• 제목/요약/키워드: line to line short

검색결과 1,145건 처리시간 0.036초

단거리 지대공 유도무기에서의 시선지령식 유도법칙과 비례항법 유도법칙의 성능비교 (Performance Comparisons between Command to Line-of-Sight Guidance Law and Proportional Navigation Guidance Law in Short Range Surface-to-Air Missile)

  • 이연석;유악환;김양우
    • 제어로봇시스템학회논문지
    • /
    • 제13권3호
    • /
    • pp.273-278
    • /
    • 2007
  • In this paper, a performance comparison between CLOS(Command to Line-of-Sight) guidance law and PN(Proportional Navigation) guidance law is made, based on a short range surface-to-air missile simulation program called KNUCLOS. This simulation program has a full nonlinear aerodynamic missile model, a tracker model for missile and target, and target model. According to the simulation results, the PN guidance law has a better performance than CLOS guidance law under various target speed.

1회선 송전선로 단락사고의 개선된 고장점 표정기법 (Enhanced Fault Location Algorithm for Short Faults of Transmission Line)

  • 이경민;박철원
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.955-961
    • /
    • 2016
  • Fault location estimation is an important element for rapid recovery of power system when fault occur in transmission line. In order to calculate line impedance, most of fault location algorithm uses by measuring relaying waveform using DFT. So if there is a calculation error due to the influence of phasor by DC offset component, due to large vibration by line impedance computation, abnormal and non-operation of fault locator can be issue. It is very important to implement the robust fault location algorithm that is not affected by DC offset component. This paper describes an enhanced fault location algorithm based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any erstwhile information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced fault location algorithm uses DFT filter as well as the proposed DC offset filter. The behavior of the proposed fault location algorithm using off-line simulation has been verified by data about several fault conditions generated by the ATP simulation program.

전차선로의 회로정수 측정방안 연구 (Measurement Method for Catenary Line Constant)

  • 오광해;이한민;이장무;이기원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.620-627
    • /
    • 2000
  • This paper presents a mettled to obtain line constants for a catenary system. To find them, voltages, currents and power factors according to frequencies were measured in short circuit and open circuit respectively. And front the measured data, resistances, inductances and capacitances were also calculated.

  • PDF

Python 기반 WSCR 강건 지수를 이용한 미래계통 구축에 관한 연구 (A Study on Future System Construction Using WSCR Strengthness Index based on Python)

  • 박성준;허진;김현진;조윤성
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.994-1001
    • /
    • 2018
  • In this paper, to studied about future power system construction using PSS / E-Python API. Python-based future system automatical construction methods and modeling of renewable sources. it confirmed the stability of the powert system for each renewable area by calculating the weighted short circuit ratio (WSCR) index. it calculated the short circuit ratio (SCR) and selected the transmission line linkage scenario to improve the stability of vulnerable areas. it confirmed the WSCR index improvement through the selected transmission line linkage of scenario, and analyzed the stability of the renewable power system applying the scenario. It describes Facts and Shunt devices adjustment for the load flow convergence. It describes the stable methed of the bus voltage through the transformer Ratio Tap adjustment. By performing PSS/E ASCC using the Python it was performed three-phase short circuit fault capacity analysis, it is confirmed whether excess of the fault current circuit breaker capacity. In order to contingency accident analysis, it have described the generation of one or two line list of each areas using the Python. The list is used to contingency analysis and describe the soluted of the transmission line overload through comparison before and after adding the scenario line.

동기 발전기의 평형 및 불평형 고장해석 (Balanced and Unbalanced Fault Analysis of Synchronous Generator)

  • 박철원;안준영;이종수;이상성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.402-404
    • /
    • 2006
  • In this paper, we simulated transient-state under fault in stator windings of synchronous generator. The fault types are line to ground fault, line to line short fault, and three phase short fault. For fault analysis of generator system, the voltage equation of a synchronous machine using the two-axis theory was used. It can be used to analyze important features of faults and to develop enhanced protection methods.

  • PDF

Development of a 170kV 50kA Capacitorless Gas Circuit Breaker

  • Park, K. Y.;K. D. Song;Y. H. Oh;W. P. Song;J. H. Kang;Park, S. W.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.73-76
    • /
    • 2003
  • In modern EHV (Extra High Voltage) class GCBs (Gas Circuit Breakers), the interruption capability for SLF (Short Line Fault) is one of the most important aspects of performance required for GCBs. Up to now, the SLF interruption capability of EHV class GCBs was partially assisted by the adoption of capacitors able to decrease the dV/dt of the TRV (Transient Recovery Voltage), particularly the TRV on the line side. This paper describes the technique to increase the SLF interruption capability of EHV class GCBs as well as the procedure to develop capacitorless l70kV 50kA GCB.

