• Title/Summary/Keyword: level of detector

Search Result 506, Processing Time 0.023 seconds

Development of Multiwire Proportional Counter for Measurement of Environmental-level Alpha Particles (환경준위 알파입자측정을 위한 다중선 비례계수기 개발(I))

  • Oh, Pil Jae;Park, Tae Soon;Lee, Min Kie;Kim, Kyung Hwa
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.262-269
    • /
    • 1996
  • The muiltiwire proportional counter for the measurement of low-level and environmental $\alpha$ particles emitting nuclides was developed. External dimension of the devloped multiwire proportional counter is $350{\times}290{\times}30mm$ and the sensitivity area is $250{\times}200mm$. The wall material of the detector was selected the stainless steel to prevent the deformation by external impact and to obtain minimum background. The anode and cathode wires were used the stainless steel material of diameter $50{\mu}m$. The spacing of each wires are 10.0mm, 5.0mm and the numbers of total wire are 21, 42 lines, respectively. The multiwire proportional counter was designed that the measurement source is placed within the detector to prevent the wall absorption effect and the efficiency variation by various source heights. The characteristics of the developed detector have been investigated to obtain the plateau, operating voltage, background, counting efficiency, position sensitivity and energy resolution etc. For the $^{241}Am$ nuclide, the calculated LLD(Lower Limit of Detection) is 5.0mBq/L which is lower than 40mBq/L of recommended LLD value by ISO(International Organization for Standardization).

  • PDF

Analysis of 226Ra in the Groundwater Using the Gamma-ray Spectroscopy (감마선 분광법을 이용한 지하수 중의 226Ra 분석)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The measurement of radium ($^{226}Ra$) in the groundwater was established using ${\gamma}$-ray spectroscopy without sample preparation. The background interference by air borne radon daughter nuclides was reduced by $N_2$ gas flow into the counting chamber. Leakage of radon gas produced in the radioactive equilibrium with radium and its daughter nuclides was prevented by use of the air-tighted aluminium container. We investigated the effect of air layer in the counting container. Radioactivity variation due to emanation of radon into the air layer was within the counting error range 5%. When the nitrogen gas was flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of airborne radon was decreased and detection limit was decreased to 0.02 Bq/L. The detection limit of detector was lower than 0.74 Bq/L, the $^{226}Ra$ Maximum Contaminant Level (MCL) in the groundwater proposed by US Environmental Protection Agency (EPA). It was confirmed that $^{226}Ra$ radioactivity in the groundwater could be determined by the ${\gamma}$-ray spectroscopy.

A STUDY ON THE GENERATION OF EO STANDARD IMAGE PRODUCTS: SPOT

  • JUNG HYUNG-SUP;KANG MYUNG-HO;LEE YONG-WOONG;LEE HO-NAM;WON JOONG-SUN
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.216-219
    • /
    • 2004
  • In this study, the concept and techniques to generate the level lA, lB and 2A image products have been reviewed. In particular, radiometric and geometric corrections and bands registration used to generate level lA, lB and 2A products have been focused in this study. Radiometric correction is performed to take into account radiometric gain and offset calculated by compensating the detector response non-uniformity. And, in order to compensate satellite altitude, attitude, skew effects, earth rotation and earth curvature, some geometric parameters for geometric corrections are computed and applied. Bands registration process using the matching function between a geometry, which is called 'reference geometry', and another one which is corresponds to the image to be registered is applied to images in case of multi-spectral imaging mode. In order to generate level-lA image products, a simple radiometric processing is applied to a level-0 image. Level-lB image has the same radiometry correction as a level-lA image, but is also issued from some geometric corrections in order to compensate skew effects, Earth rotation effects and spectral misregistration. Level-2A image is generated using some geo-referencing parameters computed by ephemeris data, orbit attitudes and sensor angles. Level lA image is tested by visual analysis. The difference between distances calculated level 1 B image and distances of real coordinate is tested. Level 2A image is tested Using checking points.

  • PDF

Evaluation of Residual Pesticides in Fresh Ginseng Collected in Seoul

  • Kim, Tae-Rang;Park, Ki-Hwan;Jang, Mi-Ra;Choi, Young-Hee;Kim, Eun-Hee;Choi, Chae-Man;Park, Sung-Kyu;Yu, In-Sil;Hwang, In-Sook;Han, Ki-Young;Kim, Moo-Sang;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • This study was performed to analyze 48 kinds of pesticide residues using gas chromatography (GC)/nitrogen phosphorous detector, GC/micro electron capture detector, GC/mass selective detector, and high performance liquid chromatograph/diode array detector in 186 fresh ginseng samples collected in the Seoul area from 2010 to 2011. Fresh ginseng dietary intakes were estimated using the data from the 2009 Korea National Health and Nutrition examination survey. Residual pesticides were detected in 79 samples (42.5%) with eight different fungicides. Only 20 samples (10.8%) exceeded the maximum residue limits (MRLs) for pesticides registered by the Korea Food & Drug Administration. Among them, tolclofos-methyl residues (10.2%) exceeded the MRL for fresh ginseng in 18 ginseng seedlings and one of the two-year old fresh ginseng plants, and the residual level in just one ginseng seedling violated the MRL for pyrimethanil. The results showed that residual pesticides levels in marketable fresh ginseng around Seoul were relatively safe. The percent acceptable daily intake (%ADI) was calculated using pesticide residues in fresh ginseng and dietary intakes of fresh ginseng. The risk caused by pesticide residues in fresh ginseng was very low.

