• Title/Summary/Keyword: light field camera

Search Result 125, Processing Time 0.035 seconds

Direct Observation of Crack Tip Stress Field Using the Mechanoluminescence of SrAl2O4:(Eu,Dy,Nd) (SrAl2O4(Eu,Dy,Nd) 압광체를 이용한 균열첨단에서의 응력장 가시화 연구)

  • 김지식;손기선
    • Transactions of Materials Processing
    • /
    • v.12 no.5
    • /
    • pp.493-497
    • /
    • 2003
  • The present investigation aims at visualizing the crack tip stress field using a mechanoluminescence material. The well known compound $SrAl_2O_4$:$Eu^{2+}$ was adopted as a mechanolurninescence material. Two more trivalent rare-earth elements such as Dy and Nd were taken into consideration as codopants to provide the appropriate trap levels. Samples of a variety of compositions were prepared by varing $Eu^{2+}$, $Dy^{3+}$, and $Nd^{3+}$ doping contents, for which the combinatorial chemistry method was used. In order to search for the optimum composition for the highest mechanoluminescence, the luminescence induced by a compressive device including a CCD camera. In parallel, a compact tension specimen was prepared by mixing the luminescence powders of optimum composition and epoxy resin. Crack initiation from the mechanically machined sharp note tip and its growth during loading were found to be associated with the extent of light emission from $SrAl_2O_4$.

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Progress report on CQUEAN (Camera for QUasars in EArly uNiverse)

  • Park, Won-Kee;Kim, Eun-Bin;Choi, Chang-Su;Lim, Ju-Hee;Kim, Jin-Oung;Jeong, Hyeon-Ju;Oh, Hee-Young;Pak, Soo-Jong;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.38.2-38.2
    • /
    • 2010
  • We report the current status of CQUEAN (Camera for QUasars in EArly uNiverse) development. CQUEAN is an optical CCD camera which uses a 1024*1024 pixel deep-depletion CCD. It has an enhanced QE than conventional CCD at wavelength band around 1${\mu}m$, thus it will be an efficient tool for observation of quasars at z > 7. It will be attached to the 2.1m telescope at McDonald Observatory, USA. A telescope interface containing a focal reducer is being designed to secure a larger field of view at the cassegrain focus of 2.1m telescope. Instrument control software will be written with python on linux platform. We are carrying out lab tests to investigate the characteristics of the system components in order to maximize the observational efficiency. Preliminary results of the tests will be presented. CQUEAN is expected to see the first light during summer season of 2010.

  • PDF

Characteristics of lightning impulse breakdowns in inhomogeneous $SF_6$ gas gap (불평등전장에서 $SF_6$ 기체의 뇌임펄스 절연파괴특성)

  • Lee, B.H.;Choi, H.S.;Oh, S.K.;Li, F.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1921-1923
    • /
    • 2004
  • V-p characteristics and the discharge luminous characteristics in inhomogeneous $SF_6$ gas gap under the positive and negative lightning impulse voltages are presented. The test gap was composed of the plane-to-plane with a needle-shaped protrusion. The applied voltage and the predischarge current were measured by the electric field sensor and the shunt of 50 ${\Omega}$, respectively. The light emission signals were observed by a photomultiplier tube, and a high-speed camera. In a consequence, the dielectric strengths of $SF_6$ gas gap under positive lightning impulse voltages were independent of the gas pressure. In the presence of the positive polarity, the branches of discharge channel were created and the directions of the discharge paths were random. On the other hands, the discharge paths of the negative polarity were more thicker and brighter.

  • PDF

Design and Development of Sprinkler Control System Utilizing Mobile with IoT

  • Kang, Tae-Sun;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.212-217
    • /
    • 2020
  • We studied on the design of a sprinkler control system that communicates with the administrator's mobile through a wireless communication network and a sprinkler unit that sprays water on the vegetation area. This sprinkler control system consists of a communication module that receives an operation signal for the operation of the sprinkler unit from the administrator's mobile, and a control module that controls the sprinkler unit according to the operation signal received through the communication module. It is also designed to control sprinkler units by measuring temperature, humidity, light intensities, vibration and field images in the vegetation area in real time through sensors and camera for each of them and comparing them with established limit criteria. The sprinkler allows the administrator to control the sprinkler more easily because the administrator operates the sprinkler through the mobile from a distance, and emergency situations occur and can respond quickly.

