• 제목/요약/키워드: line monitoring

검색결과 1,481건 처리시간 0.033초

On-line Monitoring of IPTG Induction for Recombinant Protein Production Using an Automatic pH Control Signal

  • Hur Won;Chung Yoon-Keun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권4호
    • /
    • pp.304-308
    • /
    • 2005
  • The response of IPTG induction was investigated through the monitoring of the alkali consumption rate and buffer capacity during the cultivation of recombinant E. coli BL21 (DE3) harboring the plasmid pRSET-LacZ under the control of lac promoter. The rate of alkali consumption increased along with cell growth, but declined suddenly after approximately 0.2 h of IPTG induction. The buffer capacity also declined after 0.9 h of IPTG induction. The profile of buffer capacity seems to correlate with the level of acetate production. The IPTG response was monitored only when introduced into the mid-exponential phase of bacterial cell growth. The minimum concentration of IPTG for induction, which was found out to be 0.1 mM, can also be monitored on-line and in-situ. Therefore, the on-line monitoring of alkali consumption rate and buffer capacity can be an indicator of the metabolic shift initiated by IPTG supplement, as well as for the physiological state of cell growth.

DTS를 활용한 광복합 지중 배전계통 실시간 감시시스템 개발 및 성능평가 (A Development and Performance Assessment of On-Line Monitoring System for Optical Fiber Composite Underground Distribution Network using DTS)

  • 조진태;김주용;이학주;조휘창;최명호
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.115-121
    • /
    • 2011
  • Intelligent distribution equipment is inevitable to realize self-healing which is one of smart grid functions in distribution network. Therefore, most of distribution equipment have been developed with self diagnostic sensors. However, it is not effective to construct on-line monitoring system for underground distribution cable because of high cost and low sensitivity. Recently, optical fiber composite cable is being considered for communication and power delivery in order to cope with increasing communication in distribution network. This paper presents the design and performance assessment results of underground cable on-line monitoring system using DTS(Distributed Temperature Sensing) and optical fiber composite underground cable.

자속검출법에 의한 유도형 리니어모터의 성능 온.라인 모니터링 시스템 구현 (LIMs Performance On-Line Monitoring System by Measuring Airgap Flux from Search Coil)

  • 장석명;이성호;장건우;이성래;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.666-668
    • /
    • 2000
  • The LIMs performance on-line monitoring system is proposed by using LabVIEW software and A/D board. The on-line monitoring system set-up can measure input voltage. current, power, power factor, electromagnetic thrust, and efficiency etc. This paper reports data on LIM performance measured by the proposed on-line monitoring system.

  • PDF

Development and Application of Distributed Multilayer On-line Monitoring System for High Voltage Vacuum Circuit Breaker

  • Mei, Fei;Mei, Jun;Zheng, Jianyong;Wang, Yiping
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.813-823
    • /
    • 2013
  • On-line monitoring system is important for high voltage vacuum circuit breakers (HVCBs) in operation condition assessment and fault diagnosis. A distributed multilayer system with client/server architecture is developed on rated voltage 10kV HVCB with spring operating mechanism. It can collect data when HVCB switches, calculate the necessary parameters, show the operation conditions and provide abundant information for fault diagnosis. Ensemble empirical mode decomposition (EEMD) is used to detect the singular point which is regarded as the contact moment. This method has been applied to on-line monitoring system successfully and its satisfactory effect has been proved through experiments. SVM and FCM are both effective methods for fault diagnosis. A combinative algorithm is designed to judge the faults of HVCB's operating mechanism. The system's precision and stability are confirmed by field tests.

전력용 변압기의 온라인 PD 모니터링과 시험을 위한 UHF 기술 동향 (A Technical Trend on UHF Techniques for On-Line PD Monitoring and Site Testing for Transformer)

  • 김병우;김윤석;김창복;조수영;최영일;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1972-1973
    • /
    • 2007
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of a transformer. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

상태관측기를 이용한 PMSM의 On-Line 과부하 모니터링 시스템 (Observer-Based On-Line Overload Monitoring System of PMSM)

  • 장기찬;서석훈;우광준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.268-271
    • /
    • 2001
  • This paper presents observer-based on-line overload monitoring scheme for a PMSM(Permanent Magnet Synchronous Motor) drive system. Proposed scheme is to monitor overload status of motor drive system at remote place. The drive system is previously installed on main system and has no communication function. Proposed scheme consists of intelligent sensing head and monitoring part. Intelligent sensing head acquire motor 3-Phase currents and transmit data to monitoring part over serial communication interface. Monitoring part estimates motor speed using state observer. By comparing estimated speed with reference speed, we can detect motor fault. In this scheme observed information must coded and transmitted over a digital communication channel with finite capacity. We consider communication constraint as time delay and we design discrete-time observer. The proposed scheme is tested on the actual drive system.

