• 제목/요약/키워드: light transmission

검색결과 1,217건 처리시간 0.03초

사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구 (An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation)

  • 정미화
    • 한국직업건강간호학회지
    • /
    • 제3권호
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • 소비자의 부정적 브랜드 루머의 수용과 확산 (Consumer's Negative Brand Rumor Acceptance and Rumor Diffusion)

    • 이원준;이한석
      • Asia Marketing Journal
      • /
      • 제14권2호
      • /
      • pp.65-96
      • /
      • 2012
    • 루머는 신뢰할 만한 타당한 근거나 이유가 없음에도 불구하고 광범위하게 이야기되는 일상적인 대화나 의견으로서 오랜기간 소비자 개개인의 사적 영역의 문제였다. 그러나 대중의 사랑과 주목을 받는 기업이나 브랜드는 선천적으로 소비자의 관심으로부터 멀어질 수 없으며, 항상 루머의 주요한 소재가 되어 왔다. 그 결과 현대의 소비자 커뮤니케이션 환경에서 루머는 기업 경영활동에 중요한 위기 요인이 되고 있다. 기업과 브랜드들이 당면하는 소비자 루머들은 크게 기업과 관련된 음모성 루머와 상품과 직접적 관련이 있는 오염성 루머로 나누어지며 국내외에서 많은 위기 사례들이 발견되고 있다. 심지어 P&G, SK, 현대, 삼성처럼 잘 정비된 홍보 조직을 갖춘 굴지의 대기업들조차 이런 루머로부터 자유롭지 못하며, 기존의 대응방식 역시 적절하지 못했던 것이 사실이다. 부정적 루머가 주목받아야 하는 이유는 해당 기업의 매출 및 점유율 하락은 물론 주식 가격에도 부정적인 영향을 미치며 오랜기간 구축해온 소비자와의 관계마저 황폐화시킬 가능성이 있기 때문이다. 최근 인터넷, 소셜 네트워크 서비스의 확산과 더불어 브랜드와 관련된 루머의 중요성은 더욱 증대하고 있으나 루머 연구는 지금까지 기업이나 마케팅 연구자의 정당한 주목을 받지 못하였다. 이에 본 연구는 루머의 다각적인 측면을 고려하는 상황주의자적 연구 패러다임을 기반으로 지각된 유용성, 원천 신뢰성, 메시지 신뢰성, 걱정, 생동감과 같은 루머와 관련된 속성들이 루머 수용강도와 루머 구전의도에 미치는 영향을 분석하였다. 이를 위하여 가상 브랜드와 루머가 제시되었으며, 실증조사를 통한 데이터 수집과 분석이 이루어졌다. 연구 결과에 따르면 원천 신뢰성, 메시지 신뢰성, 걱정, 생동감 같은 루머 특성 변수들은 루머 수용 강도에 유의한 영향을 미치고, 루머 수용강도는 루머 구전의도에 유의한 영향을 미치는 것으로 나타났다. 반면에 지각된 중요성은 루머 수용강도에 유의한 영향을 미치지 못하며, 상품 관여도의 조절효과 역시 유의하지 않은 것으로 나타났다. 본 연구는 주요한 실무적, 학문적 시사점을 제공하고 있다. 첫째, 루머를 자연발생적인 사회 현상이 아니라 소비자의 주요 활동의 일부이며, 마케터의 관심과 대응 커뮤니케이션 전략이 필요한 브랜드 관련 현상임을 주장하였다. 둘째, 브랜드 루머의 심리적, 사회적인 다차원적 구성 요인과 확산되는 경로를 제시함으로서 루머에 대한 능동적인 관리 가능성을 제시하였다. 셋째, 온라인상의 루머 활동이 기업 성과에 미치는 영향을 제시함으로서 기업들의 적극적인 온라인 커뮤니케이션 활동과 평판 관리의 필요성을 주장하였다. 넷째, 소비자의 걱정과 같은 부정적 정서가 루머의 온상이 되고 있음을 규명함으로서 소비자의 의혹을 불식시키기 위하여 정확하고 진실된 정보를 제공해야 함을 주장하였다. 다섯째, 루머의 유용성이 확산에 미치는 영향 가설이 기각되었으며, 상품 관여도의 조절 효과 역시 기각되었다. 이는 루머를 접하는 소비자의 입장에서 볼 때, 루머 자체가 무의미하더라도 단순한 재미나 호기심만으로도 얼마든지 확산될 가능성을 암시하고 있다. 일부 기업들은 사실이 아니라는 이유만으로 루머를 무시하거나 간과하는 경우들이 있으나, 기업의 예상과 다르게 루머가 얼마든지 확산될 수 있는 가능성을 보여주며, 기업의 보다 세심한 대응 전략의 필요성을 요구하고 있다.

