• Title/Summary/Keyword: line sensitivity

Search Result 689, Processing Time 0.026 seconds

A Development of On-Line Guidance System for Power System (전력 계통 이상 상태 Guidance System 개발)

  • Oh, Seung-Ryle;Baek, Young-Sik;Kim, Jung-Nyun;Han, Moo-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.47-49
    • /
    • 2002
  • Recently, the power system has a trend of a sustaining growth in electric power demand with large-sized formation. In this situation, current states can be definitely comprehended to operate security and economic power system. Also, corrective actions must be performed for the violation of bus voltage and line overload. In the security and economy with on-line, It is desirable that the situations of violation are promptly removed to operate power system effectively. This paper deals with the development of application, Kangyang Steel Works' Power System Guidance System, for voltage and overload correction on base case using Generator-Voltage Sensitivity List(GVSL) and Generator Shifter Factor List(GSFL). Also, to show the superiority and economical efficiency of the proposed application, we simulate the Kangyang Steel Works' Power System.

  • PDF

An Approach To Alloctating Transmission System Reliabity Cost (송전계통의 신뢰도 비용 산정 방안에 대한 연구)

  • Chung, Koo-Hyung;Shin, Young-Kyun;Kim, Bal-Ho H.;Im, Sung-Hwang
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.515-517
    • /
    • 2001
  • The efficient and rational transmission rate system is one of the crucial factors in creation of fair and competitive electricity market. Transmission charge can be largely categorized into the line usage charge, system reliability maintenance charge, access charge and others. Therefore, transmission rate structure should be able to reflect these cost components reasonably. This Paper suggests an approach that could be used for the reasonable calcuation of transmission reliability costs with reflection of line sensitivity and line outage rate.

  • PDF

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

A Study on the Selection of the Optimum Railroad Line using VE-LCC Analysis (VE-LCC 분석을 통한 철도의 최적노선 선정방안 연구)

  • Shin Tae-Kyun;Son Seok-Ku;Lee Seung-Hoon;Koo Kyo-Jin;Hyun Chang-Taek
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.315-320
    • /
    • 2003
  • Selecting a railroad line requires the comparative evaluation of various elements. As a systematic approach to this selection it will be necessary to apply the VE study and the LCC analysis. This study proposes a methodology for selecting the optimum line of the ralroad using VE-LCC analysis. The VE study is performed by following four steps : Information analysis, Function analysis, Alternative evaluation, and Optimum plan selection. The economics evaluation in VE study is using LCC analysis and Sensitivity analysis. Cost items in LCC analysis are classified into bridge, tunnel, rail, and earthwork. We could select the optimum alte-rnatives considering not only cost elements hut also various evaluation element in VE-LCC analysis. The synthetic evaluation process of relative value composition and weighted matrix evaluation

  • PDF

Field Test of On-line Monitoring System for Oil-filled Power Transformers (대용량 유입변압기의 온라인 진단시스템 적용연구)

  • Lee, Chang-R.;Kim, Yong-H.;Kim, Nam-H.;Kim, Jung-H.;Yoon, Ja-H.;Nam, Keuk-C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1644-1646
    • /
    • 2003
  • This paper presents recent studies on the on-line insulation monitoring and diagnostic systems for transformers developed by HHI. Sufficiently high sensitivity and accuracy for practical use were achieved for the system, combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

Damping Inter-area Low Frequency Oscillations in Large Power Systems with $H_{\infty}$ Control of TCSC PARTI : TCSC Siting (TCSC의 $H_{\infty}$ 제어에 의한 대규모 전력계통의 지역간 저주파진동 억제 PartI : 설치지점 선정)

  • Kim, Yong-Gu;Sim, Gwan-Sik;Song, Seong-Geun;Kim, Yeong-Hwan;Nam, Hae-Gon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.5
    • /
    • pp.226-232
    • /
    • 2000
  • This paper presents application results of the augmented matrix eigen-sensitivity theories to TCSC siting problem for damping the inter-area low frequency oscillation in the large KEPCO system. First and second-order eigen-sensitivities of the inter-area low frequency oscillation in the large KEPCO system. First and second-order eigen-sensitivities of the inter-area mode are computed fro changes in susceptance of the transmission lines. The lines having high sensitivity are chosen as the initial candidates for installing TCSC. Then for each of the chosen candidates, Bodeplot of the transfer function with line susceptance as the input and the bus voltage at one side of the line as the output is computed. Using the Bode plots, the lines having any zeros near the inter-area mode are screened out since design of TCSC controller is very difficult in such a case. The $H_{\infty}$ TCSC controller installed at any finally chosen candidate is found to be effective in damping the inter-area oscillation, and the proposed TCSC siting algorithm is proved to be valid. Design of $H_{\infty}$ controller is described in Part IIof this paper.

