• 제목/요약/키워드: light sources

검색결과 1,096건 처리시간 0.031초

몬테카를로법을 이용한 실내조도 계산 (Interior Lighting Calculation using Monte-Carlo Method)

  • 김훈
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권5호
    • /
    • pp.19-26
    • /
    • 1992
  • A computer program to calculate the illumination distributions of a room interior was made. The room has a light source with arbitrary intensity distribution. The program follows the paths of the particles from the light sources, and the illumination distribution is calculated by repeating this following to many particles. Monte Carlo method is applied to the decision of the direction of the particle from light source, and the new direction of the reflected particles. Making simulation program on this basis, illumination distributions were measured for various light sources and wall surfaces tocertify the calculated results. As a results, it is known that the calculated distribution would be correct if the size of the light source is sufficiently smaller than the size of the room.

  • PDF

하이브리드 태양광 LED 가로등 시스템 연구 (A study on hybrid solar LED street light system)

  • 이동혁
    • Design & Manufacturing
    • /
    • 제16권2호
    • /
    • pp.20-25
    • /
    • 2022
  • In line with the rapid economic growth of many countries, fossil fuel energy sources are also rapidly depleting. Therefore, the price is also rising rapidly, so it is necessary to develop new and renewable energy sources such as hydropower, geothermal power, nuclear power, wind power and solar energy to replace fossil fuel energy in the future. In this study, development of rotating concentrator module system, development of rotating module control control system, development of lamp and charge control controller, configuration and prototype production of rotating concentrating solar LED street light system, efficiency of rotating concentrating solar LED street light, and power production. The research was conducted in the order of evaluation of comprehensive performance tests such as consumption and consumption. As a result, the developed high-efficiency rotation-concentrating hybrid solar LED street light module system has a 50% higher light-gathering efficiency than existing products by tracing sunlight by self-developing a rotation-collecting module on existing solar LED street lamps according to the characteristics of Korea's topography. and the power generation was improved by more than 40%.

초기 우식 병소에서 광원에 따른 형광효과 비교 (A COMPARISON OF FLUORESCENCE EFFECT OF VARIOUS LIGHT SOURCES IN EARLY ENAMEL CARIES)

  • 전정훈;이난영;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제32권4호
    • /
    • pp.611-619
    • /
    • 2005
  • 본 연구의 목적은 초기 우식 병소에서 광원에 따른 형광효과를 비교하는 것으로 정량 분석형 laser/light 형광법(Quantitative laser/light-induced fluorescence, QLF)을 이용하여 아르곤 레이저광, 할로겐광, 발광다이오드광(LED), 플라즈마광의 형광효과를 비교하였다. 발거된 60개의 치아를 선정한 후, 인공우식용액에 노출되지 않을 부분에 nail varnish를 도포하였고 치아는 24, 48, 72시간 동안 인공우식용액에 보관되었다. 건조 후 QLF영상으로 초기 우식 부위의 광밀도 차이에 의한 탈회정도가 기록되었다. 또한 조영제를 이용하여 동일한 방법으로 실험하였고 다음과 같은 결과를 얻었다 염료를 이용하여 같은 방법으로 실험하여 또 다른 결과를 얻었다. 1. 각 군의 평균 광밀도를 볼 때, 플라즈마광이 세 군 모두에서 다른 광원들 보다 높았다(p<0.05). 2. 세 군 사이에서 평균 광밀도를 비교해 볼 때, 플라즈마광과 할로겐광이 차이를 보였다(p<0.05). 3. 조영제를 사용하였을 경우 평균 광밀도를 비교해 볼 때, 플라즈마광이 세 군 모두에서 다른 광원들보다 높았고 (p<0.05), 발광다이오드광(LED)와 아르곤 레이저광을 제외한 모든 광원이 차이를 보였다(p<0.05). 4. 조영제를 사용하지 않은 경우와 사용한 경우 평균 광밀도를 비교해 볼 때, 사용한 경우에 모든 광원의 평균 광밀도 차이가 컸다.

