• Title/Summary/Keyword: light limitation

Search Result 243, Processing Time 0.028 seconds

Effect of High Temperature and Growth Light Intensity on Fatty Acid Composition of Panax ginseng leaf (고온(高溫)과 재배광도(栽培光度)가 인삼(人蔘) 잎의 지방산(脂肪酸) 조성(組成)에 미치는 영향(影響))

  • Park, Hoon;Park, Hyeon-Suk;Hong, Jong-Uck
    • Applied Biological Chemistry
    • /
    • v.29 no.4
    • /
    • pp.366-371
    • /
    • 1986
  • Fatty acid compositions of Panax ginseng leaves (6 year) grown under different light intensity in field and of the detached leaves exposed to high temperature (20 hours) were investigated by gas chromatography. Linoleic, linolenic, palmitic and palmitoleic acid were the major components(80%) of leaf lipid. The higher the growth light intensity, the lower the percentage of unsaturated acids or bonds, indicating metabolic adaptation to high temperature. Pattern similarity of fatty acid composition was little changed until 20% light but significantly different at 30%, suggesting 20% as limitation light intensity. The close similarity of fatty acid composition between the loaves grown under 30% light and the one at harvest rises uncertainty between adaptation to high temperature and senescence. Total fatty acid content decreased with the increase of light intensity. Short term high temperature $(25^{\circ}C\;or\;35^{\circ}C)$ increased total fatty acid content, unsaturated acid percentage and insignificant difference in pattern similarity of composition.

  • PDF

Inorganic Nanoparticles for Near-infrared-II Fluorescence Imaging (근적외선-II 형광 이미징을 위한 무기 나노입자)

  • Park, Yong Il
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.17-27
    • /
    • 2022
  • Fluorescence imaging is widely used to image cells or small animals due to its high temporal and spatial resolution. Because conventional fluorescence imaging uses visible light, the penetration depth of light within the tissue is low, phototoxicity may occur due to visible light, and the detection sensitivity is lowered due to interference by background autofluorescence. In order to overcome this limitation, long-wavelength light should be used, and fluorescence imaging using near-infrared-I (NIR-I) in the region of 700~900 nm has been developed. To further improve imaging quality, researchers are interested in using a longer wavelength light, near-infrared-II (NIR-II) ranging from 1000 to 1700 nm. In the NIR-II region, light scattering is further minimized, and the penetration depth of light in the tissue is improved up to about 10 mm, and autofluorescence of the tissue is reduced, enabling high sensitivity and resolution fluorescence imaging. In this review, among various NIR-II fluorescence imaging probes, inorganic nanoparticle-based probes with excellent photostability and easily tunable emission wavelength were described, focusing on single-walled carbon nanotubes, quantum dots, and lanthanide nanoparticles.

An Overview of Magnetohydrodynamic Ship Propulsion with Superconducting Magnets

  • Kong, Yeong-Kyung
    • Journal of Energy Engineering
    • /
    • v.2 no.2
    • /
    • pp.231-236
    • /
    • 1993
  • The feasibility of Magnetohydrodynamic(MHD) Ship Propulsion using Superconduction Magnets is reviewed in light of relent advances in high-temperature superconducting. The propulsion using a screw propeller in the noise reduction has it's own limitation. The epochal noiseless MHD propulsion method which does not have this disadvantage is studying nowadays. The subject of a marine MHD as propulsion has been examined before and was found to be interesting because of relatively low magnetic flux densities. It is demonstrated that the MHD propulsion is technically interesting with high magnetic flux density. The development of large-scale magnets using the high-temperature superconductor now under development could make it practical to construct submersibles for high-speed and silent operation.

  • PDF

A study on speckle size and measurable limitations in laser speckle interferometry method (레이저 스페클간섭법에 있어서 스페클크기와 측정 한계에 관한 연구)

  • 윤성운
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1996
  • The high coherence of laser beam has made it possible to observe interference effects even in the light scattered from rough surfaces. That's why, when object with a scattering surface is illuminated with laser light, we do see a speckled appearance due to random interference. This sort of unique property of laser speckle has bruht into existence the new noncontaciting techniques such as speckle metrology method of measuring deformation, displacement, and vibration etc of objects with high optical sensitivity. The measurable range of speckle metrology especially used to measure in -plane information, however, is limited by some factors, the so-called strain, rotation tilt of surface and out of displacement perpendicular to the plane of analysis This restrictions severly limits the measurable range of speckle metrology by causing the decorrelation of speckle patterns. It is the purpose of this paper to give a survey on the measurable limitation of speckle photography method that is one of speckle metrology. Namely we will discuss the mutual relationships and problems of each limitations adding the restriction on the largest and smallest displacement measurable with speckle methods.