  • PDF

Improvement in Sensitivity by Increasing the Frequency of SAW Sensors for DNA Detection (DNA 측정용 SAW 센서의 주파수 증대에 의한 감도향상)

  • Sakong, Jung-Yul;Kim, Jae-Ho;Lee, Soo-Suk;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.42-47
    • /
    • 2007
  • In this paper. we have studied improvement in sensitivity by increasing the frequency of SAW sensors for detecting the immobilization and hybridization of DNA. The sensor consists of twin SAW delay lines operating at 200MHz, a sensing channel and a reference channel. fabricated on $36^{\circ}$ rotated Y-cut X-propagation $LiTaO_3$ crystals. The optimum concentration of probe and target DNA was decided for the improvement of detection mechanism. and digital syringe pump system was used to reduce the human errors. The hybridization between immobilized probe DNA and target DNA on the gold-coated delay line results in mass loading on the delay line of the sensing channel. Thus, the relative frequency change was monitored in relation to the mass loading. The measurement results showed a good response of the sensor to the DNA hybridization with a maximum sensitivity level up to 0.066ng/m1/Hz.

Sensitivity Analysis of Air Pollutants Dispersion Model in the Road Neighboring Area Due to the Line Source -The Object on ISCST3, CALINE4 Model- (선 오염원에 의한 도로변 지역으로의 대기확산모델의 민감도 분석 - ISCST3, CALINE4 모델을 중심으로 -)

  • Ahn, Won-Shik;Park, Myung-Hee;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.16 no.6
    • /
    • pp.715-723
    • /
    • 2007
  • The air pollutant emission is mainly caused by line sources in urban area. For example, the annually totaled air pollutant emission is known to consist of about 80% of line sources in Daegu. Hence, the appropriate assessment on the air pollutants of line sources is very important for the atmospheric environmental management in urban area. In this study, we made a comparative study to evaluate suitable dispersion model for estimating the air pollution from line sources. Two air pollution dispersion models, ISCST3 and CALINE4 were the subject of this study. The results were as follows; In the assessment of air pollution model, ISCST3 was found to have 4 times higher concentration than CALINE4. In addition, actual data obtained by measurement and estimated values by CALINE4 were generally identical. The air pollution assessment based on ISC3 model produced significantly lower values than actual data. The air pollution levels estimated by ISCST3 were very low in comparison with the observational values.

Design of Printed Circuit Board for Clock Noise Suppression in T-DMB RF Receiver (지상파 DMB RF 수신기에서 클락 잡음 제거를 위한 인쇄 회로 기판 설계)

  • Kim, Hyun;Kwon, Sun-Young;Shin, Hyun-Chol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.11
    • /
    • pp.1130-1137
    • /
    • 2009
  • This paper proposes a new clock routing design for suppressing clock harmonic effects in a Printed Circuit Board (PCB) for a terrestrial Digital Multimedia Broadcasting(DMB) system. Typical crystal reference frequencies that are widely used in DMB tuners are 16.384 MHz, 19.2 MHz, 24.576 MHz. When the high-order harmonic components of these reference frequencies fall near the RF channel frequencies, receiver sensitivity of the tuners is seriously degraded. In this work, we propose a new clock routing design in order to address the clock harmonic coupling issue. The proposed design incorporates two inductors for isolating the clock ground from the main ground, and adopts a new strip line-style routing instead of the conventional microstrip line style routing to minimize the overlap area with the main ground. As a result, the RF sensitivity of the T-DMB tuner is improved by 2 dB.

Influencing Factors on Sensitivity of Pressure Decay Test for Membrane Damage Assessment (막 손상 측정을 위한 압력손실시험의 감도에 영향을 미치는 인자)

  • Lee, Yong-Soo;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.367-373
    • /
    • 2017
  • Pressurized membrane module systems, including hollow fiber type of Microfiltration (MF) and Ultrafiltration (UF) membranes are being increasingly used in drinking water treatment due to their high removal efficiency of pathogen. However, when fibers are damaged in pressurized membrane system, the pathogen will be able to penetrate the membrane. Therefore, it is essential to guarantee the regulatory requirements for water quality by an effective on-line or off-line condition integrity monitoring methods. Recently, pressure decay test (PDT) which is one of membrane integrity tests has been reflected to drinking water treatment plants using pressurized membrane module. In this paper, three different method were used to perform PDT and three different sensitivity values were analyzed through experiments. Three types of direct integrity test methods were applied to pressure feed side, filtrate side and bidirectional pressure decay test. The results of these experiments show that the sensitivity was increasing when the volume of pressurized gas was decreasing. The sensitivity is inversely proportional to the gas volume. Furthermore, it is desirable to increase pressure difference between feed side and permeate side in order to achieve higher sensitivity in the PDT by membrane damage.