• Title/Summary/Keyword: line sampling

Search Result 376, Processing Time 0.025 seconds

VHDL Implementation of GEN2 Protocol for UHF RFID Tag (RFID GEN2 태그 표준의 VHDL 설계)

  • Jang, Il-Su;Yang, Hoon-Gee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12A
    • /
    • pp.1311-1319
    • /
    • 2007
  • This paper presents the VHDL implementation procedure of the passive RFID tag operating in Ultra High Frequency. The operation of the tag compatible with the EPCglobal Class1 Generation2(GEN2) protocol is verified by timing simulation after synthesis and implementation. Due to the reading range with relatively large distance, a passive tag needs digital processor which facilitates faster decoding, encoding and state transition for enhancement of an interrogation rate. In order to satisfy linking time, the pipe-line structure is used, which can minimize latency to serial input data stream. We also propose the sampling strategy to decode the Preamble, the Frame-sync and PIE symbols in reader commands. The simulation results with the fastest data rate and multi tags environment scenario show that the VHDL implemented tag performs faster operation than GEN2 proposed.

Output characteristics of ac excited $CO_2$ laser as a adjusting a phase angle and frequency (위상각와 주파수 제어에 따른 상용주파 AC 여기 방식의 펄스형 $CO_2$ 레이저 전원장치 개발에 관한 연구)

  • Chung, Hyun-Ju;Kim, Do-Wan;Lee, Dong-Hoon;Kim, Joong-Mann;Kim, Mee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2098-2100
    • /
    • 2000
  • We propose pulsed $CO_2$ laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch) circuit and a PIC one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum laser output was obtained about 23W at pulse repetition rate of 60Hz, total gas mixture of $CO_{2}/N_{2}$/He = 1/9/15, SCR gate trigger angle 90$^{\circ}$, and total pressure of 18Torr.

  • PDF

A Design of Pipelined Analog-to-Digital Converter with Multi SHA Structure (Multi SHA 구조의 파이프라인 아날로그-디지털 변환기 설계)

  • Lee, Seung-Woo;Ra, Yoo-Chan;Shin, Hong-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.2A
    • /
    • pp.114-121
    • /
    • 2005
  • In this paper, Pipelined A/D converter with multi SHA structure is proposed for high speed operation. The proposed structure incorporates a multi SHA block that consists of multiple SHAs of identical characteristics in parallel to improve the conversion speed. The designed multi SHA is operated by non-overlapping clocks and the sampling speed can be improved by increasing the number of multiplexed SHAs. Pipelined A/D converter, applying the proposed structure, is designed to satisfy requirement of analog front-end of VDSL modem. The measured INL and DNL of designed A/D converter are $0.52LSB{\sim}-0.50LSB\;and\;0.80LSB{\sim}-0.76LSB$, respectively. It satisfies the design specifications for VDSL modems. The simulated SNR is about 66dB which corresponds to a 10.7 bit resolution. The power consumption is 24.32mW.

Commercial frequency AC discharge magnetic stimulation operating characteristics (상용교류방전 자기자극장치의 동작특성)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2685-2692
    • /
    • 2009
  • We propose pulsed magnetic stimulation below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control magnetic stimulation output. In this magnetic stimulation, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch)circuit and a DSP & FPGA are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum magnetic stimulation output was obtained about 33W at pulse repetition rate of 60Hz, total 40, 80, 120, $160^{\circ}$, SCR gate trigger angle $90^{\circ}$ and total output.

A Research for Removing ECG Noise and Transmitting 1-channel of 3-axis Accelerometer Signal in Wearable Sensor Node Based on WSN (무선센서네트워크 기반의 웨어러블 센서노드에서 3축 가속도 신호의 단채널 전송과 심전도 노이즈 제거에 대한 연구)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.137-144
    • /
    • 2011
  • Wireless sensor network(WSN) has the potential to greatly effect many aspects of u-healthcare. By outfitting the potential with WSN, wearable sensor node can collects real-time data on physiological status and transmits through base station to server PC. However, there is a significant gap between WSN and healthcare. WSN has the limited resource about computing capability and data transmission according to bio-sensor sampling rates and channels to apply healthcare system. If a wearable node transmits ECG and accelerometer data of 4 channel sampled at 100 Hz, these data may occur high loss packets for transmitting human activity and ECG to server PC. Therefore current wearable sensor nodes have to solve above mentioned problems to be suited for u-healthcare system. Most WSN based activity and ECG monitoring system have been implemented some algorithms which are applied for signal vector magnitude(SVM) algorithm and ECG noise algorithm in server PC. In this paper, A wearable sensor node using integrated ECG and 3-axial accelerometer based on wireless sensor network is designed and developed. It can form multi-hop network with relay nodes to extend network range in WSN. Our wearable nodes can transmit 1-channel activity data processed activity classification data vector using SVM algorithm to 3-channel accelerometer data. ECG signals are contaminated with high frequency noise such as power line interference and muscle artifact. Our wearable sensor nodes can remove high frequency noise to clear original ECG signal for healthcare monitoring.

Radionuclides of Ground waters in Busan (부산지역 지하수의 방사성물질 특성)

  • Jeon, Dae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.51-61
    • /
    • 2009
  • This study was performed to research the characteristic of radionuclides of 80 groundwater monitoring networks in Busan. According to the research, average concentration of Uranium was $4.33\;{\mu}g/L$, maximum concentration of Uranium was $171.55\;{\mu}g/L$ among the 80 sampling sites. One sample exceeded the Proposal standard of drinking water in USA in Uranium ($30\;{\mu}g/L$) and four samples exceeded the recommendatory value of WHO about Uranium ($15\;{\mu}g/L$). Radon and gross-$\alpha$ concentration of all samples were far less than the Proposal standard of drinking water in USA. In this study average concentration of radionuclides in underground water wasn't too high, but needed to control the concentration of them to prevent exposure to the people. And it needs to be taken measures in some sites with high concentration of Uranium by closing the pipe line or etc through more studies.

