• Title/Summary/Keyword: limits of stability

Search Result 353, Processing Time 0.03 seconds

Structure and Characteristics of Diffusion Flame behind a Bluff-Body in a Divergent Flow(I) (확대유로내의 Bluff-Body 후류확산화염의 구조 및 특성 (1))

  • 최병륜;이중성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1269-1279
    • /
    • 1995
  • An experimental study is carried out on turbulent diffusion flames stabilized by a circular cylinder in a divergent duct flow. A commercial grade gaseous propane is injected from two slits on the rod as fuel. Flame stability limits, as well as size and temperrature of recirculation zone, are measured by direct and schlieren photographs to clarify the characteristics and structure of diffusion flames and to assess the effect of various divergent angle of duct. The results of the present study are as follows. Temperature in the recirculation zone decreases with increasing divergent angle. The blow-off velocity in parallel duct is higher than that in divergent duct. Critical blow-off velocity is expected to be about 8-12 degree through blow-off velocity pattern. Regardless of divergent angles, the length of recirculation zone is nearly constant, and this length becomes longer with rod diameter. Pressure gradient has an effect on the eddy structure in shear layer behind the rod. With the increase of divergent angle, large scale eddies by dissipated energy in shear layer are split into small scale eddies, and the flame becomes a typical distributedreacting flame.

Surface Functionalization of Carbon Fiber for High-Performance Fibrous Supercapacitor (고성능 섬유형 슈퍼커패시터를 위한 탄소섬유의 표면 기능화)

  • Lee, Young-Geun;An, Geon-Hyoung
    • Korean Journal of Materials Research
    • /
    • v.32 no.2
    • /
    • pp.107-113
    • /
    • 2022
  • Fibrous supercapacitors (FSs), owing to their high power density, good safety characteristic, and high flexibility, have recently been in the spotlight as energy storage devices for wearable electronics. However, despite these advantages, FCs face many challenges related to their active material of carbon fiber (CF). CF has low surface area and poor wettability between electrode and electrolyte, which result in low capacitance and poor long-term stability at high current densities. To overcome these limits, fibrous supercapacitors made using surface-activated CF (FS-SACF) are here suggested; these materials have improved specific surface area and better wettability, obtained by introducing porous structure and oxygen-containing functional groups on the CF surface, respectively, through surface engineering. The FS-SACF shows an improved ion diffusion coefficient and better electrochemical performance, including high specific capacity of 223.6 mF cm-2 at current density of 10 ㎂ cm-2, high-rate performance of 171.2 mF cm-2 at current density of 50.0 ㎂ cm-2, and remarkable, ultrafast cycling stability (96.2 % after 1,000 cycles at current density of 250.0 ㎂ cm-2). The excellent electrochemical performance is definitely due to the effects of surface functionalization on CF, leading to improved specific surface area and superior ion diffusion capability.

Collocation of Sensor and Actuator for Active Control of Sound and Vibration (능동음향진동제어를 위한 센서와 액추에이터의 동위치화 연구)

  • 이영섭
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.3
    • /
    • pp.253-263
    • /
    • 2004
  • The problem considered in this paper is about the collocation of sensor and actuator for the active control of sound and vibration. It is well-known that a point collocated sensor-actuator pair offers an unconditional stability with very high performance when it is used with a direct velocity feedback (DVFB) control, because the pair has strictly positive real (SPR) property. In order to utilize this SPR characteristics, a matched piezoelectric sensor and actuator pair is considered. but this pair suffers from the in-plane motion coupling problem with the out-of-plane motion due to the piezo sensor and actuator interaction. This coupling phnomenon limits the stability and performance of the matched pair with DVFBcontrol. As a new alternative, a point sensor and distributed piezoelectric actuator pair is also considered, which provides SPR property in all frequency range when the pair is implemented on a clamped-clapmed beam. The use of this sensor-actuator pair is highly expected for the applications to more practical active control of sound and vibration systems with the DVFB control strategy.

Dynamic Characteristics Analysis and Chatter Prediction in High Speed CNC Lathe (고속 CNC 선반의 동특성 해석과 채터 예측)

  • Lee, Woo-Seok;Lee, Sin-Young;Lee, Jang-Moo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.151-157
    • /
    • 1999
  • Vibrations in machine tools make many problems in precision, production efficiency, and machine performance. The relative vibration between a workpiece and a tool is very complicated due to many sources. In this study, the dynamic characteristics of a newly developed CNC lathe were analyzed and its chatter characteristics were predicted by a chatter analysis method using finite element analysis and 3 dimensional cutting dynamics. The simulated results showed very complex characteristics of chatter vibration and the borderline of limiting depth of cut was used as the stability limit. To check the validity of this method, cutting tests were done in the CNC lathe using a boring bar as a tool because boring process is very weak due to long overhang . The experimental results showed that the simplified borderline was to be considered as limiting depth of cut at which the chatter vibration starts and the stability limits depended on various cutting parameters such as cutting speed, feed and nose radius of tool.

