• 제목/요약/키워드: life testing

검색결과 1,288건 처리시간 0.023초

모드해석을 통한 마운트 공진회피 설계 (Design for Resonance Avoidance of Mount Through the Modal Analysis)

  • 이종명;유현탁;박규진;최현철;최병근
    • 한국소음진동공학회논문집
    • /
    • 제25권7호
    • /
    • pp.481-486
    • /
    • 2015
  • This paper provides how to solve the problems analytically and experimentally that occur for testing the water injection pump under development. First of all, water injection pump, based on shaft system dynamic analysis, is verified by measuring the behavior of the shaft system. After the water injection pump is measured, the structural resonances which can cause excessive noise, degradation the equipment life and malfunction are found. Therefore, by changing the structural design, the reso- nance should be avoided. Application of the design variables to the experimentally resonance avoid- ance is difficult. So analytically, with application of the design variables, the design will be changed with mode analysis using FEM.

고장력 강판의 초음파 피로시험 (Ultrasonic Fatigue Test for a High Strength Steel Plate)

  • 염현호;정용찬;김차영;강기영;이문구;홍민성;전용호
    • 한국생산제조학회지
    • /
    • 제24권6호
    • /
    • pp.589-593
    • /
    • 2015
  • The demand of high cycle fatigue behavior on plate material is increasing because of its various applications. However, the high-cycle fatigue life data of the plate material is very rare compared to the rod material. Thus, in this study, a plate specimen is designed for the ultrasonic fatigue test because it is time efficient as compared to the conventional fatigue test. To apply the ultrasonic fatigue test, the specimen design is required to resonate at 20 kHz. Therefore, the dynamic elastic modulus was determined by measuring the resonance frequency with a piezoelectric element and laser doppler vibrometer (LDV). As a result, the plate specimen is designed and demonstrated using the ultrasonic fatigue testing machine. The ultrasonic fatigue test results were compared with the hydraulic fatigue test results.

In Vivo Screening for Biocontrol Agents (BCAs) against Streptomyces scabiei Causing Potato Common Scab

  • Lee, Hyang-Burm;Cho, Jong-Wun;Park, Dong-Jin;Li, Chang-Tian;Ko, Young-Hwan;Song, Jeong-Heub;Koh, Jeong-Sam;Kim, Bum-Joon;Kim, Chang-Jin
    • The Plant Pathology Journal
    • /
    • 제20권2호
    • /
    • pp.110-114
    • /
    • 2004
  • Through in vitro screening for biocontrol agents (BCAs) against Streptomyces scabiei causing potato (Solanum tuberosum) common scab, 19 streptomycete and 17 fungal isolates with antagonistic activity were selected as BCA candidates. For the selection of BCA candidates which are highly resistant to 10 kinds of antibiotics or pesticides, chemical susceptibility testing was initially performed in vitro. A remarkable degree of variation in susceptibility to antibiotics or pesticides was observed among the isolates tested. Streptomycete A020645 isolate was highly resistant to all the tested chemicals except neomycin up to 5,000 ppm. On the other hand, out of 36 antagonistic microbes subjected to in vivo pot tests using cultivar Daejima, four streptomycete isolates namely, A020645, A010321, A010564, and A020973, showed high antagonistic activity with >60% and 55% control value, respectively, and high chemical resistance to 10 kinds of chemicals. Therefore, these isolates were selected as potential BCAs for the control of potato common scab.

현장 데이터를 이용한 연성포장용 피로 공용성 예측모델 검정 (Calibration of Fatigue Performance Prediction Model for Flexible Pavements Using Field Data)

  • 김낙석
    • 한국재난정보학회 논문집
    • /
    • 제8권3호
    • /
    • pp.234-241
    • /
    • 2012
  • 본 연구의 주 목적은 다층 구조를 가진 아스팔트 포장체의 피로균열에 대한 공용성 예측모델을 검정하는 것이다. 그러나, 검정 인자는 목표로 하는 예측모델, 시험법 및 시험중 하중이력에 따라 차이가 있을 수 있다. 본 연구에서 수행된 다양한 현장 조사에 의하면, 연성포장의 피로공용성은 교통하중뿐만 아니라 포장체의 완성후 경과기간에 영향을 받는 것으로 나타났다. 이에 따른 각각의 교통하중과 경과기간에 대한 가중치가 본 연구에서 제시되었다. 또한, 기 발표된 피로 예측모델을 바탕으로 실내와 현장조사를 통하여 얻어진 피로균열 데이터의 상호 상관관계를 분석하여 피로 예측모델에 대한 검정 인자가 개발되었다.

