• Title/Summary/Keyword: line sensitivity

Search Result 689, Processing Time 0.034 seconds

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Isolation of SYP61/OSMl that is Required for Salt Tolerance in Arabidopsis by T-DNA Tagging (애기장대에서 고염 스트레스 내성에 관여하는 OSM1/SYP61 유전자의 동정)

  • Kim, Ji-Yeon;Baek, Dong-Won;Lee, Hyo-Jung;Shin, Dong-Jin;Lee, Ji-Young;Choi, Won-Kyun;Kim, Dong-Giun;Chung, Woo-Sik;Kwak, Sang-Soo;Yun, Dae-Jin
    • Journal of Plant Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.11-18
    • /
    • 2006
  • Salt stress is one of major environmental factors influencing plant growth and development. To identify salt tolerance determinants in higher plants, a large-scale screen was conducted with a bialaphos marker-based T-DNA insertional collection of Arabidopsis ecotype C24 mutants. One line for salt stress-sensitive mutant (referred to as ssm1) exhibited increased sensitivity to both ionic (NaCl) and nonionic (mannitol) osmotic stress in a root growth assay. This result suggests that ssm1 mutant is involved in ion homeostasis and osmotic compensation in plant. Molecular cloning of the genomic DNA flanking T-DNA insert of ssm1 mutant was achieved by mutant genomic DNA library screening. T-DNA insertion appeared in the first exon of an open reading frame on F3M18.7, which is the same as AtSYP61. SSM1 is SYP61/OSM1 that is a member of the SNARE superfamily of proteins required for vesicular/target membrane fusions and factor related to abiotic stress.

The Relationship between the Anterior Cruciate Ligament Tear and the Posterior Cruciate Ligament Index on MRI Findings (자기공명영상 상 전방십자인대 파열과 후방십자인대 곡선값의 연관성)

  • Kang Jae Do;Kim Kwang Yul;Kim Hyung Cheon;Lee Sung Chun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.109-114
    • /
    • 2002
  • Propose : The purpose of this retrospective study was to test the posterior cruciate ligament (PCL index) for diagnosis of a tear of the anterior cruciate ligament (ACL) by means of MR imaging. Materials and Methods : From Mar. 1997 to Feb. 2001, concomitant magnetic resonance imaging (MRI) and knee joint arthroscopy were performed in 56 patients of either pain or instability of the knee. The shortest distance between the femoral and tibial attachment of PCL (X) and the distance from that line to the tip of the arc marked by the PCL (Y) on the sagittal plane images were measured. The quotient of these two parameters (Y/X) defined the PCL index. Results : Using MRI diagnosis, there were 35 patients diagnosed with ACL rupture and 21 patients were ruled out of ACL injury. Using arthroscopy, 32 of the 35 patients diagnosed by MRI showed ACL rupture, and 20 of the 21 patients were ruled out of ACL injury. The mean PCL index was 0.40 in the 33 patients diagnosed with ACL rupture through arthroscopy. The mean PCL index was 0.23 in 23 patients with an uninjured ACL through arthroscopy. In 33 patients with ruptured ACL, this value exceeds 0.31. The index value was 0.31 in 3 patients with uninjured ACL. The value of the index was not above 0.31 with an uninjured ACL. PCL index on MRI had a sensitivity of $91\%$ and a specificity of $94\%$ for determining the status of the anterior cruciate ligament. Conclusion : Injury to the ACL changes the PCL index markedly. In diagnostically unreliable MR images, amelioration of the PCL index could help in the diagnosis of ACL injury.