  • PDF

Sampling and Analytical Method for Linear Carbonates using GC/FID (GC/FID를 이용한 사슬형 카보네이트 3종의 측정·분석방법)

  • Miyeon Jang;Gwangyong Yi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.455-463
    • /
    • 2023
  • Objectives: The aim of this study was to develop an air sampling and analytical method for estimating worker exposure to linear carbonate solvents and to evaluate the method. Methods: The target substances were three linear carbonates: DMC, DEC, EMC. GC/FID was used for sample analysis. Laboratory experiments were conducted to determine desorption solvents and sample capacity, and to evaluate storage stability, accuracy, and precision. Results: Coconut Shell Charcoal (CSC, 100/50 mg) was used as the air sampling media, and a desorption solvent of 5% methanol/95% dichloromethane was selected. Recommended sampling capacities were 1~11 ℓ for DMC, 1~18 ℓ for DEC, and 1~24 ℓ for EMC. The stability of three linear carbonates was demonstrated over 30 days in a refrigerator (4℃). Detection limits were determined as follows: DMC 0.26 ㎍/sample, DEC 0.24 ㎍/sample, and EMC 0.25 ㎍/sample. The total coefficient of variation was calculated as DMC 0.064, DEC 0.079, and EMC 0.07. Conclusions: This sampling and analysis method is suitable for estimating personal exposure to linear carbonates in the workplace.

Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study

  • Lee, Jungwon;Pyo, Se-Wook;Cho, Hyun-Jae;An, Jung-Sub;Lee, Jae-Hyun;Koo, Ki-Tae;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.1
    • /
    • pp.56-66
    • /
    • 2020
  • Purpose: A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods: Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. Results: The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Conclusions: Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.

Structural Performance of 800 MPa High-Strength Steel Members and Application to Highrise and Mega Building Structures

  • Lee, Cheol-Ho
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.249-259
    • /
    • 2017
  • The use of high-strength steels in construction of highrise and mega building structures can bring about many technological advantages from fabrication to erection. However, key design criteria such as local and lateral stability in current steel design specifications were developed based on tests of ordinary steels which have stress-strain characteristics very different from that of high strength steels. A series of tests on 800 MPa tensile strength steel (HSA800) members are summarized in this paper which were conducted to investigate the appropriateness of extrapolating current ordinary-steel based design criteria to high strength steels. 800 MPa I-shape beam specimens designed according to flange local buckling (FLB) criteria of the AISC Specification developed a sufficient strength for elastic design and a marginal rotation capacity for plastic design. It is shown that, without introducing distinct and significant yield plateau to the stress-strain property of high-strength steel, it is inherently difficult to achieve a high rotation capacity even if all the current stability limits are met. 800 MPa I-shape beam specimens with both low and high warping rigidity exhibited sufficient lateral torsional buckling (LTB) strength. HSA800 short-column specimens with various edge restraint exhibited sufficient local buckling strength under uniform compression and generally outperformed ordinary steel specimens. The experimental P-M strength was much higher than the AISC nominal P-M strength. The measured residual stresses indicated that the impact of residual stress on inelastic buckling of high-strength steel is less. Cyclic seismic test results showed that HSA800 members have the potential to be used as non-ductile members or members with limited ductility demand in seismic load resisting systems. Finally, recent applications of 800 MPa high strength steel to highrise and mega building structures in Korea are briefly presented.

Facilitated ion transport through cellulose triacetate-based polymer inclusion membranes: A promising method for treatment of nuclear wastewater

  • Samuel P.Kusumocahyo;Toshiyuki Kanamori;Kim, io-Sumaru;Toshio Shinbo;Hideto Matsuyama;Masaaki Teramoto
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.43-46
    • /
    • 2004
  • The large quantity of liquid wastes from nuclear industries such as nuclear power plants would become a serious storage problem in view point of the environmental safety. The liquid wastes should be concentrated to a smallest possible volume before the storage. The use of supported liquid membranes (SLMs) for this purpose is very attractive [1,2], however loss of solvent and carrier in the surrounding solutions limits the stability of SLMs and hinders their commercial application in the industries.(omitted)

  • PDF

Effect on Body Balance due to mouth guard (마우스 가드가 신체 균형에 미치는 영향)

  • Won, Hyeon-Jin;Kim, Chi-Young;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.37 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose: This study, it was observed on the effect of material and thickness of the mouth guard on postural balance in order to assess the influence of the use of a mouth guard. Methods: The mouth guards of 10 adults selected as the experiment subject was sorted into each of hard and soft material, and these were made as thickness of 2.0 mm, 2.5 mm, 3.0 mm, 3.5 mm by each of the material. Results: The results of this study are expected to wear the mouthguard hard to influence positive influence on the improvement of the muscle strength, static balance. Conclusion: Suggest the need for additional research on dynamic balance.

Use of Bovine-derived bone mineral (Bio-Oss Collagen$^{(R)}$) in surgical treatment of peri-implantitis: A case report (임상가를 위한 특집 3 - Peri-implantitis의 regeneration therapy 증례 보고)

  • Cho, Young Jae
    • The Journal of the Korean dental association
    • /
    • v.51 no.12
    • /
    • pp.643-649
    • /
    • 2013
  • The aim of this study was to achieve the healing of peri-implantitis defects and the hard tissue regeneration using the augmentation of a xenograft on defect site. Two patients were treated with the surgical approach. With a full muco-periosteal flap elevation, the implant surfaces were exposed and taken the debridement of granulation tissue around the abutment. Each surface of the abutments was prepared with the air-abrasive device (PerioFlow$^{(R)}$) for decontamination. Bovine-derived bone mineral (Bio-Oss collagen$^{(R)}$) was then used to fill the defects, and no membrane was placed on the grafting site. Radiographs and clinical photo was taken to compare from baseline status. Within the limits of the present case, this case shows the significance of the surgical treatment of peri-implantitis. And this also verifies the stability of bovine-derived bone mineral and effectiveness of Air-abrasive device (PerioFlow$^{(R)}$).