  • PDF

박물관 조명에 관한 국내 연구 동향 분석 (An Analysis of Domestic Research Trends on Museum Lighting)

  • 김지원;강대일
    • 헤리티지:역사와 과학
    • /
    • 제52권3호
    • /
    • pp.188-199
    • /
    • 2019
  • 본 연구에서는 박물관 조명과 관련하여 지난 30년간 우리나라에서 수행된 중요 연구들을 되짚어보고자 학술 논문을 중심으로 연구 동향을 조사하였다. 현재까지 박물관 조명으로 사용된 광원과, 그 한계로 인해 보존환경이 발전되는 과정 중에 우리나라에서 수행된 박물관 조명에 의한 유물 열화에 대한 중요 연구 사례들을 되짚어보고 최근 적용되는 LED 광원에 의한 연구 현황을 살핌으로써 향후 연구가 나아갈 방향을 제시해보고자 하였다. 박물관 조명에 관한 연구의 궁극적인 목표는 장기간 사용에 대해 보존 효과를 높이는 것이며, 각 시대별 최신 광원을 대상으로 연구가 이루어져왔다. 1990년대 이전에는 최초의 박물관 전시 조명인 백열전구와 형광램프를 한지에 조사(照射)하여 광원에 의한 지류 유물의 안정성 평가가 이루어졌으며, 1990년대에는 할로겐램프와 HID램프의 도입으로 광원 자체의 특성 분석 및 조도 기준 제시에 관한 연구가 주를 이루었다. 2000년대에는 그간 연구되었던 광원의 특성을 바탕으로 박물관의 조명환경 측정을 실시하여, 보존 측면에서 유물의 안정성뿐만 아니라 관람 정서를 향상시킬 수 있는 방향의 연구가 진행되었다. 또한 2010년 이후에는 LED램프가 도입되면서 LED램프에 의한 유물 열화 연구가 확대되는 동시에 blue spike 영역의 축소, 연색성 증대 등 광원 자체의 개선 연구가 이루어졌다. 박물관 및 미술관에서 사용되는 조명이 진보함에 따라 전시품 보존 기준의 방향도 조도 중심에서 유물의 색상 및 광원의 복사속에 이르기까지 변화해왔으며, 그에 따라 발전된 기준 마련의 필요성이 제기되었다. 보다 면밀한 유물 변성 조건의 표준화 마련을 위해서는 장기적인 안목에서의 박물관 조명에 관한 꾸준한 연구가 기획되어야 할 것이다.

인공광원이 사과 대목 M.9 묘 생육에 미치는 영향 (Effect of Artificial Light Sources on the Growth of Apple Rootstock M.9 Seedling)

  • 소은희;안진희;김재경;윤여중;박수정;나종국;최기영
    • 생물환경조절학회지
    • /
    • 제27권4호
    • /
    • pp.341-348
    • /
    • 2018
  • 본 실험은 영양번식계 사과배양묘의 규격묘 생산을 위한 기초자료를 얻고자 순화된 사과 M.9묘의 광질 영향이 생육과 광합성에 미치는 영향을 알아보고자 6주간 환경이 조절된 룸에서 재배하였다. 인공광원은 6처리[적색(R), 청색(B), 백색(W), RBUV(UV-A 함유된 R7B3), RBW(R3B1W1), SMF(고압나트륨+메탈할라이드+형광등)]이며 식물에 조사된 광량은 $154{\pm}4{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$이였다. 사과 묘 생육 특성 반응은 3주와 6주 각각 인공광원에 따라 차이를 보였다. 사과 묘 초장이 3주에는 R, RBUV, RBW, SMF 광원에서 높았으나, 6주에는 R 광원에서 높았다. 묘경은 3주째는 처리 간 차이가 없었으나, 6주째는 RBUV, RBW 광원에서 높았으며, 엽수는 3주와 6주 모두 RBUV 광원에서 가장 많았다. 엽록소 함량 SPAD 값은 3주째는 B와 RBUV 광원과 광원에서 높았으나 6주째는 차이가 없었다. 초장을 기준으로 인공광원 처리기간 중 생장율은 R 광원에서 1.12mm/day로 가장 빨랐으며, RBUV 광원(0.95mm/day), RBW 광원(0.86mm/day), SMF 광원 (0.76mm/day), W 광원(0.69mm/day), B 광원(0.44mm/day) 순 이였다. 엽면적은 RBUV, RBW 광원에서 높았고, B 광원에서 낮았으며, 비엽면적은 W 광원에서 높았으며, 생체중과 건물중은 RBUV 광원에서 높았다. 처리 6주째 광합성율은 B 광원에서 가장 높았으며, R 광원에서 낮았고, 기공전도도와 증산율은 B와 W 광원에서 높았다. 따라서 순화된 기내 배양 사과 M.9묘의 초장, 묘경, 엽수, 생체중 등 생육을 위해서는 광파장 영역이 R, R+B가 혼합비율이 높았던 R, RBUV, RBW 광원이 적합하였다.