  • PDF

Effect of Attenuation Correction, Scatter Correction and Resolution Recovery on Diagnostic Performance of Quantitative Myocardial SPECT for Coronary Artery Disease (감쇠보정, 산란보정 및 해상도복원이 정량적 심근 SPECT의 관상동맥질환 진단성능에 미치는 효과)

  • Hwang, Kyung-Hoon;Lee, Dong-Soo;Paeng, Jin-Chul;Lee, Myoung-Mook;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.5
    • /
    • pp.288-297
    • /
    • 2002
  • Purpose: Soft tissue attenuation and scattering are major methodological limitations of myocardial perfusion SPECT. To overcome these limitations, algorithms for attenuation, scatter correction and resolution recovery (ASCRR) is being developed, while quantitative myocardial SPECT has also become available. In this study, we investigated the efficacy of an ASCRR-corrected quantitative myocardial SPECT method for the diagnosis of coronary artery disease (CAD). Materials and Methods: Seventy-five patients (M:F=51:24, $61.0{\pm}8.9$ years old) suspected of CAD who underwent coronary angiography (CAG) within $7{\pm}12$ days of SPECT(Group-I) and 20 subjects (M:F=10:10, age $40.6{\pm}9.4$) with a low likelihood of coronary artery disease (Group-II) were enrolled. Tl-201 rest/ dipyridamole-stress Tc-99m-MIBI gated myocardial SPECT was performed. ASCRR correction was peformed using a Gd-153 line source and automatic software (Vantage-Pro; ADAC Labs, USA). Using a 20-segment model, segmental perfusion was automatically quantified on both the ASCRR-corrected and uncorrected images using an automatic quantifying software (AutoQUANT; ADAC Labs.). Using these quantified values, CAD was diagnosed in each of the 3 coronary arterial territories. The diagnostic performance of ASCRR-corrected SPECT was compared with that of non-corrected SPECT. Results: Among the 75 patients of Group-I, 9 patients had normal CAG while the remaining 66 patients had 155 arterial lesions; 61 left anterior descending (LAD), 48 left circumflex (LCX) and 46 right coronary (RCA) arterial lesions. For the LAD and LCX lesions, there was no significant difference in diagnostic performance. In Group-II patients, the overall normalcy rate improved but this improvement was not statistically significant (p=0.07). However, for RCA lesions, specificity improved significantly but sensitivity worsened significantly with ASCRR correction (both p<0.05). Overall accuracy was the same. Conclusion: The ASCRR correction did not improve diagnostic performance significantly although the diagnostic specificity for RCA lesions improved on quantitative myocardial SPECT. The clinical application of the ASC-RR correction requires more discretion regarding cost and efficacy.

The Effect of Mean Brightness and Contrast of Digital Image on Detection of Watermark Noise (워터 마크 잡음 탐지에 미치는 디지털 영상의 밝기와 대비의 효과)

  • Kham Keetaek;Moon Ho-Seok;Yoo Hun-Woo;Chung Chan-Sup
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.4
    • /
    • pp.305-322
    • /
    • 2005
  • Watermarking is a widely employed method tn protecting copyright of a digital image, the owner's unique image is embedded into the original image. Strengthened level of watermark insertion would help enhance its resilience in the process of extraction even from various distortions of transformation on the image size or resolution. However, its level, at the same time, should be moderated enough not to reach human visibility. Finding a balance between these two is crucial in watermarking. For the algorithm for watermarking, the predefined strength of a watermark, computed from the physical difference between the original and embedded images, is applied to all images uniformal. The mean brightness or contrast of the surrounding images, other than the absolute brightness of an object, could affect human sensitivity for object detection. In the present study, we examined whether the detectability for watermark noise might be attired by image statistics: mean brightness and contrast of the image. As the first step to examine their effect, we made rune fundamental images with varied brightness and control of the original image. For each fundamental image, detectability for watermark noise was measured. The results showed that the strength ot watermark node for detection increased as tile brightness and contrast of the fundamental image were increased. We have fitted the data to a regression line which can be used to estimate the strength of watermark of a given image with a certain brightness and contrast. Although we need to take other required factors into consideration in directly applying this formula to actual watermarking algorithm, an adaptive watermarking algorithm could be built on this formula with image statistics, such as brightness and contrast.

