• Title/Summary/Keyword: length measurement

Search Result 2,201, Processing Time 0.029 seconds

Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions (UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사)

  • Choi, Wonei;Lee, Hanlim;Choi, Chuluong;Lee, Yangwon;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.155-165
    • /
    • 2020
  • In this present study, the sensitivity of O4 Air Mass Factor (AMF) to Aerosol Peak Height (APH) has been investigated using radiative transfer model according to various parameters(wavelength (340 nm and 477 nm), aerosol type (smoke, dust, sulfate), aerosol optical depth (AOD), surface reflectance, solar zenith angle, and viewing zenith angle). In general, it was found that O4 AMF at 477 nm is more sensitive to APH than that at 340 nm and is stably retrieved with low spectral fitting error in Differential Optical Absorption Spectroscopy (DOAS) analysis. In high AOD condition, sensitivity of O4 AMF on APH tends to increase. O4 AMF at 340 nm decreased with increasing solar zenith angle. This dependency isthought to be induced by the decrease in length of the light path where O4 absorption occurs due to the shielding effect caused by Rayleigh and Mie scattering at high solar zenith angles above 40°. At 477 nm, as the solar zenith angle increased, multiple scattering caused by Rayleigh and Mie scattering partly leads to the increase of O4 AMF in nonlinear function. Based on synthetic radiance, APHs have been retrieved using O4 AMF. Additionally, the effect of AOD uncertainty on APH retrieval error has been investigated. Among three aerosol types, APH retrieval for sulfate type is found to have the largest APH retrieval error due to uncertainty of AOD. In the case of dust aerosol, it was found that the influence of AOD uncertainty is negligible. It indicates that aerosol types affect APH retrieval error since absorption scattering characteristics of each aerosol type are various.

Performance Evaluation of Fabric Sensors for Movement-monitoring Smart Clothing: Based on the Experiment on a Dummy (동작 모니터링 스마트 의류를 위한 직물 센서의 성능 평가: 더미 실험을 중심으로)

  • Cho, Hyun-Seung;Park, Sun-Hyeong;Kang, Da-Hye;Lee, Kang-Hwi;Kang, Seung-Jin;Han, Bo-Ram;Oh, Jung-Hoon;Lee, Hae-Dong;Lee, Joo-Hyeon;Lee, Jeong-Whan
    • Science of Emotion and Sensibility
    • /
    • v.18 no.4
    • /
    • pp.25-34
    • /
    • 2015
  • TThis study explored the requirement of fabric sensor that can measure the motion of the joint effectively by measuring and analyzing the variation in electric resistance of a sensor in accordance with bending and stretching motion of the arm by the implementation of a motion sensor utilizing conductive fabric. For this purpose, on both sides of two kinds of knitted fabric, namely 'L' fabric and 'W' fabric Single Wall Carbon Nano-Tube(SWCNT) was coated, fabric sensor was developed by finishing them in a variety of ways, and the sensor was attached to the arm band. The fabric sensor consisted of total 48 cases, namely background fabric for coating, the method of sensor attachment, the number of layer of sensors, the length of sensor, and the width of sensor. The performance of fabric motion sensors in terms of a dummy arm, that is, a Con-Trex MJ with 48 arm bands around it was evaluated. For each arm band, a total of 48, fastened around the dummy arm, it was adjusted to repeat the bending and stretching at the frequency : 0.5Hz, ROM : $20^{\circ}{\sim}120^{\circ}$, the voltage was recorded for each case after conducting three sets of repeat measurement for a total of 48 cases. As a result of the experiment, and as a consequences of the evaluation and analysis of the voltage based on the uniformity of the base line of the peak-to-peak voltage(Vp-p), the uniformity of Vp-p within the same set, and the uniformity of the Vp-p among three sets, the fabric sensors that have been configured in SWCNT coated 'L' fabric / welding / two layers / $50{\times}5mm$, $50{\times}10mm$, $100{\times}10mm$, and SWCNT coated 'W' fabric / welding / two layers / $50{\times}10mm$ exhibited the most uniform and stable signal value within 5% of the total variation rate. Through all these results of the experiment, it was confirmed that SWCNT coated fabric was suitable for a sensor that can measure the human limb operation when it was implemented as a fabric sensor in a variety of forms, and the optimal sensor types were identified.

