• 제목/요약/키워드: light rainfall

검색결과 70건 처리시간 0.021초

라디오존데 관측자료를 이용한 UHF 윈드프로파일러 바람관측자료의 품질평가 (Quality Evaluation of Wind Vectors from UHF Wind Profiler using Radiosonde Measurements)

  • 김광호;김민성;서성운;김박사;강동환;권병혁
    • 한국환경과학회지
    • /
    • 제24권1호
    • /
    • pp.133-150
    • /
    • 2015
  • Wind profiler provides vertical profiles of three-dimensional wind vectors with high spatiotemporal resolution. The wind vectors is useful to analyze severe weather phenomena and to validate the various products from numerical weather prediction model. However, the wind measurements are not immune to ground clutter, bird, insect, and aircraft. Therefore, quality of wind vectors from wind profiler must be quantitatively evaluated prior to its application. In this study, wind vectors from UHF wind profiler at Ganwon Regional Meteorological Administration was quantitatively evaluated using 27 radiosonde measurements that were launched every two or three hours according to rainfall intensity during Intensive Observation Period (IOP) from June to July 2013. In comparison between two measurements, wind vectors from wind profiler was relatively underestimated. In addition, the accuracy and quality of wind vectors from wind profiler decrease with increasing beam height. The accuracy and quality of the wind vectors for rainy periods during IOP were higher than for the clear-air measurements. The moderate rainfall intensity lead to multi-peaks in Doppler spectrum. It results in overestimation of vertical air motion, whereas wind vectors from wind profilers shows good agreement with those from radiosonde measurements for light rainfall intensity.

대기질 예측을 위한 기후·대기환경 통합모델링시스템 (ICAMS)의 기온 및 강수량 예측 능력 평가 (Evaluation of Temperature and Precipitation on Integrated Climate and Air Quality Modeling System (ICAMS) for Air Quality Prediction)

  • 최진영;김승연;홍성철;이재범;송창근;이현주;이석조
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.615-631
    • /
    • 2012
  • This study provides an evaluation for capability of Integrated Climate and Air quality Modeling System (ICAMS) on future regional scale climate projection. Temperature and precipitation are compared between ground-level observation data and results of regional models (MM5) for the past 30 years over the Korean peninsula. The ICAMS successfully simulates the local-scale spatial/seasonal variation of the temperature and precipitation. The probability distribution of simulated daily mean and minimum temperature agree well with the observed patterns and trends, although mean temperature shows a little cold bias about $1^{\circ}C$ compared to observations. It seems that a systematic cold bias is mostly due to an underestimation of maximum temperature. In the case of precipitation, the rainfall in winter and light rainfall are remarkably simulated well, but summer precipitation is underestimated in the heavy rainfall phenomena of exceeding 20 mm/day. The ICAMS shows a tendency to overestimate the number of washout days about 7%. Those results of this study indicate that the performance of ICAMS is reasonable regarding to air quality predication over the Korean peninsula.

분포형 비차등위상차를 이용한 S-밴드 이중편파레이더의 정량적 강우 추정 (Quantitative Rainfall Estimation for S-band Dual Polarization Radar using Distributed Specific Differential Phase)

  • 이건행;임상훈;장봉주;이동률
    • 한국수자원학회논문집
    • /
    • 제48권1호
    • /
    • pp.57-67
    • /
    • 2015
  • 이중편파레이더는 강우입자의 모양, 크기, 위상, 방향에 대한 정보를 제공해줌으로써 단일편파레이더보다 정확한 정량적 강우 추정에 장점이 있다. 본 연구에서는 대표적인 이중편파레이더 강우 추정 알고리즘인 JPOLE 알고리즘과 CSU 알고리즘을 이용하여 강우량을 산정 비교하였다. 이 두 알고리즘은 강우의 크기에 따라 반사도, 차등반사도, 비차등위상차를 각각 이용하거나 조합하여 강우량을 계산한다. 비차등위상차는 강우입자의 모양과 분포밀도에 대한 정보를 주는 차등위상차에 필터링이나 회귀분석기법을 이용하여 계산되는데, 대류성 강우 지역에서는 비차등위상차의 첨두값이 과소 추정되거나 음의 값을 보일 수 있으며, 약한 강우지역에서는 진동하기도 한다. 본 연구에서는 이러한 문제를 해결하고자 Lim et al. (2013)에서 제안된 새로운 분포형 비차등위상차 산정방법의 이용을 제안하였다. 2012년도의 두 강우사상에 대한 국토교통부의 비슬산 레이더 자료를 이용하여 분포형 비차등위상차를 산정한 후 강우 추정 알고리즘에 적용하였다. 산정된 분포형 비차등위상차는 첨두값이 개선되었으며, 크게 진동하거나 음의 값이 산정되지 않았다. 이를 이용하여 추정된 강우량에 있어서는 일강우량 80mm 이상의 강한 강우에 대해 일강우량의 누적값이 AWS 관측값에 가깝게 개선되는 것을 확인하였으며 80mm 이하의 약한 강우에서는 개선 정도가 미약하였다. 이는 강우 추정 알고리즘에서 강우강도가 높은 경우에 비차등위상차가 사용되고, 낮은 경우에는 반사도와 차등반사도가 사용되기 때문인 것으로 판단된다. 본 연구를 통해 향후 이중편파레이더를 이용한 강우량 추정의 정확도를 향상시킬 수 있을 것으로 기대된다.