400Kb/s급 디지털 가입자 전송 시스템에 적합한 적응형 선로 등화기의 구현 (Implementation of the Adaptive Line Equalizer for a Digital Subscriber Loop Transmission System Operating at 400Kb/s)

  • 염흥열;김재근;조규섭
    • 대한전자공학회논문지
    • /
    • 제24권3호
    • /
    • pp.387-393
    • /
    • 1987
  • The introduction of a digiral subscriber loop transmission system necessitates an optimized line interface solution. To meet this objective an adaptive line equalizer has been developed. The equalizer can be compensated up to 42 dB line loss at 200KHz, and operated up to 3.2 Km transmission length (0.4 mm\ulcornercable)at a rate of 400Kb/s. This has been builted using a variable \ulcorner equalizer to compensate a frequency-attenuation characteristics of metallic cable, an AGC (automatic gain control) circuits with simple control algorithm, and various filters to minimize a transmission constraints over subscriber loop. The purpose of this paper is to present a short description of a design of the adaptive line equalizer with a summary of implementation results. Some design concepts and considerations which results in an implementation of the equalizer are also given.

  • PDF

대규모 계통의 디지털 시뮬레이션을 위한 계통분할 기법이 관한 연구 (A Study on Power System Decomposition Technique for Digital Simulation of Large Power System)

  • 이철균;이진;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.171-173
    • /
    • 2002
  • This paper presents a power system decomposition technique for digital simulation of large power system. To decompose power system, distributed transmission line model is used. But this model can be used only for long transmission lines. In this paper, capacitor compensation method is proposed to use distributed transmission line model for short transmission line. And case study shows proposed method can be used for effective power system decompositon in digital simulation of large power system.

  • PDF

Breeding of Korean Ginseng (Panax ginseng C. A. Meyer)

  • Kwang-Tae Choi;Woo
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 1998년도 Advances in Ginseng Research - Proceedings of the 7th International Symposium on Ginseng -
    • /
    • pp.96-102
    • /
    • 1998
  • A lot of individual ginseng plants were selected in the farmer's fields to develop new ginseng varieties with desirable traits. Among them, a promising line has been developed through comparative cultivation of several lines selected with pure line separation of local raced. It was then designated as "KC (denotes Korean Ginseng)" and tested in the regional yield and adaptation trials for 10 years. KG lines grew vigorously after 4 years of age. Especially, KG 102 line arson운 them showed traits of multiple and short stems. As for the root characters, the length of taproot of KG 101 line was longer than that of local race, Jakyung-jong, or other lines ailed the root weight of KG 102 line waIn 15 % higher than that of local race. In general, KG 101, KG 103, KG 104, and Hwangsauk-jong had good root shape. Total amount of ginsenosides of ginseng taproot was the highest in KG 103 line than in local race and other lines. In these studies, we, elected three superior lines, KG 101, KG 102, and KG 103, having characteristic of good root shape, high yield, and large amount of ginsenoside, respectively.

  • PDF

Double Negative, Positive 전승 선로를 이용한 대칭적적인 주파수 스캐닝 누설파 안테나 (Symmetrical Scanning Leaky Wave Antenaa Using Double Negative and Double Positive Transmission Line)

  • 이재곤;이정해
    • 한국전자파학회논문지
    • /
    • 제15권11호
    • /
    • pp.1069-1074
    • /
    • 2004
  • 본 논문에서는 직렬 inter-digital 커패시터와 이중 병렬 인덕티브 쇼트 스텁으로 구성된 double negative(DNG) 전송 선로를 설계하였다. 이러한 DNG 전송 선로는 특정한 주파수 이상에서는 double positive(DPS) 전송 선로의 특성을 가진다. 다시 말해서, 설계된 전송 선로는 DNG와DPS전송 선로의 특성을 주파수에 따라서 동시에 가진다. 누설파 대역에서의 DPS/DNG 전송 선로는 주파수 스캐닝 안테나로 이용되어 질 수 있다. 대칭 누설파 안테나의 분산 특성과 원거리 방사 패턴을 모의실험하였고 제작 및 측정하였다. 모의실험 결과는 측정결과와 대략 일치하였다.