Applications of fiber optic sensors for structural health monitoring

  • Kesavan, K.;Ravisankar, K.;Parivallal, S.;Sreeshylam, P.
    • Smart Structures and Systems
    • /
    • 제1권4호
    • /
    • pp.355-368
    • /
    • 2005
  • Large and complex structures are being built now-a-days and, they are required to be functional even under extreme loading and environmental conditions. In order to meet the safety and maintenance demands, there is a need to build sensors integrated structural system, which can sense and provide necessary information about the structural response to complex loading and environment. Sophisticated tools have been developed for the design and construction of civil engineering structures. However, very little has been accomplished in the area of monitoring and rehabilitation. The employment of appropriate sensor is therefore crucial, and efforts must be directed towards non-destructive testing techniques that remain functional throughout the life of the structure. Fiber optic sensors are emerging as a superior non-destructive tool for evaluating the health of civil engineering structures. Flexibility, small in size and corrosion resistance of optical fibers allow them to be directly embedded in concrete structures. The inherent advantages of fiber optic sensors over conventional sensors include high resolution, ability to work in difficult environment, immunity from electromagnetic interference, large band width of signal, low noise and high sensitivity. This paper brings out the potential and current status of technology of fiber optic sensors for civil engineering applications. The importance of employing fiber optic sensors for health monitoring of civil engineering structures has been highlighted. Details of laboratory studies carried out on fiber optic strain sensors to assess their suitability for civil engineering applications are also covered.

Water-Side Oxide Layer Thickness Measurement of the Irradiated PWR Fuel Rod by NDT Method

  • Park, Kwang-June;Park, Yoon-Kyu;Kim, Eun-Ka
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.680-686
    • /
    • 1995
  • It has been known that water-side corrosion of fuel rods in nuclear reactor is accompanied with the loss of metallic wall thickness and pickup of hydrogen. This corrosion is one of the important limiting factors ill the operating life of fuel rods. In connection with the fuel cladding corrosion, a device to measure the water-side oxide layer thickness by means of the eddy-current method without destructing the fuel rod was developed by KAERI. The device was installed on the multi-function testing bench in the nondestructive test hot-cell and its calibration was carried out successfully for the standard rod attached with plastic thin films whose thicknesses are predetermined. It shows good precision within about 10% error. And a PWR fuel rod, one of the J-44 assembly discharged from Kori nuclear power plant Unit-2, has been selected for oxide layer thickness measurements. With the result of data analysis, it appeared that the oxide layer thicknesses of Zircaloy cladding vary with the length of the fuel rod, and their thicknesses were compared with those of the destructive test results to confirm the real thicknesses.

  • PDF

의치상용 연성 이장재에 대한 mono-poly의 효과 (THE EFFECTS OF MONO-POLY ON THE SOFT DENTURE LINERS)

  • 허지현;진태호;조혜원
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.484-491
    • /
    • 2000
  • Soft denture liners or conditioners may be valuable therapeutic materials. The life of these liners is short and varies, but it can be extended by the use of a mono-poly(polymethyl methacrylate coating material). This study determined whether coating three temporary soft denture liners with mono-poly affected the resiliency of soft liners, and evaluated the ability of mono-poly to prevent water absorption and alcohol loss from the underlying soft liners. $20{\times}12mm$ cylindrical specimens of Coe-Soft, Soft-Liner, Coe-Comfort soft lining materials were made and divided into two groups of mono-poly uncoated(control) and mono-poly coated specimens. Specimens were immersed in water and compressed on an instron universal testing machine and weighed at initial, 24 hours, 1 week, 2 weeks, and 4 weeks. Resiliency was determined by measuring the energy absorbed by the soft liners when stressed to a specific yield point. Mono-poly coating significantly increased the resiliency of the Soft-Liner, but had no effect on the other soft liners. Among the 3 soft liners, Soft-Liner showed the hightest resiliency and modulus of elasticity. The weight loss in Soft-Liner was the least among the 3 liners, and the weight loss in Coe-Soft was decreased by monopoly coating.