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

Development of the Pulse Tube Cryocooler for Infrared Detector (적외선 검출기용 맥동관 극저온 냉동기 기술개발)

  • Yeom, Hankil;Park, Seoung-Je;Hong, Hong-Ju;Ko, Junseok;In, Sehwan;Kim, Hyo-Bong
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.4
    • /
    • pp.241-248
    • /
    • 2015
  • Most of the Stirling cryocoolers used for infrared detector cooling in domestic is imported. Because the cooler has a high price, short life and poor durability, demand for the coolers continues steadily. However, the cooler is highly related to defense and space technology, technology transfer or co-development with the countries having experties in cooler design is very limited. The pulse tube cooler to be developed in this study is such that the mechanical piston in low temperature actuating part is replaced by the gas piston and linear compressor is adopted, which results in low vibration, long life and better durability. It is expected that development of the pulse tube cooler will not only improve our technology to the level of advanced countries, but also enhance the skills in designing and manufacturing of the infrared detector.

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF

Effect of Capsaicin on L-Ascorbic Acid Level in Various Tissues and Its Urinary Excretion in Rats

  • Yu, Rina;Kurata, Tadao
    • Preventive Nutrition and Food Science
    • /
    • v.1 no.1
    • /
    • pp.69-74
    • /
    • 1996
  • Capsaicin(CAP) is a pungent ingredient of hot pepper that has been used as a spicy food additive, pre-servative, and medicine. In this study, the effect of CAP on L-ascorbic acid(AsA)level in various tissues as well as its urinary excretion. and drug-metabolizing enzyme activity in rats were investigated. Rats fed AsA-deficient diets for 17days were injected intraperitoneally with 1mg of CAP in 0.5ml of ethanol-Tween 80-saline(20 :10 : 70, v/v/v). Control rats received the equal volume of the same solution without CAP. Urine was collected for 3 day after the CAP injection, and after 5 days tissues were removed; their AsA contents were measured by high performance liquid chromatography combined with and electrochemical detector. In addition, hepatic microsomal ethoxyresorfin O-deethylase(EROD) activity as measured. Urinary AsA excretion changed significantly following CAP injection. One and two days after CAP injection, the urinary AsA increased 2-and 3-fold in the CAP injected group, compared to the control, but the contents of adrenal glands and brain were lower than those of the control Dehydroascorbic acid contents in adrenal glands of the CAP injected group were higher than that of the control These results suggested that a single large dose of CAP could temporarily cause the redistribution of AsA in tissues accompanying by its urinary excretion, by affecting probably a biological system including mixed function oxygenase system(MFOS)

  • PDF

Counting Strategies in Radioactivity Measurement for the Monitoring and Screening (방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략)

  • Seo, Kyung-Won
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • One of the important things in low level radioactivity measurement is determination of the optimized counting time. Counting strategy has to be established, in order to count the radioactivity of the sample by condition of optimized measurement. There were three kinds of counting strategies in this report ; about fixed time, about fixed count, to compared sample, background, and reference level. The best of them was satisfied rendition to give about condition of instrument and process, as an example, efficiency of detector, counter capacity, maximum and average background count rate of counter, reference level and limit of derision and detection, etc. Therefore, we can decide the optimized counting time in the screening and monitoring. And we can save the time for courting the sample of course the data of count will be counted by optimized accuracy finally, in rountine measurement of radioactivity these strategies will be used available.

  • PDF

Concept Design of Fire Safety Module for SV20 Service in the Korean e-Navigation System

  • Kim, Byeol;Moon, Serng-Bae;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.42 no.5
    • /
    • pp.323-330
    • /
    • 2018
  • The Korean e-Navigation system is a Korean approach to correspond with implementation of IMO e-Navigation. It provides five services, among them SV20 service, a ship remote monitoring system that collects and processes sensor information related to fire, navigation, and seakeeping performance safety. The system also detects abnormal conditions such as fires, capsizing, sinking, navigation equipment failure during navigation, and calculates the safety index and determines the emergency level. According to emergency level, it provides appropriate emergency response guidance for the onboard operator. The fire safety module is composed of three sub-modules; each module is the safety index sub-module, the emergency level determination sub-module and emergency response guidance sub-module. In this study, operational concept of the fire safety module in SV20 service is explained, and fire safety assessment factors are estimated, to calculate the fire safety index. Fire assessment factors included 'Fire detector position factor,' 'Smoke diffusion rate factor,' and 'Fire-fighting facilities factor.'