    • PDF

    간흡충증(肝吸虫症)의 역학(疫學) - I. 고도유행지(高度流行地) 김해지방(金海地方)에 있어서의 간흡충감염(肝吸虫感染)의 현황(現況)과 자연추이(自然推移) (Epidemiological Studies of Clonorchiasis. - I. Current Status and Natural Transition of the Endemicity of Clonorchis sinensis in Gimhae Gun and Delta, a High Endemic area in Korea)

    • 김동찬;이온영;이종수;안장수;장영미;손성창;문익상
      • 농촌의학ㆍ지역보건
      • /
      • 제8권1호
      • /
      • pp.44-65
      • /
      • 1983
    • As a part of the epidemiological studies of clonorchiasis, this study was conducted to evaluate the current endemicity and the natural transition of the Clonorchis infection in Gimhae Gun and delta area a high endemic area in Korea in recent years, prior to the introduction of praziquantel which will eventually influence the status of the prevalence. The data obtained in this study in 1983 were evaluated for natural transition of the infection in comparison with those obtained 16 years ago in 1967 by the author(Kim, 1974). The areas of investigation, villages and schools surveyed, methods and techniques used in this study were the same as in 1967, except for the contents of the questionnaire for raw freshwater fish consumption by the local inhabitants. 1) The prevalence rate of clonorchiasis in the general population of the villages was 48.1% on the average out of a total of 484 persons examined. The average of those of the riverside-delta area was 65.2% and 43.0% in the inland area. Among the schoolchildren, the prevalence rate was 8.2% on the average out of a total of 1,423 examined. By area, the prevalence rate was 10.8% in the riverside delta area and 2.8% in the inland area. By sex, difference in the prevalence was seen only in the inhabitants of the inland area showing 52.4% in the male and 33.5% in the female. 2) In the natural transition of the infection, the prevalence rate among the inhabitants has decreased from 68.8% in 1967 to 48.1% in 1983, and in the schoolchildren from 56.4% in 1967 to 8.2% in 1983. The reduction rate was higher in the riverside-delta area than in the inland area. 3) In the prevalence rate by age, 11.9% was first seen in the 5-9 age group and the rate gradually increased up to 75.0% in the 50-59 age group. By sex, the rate was higher in the male than in the female in the 20-29 age group and over. 4) In the natural transition of the prevalence rate by age, the reduction rate of the infection during the past 16 years was greater in the younger age groups up to the 40-49 age group and reached the same level in the age group 50-59. Reduction was seen again in the age group over 60s. By sex, the reduction rate was greater in the female than in the male in the 20-29 age group and over. By area, the reduction rate was greater in the riverside delta area than in the inland area, particularly in the young age groups. 5) In the intensity of the infection among the cases, the mean egg out-put per mg feces per infected cases(EPmg) in the inhabitants was 6.3. EPmg of those of the river-side-delta area was 15.4 and that of the in-land was 2.8. On the other hand, in the schoolchildren, EPmg was 3.2, and no difference was seen between the two areas, the river-side-delta area and the inland area. 6) In the transition of the intensity of the infection by area, EPmg among the inhabitants inexplically increased from 7.8 in 1967 to 15.4 in 1983. This was probably caused by uneven specimen collection in the process of sampling the population. EPmg of the inhabitants in the inland area and those of the schoolchildren of both riverside delta and inland areas showed a similar decrease in the past 16 years. 7) The intensity of the infection by age showed a relatively low level in the 20-29 age group and below, and EPmg 5.1-9.5 was seen in the 30-39 age group and over. Sex, Epmg was 5.8 in the male and 4.7 the female. By in 8) In the transition of the intensity of the infection, EPmg decreased from 6.2 in 1967 to 5.4 in 1983. By age, in contrast to the figures of 1967 in which EPmg gradually increased with some fluctuation from 1.1 in the 0-4 age group to peak 10.5 in the 50-59 age group, in 1983 lower intensity of the infection was seen in the age group from 10-14 to 20-29 with the EPmg range of 0.6-2.7. 