  • PDF

The Current Status of Multidrug-Resistant Tuberculosis in One Tertiary Hospital in Busan, 2005~2009 (일개 부산지역 3차 병원에서 관찰한 다제내성 결핵의 실태, 2005~2009)

  • Yoon, Neul-Bom;Lee, Sung-Woo;Park, Su-Min;Jeong, Il-Hwan;Park, So-Young;Han, Song-Yee;Lee, Yu-Rim;Jung, Jin-Kyu;Kim, Joon-Mo;Kim, Su-Young;Um, Soo-Jung;Lee, Soo-Keol;Son, Choon-Hee;Hong, Young-Hee;Lee, Ki-Nam;Roh, Mee-Sook;Kim, Kyeong-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.2
    • /
    • pp.120-125
    • /
    • 2011
  • Background: Although the prevalence of pulmonary tuberculosis has progressively decreased all over the world, drug-resistant tuberculosis is major obstacle in treating tuberculosis. This study was performed to examine the current prevalence and risk factors of drug resistant tuberculosis in a single tertiary hospital in Busan, Korea. Methods: We enrolled 367 patients with active pulmonary tuberculosis on a retrospective basis who had undergone mycobacterium culture and drug sensitivity tests between January 2005 and December 2009. We analyzed all clinical and radiographic parameters to find predictors related to drug resistant tuberculosis. Results: At least one incident of drug resistance was found in 75 (20.4%) patients. Isoniazid (18.8%) was the most frequent resistant drug, followed by rifampin (10.9%), ethambutol (7.1%), streptomycin (4.9%), and fluoroquinolone (2.7%). Resistance to second-line drugs was found in 37 (10.1%) patients. Multidrug resistance and extensively drug resistance was evident in 39 (10.6%) and 4 (1.1%) patients, respectively. Using multiple logistic regression analysis, history of previous treatment including relapse (odd ratio [OR], 11.3; 95% confidence interval [CI], 4.92~26.08; p<0.01), treatment failure (OR, 24.1; 95% CI, 5.65~102.79; p<0.01) and an age of below 46 years-old (OR, 3.8; 95% CI, 1.62~8.65; p<0.01) were found to be independent predictors of multidrug resistant tuberculosis. Conclusion: We found that the prevalence of drug resistant tuberculosis was considerably high. A careful consideration for possible drug resistant tuberculosis is warranted in patients with a history of previous treatment or for younger patients.

Analysis of Heterogeneous Tree-Ring Growths of Pinus densiflora with Various Topographical Characteristics in Mt. Worak Using GIS (GIS 기법을 이용한 지형적 특성에 따른 월악산 소나무 연륜생장의 이질성 규명)

  • 서정욱;김재수;박원규
    • The Korean Journal of Ecology
    • /
    • v.23 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • To analyze the relationship between climatic factors (monthly temperatures and precipitations) and the radial growths or Pinus densiflora with different topographical settings in Worak National Park, Korea, 20 stands were chosen and 10 trees were selected from each stand. After crossdating, each ring-width series was double detrended (standardized) by fitting first a negative exponential or straight regression line and secondly a 60-year cubic spline. The growth patterns coud be categorized by four groups using cluster analysis. Cluster Ⅰ stand has north aspect, but others have south or southwest aspects. Cluster Ⅰ (one), cluster Ⅱ (ten), and cluster Ⅲ (two) stands are located in lower. elevation (305∼580 m), however, cluster Ⅳ (seven) stands are located in higher elevation, mostly in 560~870 m. Cluster Ⅱ and Ⅲ stands are located at similar elevation with the same aspect, however, cluster Ⅱ stands are located on more rocky and stiff slope with shallow soil depth. The response functions were used to examine the difference in the relationships between climatic factors and tree growths among the 4 cluster chronologies. The climatic factors are not limiting the growth in the cluster Ⅰ stand as highly as in other cluster plots because of rather mesic conditions in the north slope. The precipitation in the spring appears to be the main limiting factor in the cluster Ⅱ stands. The topographical characteristics of the sites of cluster Ⅱ, shallow soil depths on the rocky slope in the south aspect at lower elevation, may enhance the sensitivity of growth to moisture stress. In cluster Ⅲ and cluster Ⅳ, winter and spring temperature prior to the growth become more important than for cluster Ⅱ. This pattern is com-mon for Pinus densiflora trees growing in higher. elevation (equation omitted 800 m) in South Korea. It nay be re-lated with preconditioning effects of temperature as the temperature decreases with increasing elevation (cluster Ⅳ) or in the valley (cluster Ⅲ). The results obtained by tree-ring analysis were digitalized by GIS and spatio-temporal information on tree-ring data and topographic setting were analyzed and displayed simultaneously. The results of this study can be used to predict the future change of Pinus densiflora ecosystem to climate change expected in central Korea.

