• Title/Summary/Keyword: linac

Search Result 305, Processing Time 0.024 seconds

Experimental for Performance of electron 9un cathode electrode (Y-824) characteristics (전자총 캐소드전극(Y-824)의 특성실험)

  • Son, Y.G.;Kwon, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1552-1553
    • /
    • 2006
  • A thermionic gun of injector linac for pohang accelerator laboratory is required to generate beam pulse width less than 1 nsec. The gun uses cathode-grid assembly(EIMAC Y824) and operates up to 80 kV anode voltage. In order research characteristics of the electron gun, emission current from gun wear measured by the wall current monitor. In this paper the pulser system and characteristics of the emission current in region from 30 mA to 15 A are described.

  • PDF

The Status and Prospects of Accelerators in Radiation Industries (방사선 산업용 가속기의 현황과 전망)

  • Chai, Jong-Seo
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.101-110
    • /
    • 2012
  • This paper is described the review of several selected accelerators and the use of accelerators in various purposes. The electrostatic accelerators and RF accelerators have been developed before the second world war for the purpose of basic research of physics mainly. RF driven accelerators have been achieved higher energy and applied in medical and industrial use after 1980's. Accelerators have improved incorporating new technologies : axial and horizontal injection, stripping extraction, superconducting RF, computer control, superconducting magnet etc.. Also recent key technologies as BT and NT make the expansion of applications of the accelerators.

The Study of Latch-up (펄스감마선에 의한 DC/DC 컨버터의 Latch-up현상에 대한 연구)

  • Oh, Seung-Chan;Lee, Nam-Ho;Lee, Heung-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.719-721
    • /
    • 2012
  • In this study, we carried out transient radiation experiments for identify failure situation by a transient radiation effect on DC/DC converter device due to high energy ionizing radiation pulse induced to electronic device. This experiments were carried out using a 60 MeV electron beam pulse of the LINAC(Linear Accelerator) facility in the Pohang Accelerator Laboratory. In this experiment, we has found that the latch-up phenomena could be checked in more than $1.0{\times}10^8$rad(si)/sec condition.

  • PDF

Monte Carlo Based Planning System for a Beam Spoiler

  • 강세권;조병철;박희철;배훈식
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.56-56
    • /
    • 2003
  • For the treatment of superficial tumors like squamous cell carcinoma of the head and neck, 6 MV photon beam is not appropriate and a spoiler is widely used to increase dose in the buildup region, while preserving the skin sparing effect. However, commercially available treatment planning systems assume a normal unspoiled beam, thereby cannot predict the buildup dose with spoiler accurately. We aimed to implement a Monte Carlo (MC) based planning system to apply it to the radiation treatment of head and neck. Lucite with thickness of 10-mm was used for the beam spoiler with Siemens Primus 6 MV photon beam. BEAM/DOSXYZ MC system was employed to model the linac and the spoiler. To verify the calculation accuracy of MC simulations, the percent depth doses (PDDs) and profiles with and without spoiler were measured using a parallel-plate chamber. For the MC based planning, we adopted a hybrid interface system between Pinnacle (Philips, USA) and BEAM/DOSXYZ to support treatment parameters of Siemens linac and the spoiler. The measurements of PDDs and profiles agreed with the corresponding MC simulations within 2% (lSD), which demonstrate the reliability of our MC simulations. The spoiler generated electrons make a contribution to the absorbed dose up to depth of 2cm, which shows that the dominant source of increased dose from spoiler system is the contaminating electrons created by the spoiler. The whole procedures necessary for MC based treatment planning were performed seamlessly between Pinnacle and BEAM/DOSXYZ system. This ability helps to increase the clinical efficiency of the spoiler technique. In conclusion, we implemented a MC based treatment planning system for a 6 MV photon beam with a spoiler. We demonstrate sophisticated MC technique makes it possible to predict dose distributions around buildup region accurately.

  • PDF

Measurements and characterizations of cerenkov light in fiber-optic radiation sensor irradiated by high energy electron beam (고에너지 전자선 측정을 위한 광섬유 방사선 센서에서의 체렌코프 빛 측정 및 분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Jeong, Sun-Cheol;Jun, Jae-Hun;Lee, Bong-Soo;Kim, Sin;Cho, Hyo-Sung;Park, Sung-Yong;Shin, Dong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.186-191
    • /
    • 2006
  • In general, Cerenkov light is produced by a charged particle that passes through a medium with a velocity greater than that of visible light. Although the wavelength of Cerenkov light is very broad, the peak is in the almost visible range from 400 to 480 nm. Therefore, it always causes a problem to detect a real light signal that is generated in the scintillator on the fiber-optic sensor tip for dose measurements of high-energy electron beam. The objectives of this study are to measure, characterize and remove Cerenkov light generated in a fiber-optic radiation sensor tip to detect a real light signal from the scintillator. In this study, the intensity of Cerenkov light is measured and characterized as a function of incident angle of electron beam from a LINAC, and as a function of the energy of electron beam. As a measuring device, a photodiode-amplifier system is used, and a subtraction method using a background optical fiber is investigated to remove Cerenkov light.