임도개설(林道開設)이 계류수질(溪流水質)에 미치는 영향(影響)(I) - 임도개설(林道開設)에 따른 부유토사량(浮遊土砂量)의 변화(變化) - (Effects of Forest Road Construction on Stream Water Qualities(I) - The Variation of Suspended Sediment by Forest Road Construction -)

  • 전근우;김민식;에자키 츠기오
    • 한국산림과학회지
    • /
    • 제85권2호
    • /
    • pp.280-287
    • /
    • 1996
  • 강원대학교(江原大學校) 임과대학(林科大學) 부속연습림(附屬演習林)내의 임도밀도가 상이한 3유역(유역(流域) A : 6.67m/ha, B : 5.52m/ha 및 C : 미개설(未開設))의 산지급류하천을 대상으로 임도개설 전 후인 1994년 및 1995년의 강우량 변화에 따른 부유토사의 유출량 변화를 분석한 결과 다음과 같은 결론을 얻었다. 1. 일강우량(日降雨量)이 적은 5~6월 사이에는 1994년과 1995년 모두 일유출량(日流出量)이 $0.25{\times}10^4m^3/day$ 이하였으나, 호우기(豪雨期)인 7~8월에는 일강우량에 비례하여 강우기간 중에는 $5.0{\times}10^4m^3/day$ 이상을 나타내는 등 일유출수량은 일강우량의 증감에 민감하게 반응하였다. 그러나 일유출량이 $25{\times}10^4m^3/day$ 이상은 1994년에는 2회였으나, 1995년에는 7회로 강우량이 풍부하였다. 2. 부유토사량은 임도개설전의 일강우량(日降雨量) 74mm, 92mm 및 120mm와 임도개설후의 일강우량 21mm 및 47mm에는 3유역 모두 하천수(河川水) 규제기준인 25mg/l 이하였다. 그러나 192mm의 강우에는 C유역은 변화가 없었으나, A와 B유역의 평균 부유토사량은 1,525mg/l 및 775mg/l으로 하천수 규제기준의 61배 및 31배였으며, 강우종료후 35시간동안 지속적으로 유출되었다. 3. 최대부유토사량(最大浮遊土砂量) 역시 임도개설전의 강우와 임도개설후의 적은 강우에서는 하천수 규제기준 이하였다. 그러나 일강우량 192mm인 경우에 A, B유역의 최대부유토사량은 하천수 규제기준씩 526배와 108배인 13,150mg/l 및 2,690mg/l을 기록하여 토사유출에 따른 수질오염을 시각적으로 파악할 수 있었다. 이상과 같이 임도개설이 부유토사 유출에 크게 영향을 미치며, 특히 임도밀도가 높은 유역일수록 강우량이 증가함에 따라 다량의 토사가 유출되고 있음이 확인되었으므로 부유토사의 생산원(生産源)인 임도비탈면 보호를 위한 식생공(植生工) 및 토목공(土木工)은 물론 침사지(沈砂池)와 같은 방재시설(防災施設)에 대한 대책을 강구해야 할 것이다.