Distribution of Airborne Fungi, Particulate Matter and Carbon Dioxide in Seoul Metropolitan Subway Stations (서울시 일부 지하철역 내 부유 진균, 입자상 물질, 이산화탄소의 분포 양상)

  • Kim, Ki-Youn;Park, Jae-Beom;Kim, Chi-Nyon;Lee, Kyung-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.4
    • /
    • pp.325-330
    • /
    • 2006
  • Objectives: The aims of this study were to examine the level of airborne fungi and environmental factors in Seoul metropolitan subway stations and to provide fundamental data to protect the health of subway workers and passengers. Methods: The field survey was performed from November in 2004 to February in 2005. A total 22 subway stations located at Seoul subway lines 1-4 were randomly selected. The measurement points were subway workers' activity areas (station office, bedroom, ticket office and driver's seat) and the passengers' activity areas (station precincts, inside train and platform). Air sampling for collecting airborne fungi was carried out using a one-stage cascade impactor. The PM and CO2 were measured using an electronic direct recorder and detecting tube, respectively. Results: In the activity areas of the subway workers and passengers, the mean concentrations of airborne fungi were relatively higher in the workers' bedroom and station precinct whereas the concentration of particulate matter, $PM_{10}\;and\;PM_{2.5}$, were relatively higher in the platform, inside the train and driver's seat than in the other activity areas. There was no significant difference in the concentration of airborne fungi between the underground and ground activity areas of the subway. The mean $PM_{10}\;and\;PM_{2.5}$ concentration in the platform located at underground was significantly higher than that of the ground (p<0.05). Conclusions: The levels of airborne fungi in the Seoul subway line 1-4 were not serious enough to cause respiratory disease in subway workers and passengers. This indicates that there is little correlation between airborne fungi and particulate matter.

A Study on the Organization, Function and Management of Health Subcenters in Korea (우리나라 보건지소 조직, 기능 및 관리개선에 관한 연구)

  • 정영일;강성홍
    • Health Policy and Management
    • /
    • v.2 no.2
    • /
    • pp.57-89
    • /
    • 1992
  • This study is aimed both to reorient the Health net-works focused to Health Subcenters in times of development of local autonomy in Korea and to collect the fundamental data such as attitude and practice of the directors of Health Subcenter. The materials are collected from 134 out of 258 sampling directors of Health Subcenters with a questionaire by mailing(respond rate 51.9%). The major findings of this fundamental data are as follows. 1. Current average number of outpatients cared by a director of Health Subcenter is found to be 21.6. 2. The directors of Health Subcenter have little deducted hours for Public Health Programme. 3. Number of the Preventive Health Programme worked by a director of Health Subcenter is from 0 to 3. The most major group worked only 1 programme marked at 69.4%. 4. The directors of Health Subcenter express approval opinin marked at 80.2% that their qualification to appoint has to finish intern course. 5. The average diagnosis allowance a month is approximately twenty hundred thousand won. 6. Most of Health Subcenter(market at 94%) adopted a self-supporting account system. 7. The most complaining subject of directors of Health Subcenter is their working environment. The second complaining subject is governmental officier's interference. 8. The average number of outpatients cared by a director of Health Subcenter is found to be certain differentials by their marriage and the duration of employment. Some proposals of development on Health Subcenter based on the result of this research is as follows : 1. The reorganization on Health Subcenter under line of National Health Center Net-work 2. The psychological reorientation of directors of Health Sucenter and officers. 3. Autonomy management of Health Subcenter. 4. Reorientation of status on directors of Health Subcenter.

  • PDF

Design and Implementation of Wireless Asynchronous UWB System for low-rate low power PAN applications (저속도 저전력 PAN 응용을 위한 무선 비동기식 UWB 시스템 설계 및 구현)

  • Choi, Sung-Soo;Koo, In-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.11
    • /
    • pp.2021-2026
    • /
    • 2007
  • In the parer, we design a non-coherent UWB system by adopting the architecture of a simplified asynchronous transmission and the edge-triggered pulse transmission, which makes e system performance independent of the share of the transmitted waveform, robust to multipath channels. The designed non-coherent UWB transceiver architecture has an advantage of the simple realization since any mixer, high-speed correlator, and high-sampling A/D converter are not necessary at the cost of performance degradation of about 3dB. Further, the designed non-coherent UWB transceiver is actually implemented with the wireless CANVAS prototype testbed in short range indoor application environments such as a lecture room. The implemented prototype testbed is proven to offer the data rate of 115kbps on the conditions of Peer-to-Peer(P-to-P) in the indoor channel within the range of about 10m.

A Design of ADC with Multi SHA Structure which for High Data Communication (고속 데이터 통신을 위한 다중Multi SHA구조를 갖는 ADC설계)

  • Kim, Sun-Youb
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1709-1716
    • /
    • 2007
  • In this paper, ADC with multi SHA structure is proposed for high speed operation. The proposed structure incorporates a multi SHA block that consists of multiple SHAs of identical characteristics in parallel to improve the conversion speed. The designed multi SHA is operated by non-overlapping clocks and the sampling speed can be improved by increasing the number of multiplexed SHAs. Pipelined A/D converter, applying the proposed structure, is designed to satisfy requirement of analog front-end of VDSL modem. The measured INL and DNL of designed A/D converter are $0.52LSB{\sim}-0.50LSB$ and $0.80LSB{\sim}-0.76LSB$, respectively. It satisfies the design specifications for VDSL modems. The simulated SNR is about 66dB which corresponds to a 10.7 bit resolution. The power consumption is 24.32mW.