  • PDF

Relationship of Optical Density and Wavelength on Light Source for Activated Sludge Concentration (활성슬러지 농도에 따른 광학밀도와 광원파장의 상관관계)

  • Kim, Do-Han;Lee, Chang-Han;Wang, Bo-Kwon;Suh, Jung-Ho;Song, Seung-Koo
    • KSBB Journal
    • /
    • v.25 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • In this study, we developed a comprehensive correlation for better prediction of the activated sludge concentration in the relationship between measurement of optical density by the Beer's law and sludge properties. Effects of activated sludge properties, which are sludge types and anaerobic storage time, show that absorbance deviation for sludge properties decreased on wavelength of light source near to 950 nm. We also developed a method to measure limitation with non-linear correlation on the measurement of high concentration by the Beer's law using a double layer probe cell and empirical equations.

CURING REACTION OF THE LIGHT CURED FLOWABLE COMPOSITE RESINS THROUGH THE ENDODONTIC TRANSLUCENT FIBER POST (투명 fiber 포스트를 통한 광중합형 접착레진의 중합 반응)

  • Ahn Seok;Park Sang-Won;Yang Hong-So;Vang Mong-Sook;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the efficacy and substitute possibility of a newly developed flowable composite resins as a luting cement for translucent fiber post. Material & Method: Two kinds of 12 mm translucent fiber Post (D.T. Light-Post (Bisco, USA) and FRC Postec (Ivoclar vivadent, Liechtenstein) was inserted into the teflon mold (7 mm diameter, 9 mm long) and Filtek-Flow (3M ESPE. USA), a light activated flowable composite resin, was polymerized for 60 seconds through the post. Also, the post was cut from the tip to 9 mm, 6 mm, 3 mm, and Filtek-Flow was light cured according to each length. For comparison, 60 seconds light-cured and 24 hours self-cured two dual cured resin cement (Duo-cement (Bisco, USA) and 2 Panavia-F (Kuraray, Japan)) samples were prepared as control group. Also cavities (1 mm in width, 1 mm in depth and 12 mm in length) were prepared using acrylic plate and aluminum bar, and flowable composite resin was flied and light cured by the diffused light from the fiber post's side wall. The degree of polymerization was measured according to the distance from curing light using Vickers' hardness test. Result: Within the limitation of this study, the following conclusions were drawn: 1. Vickers' hardness of light cured dual cured resin cement and flowable composite resin decreased from Panavia-F, Filtek-Flow and Duo-cement accordingly (p<0.05). In the dual curing resin cement, light curing performed group showed higher surface hardness value than self cured only group (p<0.05). 2. Surface hardness ratio (light cured through fiber post /directly light cured) of D.T. Light-Post using Filtek-Flow showed about 70% in the 6 mm deep and about 50% in the 12 mm deep FRC Postec showed only 40% of surface hardness ratio. 3. Surface hardness ratio by diffused light from the post's side wall showed about 50% at 6 mm and 9 mm deep, and about 40% at 12 mm deep in D.T. Light-Post. However, FRC Postec showed about 40% at 6 mm deep, and almost no polymerization in 9 mm and 12 mm deep.

Silicon transporter genes of Fragilariopsis cylindrus (Bacillariophyceae) are differentially expressed during the progression of cell cycle synchronized by Si or light