Internal flow characteristics inside an automobile HVAC according to temperature operation mode (온도조절 모드에 따른 차량용 공조장치 내부 유동특성)

  • Ji, Ho-Seong;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.687-688
    • /
    • 2008
  • Air flow of inside automobile HVAC module has been visualized using a high-resolution PIV technique with varying the temperature operation mode. The PIV system consists of a 2-head Nd:YAG laser(125 mJ), a high-resolution CCD camera(2K x 2K), optics and a synchronizer. A real automobile HVAC module was used directly with slight modification for clear optical windows. Some parts of the HVAC module casing were replaced with transparent windows for capturing flow images with laser light sheet beam illumination. Time-averaged velocity field were measured in three temperature control modes. Flow characteristics of the air-conditioned air flow in the automobile HVAC system were evaluated.

  • PDF

Study on Extraction of the Center Point of Steam Generator Tubes (증기발생기 세관의 중심좌표추출에 대한 연구)

  • 조재완;김창회;서용칠;최영수;김승호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.263-266
    • /
    • 2002
  • This paper describes extraction procedure for the center coordinates of steam generator tubes of Youngkwang NPP #6, which are arrayed in triangular patterns. Steam generator tube images taken with wide field-of-view lens and low-light lamp mounted on a ccd camera tend to have low contrast, because steam generator is sealed and poorly illuminated. The extraction procedures consists of two steps. The first step is to process the region with superior contrast in entire image of steam generator tubes and to extract the center points. Using the extracted coordinates in the first step and the geometrical array characteristics of tubes lined up in regular triangle forms, the central points of the rest region with low contrast are estimated. The straight lines from center point of a tube to neighbour points in horizontal and 60, 120$^{\circ}$ degree directions are derived. The intersections of straight line In horizontal direction and slant line in regular triangle direction are selected as the center coordinates of steam generator tubes. The Chi-square interpolation method is used to determine the line's coefficients in horizontal and regular triangle direction.

  • PDF

Study on the Welding Mode Transition Phenomena in Monitoring Plasma-MIG Hybrid Welding (Plasma-MIG 하이브리드 용접에서 용적 이행모드 현상 모니터링에 대한 연구)

  • Lee, Jong Jung;Park, Young Whan
    • Journal of Welding and Joining
    • /
    • v.35 no.3
    • /
    • pp.75-81
    • /
    • 2017
  • Recently in the welding field, the establishment of unmanned and automated systems are rapidly developing. Accurate interpretation of the welding phenomenon is applied a number of monitoring systems. In this paper, butt welding (6t) type I using Plasma-MIG welding was carried out. And we evaluated characteristics of the Al-5083 aluminium alloy in Plasma-MIG hybrid welding. Process variables including the plasma current, MIG voltage, wire feeding rate and the welding speed were used. Butt welding was conducted 1 pass. Argon gas was used as the protective gas that results from the experiment were able to achieve full penetration. In addition to monitoring the welding process occurring during MIG welding current, welding votage and Plasma current, voltage were collected in real time, the photodiode and CCD cameras observing the phenomenon that the welding is in progress were measured using a quantity of light.

Classification of Surface Defects on Steel Strip by KNN Classifier (KNN 분류기에 의한 강판 표면 결함의 분류)

  • Kim C.H.;Choi S.H.;Joo W.J.;Kim K.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.379-383
    • /
    • 2005
  • This paper proposes a new steel strip surface inspection system. The system acquires bright and dark field images of defects by using a stroboscopic IR LED light and area camera system and the defect images are preprocessed and segmented in real time for feature extraction. 4113 defect samples of cold roll steel strips are used to develop KNN (k-Nearest Neighbor) classifier which classifies the defects into 8 different types. The developed KNN classifier demonstrates about 85% classifying performance which is considered very plausible result.

  • PDF

Design of the Filter Exchange Mechanism for Schmidt Telescope

  • Ji, Tae-Geun;Park, Woojin;Han, Jimin;Kim, Dohoon;Lim, Gu;Jeong, Mankeun;Im, Myungshin;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.67.3-68
    • /
    • 2020
  • A prime focus telescope, e.g., Schmidt telescope, has advantages especially for a wide field of view survey in astronomy. In this optical configuration, the camera is placed in front of the primary mirror. Since the installation of a typical filter wheel to the prime focus telescope causes serious obscuration of the incoming light, a customized filter device is required for high sensitivity images. In this poster, we present a new filter exchange mechanism, which can host four filters moving along quadrant directions. We plan to install this on the Celestron 36 cm Rowe-Ackermann Schmidt Astrograph (RASA 36) located at El Sause Observatory in Chile.

  • PDF