Vegetative Growth Characteristics of Phalaenopsis and Doritaenopsis Plants under Different Artificial Lighting Sources

  • Lee, Hyo Beom;An, Seong Kwang;Lee, Seung Youn;Kim, Ki Sun
    • 원예과학기술지
    • /
    • 제35권1호
    • /
    • pp.21-29
    • /
    • 2017
  • This study was conducted to determine the effects of artificial lighting sources on vegetative growth of Phalaenopsis and Doritaenopsis (an intergeneric hybrid of Doritis and Phalaenopsis) orchids. One - month - old plants were cultivated under fluorescent lamps, cool - white light - emitting diodes (LEDs), or warm - white LEDs at 80 and $160{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. The blue (400 - 500 nm) : green (500 - 600 nm) : red (600 - 700 nm) : far - red (700 - 800 nm) ratios of the fluorescent lamps, cool-white LEDs, and warm-white LEDs were 1 : 1.3 : 0.8 : 0.1, 1 : 1.3 : 0.6 : 0.1, and 1 : 2.7 : 2.3 : 0.4, respectively. Each light treatment was maintained for 16 weeks in a closed plant-production system maintained at $28^{\circ}C$ with a 12 h photoperiod. The longest leaf span, as well as the leaf length and width of the uppermost mature leaf, were observed in plants treated with warm-white LEDs. Plants grown under fluorescent lamps had longer and wider leaves with a greater leaf span than plants grown under cool-white LEDs, while the maximum quantum efficiency of photosystem II was higher under cool-white LEDs. The vegetative responses affected by different lighting sources were similar at both 80 and $160{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Leaf span and root biomass were increased by the higher light intensity in both cultivars, while the relative chlorophyll content was decreased. These results indicate that relatively high intensity light can promote vegetative growth of young Phalaenopsis plants, and that warm - white LEDs, which contain a high red-light ratio, are a better lighting source for the growth of these plants than the cool-white LEDs or fluorescent lamps. These results could therefore be useful in the selection of artificial lighting to maximize vegetative growth of Phalaenopsis plants in a closed plant - production system.

발광영상에 대한 정량화 방법 개발 (Development of Quantification Method for Bioluminescence Imaging)

  • 김현식;최은서;탁윤오;최흥국;이주영;민정준;이병일
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권5호
    • /
    • pp.451-458
    • /
    • 2009
  • 목적: 광학적 분자 발광영상은 발광효소를 이용하여 발광하는 빛의 신호를 영상화하는 기법이다. 발광하는 광량이 분자 변화 또는 세포 수와 비례하고 신호 대 잡음비가 좋아서 영상을 얻고, 정략분석이 가능하다. 이 연구에서는 정량적 분석을 위해 비례적 측정 정량화기법을 개발하였다. 대상 및 방법: 개발 중인 ALIS (animal light imaging system) 광학발광영상 카메라에서 박테리아 수를 달리한 박테리아 광원 3가지와 또 다른 3가지 광원을 이용하여 발광영상을 측정하였다. 일정한 세기의 광원에 대해서 측정 방법을 수학적으로 표현하기 위해 cd와 광속의 개념을 이용하여 간단한 수식을 유도하였다. 실험을 통해 측정시간 1초를 기준으로 얻어진 값으로 표준 정량화 함수를 얻었다. 얻어진 정량화 함수를 이용하여 박테리아를 이용한 실험에 필요한 함수의 상수 값을 구했으며, 세 가지 세기가 다른 광원을 이용하여 측정한 값을 측정시간과 함께 정량화 식에 대입하여 측정하였다. 결과: 표준측정함수를 이용하여 측정시간에 비례하는 정량적 값을 얻을 수 있었다. 정량화결과를 측정시간으로 나눠준 값은 일정하였으며, 측정시간에 대비한 비례적 값을 얻을 수 있었다. 결론: 측정한 결과를 정량화 함수에 대입하여 정량화시킨 값은 표준정량화 하기에 적합하였다. 이 정량화 방법은 다른 광학적 분자영상 장비에 적용하여도 빛의 세기를 표준화 시킬 수 있을 뿐 만 아니라 성격이 다른 각각의 광원에 대해서도 보다 정량적인 분석을 시행할 수 있으므로, 새로운 표준 정량화 방법으로 발전시킬 수 있을 것으로 기대한다.

