• 제목/요약/키워드: length measurement

검색결과 2,195건 처리시간 0.025초

측정 자동화 구축을 위한 투영기의 치수오차 분석에 관한 연구 (A Study on Analysis of Dimensional Error of Projector for Formulations of Measurement Automation)

  • 최지선;김문기
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.114-118
    • /
    • 2021
  • In this research, the dimensional error of the measured specimen according to the measurement method was analyzed for the length, angle, radius of curvature and diameter using a projector which is used in industry. One-way analysis was performed on each data tested 30 times using a statistical technique. Through the experiment, it was found that an error occurred in each data when measuring the length and radius of curvature according to the measurement method, and the null hypothesis that no error occurred when measuring the angle and length was established. Based on this experimental data, the automatic measurement when measuring the projector causes less measurement error, so automatic measurement is recommended when measuring a small product. Also, an optimal measuring method is suggested for securing reliability on formulations of measurement automation.

Measurement of Focal Length for Off-axis Optical Systems

  • Choe, Se-woon;Ryu, Jaemyung
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.402-408
    • /
    • 2021
  • An off-axis system refers to an optical system in which the optical axis and normal vector at the vertex of each surface do not match. The most important specification in an optical system is its focal length. Among the various methods for measuring the focal length, the most suitable method for the off-axis system is the method that adopts magnification. However, head-mounted display (HMD) optics must be measured while considering the virtual image distance, which is not infinity owing to product characteristics. For the virtual image distance, a camera with a focusing function was used. By measuring HMD optics via this magnification method, the error generated in this measurement was 0.68% of the HMD's focal length, which is within the 1%-3% range of the conventionally permitted design error for the focal length allowed at the optical design stage. Therefore, it can be verified that the measurement accuracy of the method proposed in this study is sufficiently feasible in practice.

Machine Vision Technique for Rapid Measurement of Soybean Seed Vigor

  • Lee, Hoonsoo;Huy, Tran Quoc;Park, Eunsoo;Bae, Hyung-Jin;Baek, Insuck;Kim, Moon S.;Mo, Changyeun;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제42권3호
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: Morphological properties of soybean roots are important indicators of the vigor of the seed, which determines the survival rate of the seedlings grown. The current vigor test for soybean seeds is manual measurement with the human eye. This study describes an application of a machine vision technique for rapid measurement of soybean seed vigor to replace the time-consuming and labor-intensive conventional method. Methods: A CCD camera was used to obtain color images of seeds during germination. Image processing techniques were used to obtain root segmentation. The various morphological parameters, such as primary root length, total root length, total surface area, average diameter, and branching points of roots were calculated from a root skeleton image using a customized pixel-based image processing algorithm. Results: The measurement accuracy of the machine vision system ranged from 92.6% to 98.8%, with accuracies of 96.2% for primary root length and 96.4% for total root length, compared to manual measurement. The correlation coefficient for each measurement was 0.999 with a standard error of prediction of 1.16 mm for primary root length and 0.97 mm for total root length. Conclusions: The developed machine vision system showed good performance for the morphological measurement of soybean roots. This image analysis algorithm, combined with a simple color camera, can be used as an alternative to the conventional seed vigor test method.

Al/Epoxy 이종재 접합 계면의 초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficients on Interfaces of Al/Epoxy Bonded Dissimilar Materials)

  • 박성일;정남용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1109-1114
    • /
    • 2003
  • The initial crack often occurs on the bonded interface and it is the general cause of the interface fracture. It is very significant to establish the measurement method of interfacial crack by applying the ultrasonic technology into the interface of bonded dissimilar materials. In this paper, the interfacial crack length was measured by ultrasonic attenuation coefficient in the Al/Epoxy bonded dissimilar materials of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental and Ripling's equation measurement of compliance. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the experimental results, a measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

광간섭법을 이용한 변위/길이 측정시스템의 설계 및 해석 (Design and Analysis of Displacement/Length Measuring System Using Laser Interferometry)

  • 김진상;김승철;정성종
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.151-156
    • /
    • 1997
  • A laser measurement system, a modified Michelson interferometer, which can accurately measure high speed length and displacement of servomechanisms by detecting a phase shift in the measurement beam using an optical interference was developed. A frequency stabilized laser source and a 20 fold frequency interpolation and digitizing circuit were applied to the system. The refra- ctive index of the ambient air was calibrated through the Edlens formula. The system achieved a resolution of /40, 16nm, a maximum allow-able measurement speed of 600nm/sec, and a length measure- ment range of 1500 mm. Performance of the system was evaluated on the machining center in short and long length measurements.