  • PDF

Empirical Study of Simple Grade Facilities Gap Utilizing Micro Simulation Analysis (Micro Simulation을 활용한 도시부 단순입체시설 분합류 구간간격에 관한 실증연구)

  • Kim, Young-Il;Rho, Jeong-Hyun;Kim, Tae-Ho;Park, Jun-Tae
    • International Journal of Highway Engineering
    • /
    • v.14 no.2
    • /
    • pp.63-72
    • /
    • 2012
  • Current analysis method drives an irrationality a road, signal operation and cause confusion of road such as weaving, bottleneck being not including main traffic flow in analysis subject. Therefore, this research develops analysis method of simple grade facilities to grasp target equipment relationship effect as virtue process to grasp effect of simple grade facilities in city and there is the purpose to apply optimum space of analysis intersection. In this paper, get at effect of simple grade facilities in urban area, as well as, develop new analysis method of simple grade facilities and adapt optimal interval of intersection point. New method of this paper reasonably estimated to optimal interval of the traffic flow(diverge area, merge area). As research result, analysis method to present in this research could clarify vague part of existing analysis method and presume reasonable result. Optimal interval of diverge and merge area with facilities was appeared more then 65m from the main line and more then 45m from the frontage road. Meaning of this paper as follow. First, the effect of simple grade facilities estimate. as consider optimal interval of simple grade facilities in urban can plan efficiently operation planning of road and signal in connection with nearby intersection. Second, new method then previous methods. planner of transportation easily access due to run parallel with existing method. Third, new method is contained through traffic volumes. the existing method did not reflect one. and this new method reduce error to the minimum. when analysis of intersection and link. Fourth, using the new method propose improvement plan with road operation and signal operation.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

Evaluation of a Serodiagnostic Method for Tuberculosis by Using Secreted Protein Antigens of Mycobacterium Tuberculosis (결핵균 분비항원을 이용한 결핵의 혈청학적 진단 방법에 대한 평가)

  • Bai, Gill-Han;Park, Eun-Mi;Kim, Sang-Jae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.315-323
    • /
    • 2000
  • Background : An immunochromatographic assay (ICT Diagnostics) which facilitates the diagnosis of tuberculosis(TB) by detecting serum antibodies mainly directed against specific 38KDa of Mycobacterium tuberculosis has come into the market. The test consists of a cardboard folding device containing nitrocellulose strip and absorbent pads. The whole procedure is completed within 15 min and does not require any additional equipment. The test has been reported to be sensitive and specific in diagnosing active TB. Thus the test had been evaluated with sera from TB patients and TB-free subjects. Method : Sera from patients with active pulmonary tuberculosis(40 sputum positives for Mycobacterium tuberculosis, 79 sputum negatives, and 3 extrapulmonary tuberculosis) were obtained from the Double-Cross Chest Clinic of the Korean National Tuberculosis Association (KNTA) in Seoul. The control group consisted of TB-free 68 subjects(21 children under 7 years old and 47 healthy staff members of KNTA). Results : Nine out of 68(13.2%) TB-free controls had positive antibody response. Total 106 of 122(86.9%) radiologically active patients had positive antibodies while 16 (13.1%) showed negative reaction. Antibody was detected in 38 of 40(95.0%) sputum positive patients and 68 of 82(82.9%) sputum negative patients who were under the antituberculosis chemotherapy. The sensitivity and specificity were all 87% and the positive predictive value was 92.2% while the negative predictive value was 78.7%, when the prevalence of TB in the sample was 64.2%. Our results clearly show that the detection of antibodies which mainly react with the 38KDa antigen of M. tuberculosis is not suitable as the first-line method of diagnosis but considered only as an adjunctive test to standard techniques of tuberculosis diagnosis. when considering its high false positivity.

  • PDF