9) In the distribution of the clonorchiasis cases by the range of EPmg value, 43.2% of the cases were in 0.1 0.9 and 34.6% in 1.0-4.9. As a whole by cumulative percent, 44.6% of them were under 0.9 as light infection and 86.1% of them under 9.9 up to moderate infection. By sex, no difference was seen in Epmg. 10) In the transition of the distribution by the range of Epmg, the cases were distributed up to the range 80.0-99.9 in 1967 and to 60.0-79.9 in 1983. By cumulative percent, in the range of 0.1-0.9 and less, light infection, 34.3% of them were distributed in 1967 and 44.6% in 1983 with about 10% increase. In the range of 5.0-9.9 and less, up to moderate infection, 83.2% in 1967 and 86.1% in 1983 of the cases were seen, respectively. 11) The practice of raw freshwater fish consumption among the inhabitants seems to have decreased in recent years. Those who admitted to raw freshwater fish consumption in the last two years among the infected inhabitants were 59.3%, although 86.8% of them professed to have experience with raw freshwater fish consumption. 31.7% of those who have had experience of the raw freshwater fish consumption denied any further consumption in recent years. From an interview of 543 school-children, 24.1% of them admitted to an experience of raw freshwater fish consumption. However, those who have practised in the past two years comprized 17.9%. Those who denied raw freshwater fish consumption in recent years among those who had such experience were 26.0% out of 131 interviewed. The rate of raw freshwater fish consumption in both inhabitants and schoolchildren were higher in the male than in the female. On the contrary, the rate of those who did not practise in recent years among those who had experience of raw freshwater fish consumption was higher in the female than in the male. 12) The major reason for the reduction of raw freshwater fish consumption among the local inhabitants was the risk of the fluke infection. However, it has become apparent that such change of taste has resulted from water pollution impact which has affected throughout the areas of the freshwater systems in this locality since last several years. 13) In animal survey, Clonorchis infection was seen in 14.8% of 88 dogs examined and 3.7% of 27 house rats examined. It was noted that populations of dogs and cats have increased in the villages surveyed. Although the prevalence rate was lower in the present survey than those of 1967, the significance of the animals as the reservoir host has not changed. 14) Prevalence rate of Clonorchis infection by cercariae in the first intermediate host, Parafossarulus manchouricus, was 0.6% out of 517 snails examined. The infection rate was lower in comparison with 2.3% out of 2,124 examined in 1967. Moreover, sharp decreases in number and distribution of the intermediate host snails in many watershed areas of the huge freshwater systems in this locality seemed to reduce transmission of Clonorchis in connection with the intermediate host stage of its life cycle. 15) Clonorchis infection in the second intermediate fish hosts was relatively low. The mean number of Clonorchis metacercaria per fish in Pseudorasbora parva was 517 in 1983, whereas it was 1943 in 1968 through 1969. Environmental water pollution has also caused the decreased fish population density in these areas, and this has also apparently affected to the practice of raw freshwater fish consumption among the local inhabitants. 16) In conclusion, endemicity of Clonorchis infection in Gimhae Gum and delta area of the Nagdong River has sharply decreased during the past 16 years. The major cause of the regressive transition of the infection was the water pollution of the land water systems of this locality. The pollution has upset the ecosystems comprizing of the intermediate hosts of Clonorchis in many areas, and also affected to a significant extent to the discontinuance of the local inhabitants for raw freshwater fish consumption.