Measurement of Energy Dependent Neutron Capture Cross Sections of $^{197}Au$ in Energy Region from 0.1 eV to 10 keV using a Lead Slowing-down Spectrometer

  • Yoon, Jung-Ran
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.29-32
    • /
    • 2010
  • The neutron capture cross section of $^{197}Au$ has been measured relative to the $^{10}B(n,{\gamma})$ standard cross section by the neutron time-of-flight(TOF) method using a 46-MeV electron linear accelerator(linac) at the Research Reactor Institute, Kyoto University(KURRI). In order to experimentally prove the result obtained, the supplementary cross section measurement has been made from 0.1 eV to 10 keV using the Kyoto University Lead slowing-down spectrometer (KULS) coupling to the linac. The relative measurement by the TOF method has been normalized to the reference value(24.5 b) at 1 eV. The evaluated capture cross sections in JENDL/D-99 Dosimetry have been compared with the current measurements by the KULS experiments.

Radioprotective Effects of Blueberry on the Liver of Radiation Irradiated Rats (방사선에 조사된 쥐 간에서 블루베리의 방사선방호효과)

  • Jang, Suin;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.239-244
    • /
    • 2013
  • Radiation were seriously damaged on liver functions. Blueberry was fruits that contains Vit A, Vit c, Vit E, follic acid, ${\beta}$-carotene, and anthocyanin. The purpose of this study was to evaluate the protection effects of blueberry the liver functions. Irradiation dose was used to 4 Gy (Linac 6 Mev) X-ray Treatment device Experiment animals was used to 7 rats in each groups. It was investigated liver functions that contains TP, ALB, GLOB, ALT, ALKP and CHOL. We showed that Blueberry was not recovery effects on radiation-induced liver functions. But, Statistically significant value was showed ALB (p>0.01) and ALT (p>0.1). It was concluded that blueberry was not used to recovery materials on radiation-induced liver functions.

Analysis of Radioactive Characterization in the Medical Linear Accelerator Shielding Wall Using Monte Carlo Method (몬테칼로법을 이용한 의료용 선형가속기 차폐벽의 방사화 특성 분석)

  • Lee, Dong-Yeon;Park, Eun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.758-765
    • /
    • 2016
  • This study analyzed for the radioactive shielding wall, which shields the medical linear accelerator. This allows to evaluate the level of waste with respect to the shield wall, which accounts for more than half of the cost of dismantling later linac facility. In addition, by analyzing the waste processing method according we discuss the way to obtain the benefits in terms of dismantling cost. Results of the simulate, the amount sufficient to screen the amount of neutron radiation occurring in the shielding wall linac was measured. And neutron activation analysis results were analyzed nuclides more than about 20. This analysis was in excess of that, $^{24}Na$, $^{45}Ca$, $^{59}Fe$ nucleus paper deregulation concentration. The value is reduced is greater the deeper the depth of the shielding wall concentration. Based on this, three specific areas (E, F, G) was estimated to be impossible to landfill or recycling. The rest area was estimated to be buried or recycled if possible more than a predetermined depth.

Calculation of Energy Spectra for Electron Beam of Medical Linear Accelerator Using GEANT4 (GEANT4를 이용한 선형가속기 기초 코드 작성과 전자선 에너지 분포 계산)

  • Joh, Young-Gull;Kim, Hyung-Dong;Kim, Byung-Young;Kim, Sung-Jin;Oh, Se-An;Kang, Jeong-Ku;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.85-91
    • /
    • 2011
  • The energy spectra for electron beam of medical linear accelerator were calculated using a GEANT4 Medical Linac 2 example code. The incident electron mean energy were 6, 9, 12, 16, 20 MeV. This code was designed to calculate electron beam energy spectra according to material, thickness and location of electron scattering foil affecting electron beam characteristic. Lead, Copper, Aluminum and Gold were used for scattering foil. The energy distribution for electron and photon were analyzed by changing position of scattering foil in the head of linear accelerator. The effect of electron scattering foil on energy spectra which is basic data of simulation for medical linear accelerator were presented. The calculated results would be used in design of medical accelerator head.

Segmental Analysis Trial of Volumetric Modulated Arc Therapy for Quality Assurance of Linear Accelerator

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Huh, Hyun Do;Kim, Seonghoon
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.128-138
    • /
    • 2019
  • Purpose: Segmental analysis of volumetric modulated arc therapy (VMAT) is not clinically used for compositional error source evaluation. Instead, dose verification is routinely used for plan-specific quality assurance (QA). While this approach identifies the resultant error, it does not specify which machine parameter was responsible for the error. In this research study, we adopted an approach for the segmental analysis of VMAT as a part of machine QA of linear accelerator (LINAC). Methods: Two portal dose QA plans were generated for VMAT QA: a) for full arc and b) for the arc, which was segmented in 12 subsegments. We investigated the multileaf collimator (MLC) position and dosimetric accuracy in the full and segmented arc delivery schemes. A MATLAB program was used to calculate the MLC position error from the data in the dynalog file. The Gamma passing rate (GPR) and the measured to planned dose difference (DD) in each pixel of the electronic portal imaging device was the measurement for dosimetric accuracy. The eclipse treatment planning system and a MATLAB program were used to calculate the dosimetric accuracy. Results: The maximum root-mean-square error of the MLC positions were <1 mm. The GPR was within the range of 98%-99.7% and was similar in both types of VMAT delivery. In general, the DD was <5 calibration units in both full arcs. A similar DD distribution was found for continuous arc and segmented arcs sums. Exceedingly high DD were not observed in any of the arc segment delivery schemes. The LINAC performance was acceptable regarding the execution of the VMAT QA plan. Conclusions: The segmental analysis proposed in this study is expected to be useful for the prediction of the delivery of the VMAT in relation to the gantry angle. We thus recommend the use of segmental analysis of VMAT as part of the regular QA.