• Title/Summary/Keyword: limitation

Search Result 8,420, Processing Time 0.037 seconds

A Non-volatile Memory Lifetime Extension Scheme Based on the AUTOSAR Platform using Complex Device Driver (AUTOSAR 플랫폼 기반 CDD를 활용한 비휘발성 메모리 수명 연장 기법)

  • Shin, Ju-Seok;Son, Jeong-Ho;Lee, Eun-Ryung;Oh, Se-Jin;Ahn, Kwang-Seon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.5
    • /
    • pp.235-242
    • /
    • 2013
  • Recently, the number of automotive electrical and electronic system has been increased because the requirements for the convenience and safety of the drivers and passengers are raised. In most cases, the data for controlling the various sensors and automotive electrical and electronic system used in runtime should be stored on the internal or external non-volatile memory of the ECU(Electronic Control Units). However, the non-volatile memory has a constraint with write limitation due to the hardware characteristics. The limitation causes fatal accidents or unexpected results if the non-volatile memory is not managed. In this paper, we propose a management scheme for using non-volatile memory to prolong the writing times based on AUTOSAR(AUTOmotive Open System Architecture) platform. Our proposal is implemented on the CDD(Complex Device Driver) and uses an algorithm which swaps a frequently modified block for a least modified block. Through the development of the prototype, the proposed scheme extends the lifetime of non-volatile memory about 1.08 to 2.48 times than simply using the AUTOSAR standard.

Changes in Student Nurses' Perception between Initial and Final Clinical Practice (임상실습 초기와 종료 후의 임상실습에 대안 간호학생의 인식 변화)

  • Kim Myung-Ae;Nam Seung-Hee;Kim Hyo-Eun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.11 no.1
    • /
    • pp.21-30
    • /
    • 2004
  • Purpose: The purpose of this study was to explore perception of clinical experience between the initial and final practice and to explore changes in the perception of clinical experience. Method: The study used a Q-method to measure perception of clinical practice. Thirty-six statements made up the finalized Q-sample. The P sample used thirty three nursing college students from K university. The initial collection was done in the first semester of their junior year and second collection was done in the last semester of their senior year. The Q-sorts by each student were coded and analysed with the Quanl PC program. Result: Many students classified as having the perception type 'alienation of ideal and reality' or 'perception of limitation of ability' in the initial clinical practice changed to the type, 'active participation' by the final clinical practice. Further, in the initial clinical practice, part of 'active participation' and 'perception of limitation of ability' changed to 'alienation of ideal and reality'. Conclusion: This study shows that perception of their clinical practice by student nurses changed in a positive direction through clinical experience and that this fact was related to the level of satisfaction with nursing. The knowledge and understanding obtained in this research provide insights for nursing faculty and students involved in nursing education.

  • PDF

The effect of non-surgical treatment in gingival enlargement (치은비대에서 비외과적 치료의 효과)

  • Kim, Sang-Jun;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.1
    • /
    • pp.103-108
    • /
    • 2009
  • Purpose: It is well recognized that gingival enlargement is induced by unwanted effect associated with three major drugs/drug groups - phenytoin, cyclosporine, and the calcium channel blockers. The present case report describes the effect and limitation of non-surgical treatment in gingival enlargement cases. Materials and methods: Three cases included 2 drug-influenced gingival enlargement patients and a idiopathic gingival fibromatosis patient. For the drug-influenced gingival enlargement patients, the medication was replaced with other medication. And then, all the patients were treated non-surgically. Results: Drug-influenced gingival enlargements had been reduced after non-surgical treatment and the results were well-maintained. In the idiopathic gingival fibromatosis case, non-surgical treatment resulted in only limited reduction of gingival enlargement, and surgical periodontal treatment was unavoidable. Conclusion: These case reports indicated that non-surgical periodontal treatment with change in medication was effective in the treatment of drug-influenced gingival enlargements. Non-surgical approach can be considered as the primary management to reduce the gingival enlargement. If non-surgical treatment encounters a limitation, surgical treatment should be considered.

