace cement as the main binder.