    • PDF

    애니메이션 입체 영화에 대한 연구 (Study of Animation 3-Dimensional Motion Picture)

    • 민경미
      • 만화애니메이션 연구
      • /
      • 통권9호
      • /
      • pp.127-142
      • /
      • 2005
    • Study of Animation 3-Dimensional Motion Picture국내뿐만 아니라 전 세계의 수백만의 인구가 영상을 접하고 있다. 영상은 움직이는 형상을 시각화 하는 것에서 지식, 정보 전달의 매체로서 자리 매김 하였다. 과학의 발전은 온라인(Online)시대를 열어주었고 온라인 시대의 정보습득은 지속적으로 고속화 되어, 과량의 정보 속에서 선택을 해야 하는 관객들을 함께 가속화 시키고 있다. 선택적인 측면에서 시각적인 전달 방법은 급변하는 시대의 요구에 맞게 변화하게 된다. 다량의 정보 속에서 순간의 선택을 받기 위한 일한으로, 1차적인 요건은 시선을 집중시키는 것이며, 그에 상응하는 만족감을 선사하는 것이다. 영상의 초기는 실제로 자신이 보고 있는 상황을 그대로 옮기고자 하는 욕구에서 출발한 것이다. 정지화면에서 만족하지 못한 인간은 움직이는 화면(Film)을 개발하였고 양안의 시점의 차이와 광선의 자극 반응을 감안한 실제 인지하는 시점보다 더 입체감을 만들어내는 영상을 가늠 해내는 연구를 하게 된다. 이는 컬러 필름(Color Film)에서 입체영상 개발까지 놀라운 성과를 누리게 된다. 인간의 가시적인 면에 대한 욕망의 추구 즉, 극대화된 실재감(Reality) 있는 볼거리 추구는 영상이 포함되는 모든 분야에 지속적으로 요구되고 있다. 지금 수백만의 인구가 보편적으로 보고 있는 영상들은 평면적이다. 화면의 깊이 감(Depth)과 착시현상(Optical Illusion)은 효과적으로 현실감을 주며 정보를 전달한다. 하지만, 인간의 양안 시점차이로 인식하는 입체감은 평면속에서 만들어 내는 깊이 감으로는 현실감 있게 인식하는데 한계점이 존재한다. 이러한 한계를 만족시킬 입체 영상) 입체영상은 영화에서 시작되었으나, 20c후반기에 들어서면서 애니메이션 분야와 모바일, 광고 패널, 텔레비전등의 매체를 이용한 입체 영상의 개발로 인하여 특정 분야에 한정 시킬 수 없으므로 영상으로 칭한다. 입체 영상은 21c에 들어서면서 영상매체의 한 분야로 급부상하고 있다. 1900년 무렵부터 연구된 입체영화(3-Dimensional motion Picture)는 In여 년이 지난 지금 대중화를 눈앞에 두고 있다. 국내에서는 놀이 동산이나 박물관등에서 흔히 볼 수 있다. 하지만 앞으로는 HDW등의 대중화로 화질의 발전을 이룬 텔레비전 분야 등에서 실용화 될 전망이다. 국제적인 흐름과 함께 국내에서도 입체 영화에 대한 연구가 활성화 되어 영상산업의 한 주류로서 대두되고 있다. 이러한 상황에서 입체영상에 대한 이해와 콘텐츠(Contents)의 개발은 기술적인 진보에 발맞추어 준비되어야 한다. 본 논문은 이러한 기술적인 계보에 발맞춘 영상 콘텐츠 개발에 박차를 가하고자 앞으로의 발전분야에 대한 기술적인 면과 기법적인 면을 제시하여 기술만 앞서고 내용은 수입하는 수입국이기 보다는 미리 준비하여 비전문가나 타국의 기술에 선점 당하지 않는 분야로 성장할 수 있는 진보적인 영상 인들의 관심과 지속적인 연구를 독려하고자 한다.