  • PDF

강우 강도에 따른 대기 중 미세먼지 저감효과와 강우수질 특성 연구 (The Washing Effect of Precipitation on PM10 in the Atmosphere and Rainwater Quality Based on Rainfall Intensity)

  • 박혜민;변명화;김태용;김재진;류종식;양민준;최원식
    • 대한원격탐사학회지
    • /
    • 제36권6_3호
    • /
    • pp.1669-1679
    • /
    • 2020
  • 본 연구는 강우 강도에 따른 대기 중 미세먼지(particulate matter, PM) 저감효과와 미세먼지를 구성하는 주요 수용성 이온에 의한 빗물 수질(pH, 전기전도도(electrical conductivity, EC), 수용성 이온 농도) 변화를 평가하였다. 2020년 3월부터 7월까지 총 6번의 강우를 대상으로 부산 부경대학교 캠퍼스에 집수장치를 설치하여 pH와 EC를 실시간 측정하였으며, 강우의 양이온(Na+, Mg2+, K+, Ca2+, NH4+) 및 음이온(Cl-, NO3-, SO42-)의 농도는 이온크로마토그래피(ion chromatography, IC)를 이용하여 분석하였다. PM10 농도는 강우 전후로 자체제작한 미세먼지 센서를 이용하여 실시간으로 측정하였다. 총 282개의 빗물 샘플의 수질을 분석한 결과, 초기 강우의 pH는 평균 4.3으로 산성도가 높았으며, EC는 평균 81.9 μS/cm으로 평균 NO3- (5.4 mg/L), Ca2+ (4.2 mg/L), Cl-(4.1 mg/L)의 농도가 높게 검출되었다. 그리고 강우가 지속됨에 따라 pH는 증가하는 경향을 보였으며 EC는 상대적으로 감소하는 경향을 보였다. 강우 강도가 7.5 mm/h 이상(heavy rain)일 때 대기 중 평균 60% 이상의 PM10 농도 저감효율을 보였으며, 강우 강도 5 mm/h 이하(light rain)일 때 평균 40% 이하의 저감효율이 나타났다. 빗물 수질 분석 결과, 강우 강도가 증가할수록 초기 강우의 산성도와 EC가 증가하는 경향을 보였으며 초기 강우 내 이온 농도 또한 높은 농도로 검출되었다. 이는 대기 중 PM10이 초기의 강도 높은 강우에 따른 저감효과에 상당한 영향을 받는 것으로 판단된다.

항구적 한해대책을 위한 전천후농업용수시설의 농업수문학적 배경조사 연구 (I) (경북지방 중심) (Studies on the Agri-Hydrological Backgrounds of the All-Weather-Farming Water Resources Facilities to Prevent the Drought-Disasters Permanently (I))

  • 이기명;김조웅;서승덕;권무남
    • 한국농공학회지
    • /
    • 제22권4호
    • /
    • pp.73-81
    • /
    • 1980
  • In the light of these analysis of the recorded rainfall data from the meteorological observatories in Kyungpook area, hydraulic and hydrological data based on the representative watershed area and questionnaire or visiting letters to the 21 Land Reclamation Association in Kyungpook province, the hydrological backgrounds being the question to the irrigation facilities in Kyungpook Province or nation wide were studied partialy and the system of conservation and management of agricultural water sources facilities, prevention countermeasures to the drought and flood disasters, prediction of available surface waterflow and need or needless of new facilities establishment were reviewed in this paper. In the results, Technical and financial management and conservation investments of the already constructed ficalities should urgently and firstly be considered than the newly being established one.

  • PDF

최근 30년간 한반도 일 강수강도의 지역적 특성 (The Regional Characteristics of Daily Precipitation Intensity in Korea for Recent 30 Years)