A Study on the Equations of Estimating the Leaf Area of Broad-Leaf Species in Mt. Jiri (지리산(智異山) 주요(主要) 활엽수종(闊葉樹種)의 엽면적(葉面積) 추정식(推定式)에 대(對)한 연구(硏究))

  • Kim, Si Kyung;Lee, Kyeong Hack
    • Journal of Korean Society of Forest Science
    • /
    • v.70 no.1
    • /
    • pp.103-108
    • /
    • 1985
  • This paper is concerned with estimating equations of leaf area(A) obtained from linear measurements - leaf length(L) and leaf width(W) - on the leaves of 13 species composing a natural mixed stand in Mt. Jiri. This method is known to be rapid and non-destructive in estimating leaf area. The equation of A=bLW is frequently used in rough and rapid estimation. Each species in this study has its own coefficient b according to its geometrical leaf shape. The range of coefficients of 13 species was 0.579 to 0.717. This means that the relationship A=2/3LW is suitable to most broad leaf species in a natural mixed stand in Mt. Jiri. When more precise estimation of leaf area is needed, full regression equation is used. In this study, the form of ${\log}A=b_0+b_1{\log}LW$ was the most precise estimation equation in 8 species. In addition to this, the form of $A=b_0+b_1LW$ and $A=b_0+b_1L^2+b_2W^2$ were founded to be suitable for estimation of leaf area. In comparision of these two forms, the determination coefficient were about the same, but the F-value of the former was greater than that of the latter. Therefore, the use of the former seems to be more reliable and practical.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Expression of CsRCI2s by NaCl stress reduces water and sodium ion permeation through CsPIP2;1 in Camelina sativa L.

  • Kim, Hyun-Sung;Lim, Hyun-Gyu;Ahn, Sung-Ju
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.194-194
    • /
    • 2017
  • Camelina (Camelina sativa L.) is a potential bio-energy crop that has short life cycle about 90 days and contains high amount of unsaturated fatty acid which is adequate to bio-diesel production. Enhancing environmental stress tolerance is a main issue to increase not only crop productivity but also big mass production. CsRCI2s (Rare Cold Inducible 2) are cold and salt stress related protein that localized at plasma membrane (PM) and assume to be membrane potential regulation factor. These proteins can be divide into C-terminal tail (CsRCI2D/E/F/G) or no-tail group (CsRCI2A/B/C/H). However, function of CsRCI2s are less understood. In this study, physiological responses and functional characterization of CsRCI2s of Camelina under salt stress were analyzed. Full-length CsRCI2s (A/B/E/F) and CsPIP2;1 sequences were confirmed from Camelina genome browser. Physiological investigations were carried out using one- or four-week-old Camelina under NaCl stress with dose and time dependent manner. Transcriptional changes of CsRCI2A/B/E/F and CsPIP2;1 were determined using qRT-PCR in one-week-old Camelina seedlings treated with NaCl. Translational changes of CsRCI2E and CsPIP2;1 were confirmed with western-blot using the antibodies. Water transport activity and membrane potential measurement were observed by cRNA injected Xenopus laevis oocyte. As results, root growth rate and physiological parameters such as stomatal conductance, chlorophyll fluorescence, and electrolyte leakage showed significant inhibition in 100 and 150 mM NaCl. Transcriptional level of CsPIP2;1 did not changed but CsRCI2s were significantly increased by NaCl concentration, however, no-tail type CsRCI2A and CsRCI2B increased earlier than tail type CsRCI2E and CsRCI2F. Translational changes of CsPIP2;1 was constitutively maintained under NaCl stress. But, accumulation of CsRCI2E significantly increased by NaCl stress. CsPIP2;1 and CsRCI2A/B/E/F co-expressed Xenopus laevis oocyte showed decreased water transport activity as 61.84, 60.30, 62.91 and 76.51 % at CsRCI2A, CsRCI2B, CsRCI2E and CsRCI2F co-expression when compare with single expression of CsPIP2;1, respectively. Moreover, oocyte membrane potential was significantly hyperpolarized by co-expression of CsRCI2s. However, higher hyperpolarized level was observed in tail-type CsRCI2E and CsRCI2F than others, especially, CsRCI2E showed highest level. It means transport of $Na^+$ ion into cell is negatively regulated by expression of CsRCI2s, and, function of C-terminal tail is might be related with $Na^+$ ion influx. In conclusion, accumulation of NaCl-induced CsRCI2 proteins are related with $Na^+$ ion exclusion and prevent water loss by CsPIP2;1 under NaCl stress.