  • PDF

청년층의 경제적 합리성으로 본 희망자녀수와 출산시기 : '저출산트랩'가설을 중심으로 (Testing the Economic Rationality Hypothesis of the Low Fertility Trap Among Korean Youths)

  • 유계숙
    • 가정과삶의질연구
    • /
    • 제31권3호
    • /
    • pp.141-151
    • /
    • 2013
  • The purpose of this study is to test the economic rationality hypothesis of the low fertility trap among 412 college students at 13 private universities located in Seoul. The respondents were requested to complete the self-administered questionnaire, and the hierarchical multiple regression analyses were performed for analyzing the data. The major findings of this study were as follows: First, the students' views on the prospects for their future employability were 54.6% for big business, 64.51% for medium-sized business, and 49.63% for public sector. In the most employable job, the mean desired monthly salary was 3,505,400 won, while the mean expected monthly salary 2,753,600 won. Second, hierarchical regression analyses revealed that the family income in parental home was positively related to youths' consumption aspirations. Finally, the gap between youths' consumption aspirations and their expected income was negatively related to their desired number of children, while not significantly related to their planned age of first child birth. Thus, the low fertility trap hypothesis was supported in terms of birth rate drop, but not supported in terms of childbearing postponement. The implications of the study results are discussed.

결혼이주여성의 임신과 산후 적응 요구 측정도구 개발 (Development of a Scale to Assess Immigrant Women's Needs for Pregnancy and Postpartum Adaptation)

  • 김경원;정금희
    • 여성건강간호학회지
    • /
    • 제19권4호
    • /
    • pp.242-253
    • /
    • 2013
  • Purpose: The purpose of this study was to develop a scale to assess immigrant women's needs for pregnancy and postpartum adaptation and to test the reliability and validity of the scale. Methods: To construct scale items, critical issues and difficulties associated with pregnancy and postpartum adaptation of immigrant women were identified and categorized through a literature review. Fifty-two scale items were constructed, and data for validity and reliability testing was collected with a questionnaire survey from 367 immigrant women. Data were analyzed with descriptive statistics, factor analysis, and reliability coefficients. Results: The final measurement scale to assess immigrant women's pregnancy and postpartum adaptation consisted of 48 items and 7 factors (adaptation to daily activity during pregnancy, cross-cultural understanding and personal respect, understanding of the process of pregnancy and delivery, baby rearing and family support, physical and emotional adaptation after childbirth, nutrition during pregnancy, and sexual life adaptation). The seven factors accounted for 64.26% of the variance, and Cronbach's ${\alpha}$ was .96. Conclusion: The scale developed by this study is a reliable and valid instrument and can be used to assess needs of pregnancy and postpartum adaptation and can be utilized in providing nursing interventions for immigrant women.

가속화 시험을 통한 페놀폼 단열재의 장기성능 비교분석에 관한 연구 (Study on Long-term Performance of Phenolic Foam Insulation through Accelerated Aging Test)

  • 김진희;김상명;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제40권2호
    • /
    • pp.11-23
    • /
    • 2020
  • The application of the high-performance insulation materials for buildings seems to be an essential measure for reducing energy use in buildings. Phenolic foam is a readily available insulation material with thermal conductivity of about 0.018 to 0.020 W/(mK). It has the advantage of higher thermal resistance and better fire resistance compared to other conventional building insulation materials. Insulation material used for building envelope is regarded as one of the decisive factors for building's energy load. Furthermore, the degradation of its thermal performance over time increasingly affects the building's energy use demand. Generally, the life span of conventionally built buildings is expected to be more than 50 years, so the long-term performance of insulation materials is critical. This paper aims to evaluate the long-term performance of phenolic form boards through an accelerated aging test. The tests were conducted according to BS EN 13166 and KS M ISO 11561. Based on the results of the accelerated aging test, the thermal performance variation of the material was analyzed, and then its aged value after 25 years was computed. Also, the characteristics of the phenolic foam board's long-term performance were also examined based on the standard testing methods adopted.