• 제목/요약/키워드: limiting temperature

검색결과 411건 처리시간 0.031초

Determination of limiting temperatures for H-section and hollow section columns

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • 제13권4호
    • /
    • pp.309-325
    • /
    • 2012
  • The risk of progressive collapse in steel framed buildings under fire conditions is gradually rising due to the increasing use of combustible materials. The fire resistance of such steel framed buildings is evaluated by fire tests. Recently, the application of performance based fire engineering makes it easier to evaluate the fire resistance owing to various engineering techniques and fire science. The fire resistance of steel structural members can be evaluated by the comparison of the limiting temperatures and maximum temperatures of structural steel members. The limiting temperature is derived at the moment that the failure of structural member results from the rise in temperature and the maximum temperature is calculated by using a heat transfer analysis. To obtain the limiting temperatures for structural steel of grades SS400 and SM490 in Korea, tensile strength tests of coupons at high temperature were conducted. The limiting temperatures obtained by the tensile coupon tests were compared with the limiting temperatures reported in the literature and the results of column fire tests under four types of loading with different load ratios. Simple limiting temperature formulas for SS400 and SM490 steel based on the fire tests of the tensile coupons are proposed. The limiting temperature predictions using the proposed formulas were proven to be conservative in comparison with those obtained from H-section and hollow section column fire tests.

각형 강관기둥부재의 한계온도 평가 연구 (Evaluation of Limiting Temperatures of Rectangular Hollow Sections)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.331-332
    • /
    • 2012
  • Structural steel has been used as a primary materials to columns and beams since 1960's in Korea with an advantages of excellent of load-bearing capacity and design flexibility, and faster construction. However, if the steel columns made of structural steel exposed to fire the load-bearing capacity is going down steadily and finally reach to collapse. Therefore, building regulation requires fire resistance according to building occupation, scales. The fire resistance can be evaluated two categories. One is prescriptive method that is based on building regulation, specification and so on and the other is performance-based fire engineering method. The latter can be designed based on scientific and engineering consequences. The easiest evaluation way using the fire engineering design is comparing to the limiting temperature and maximum temperature calculated based on heat transfer theory. If the limiting temperature of a column exceeds the maximum temperature of it, the column can carry the load during the fire. Therefore, the database of limiting temperature is very essential for evaluation of column. In this paper, to build the database of column made of rectangular hollow sections 8 fire tests with loading were conducted and the relation between the limiting temperature and the applied loads showed in reverse proportion.

  • PDF

개구리밥과 식물의 질소대사에 관한 연구 (A Study of Nitrogen Metabolism in Lemnaceae -Limiting Factors of Distribution of Spirodela Polyrhiza and Lemna aequinoctialis-)

  • Chang, Nam-Kee;Oh, In-Hye;Kim, Heui-Baik;Yoo, Hae-Mee;Eo, Eun-Joo
    • The Korean Journal of Ecology
    • /
    • 제13권3호
    • /
    • pp.215-224
    • /
    • 1990
  • The distribution of Spirodela polyrhiza and Lemna aequinoctialis was investigated and the limiting factors on the distribution were analyzed. At 66 sites in Korea, the presense or absense of duckweed were recorded and the water was sampled. The temperature, hardness, pH and contents of N, , , Na, K, Ca, Cu, Mg, Zn, Fe, Ni, Mn and Cd of water sampled were analyzed. The results were as follows; It seemed that the limiting factors influencing on the distribution was water temperature and concentration of . The critical temperature of the distribution of Spirodela and Lemna was presented 19.5$^{\circ}C$ and concentration of was limiting factor only in the distribution of S. polyrhiza. L. aequinoctialis was distributed in lower temperature than S. polyrhiza and it seemed that the distribution of L. aequinoctialis was not be influenced by the concentration of .