  • 김은희;김맹기;이우섭
    • 한국지구과학회지
    • /
    • 제26권5호
    • /
    • pp.404-416
    • /
    • 2005
  • 이 연구는 최근 30년 동안 21개 지상관측소 일강수량 자료를 사용하여 한반도의 강수일수 및 강수강도의 지역성 및 계절성을 조사하였다. 일강수량 80 mm를 기준으로 다우와 소우로 나누어 그 특성을 조사하였으며, 강수일수 및 강도의 일차 선형경향도 함께 연구하였다. 호남 지방에서 소우에 의한 강수일수는 모든 계절에서 다른 지역에 비해 많으며, 특히 가을과 겨울철의 기여도가 상대적으로 컸다. 그러나 다우에 의한 강수일수는 대구를 중심으로 한 영남 지역에서 매우 적은 것으로 나타났다. 남해안 지방에서 강수량은 많고 강수일수가 적어 강수강도가 모든 계절에서 가장 크게 나타났으며, 연강수량에 대한 기여도는 다우와 소우 모두 다른 지역에 비해 크게 나타났다. 최근 30년간 대부분 지역에서 연강수량은 증가하는 선형경향을 보였는데, 대부분 다우에 의한 영향으로 나타났다. 한반도의 연 강수일수는 전반적으로 감소하는 선형경향을 보이지만, 다우에 의한 연 강수일수는 증가하는 선형경향을 보였다. 특히 충청과 경기지방에서 강수강도의 선형경향이 유의한 지역이 다수 발견되었는데, 이는 이 지역이 집중호우에 대한 위험도가 적지 않은 지역임을 말해주는 것이다.

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.

서울 지역에 내린 우수 pH 특성 (PH Characteristics of Precipitation in Seoul Area)

  • 이민희;에이지 히라이;모토이치 미야자키;테츠리 차지;전호
    • 환경위생공학
    • /
    • 제9권2호
    • /
    • pp.1-7
    • /
    • 1994
  • Rainwater was collected in Seoul area from January 1991 to December 1993 (over 3years) and by the analysis of the chemical components contained in rainwater, investigated the components that effect on rainwater pH Through the above studies the following conclusions were obtained. 1) Method for Averaging pH Volume weighted method is considered to be acceptable providing that precipitation is measured at the same time when the samples are taken, without precipitation data a simple averaging method should be the next choice. 2) Annual average rainwater pH was 4.98 in 1991, 4.80 in 1992, 4.67 in 1993, measurement range was 3.6-8.1. 3) In the relationship between rainwater pH and rainfall amounts rainwater pH for light rain(<15mm rainfall) was existent in the wide range(pH 4-7), but for heavy rain was corresponded to the annual average values. 4) Annual frequency of pH was Birrndat the frequency($\gamma $) between the density of the [$H^{+}$] and pH in the rainwater(over 3years ), $NO_{3}^{-}$ was excellent and the obtained results was 0.62 in 1992. Also In the correlation coefficient($\gamma $) according to the pH range $SO_{4}^{2-}, NO_{3}^{-}$, were 0.85 ,0.68 at 3.6 $Cl^-$ was 0.99(1993). At 4.1$NO_{3}^{-}(\gamma=0.48)$ in 1992, SO_4^{2-}($\gamma$=0.54), $NO_{3}^{-}(\gamma$=0.72), $Cl^- (\gamma$=0.49) in 1993. 6) pH values gradually increased with increase in $Ca^{2+}/SO_{4}^{2-}$.

  • PDF

농약의 토양 표면 유출에 관한 연구-II - 포장에서 인공강우에 의한 phorate의 유출특성 - (Study on Pesticide Runoff from Soil Surface-II - Runoff of Phorate by Simulated Rainfall in Field -)

  • 염동혁;김정한;이성규;김용화;박창규;김균
    • Applied Biological Chemistry
    • /
    • 제40권4호
    • /
    • pp.323-328
    • /
    • 1997
  • 토양살충제인 phorate를 포장에 살포한 후, 토성이 다른 두 지역의 소형시험구$(120\;cm{\times}120\;cm)$에서 호우(20 mm/hour) 및 세우(5 mm/hour) 조건의 인공강우에 의한 유출농도와 유출율을 측정하였으며, phorate의 유출 농도가 수서생물에 미치는 영향을 파악하기 위하여 유출수를 이용한 송사리에 대한 급성독성실험을 수행하였다. Phorate의 유출정도는 호우 및 세우조건에 따른 차이가 크지 않았고, 양토 및 사양토에서의 평균 유출농도는 각각 11.3 ppb 및 4.8 ppb였으며, 평균유출율은 0.50%이었는데, 양토지역에서 호우시 1.31%, 세우시 0.18%, 사양토지역에서 호우시 0.48%, 세우시 0.012%였으며, 양토지역에서 phorate 유출수를 54.4%로 희석하였을 때 송사리에 대한 급성독성치(96시간 $LC_{50}$)가 관찰되었고, 사양토지역의 유출수는 그 자체로도 50% 이상의 치사가 나타나지 않을 정도로 양토지역보다 독성이 낮았다.

  • PDF