  • PDF

Studies on the Effect of Cation on the Activity at the 5th Instar Larvae of Bombyx mori (5령유충의 배맥관운동에 대한 양이온의 영향에 관한 연구)

  • 윤종관;사기언
    • Journal of Sericultural and Entomological Science
    • /
    • v.18 no.2
    • /
    • pp.89-93
    • /
    • 1976
  • The physiological saline solution for animals is known as Ringer's solution which is used for keeping the function of cold blooded vertebrate animals. Primaily the saline solution is used for the purpose of perfusion experiment in frogs. Later the saline solution is applied in several kinds of animals including human being with satisfactory results. However, this saline solution was introduced to silkworm and it was found that the result was not as successful as in the case of other animals and human being. Normally, in the case of silkworm, the physiological saline solution is prepared in order to maintain the normal function of separated organs and tissues. To this end, the saline solution is adjusted to contain the certain amount and strength of ions, osmosis pressure and hydrogen concentration. The most of cases, the physiological saline solution should be prepared so that the constituent of the solution be the same with the blood selium and body fluid. The hydrogen concentration in the ion element of the saline solution is adjustable by adding Na$\^$+/, K$\^$+/, Ca$\^$++/, Mg$\^$++/ which are followed by adding of buffer solution such as NaHCO$_3$and NaH$_2$PO$_4$. Determination of optimum concentration of cation in the physiological saline solution, and the optimum mixing rate of more than two kinds of cations are based on the movement of dorsal vessel in the silkworm larvae. The optimum concentration of cations in the solution is prepared by adding NaCl solution which is under zero point. However, this solution was further added with the different concentration of KCl and CaCl$_2$. By dropping the prepared solution on the 5th larvae, the effects of solution was measured. The measurement was done by observation of movement' of dorsal vessel and its time length, and the number of pulses. According to the experiment, it was found that when only NaCl solution was applied, the number of pulses is increased for a moment, and the pulse stopped after one hour or so. When KCl solution was added the time of pulse was prolonged and in the contrast, the number of pulses was slow down. If KCl and CaCl$_2$solutions are added the time of pulse was further prolonged. Even though the adding of KCl and CaCl$_2$are found to be effectible, the correlation between the concentration of solution and the movement of dorsal vessel was not observed. However, it was same in the case of adding Ca$\^$++/ or K$\^$+/. It was found that when Mg$\^$++/ was added to dorsal vessel the number of the pulses was not decreased although the prolonged time pulse was observed.

  • PDF

The Correlation of Dyspnea and Radiologic Quantity in Patients with COPD (만성폐쇄성폐질환 환자에서 호흡곤란과 영상학적 정량과의 상관관계)