    • PDF

    Sensory Information Processing

    • Yoshimoto, Chiyoshi
      • 대한의용생체공학회:의공학회지
      • /
      • 제6권2호
      • /
      • pp.1-8
      • /
      • 1985
    • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

    • PDF

    High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

    • H.S-Ching;Oh, M.ishi;M.Morimoto
      • 한국우주과학회:학술대회논문집(한국우주과학회보)
      • /
      • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
      • /
      • pp.17-17
      • /
      • 1993
    • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

    • PDF

    수도저위생산력(水稻低位生産力)의 원인구명(原因究明)에 관(關)한 영양생리적연구(營養生理的硏究) (Studies on Nutrio-physiology of Low Productive Rice Plants)

    • 박준규
      • Applied Biological Chemistry
      • /
      • 제17권1호
      • /
      • pp.1-30
      • /
      • 1974
    • 수도저위(水稻低位) 생산력(生産力)의 원인구명(原因究明)에 관(關)한 영양생리학적연구(營養生理적硏究)로 여러 가지 생육조건하(生育條件下)에서 품종별(品種別) 양분흡수(養分吸收) 및 동화기능(同化機能)과 양분(養分)의 체내(體內)에서의 이행양상(移行樣相)을 추구(追究)하는 한편 고수량지(高收量地) 벼와 저수량지(低收量地) 벼에 대(對)한 생육시기별(生育時期別)로 양분(養分)의 흡수(吸收) 체내무기양분(體內無機養分)과 수량(收量) 및 수량구성요소(收量構成要素)와의 관계(關係) 등(等)을 추구(追究)하여 저수량지(低收量地) 벼의 영양생리적(營養生理的) 저수요인(低收要因)을 밝히고저 본연구(本硏究)를 수행(遂行)하였던 바 그 결과(結果)를 요약(要約)하면 다음과같다. 1. 양분(養分)의 흡수력(吸收力)은 품종(品種)에 따라 차이(差異)가 있으며 인산(燐酸) 및 가리(加里)의 흡수력(吸收力)이 강(强)한 품종(品種)은 구사부에, 진흥(振興)이며 낮은 품종(品種)은 팔달(八達)이었다. 2. 근(根)의 ${\alpha}-naphthylamine$의 산화력(酸化力)과 인산(燐酸)의 흡수력(吸收力)과는 유의적(有意的)인 상관관계(相關關係)가 있으며 산화력(酸化力)이 높으면 인산(燐酸)의 흡수(吸收)가 증대(增大)되었바. 3, 탄소동화력( 炭素同化力)은 품종(品種)에 따라 차이(差異)가 있으며 노인도(老人稻), 구대내조욱(九大耐潮組) 3호(號), 수원(水原)82호(號), 진흥(振興) 등은 강(强)하고 대구조(大脚租), 관옥(關玉), 육우(陸羽) 132호(號)가 약(弱)하였다. 4, 질소(窒素)의 증시(增施)는 소비(少肥)에 비(比)하여 동화량(同化量)은 증가(增加) 되나 등화산물(同化産物)의 이삭으로의 이전(移轉)은 적었다5. 정상(正常) 생육(生育)한 벼에 비(比)하여 인산(燐酸), 가리(加里) 및 마그네슘이 결핍(缺達)된 벼는 전탄소동화량이(全炭素同化量)이 정상(正常) 벼 100에 비(比)하여 40이하(以下)로 현저(顯著)히 낮으며 그 순서(順序)는 Mg>P>K이고, 동화물(同化物)의 이전(移轉)에 장해(障害)가 큰 것은 K>Mg>P의 순(順)이었다. 6. 