  • PDF

190 kVA급 초전도한류소자의 특성 (Characteristics of a 190 kVA Superconducting Fault current Limiting Element)

  • 마용호;이주영;박권배;오일성;류경우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.37-42
    • /
    • 2007
  • We are developing a 22.9 kV/25 MVA superconducting fault current limiting(SFCL) system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric field during fault of the power network, was selected as a candidate for our SFCL system. In this work, we experimentally investigated important characteristics of the 190 kVA Bi-2212 SFCL element in its application to the power grid e.g. DC voltage-current characteristic, AC loss, current limiting characteristic during fault, and so on. Some experimental data related to thermal and electromagnetic behaviors were also compared with the calculated ones based on numerical method. The results show that the total AC loss at rated current of the 22.9 kV/25 MVA SFCL system, consisting of one hundred thirty five 190 kVA SFCL elements, becomes likely 763 W, which is excessively large for commercialization. Numerically calculated temperature of the SFCL element in some sections is in good agreement with the measured one during fault. Local temperature distribution in the190 kVA SFCL element is greatly influenced by non-uniform critical current along the Bi-2212 bulk SFCL element, even if its non-uniformity becomes a few percentages.

고정생물막 공법을 이용한 질소제거에 있어서 제한요인에 관한 연구 (A Study on the Limiting Factors in Nitrogen Removal with Fixed Biofilm Process)

  • 지용희
    • 환경위생공학
    • /
    • 제11권3호
    • /
    • pp.63-68
    • /
    • 1996
  • This study was to discuss limiting factors influenced on the removal efficiencies of nitrogenous compounds investigated using the polypropyrene media which was to attach microorganism in order to apply the fixed-biofilm process. The main limiting factors are the hydraulic retention time (HRT), C/N ratio, $COD/NO_{3}-N$ ratio and temperature. The hydraulic retention time HRT were 6, 8, 10, 12 hrs and the C/N ratio range was 2.5-9.5. The $COD/NO_{3}-N$ ratio range was 3.2-21.9 and the temperature were 15, 20, 25, 30, $35^{\circ}C$, respectively. The results of this study are summerized as follows. 1. Hydraulic retention time (HRT) to obtain removal efficiencies of T-N higher than 85% had to be 10 hrs above. 2. The removal efficiencies of T-N decreased at C/N ratio from 6.2 to 4.8 in this anoxic-contact aeration system. 3. Denitrification rate decreased at $COD/NO$_{3}$-N$ ratio from 8.0 to 5.0 4. As temperature increased, removal efficiencies of T-N increased.

  • PDF

Hydroxy Propyl Methyl Cellulose 분진의 운상자연발화에 관한 연구 (A Study on The Spontaneous Ignition of a Hydroxy Propyl Methyl Cellulose Dust Cloud)

  • 임우섭;목연수
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.137-140
    • /
    • 2004
  • 최근 산업현장에서는 제품의 품질과 성능을 향상시키기 위해 나노 기술로 나아가는 추세에 있으며, 이러한 연구들로 인해 많은 화학제품의 원료들이 더욱 미세한 상태로 가공 및 취급되어지고 있다. 이에 분진의 특성상 그 위험성이 따라 증가하고 있으므로, 분진폭발의 발생을 예방하기 위해 분진운의 발화온도와 폭발한계산소농도 등을 찾아내는 것은 매우 중요한 일이다. 따라서 본 연구에서는 현재 국내에서 생산되고 있는 Hydroxy Propyl Methyl Cellulose (HPMC)을 가지고 실험을 하였으며, 생산 및 취급과정에서 뜨거운 표면으로부터 발생될 수 있는 화재 및 폭발을 예방하고자, Godbert-Greenwald Furnace장치로 실험하였다. 그 결과 분진 입자의 크기가 작아짐으로서 발화온도는 낮아지는 경향을 나타내었으며, 분진입자의 크기가 45${\mu}m$에서 HPMC 분진운의 최소발화온도는 364$^{\circ}C$로 나타났으며, 폭발한계산소 농도는 11%로 나타났다.