  • Jung, Eun Jung;Kim, Yang Ki;Lee, Young Mok;Kim, Ki-Up;Uh, Soo-Taek;Kim, Yong Hoon;Kim, Do Jin;Park, Choon Sik;Hwang, Jung Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.4
    • /
    • pp.288-294
    • /
    • 2009
  • Background: A lung hyperinflation, or air trapping, caused by expiratory flow-limitation contributes to dyspnea in patients with chronic obstructive pulmonary disease (COPD). Forced expiratory volume in 1 second ($FEV_1$) has served as an important diagnostic measurement of COPD, but does not correlate with patient-centered outcomes such as dyspnea. Therefore, this study was performed to investigate the role of radiologic quantity in evaluating the dyspnea in patients with COPD by measuring lung hyperinflation in chest x-ray and high resolution chest tomography (HRCT). Methods: Fifty patients with COPD were enrolled in this study. Their subjective dyspnea score (modified Borg scale dyspnea index), spirometry, and lung volume were measured. Simultaneous hyperinflations of chest x-ray score ("chest score") and degree of emphysema of HRCT ("HRCT score") were measured. The "chest score" were composed of lung length, retrosternal space width, and height of the arc of the diaphragm and "HRCT score" were composed of severity and extent of emphysema. Results: The mean age of patients was 69 years old and their mean $FEV_1$ was 51.7%. The Borg score significantly correlated with parameters of spirometry and lung volume, including FVC, $FEV_1$, $FEV_1$/FVC, RV, RV/TLC, and DLCO. The Borg score correlated well with "HRCT score", but did not correlate with "chest score". Also, the Borg scale correlates inversely with body mass index. Conclusion: The quantity of emphysema on chest HRCT may serve as an objective marker of dyspnea in patients with COPD.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

A study on the Logical Reclassification of Parcel Service Tariffs (택배요금기준의 합리적 재설정에 관한 연구)

  • Cho, Yoon-Sung;Lee, Tae-Hwee
    • Journal of Distribution Science
    • /
    • v.10 no.5
    • /
    • pp.45-55
    • /
    • 2012
  • In Korea, the parcel delivery service was launched officially in 1992, and the market has grown to 13.2 billion units, or 3.5 trillion won, as of 2011. The service companies accept small packages under 30 kg and deliver them on the next day in most domestic areas. This service plays an important role in business and personal activities. The parcel service companies have themselves designed the tariff for the delivery service based on two criteria: weight and the sum of three side lengths. Further, the tariff is graded in steps of three or four rate structures based on size (small, medium, large, and extra-small). However, the basic freight rate is generally decided according to the cargo's weight or measurement size, and an extra rate is added according to some factors (handling, stowability, liability, and so on). The parcel service tariff adopted by the companies is illogically designed, and this study was carried out to assess the need for redesigning the tariff structure. The cargo volume cannot be logically reflected by three side lengths. For example, two parcels measuring 160 cm based on three side lengths may have different volumes, one measuring 0.152 cbm (53.33 cm × 53.33 cm × 53.34 cm) and the other 0.05 cbm (100 cm × 50 cm × 10 cm). A small package of less than120 cm (sum of three side lengths) may have a volume of as much as 0.064 cbm (40 cm × 40 cm × 40 cm). Sample comparison showed that 17% of medium-size parcels (based on the sum of three side lengths) are small-volume packages, 24% of large-size parcels are small- or medium-volume packages, and 40% of extra-big-size parcels are big- or under-size packages. Therefore, if parcel service companies rate their services for volume cargo based on the three side lengths standard, users may have to pay higher than normal rates, particularly because a large percentage of parcels are volume cargo. According to this study, the average weight per 1 cbm is less than 300 kg. Therefore, users face an increasing risk of paying higher than logical freight charges. Generally, transportation companies are called "public interest enterprises," and parcel service companies operate as postal services. Public interest enterprises must provide the delivery service to all customers without discrimination at a reasonable service level and logical service charges. Therefore, parcels service tariffs must be designed and adopted logically. In this study, freight theories and prior research findings were used to consider the importance of freight rates, and distortion of parcel service rates based on the three side lengths system was verified through regression analysis of a parcel sample and sample comparison. In conclusion, volume sizes based on three side lengths have a higher correlation to the rate level than does the sum of three side lengths. Further, compared to the sum of three side lengths, volume size has a higher correlation to cargo weight, which is the most basic factor determining transportation cost. Therefore, the existing parcel service tariff should be changed to weight- and volume-based rates, and the tariff must be graded in steps of 8 to 10 higher rate structures for a logical freight schedule based on service cost.

  • PDF