Preschool Children Mother's Child Rearing Attitude Using Korean Parent as a Teacher Test (학령전기 아동 어머니의 양육태도)

  • Kim, Shin-Jeong;Kim, Kae-Sook;Kim, Young-Hee
    • Korean Parent-Child Health Journal
    • /
    • v.10 no.1
    • /
    • pp.3-12
    • /
    • 2007
  • Purpose: The purpose of this study was to test a KPAAT(Korean Parent As a Teacher Test) and provide a basic data to develop parent education program. Methods: This is a secondary analysis study using 103 preschool mothers who were chosen from 2 kindergarten and child care center located at Kyounki-Do. Results: 1) Subjects' child-rearing attitude was above average at the point of $2.86({\pm}\;.20)$. 2) 16 sub-dimension(response to question, permissive attitude of play, control, control of play, expectation about child, understanding about learning, support of learning, encouragement of thinking, provision of imaginary play opportunities, support of play, encouragement of accomplishment motivation, propriety of child-rearing, affectional support, fixed idea, confidence about education, limitation) and 6 factors(response to question, permission of play, control & limitation, evaluation & support about child, encouragement of academic accomplishment, facilitation of the development of creativity) were above 2.50 except ($2.24{\pm}\;.29$) sub-dimension. 3) There was no significant difference statistically according to subjects' general characteristics. Conclusion: From this study, KPAAT can be utilized later childhood period. And nurses need to help mothers to have sound child rearing attitude.

  • PDF

AN EXPERIMENTAL STUDY ON AIR-WATER COUNTERCURRENT FLOW LIMITATION IN THE UPPER PLENUM WITH A MULTI-HOLE PLATE

  • NO HEE CHEON;LEE KYUNG-WON;SONG CHUL-HWA
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.557-564
    • /
    • 2005
  • Air-water countercurrent flow limitation at perforated plates with four holes was investigated in a vertical tank to see the effects of the plate thickness, the number of hole, and the diameter of the hole on the onset of CCFL. The thickness of plates was 1 cm and 4 cm, with a relatively large hole diameter of 5 cm. The collapsed water level formed on the perforated plate and its distribution in the upper plenum were measured. The gas flow rate in the multi-hole plate is relatively higher than one in the single tube because some of holes in the multi-hole plate provide a flow path fur liquid with less air-liquid resistance than in the single tube. The onset of CCFL occurred at nearly the same air flow rate regardless of the plate thickness. The negligible effect of the plate thickness on CCFL means that the flooding is initiated at the top of the plate rather than at its bottom. It turns out that $j_k$ and $K_k$ better fit the data than $H_k$ when hole diameter is greater than 2.86 cm. In our experimental ranges, the collapsed water levels at the onset of CCFL ranged from 7.5 cm to 10.5 cm. There was no three dimensional distribution of water level before and after the onset of CCFL.

A Study on Application of a Heat Pipe to an Evacuated Glass Tube Solar Collector (진공 유리관 태양열 집열기에 열파이프의 적용을 위한 기초 연구)

  • Kim, Chul-Joo
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.9-17
    • /
    • 1992
  • This is an experimental work concerning about an application of a heat pipe to an evacuated-glass-tube solar collector system. A methanol heat pipe with length of 0.7 m and diameter of 8 mm was manufactured and tested to compare its performance with that of freon thermosyphon which was originally used in a solar collector system fabricated at Thermomax Co.. Then this methanol heat pipe was utilized to be one component, i.e. heat transfer element, of the present experimental model of a solar collector. This model was performed the operation test as its absorber plate was irradiated by infrared lamps. The following results were obtained. (1) The methanol heat pipe was showed a stable operation when the variation of axial heat transport was $0{\sim}40$ watts and that of inclination angle was $30{\sim}90^{\circ}$. (2) The heat transport capability of the heat pipe was proved to be higher than that of the thermosyphon, because the heat transport limitation of the latter was occured at about 30 watt. (3) The heat pipe in a solar collector was also showed good performance as it transmitted absorbed energy.