Plastification procedure of laterally-loaded steel bars under a rising temperature

  • Huang, Zhan-Fei;Tan, Kang-Hai;England, George L.
    • Structural Engineering and Mechanics
    • /
    • 제35권6호
    • /
    • pp.699-715
    • /
    • 2010
  • This paper investigates the structural responses of axially restrained steel beams under fire conditions by a nonlinear finite element method. The axial restraint is represented by a linear elastic spring. Different parameters which include beam slenderness ratio, external load level and axial restraint ratio are investigated. The process of forming a mid-span plastic hinge at the mid-span under a rising temperature is studied. In line with forming a fully plastic hinge at mid-span, the response of a restrained beam under rising temperature can be divided into three stages, viz. no plastic hinge, hinge forming and rotating, and catenary action stage. During catenary action stage, the axial restraint pulls the heated beam and prevents it from failing. This study introduces definitions of beam limiting temperature $T_{lim}$, catenary temperature $T_{ctn}$ and warning time $t_{wn}$. Influences of slenderness ratio, load level and axial restraint ratio on $T_{lim}$, $T_{ctn}$ and $t_{wn}$ are examined.

Moment curvature method for fire safety design of steel beams

  • Yu, H.X.;Richard Liew, J.Y.
    • Steel and Composite Structures
    • /
    • 제4권3호
    • /
    • pp.227-246
    • /
    • 2004
  • This paper presents a moment-curvature method that accounts for the strength deterioration of steel at elevated temperature in estimating the response of steel beams exposed to fire. A modification to the EC4 method is proposed for a better estimation of the temperature distribution in the steel beam supporting a concrete slab. The accuracy of the proposed method is verified by comparing the results with established test results and the nonlinear finite element analysis results. The beam failure criterion based on a maximum strain of 0.02 is proposed to assess the limiting temperature as compared to the traditional criteria that rely on deflection limit or deflection rate. Extensive studies carried out on steel beams with various span lengths, load ratios, beam sizes and loading types show that the proposed failure criterion gives consistent results when compared to nonlinear finite element results.

청과물 저온저장고의 설계에 관한 연구 (1) -자연환기를 이용한 제주산밀감저장고의 설계- (On the Design of Cold Storage for Fruits and Vegetables (1) -Design of Natural Ventilating Type Store for Citrus Furits in Jejudo-)

  • 허종화;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제5권4호
    • /
    • pp.272-280
    • /
    • 1976
  • A natural ventilating type store was designed for the economic and effective storage of citrus fruits in Jejudo. The material used for the wall is scoria, widely distributed in Jejudo and known for high strength and insulation. Design condition was chosen for the period till March of a year and the dry bulb temperature was taken from TAC $5\%$ base. The temperature of the store can be maintained below the limiting temperature of $8^{\circ}C$ for the time length of $7\frac{1}{2}$ hours under the condition of the atmospheric temp, $15.3^{\circ}C$ and the solar insolation. The limiting temperature can he recovered to the initial temperature $(7^{\circ}C)$ by the natural ventilation for 8 hours in the night.

  • PDF

다중벽 탄소 나노튜브 현탁액의 광 리미팅 특성 (Optical Limiting Properties of Multi-Walled Carbon Nanotube Suspensions)

  • 유효정;김석원
    • 한국광학회지
    • /
    • 제15권5호
    • /
    • pp.449-454
    • /
    • 2004
  • 광 리미터는 입사광의 세기가 커질때 투과율을 줄여서 눈과 센서를 보호하는 광소자이다. 최근에 높은 효율의 광 리미터 재료로 알려진 다중벽 탄소 나노튜브 분말을 증류수, 클로로포름, 에탄올, 에틸렌 글리콜과 같은 용매에 각각 섞어 현탁액을 만들고 실온에서 용매의 끓는점까지 온도를 변화시키면서 광 리미팅 효율의 변화를 관측하였다. 광원으로는 펄스폭이 6 ns이고 파장이 1064 nm인 Q-스위칭된 Nd:YAG 레이저 펄스를 사용하였다. 관측 결과, 다중벽 탄소 나노튜브 현탁액의 온도가 증가할수록 광 리미팅 효율이 나빠졌고 현탁액 용매의 끓는점, 점도 그리고 표면장력 값이 낮을수록 광 리미팅 효율이 좋아짐을 확인하였다.