고수량지(高收量地) 벼는 저수량지(低收量地) 벼에 비(比)하여 총건물(總乾物) 생산량(生産量)이 현저(顯著)하게 많고 특(特)히 유수형성기(幼穗形成期) 이후(以後)에 증가량(增加量)이 더욱 현저(顯著)하였다. 7. 고수량지(高收量地) 벼는 출수기(出穗期)에 옆면적(葉面積)이 최고(最高)에 달(達)하였다가 그 이후(以後) 완만(緩慢)하게 줄어지나 저수량지(低收量地) 벼는 출수이전(出穗以前)에 엽면적(葉面積)이 최고(最高)에 달(達)하였다가 출수이후(出穗以後)에 급격(急激)히 감소(減少)되며 그 원인(原因)은 하엽(下葉)의 조기고사(早期枯死)에 기인(起因)되었다. 8. 고수량지(高收量地) 벼는 저수량지(低收量地) 벼에 비(比)하여 생육초기(生育初期)에는 투과광율(透過光率)이 높고 생육후기(生育後期)에 낮았으나 투과광율대(透過光率對) 엽면적비(葉面積比)는 고수량지(高收量地) 벼에서 높았다. 9. 순동화량(純同化量)은 저수량지(低收量地) 벼에 비(比)하여 고수량지(高收量地)벼에서 많았으며 이는 또한 엽면적(葉面積)이 증가(增加)됨에 따라 감소(減少)되었다. .10. 고수량지(高收量地) 벼는 저수량지(低收量地) 벼에 비(比)하여 유수형성기(幼穗形成期) 이후(以後) 체내질소(體內窒素), 가리(加里) 및 규산(珪酸)의 함유율(含有率)이 높으면서 $K_2O/N$, $SiO_2/N$ 비(比)가 높았다.11. 저수량지(低收量地) 벼는 고수량지(高收量地) 벼에 비(比)하여 출수기(出穗期)에 보유(保有)된 질소(窒素), 인산(燐酸), 가리(加里) 및 마그네슘등이 출수이후(出穗以後) 이삭으로의 이행율(移行率)이 높았다. 이는 저수량지(低收量地) 벼가 생육후기(生育後期)에 양분(養分)의 흡술량(吸收量)이 부족(不足)하여 체내(體內) 저장양분(貯藏養分)이 재이동(再移動)되기 때문이며 따라서 하엽(下葉)은 양분부족(養分不足)으로 조길고사(早期桔死)가 많아지는 것으로추정(推定)되었다. 12. 고수량지(高收量地) 벼는 질소흡수(窒素吸收)가 전생육기간(全生育期間)을 통(通)하여 완만(緩慢)하며 출수이후(出穗以後)에도 흡수량(吸收量)이 많으나 저수량지(低收量總) 벼는 출수이전(出穗以前)에 많고 출수이후(出濾以後)는 거의 흡수(吸收)되지 않았다. 13. 출수기(出穗期)의 체내(體內) 질소(窒素), 가리(加里) 함유율(含有率)과 수량(收豊)과는 현저(顯著)한 정(正)의 상관(相關)이 성립(成立)되였으며 수확기(收獲期)의 가리(加里), 규산함유율(珪酸含有率) 그리고 $K_2O/N$, $SiO_2/N$과 수량(收量)과도 현저(顯著)한 정(正)의 상관관계(相關關係)가 성립(成立)되었다. 14. 출수기(出穗期)에 보유(保有)된 전분(澱粉)이 이삭으로의 이전(移轉)은 고수량지(高收量地) 벼가 약(約) 10%인데 반(反)하여 저수량지(低收量地) 벼는 약(約) 40%로 많았다. 따라서 저수량지(高收量地) 벼는 출수(出穗) 이후(以後) 동화의존도(同化依存度)가 높았다. 15. 고수량지(高收量地) 벼는 저수량지(低收量地) 벼에 비(比)하여 질소(窒素), 인산(燐酸), 가리(加里), 규산(珪酸) 및 망간의 흡수량(吸收量)이 현저(顯著)하게 많았고 생육시기별(生育時期別) 흡수량(吸收量)의 차이(差異)는 유수형성기(幼穗形成期) 전후(前後)에 현저(顯著)하였다. 16. 수확기(收穫期)의 질소(窒素), 인산(燐酸), 가리(加里), 석탄(石炭), 마그네슘, 규산(珪酸) 및 망간의 총흡수량(總吸收量)과 수량(收量)과는 고도(高度)의 정(正)의 상관관계(相關關係)가 인정(認定)되었다. 17. 수확기(收穫期)에 질소(窒素), 인산(燐酸), 가리(加里), 석탄(石炭), 마그네슘 및 규산(珪酸)의 흡수량(吸收量)과 수당입수간(穗當粒熱間)에, 질소(窒素) 및 가리(加里)의 흡수량(吸收量)과 수수(穗數)와는 유의적(有意的)인 정(正)의 상관관계(相關關係)가 성립(成立)되었다.

    • PDF