  • PDF

대용량 유입변압기의 온라인 진단시스템 적용연구 (Field Test of On-line Monitoring System for Oil-filled Power Transformers)

  • 이창용;김용한;김남해;김정한;윤자홍;남극채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1644-1646
    • /
    • 2003
  • This paper presents recent studies on the on-line insulation monitoring and diagnostic systems for transformers developed by HHI. Sufficiently high sensitivity and accuracy for practical use were achieved for the system, combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

통합형 인-라인 오일 모니터링 센서의 제철설비 현장 적용사례 (Case Study on Integrated In-line Oil Monitoring Sensor for Machine Condition Monitoring of Steel Making Industry)

  • 공호성;한흥구;곽진수;장원수;임경근
    • Tribology and Lubricants
    • /
    • 제26권1호
    • /
    • pp.73-77
    • /
    • 2010
  • One of the important trends for condition monitoring in the 21st century is the development of smart sensors that will permit the cost-effective continuous monitoring of key machine equipments. In this study, an integrated in-line oil monitoring sensor assigned for continuous in situ monitoring multiple parameters of oil performance is presented. The sensor estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical density of oil in three optical wave-bands ('Red', 'Green' and 'Blue') and water content is evaluated as relative saturation of oil by water. In order to evaluate the sensor's effectiveness, the sensor was applied to several used oil samples in steel making industry and the results were compared with those measured by standard test methods.

Influence line- model correction approach for the assessment of engineering structures using novel monitoring techniques

  • Strauss, Alfred;Wendner, Roman;Frangopol, Dan M.;Bergmeister, Konrad
    • Smart Structures and Systems
    • /
    • 제9권1호
    • /
    • pp.1-20
    • /
    • 2012
  • In bridge engineering, maintenance strategies and thus budgetary demands are highly influenced by construction type and quality of design. Nowadays bridge owners and planners tend to include life-cycle cost analyses in their decision processes regarding the overall design trying to optimize structural reliability and durability within financial constraints. Smart permanent and short term monitoring can reduce the associated risk of new design concepts by observing the performance of structural components during prescribed time periods. The objectives of this paper are the discussion and analysis of influence line or influence field approaches in terms of (a) an efficient incorporation of monitoring information in the structural performance assessment, (b) an efficient characterization of performance indicators for the assessment of structures, (c) the ability of optimizing the positions of sensors of a monitoring system, and (d) the ability of checking the robustness of the monitoring systems applied to a structure. The proposed influence line- model correction approach has been applied to an integrative monitoring system that has been installed for the performance assessment of an existing three-span jointless bridge.

댐 제체 및 침투수 흐름의 지열학적 고찰 (A Study on Geothermal Characteristics of Dam Body and Seepage Flow)

  • 박동순;정우성;김형수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.75-85
    • /
    • 2006
  • In recent geotechnical engineering, geothermal approach has been on the horizon to deal with geoenvironmental issues, freezing and thawing problems, and seepage phenomenon in dams and embankments. In this study, geothermal characteristic through inner body of dams and its influence on the seepage flow were experimented by lab test and field instrumentation. Also, one of up-to-date temperature monitoring technique, called as multi-channel thermal line sensing, was evaluated its availability. As a result of lab test, it is found that the seepage flow has influence on the geothermal characteristic and a potential of finding phreatic line and seepage fluctuation could be possible by continuous temperature monitoring using thermal line sensing skills. These kine of geothermal information could be available to the modelling of water geo-structure interaction. Out of short-term field tests, clear water table and temperature distribution of a dam were easily found through temperature monitoring in holes located near a reservoir and holes within a depth of constant temperature layer. However, it is also found that the geothermal flow and finding seepage line could not be easily understandable through multi-channel temperature monitoring because of the existence of constant temperature field, thermal conductivity of soils and rocks, and unsaturated characteristics of geo-material. In this case, long-term geothermal monitoring is recommended to find sudden fluctuation of seepage line and amount of leakage.

  • PDF