  • Oh, Han Sang;Lee, Sung-eun;Han, Chae-seong;Kim, Joon;Nam, Onyou;Seo, Seungbeom;Chang, Kwang Suk;Jin, EonSeon;Hwang, Yong-sic
    • ALGAE
    • /
    • v.33 no.2
    • /
    • pp.191-203
    • /
    • 2018
  • Fragilariopsis cylindrus is one of the most successful psychrophiles in the Southern Ocean. To investigate the molecular mechanism of biomineralization in this species, we attempted to synchronize F. cylindrus growth, since new cell wall formation is tightly coupled to the cell division process. Nutrient limitation analysis showed that F. cylindrus cultures rapidly stopped growing when deprived of silicate or light, while growth continued to a certain extent in the absence of nitrate. Flow cytometry analysis indicated that deprivation of either silicate or light could effectively arrest the cell cycle of this diatom species at the G1 phase, suggesting that synchrony can be established using either factor. Fluorescence labeling of new cell walls was faintly detectable as early as approximately 6 h after silicon repletion or light irradiation, and labeling was markedly intensified by 18 h. It is revealed that the synthesis of girdle bands begins before valve synthesis in this species, with active valve synthesis occurring during the G2 / M phase. Expression profiling revealed that selective member(s) of the F. cylindrus SIT genes (FcSIT) respond to silicate and light, with a different set of genes being responsive to each factor. The Si / light double depletion experiments demonstrated that expression of one FcSIT gene is possibly correlated to transition to G2 / M phase of the cell cycle, when the valve is actively formed.

A Study on High Speed Visible Light Communication System Using Non-orthogonal Multiple Modulation Scheme (비직교 다중변조 방식을 이용한 고속 가시광통신 시스템에 대한 연구)

  • Han, Doo-Hee;Lee, Kyu-Jin
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.2
    • /
    • pp.32-38
    • /
    • 2020
  • In this paper, we analyze the modulation scheme for high speed transmission in visible light communication system, and study non-orthogonal multiplexing, dimming level and transmission power ratio. Conventional visible light communication has a disadvantage in that it is difficult to multi-transmit to increase the transmission speed. Multi-transmission technique is necessary for high-speed transmission at the transmitter. Since general visible light communication has a limitation in multiple transmission, various researches for high-speed transmission have been conducted. In order to solve this problem, this paper proposes a multiple modulation scheme for high-speed visible light communication using non-orthogonal multiplex transmission scheme and a future research direction.

The effect of thickness and translucency of polymer-infiltrated ceramic-network material on degree of conversion of resin cements

  • Barutcigil, Kubilay;Buyukkaplan, Ulviye Sebnem
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • PURPOSE. The aim of the present study was to determine the degree of conversion of light- and dual-cured resin cements used in the cementation of all-ceramic restorations under different thicknesses of translucent (T) and high-translucent (HT) polymer-infiltrated ceramic-network (PICN) material. MATERIALS AND METHODS. T and HT PICN blocks were prepared at 0.5, 1.0, 1.5, and 2.0 mm thicknesses (n=80). Resin cement samples were prepared with a diameter of 6 mm and a thickness of 100 ㎛. Light-cured resin cement was polymerized for 30 seconds, and dual-cure resin cement was polymerized for 20 seconds (n=180). Fourier transform infrared spectroscopy (FTIR) was used for degree of conversion measurements. The obtained data were analyzed with ANOVA and Tukey HSD, and independent t-test. RESULTS. As a result of FTIR analysis, the degree of conversion of the light-cured resin cement prepared under 1.5- and 2.0-mm-thick T and HT ceramics was found to be lower than that of the control group. Regarding the degree of conversion of the dual-cured resin cement group, there was no significant difference from the control group. CONCLUSION. Within the limitation of present study, it can be concluded that using of dual cure resin cement can be suggested for cementation of PICN material, especially for thicknesses of 1.5 mm and above.

Comparative analysis of the flexural strength of provisional restorative resins using a digital light processing printer according to the post-curing method (디지털 광원 처리 프린터로 제작된 임시수복용 레진의 후경화 기계에 따른 굴곡강도 연구)

  • Park, Young-Dae;Kang, Wol
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.341-347
    • /
    • 2020
  • Purpose: This study aimed to evaluate the effect of post-curing method on the flexural strength of provisional restorative resins produced by a digital light processing printer. Methods: A total of 20 specimens were produced, with a length of 64 mm, width of 10 mm, and thickness of 3.3 mm using a digital light processing printer. Two types of provisional restorative resins made with different post-curing methods were investigated and divided into conventional and vacuum groups. For the flexural strength test, each group was prepared by each method according to ISO 10477, and the flexural strength was measured with a universal testing machine. For statistical analysis, data were analyzed by independent t-test and Mann-Whitney U test. Results: The flexural strengths of the conventional and vacuum groups were 151.89 MPa and 131.94 MPa, respectively, showing a statistically significant difference (p<0.05). Conclusion: Within the limitation of this study, provisional restorative resins produced with vacuum demonstrated lower flexural strength than those produced with conventional postcuring method.