  • PDF

Influencing Factors and Trend of Suicidal Ideation in the Elderly: Using the Korea National Health and Nutrition Examination Survey(2001, 2005, 2010) (노년기 자살생각의 요인과 변화추이 분석: 국민건강영양조사 3개년도(2001, 2005, 2010)자료를 활용하여)

  • Choi, Ryoung;Hwang, Byung-Deog
    • Korean Journal of Health Education and Promotion
    • /
    • v.31 no.5
    • /
    • pp.45-58
    • /
    • 2014
  • Objective: The purpose of this study was to analysis the determinants and trend of suicidal ideation the elderly in Korea. Methods: This study participants were selected the elderly over the age of 55 from the Korea National Health and Nutrition Examination Survey in 2001(n=1,122), 2005(n=2,098), and 2010(n=2,402). Statistical analysis methods used in this study were $x^2$-test, logistic regression analysis and other basic statistics such frequency, percentage using SPSS version 21.0. Results: In 2001, the influencing factors of suicidal ideation was spouses, subjective health status and stress recognition. In 2005, the influencing factors of suicidal ideation were spouses, subjective health status, chronic disease amount, activity limitation, depression experience and stress recognition. In 2010, the influencing factors of suicidal ideation were elderly, education level, subjective health status, activity limitation, depression experience and stress recognition. Conclusions: The health education considering the characteristics of each elderly group should be developed and applied to prevent adults' suicidal ideation because the factors influencing suicidal ideation were revealed differently between the elderly group.

A Study ort the Facilities Distribution based on the Choice Model of the Outdoor Leisure-Facilities in a Neighbourhood Unit of the Megalopolis Citizens. - in terms of the distribution of Outdoer Leisure-Facilities - (대도시 주민의 근린 실외여가시설 선택모형을 기초로 한 시설지 배분에 관한 연구)

  • 최기수;김한배;진양교;진상철;김석기
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.23 no.1
    • /
    • pp.141-156
    • /
    • 1995
  • This research is executed to find out the boundary of use by the conscious of local residents and to get the basic materials for the distribution of outdoor leisure-facilities. The map of use distribution of the outdoor leisure-facilities in a neighbourhood unit is made by applying a concept of the probabilistic contour line based on the choice model of outdoer leisure-facilities in the city of Seoul, Taegu an\ulcorner Kwangju. The results are listed as follows. 1) The use of outdoor leisure-facilities is influenced on the accessibility by the physical obstacles of streets and hills, etc. 2) The limitation of uses applying the model of choice probability are different according to the accessibility, the percentage of utilities and the arriving range based on the questionnaires which are surveyed the choice of outdoor leisure facilities of the residents of Seoul, Taegu and Kwangju. 3) The distribution of outdoor leisure facilities is decided by the limitation of use with the conscious of local residents.

  • PDF

2.5MHz Zero-Voltage-Switching Resonant Inverter for Electrodeless Fluorescent Lamp (2.5MHz급 무전극 램프 구동용 ZVS 인버터에 관한 연구)

  • Park, D.H.;Kim, H.J.;Joe, K.Y.;Kye, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.339-342
    • /
    • 1996
  • Driving the electrodeless fluorescent lamp, the high ac voltage with high frequency is required. The linear power amplifier has been widely used as a driving circuit of electrodeless fluorescent lamp. However, the low efficiency of the power amplifier causes the driving circuit to be replaced by a PWM switching inverter. In order to use a PWM switching inverter as the driving circuit of an electrodeless fluorescent lamp, the high switching frequency is required. But due to the switching loss at switches of the inverter, the limitation of high switching frequency appears in the inverter. One solution to this limitation is to reduce the switching loss by using the zero voltage switching technique. In this paper, zero voltage switching resonant inverter for driving an electrodeless fluorescent lamp is discussed. The results of analysis about the inverter are presented and the equations for design are established. And the validity of the analyzed results are verified through the experiment.

  • PDF

Comparison of the Heat transport Limitations for Screen Mesh Wick and Sintered Metal Wick Heat Pipes by Theoretical Analysis (이론적 해석에 의한 스크린 메쉬윅과 소결윅 히트파이프의 열수송 한계 비교)

  • Kim Keun-Bae;Kim Yoo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.267-274
    • /
    • 2004
  • Theoretical analysis for predicting the heat transport limitations of screen mesh wick and sintered wick heat pipes was performed. The heat pipe diameter was 8mm and water was used for working fluid. For the 250 mesh, each capillary pressures and heat transport limitations, thermal resistances were analyzed according to the operating temperatures, wick thicknesses and inclination angles, based on the effective capillary radius (r$\_$c/), porosity ($\varepsilon$) and permeability (K). The wick capillary limitation was increased as the operating temperature and the wick thickness were increased, and generally the sintered wick showed higher heat transport limitations than that of the screen wick. The thermal resistance of the screen wick was higher than that of the sintered wick and both thermal resistances were linearly increased as the wick thickness was increased.