Evaluation of Impact Sound Insulation Properties of Light-Framed Floor with Radiant Floor Heating System

  • Nam, Jin-Woo;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.75-84
    • /
    • 2002
  • In order to find out impact insulation properties, various types of current radiant floor heating systems and light-framed floors that are used in light-framed residential buildings were evaluated for two types of impact sources at the same time. Sound Pressure Level (SPL) was different from each impact sources for those spectrum patterns and peaks. In case of light-framed floor framework, the excitation position and the assumed effective vibrating area have effects on sound pressure level but it is not considerable, and Normalized SPL was reduced for each frequency by increasing the bending rigidity of joist. The mortar layer in the radiant heating system had relatively high density and high impedance, therefore, it distributed much of the impact power when it was excited, and reduced the Normalized SPL considerably. Nevertheless, Increasing a thickness of mortar layer had little influence on SPL. Ceiling components reduced the sound pressure level about 5~25 dB for each frequency. Namely, it had excellent sound insulation properties in a range from 200 to 4,000 Hz frequency for both heavy and lightweight impact sources. Also, there was a somewhat regular sound insulation pattern for each center frequency. The resilient channel reduced the SPL about 2~11 dB, irrelevant to impact source. Consequently, current radiant floor heating systems which were established in light-framed residential buildings have quite good impact sound insulation properties for both impact sources.

RGB 광원을 사용한 고효율 LCD Color-matching BLU의 광학적 설계 (Optimized Optical Design of LCD Color-matching BLU Using an RGB Light Source)

  • 전화준;곽진석;권진혁
    • 한국광학회지
    • /
    • 제30권3호
    • /
    • pp.101-105
    • /
    • 2019
  • LCD의 광 효율을 향상시키기 위해 LCD backlight unit (BLU)의 광원으로 적색, 녹색, 청색의 광원을 사용하였으며, RGB 광은 lenticular lens array (LLA)를 통해 집광되어 각각 컬러 필터의 적색, 녹색, 청색 필터에 색일치되는 조건으로 광이 지나도록 설계하여 시뮬레이션하였다. 광원의 위치에 따라 Type-A와 Type-B 두 가지 방식으로 시뮬레이션을 진행하였으며, 그 결과 LLA를 사용하지 않았을 때와 비교하여 Type-A는 휘도가 210%로 상승하였으며, Type-B는 270% 상승함을 확인하였다. LLA의 최적의 조건은 렌즈의 높이가 $25{\mu}m$, 렌즈 간의 간격이 $3{\mu}m$일 때, 효율이 최대가 됨을 확인하였다.

적색광을 이용한 국화의 개화조절 (Flowering Control by Using Red Light of Chrysanthemum)

  • 홍성창;권순익;김민경;채미진;정구복;소규호
    • 한국환경농학회지
    • /
    • 제32권2호
    • /
    • pp.123-127
    • /
    • 2013
  • 적색광을 이용한 국화의 일장연장 처리기술을 개발하기 위하여 국화의 개화억제를 위한 적색광 강도를 구명하고 생육에 대한 영향을 검토하였다. 국화는 적색광에 의한 파야처리로 개화가 억제되었고 연속된 초적색광 처리로 개화하여 개화의 광가역적 반응을 나타냈다. 인공광 생육실 환경하에서 적색광 $1.4{\mu}mol/m^2/s$ (PAR) 로 일장연장 처리시 국화의 개화가 완전히 억제되었다. 적색광 $1.4{\mu}mol/m^2/s$ 처리는 관행의 전구식형광등 50 Lux 처리와 같이 국화의 개화를 억제시켰다. 적색 LED를 이용한 일장연장 처리로 관행의 전구식형광등 처리보다 국화의 초장은 17 %, 엽면적은 48 % 유의하게 증가하였고 엽수와 생체중은 각각 11 %, 36 % 증가하는 경향이었다.