  • PDF

사춘기 소녀용 브래지어 개발을 위한 흉부 형태 분석에 관한 연구 (A Study on Breast Shape Analysis for Developing Brassiere of the Girls at Adolescence)

  • 이경화;임정란
    • 복식
    • /
    • 제40권
    • /
    • pp.81-93
    • /
    • 1998
  • It is necessary to research shape of the breast of girls at adolescence for developing well-fit brassiers. 313 participants reside in Chonju and Kunsan were gathered for body measurement. The conclusion of this study can be summarized as follows. 1) The Analysis of Body Shape by Measurement. Comparing Age GroupⅠ(aged 10 to 12)' measurement with Age GroupⅡ(aged 13 to 15)', Each items has statistical significance. Two groups differed in the length, girth, depth, width items. 2) Factor Analysis of Body Measurement (1) Age GroupⅠ'characteristics were categorized Three Factor : Breast size and breast apex length. Breast volume, Length of the Breast part. (2) Age GroupⅡ' characteristics consist of four factors, which are named as breast size and its jut (first factor), breast volume (second factor), contour of breast profile & its jut (third factor), shoulder length (fourth factor). 3) Characteristics of Breast Shape. (1) Breast shapes of Age GroupⅠ are classified into three types. Types 1 is a protruded and more voluminous shape. Type 2 is the most voluminous and breast fatness is highest. Type 3 is the smallest and flat shape growing now. (2) Breast shapes of Age GroupⅡ are also classified into three types. Type 1 is the longest in length and middle in fatness, voluminous in size. Type 2 is the smallest in stature and the slimmest in fatness in breast shape. Type 3 is middle in length, the fattest and the most voluminous in breast.

  • PDF

영상처리기법을 이용한 CCT 시편 균열의 자동관측법에 관한 연구 (The Measurement of the Crack in CCT Specimen Using the Image Processing Techniques)

  • 이현우;문기태;오세종;정병우
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.528-533
    • /
    • 1997
  • In the analysis of fatigue crack propagation behavior, the crack length is one of the most important factors. In the test of crack propagation, compliance method is widely used to detect crack length. The measurement of surface crack length is not so easy with compliance method. In this study, the image processing technique was applied to measure the surface crack length. CCD(Charge-coupled device) camera was used to observe the crack image and the computer program to detect crack length from stored crack image was developed. CCT(Center Cracked Tension) specimen was used to compare the compliance method with the image processing technique. The crack length which detected by the image processing techniques was found to be well consistent with that from the optical measurement.

게이지 블록 간섭계의 선진화 및 완전 자동화 (Advancing the Gauge Block Interferometer and Automating the Gauge Block Calibration)

  • 강주식;김재완;서호성;이원규;김종안
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.547-550
    • /
    • 2005
  • Gauge blocks are the most widely used material measure in length field in industry. The gauge block interferometer, which is the gauge block measuring system, comprises Twyman-Green type interferometer optics and light sources having precisely known wavelengths. This paper describes the work done for advancing the measurement system and automating the measurement process. The advancing of the system was done mainly by exchanging the spectral lamp with the frequency stabilized lasers, and the automation of measurement was achieved by modifying the hardware and developing the automatic measuring software. As the results of this work, the contrast of interferometric fringes of gauge blocks longer than 100 mm s enhanced about 20 times, and the measurement time has reduced down to 50% by automation.

  • PDF

근관치료의 근관장 측정에 관한 연구: 근관치료학 전공 교수 설문 (A survey on working length determination of endodontic treatment)

  • 안혜라;서민석
    • 대한치과의사협회지
    • /
    • 제55권1호
    • /
    • pp.42-52
    • /
    • 2017
  • The purpose of this study is to evaluate the preferred method of root canal length determination and the apical limit for canal instrumentation among endodontic teachers of dental school. A questionnaire on the preferred method of root canal length determination and the apical limit for canal instrumentation was designed and distributed to endodontic teachers of various dental schools. The response rate was 90%. The most preferred method of root canal length determination was Electronic apex locator (EAL)(89%). The most favoured apical limit for canal instrumentation was 0.5 to 1.0 mm short of the radiographic apex(78%). The most preferred method of using EAL was that the working length is taken at 'APEX' mark and then distracted 0.5mm from that length.(41%). When there is no agreement between radiographic measurement and EAL measurement, 74% of respondents chose the length of EAL measurement. The majority of endodontic teachers from Korean dental schools preferred EAL to radiograph method in determining root canal length.

  • PDF

Vision System을 이용한 사출제품의 길이 측정용 시각검사 System 개발 (The Development of Visual Inspection for Length Measurement of Injection Product Using Vision System)

  • J.Y. Kim;B.S. Oh;S. You
    • 한국정밀공학회지
    • /
    • 제14권11호
    • /
    • pp.126-134
    • /
    • 1997
  • In this study, We made visual inspection system using Vision Board. It is consist of an illuminator (a fluorescent lamp), image input device (CCD (Charge-Coupled Device) camera), image processing system(Vision Board(FARAMVB-02)), image output device (video monitor, printer), and a measuring instrument(TELMN1000). Length measurement by visual inspection system make use of 100mm guage block(instead of calculating distance between a camera and a object). It measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measure- ment of a injection. A measuring instrument used to ompare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument with visual inspecion system using length factor of 100mm gauge block. We find that maximum error of length is 0.55mm when it compar with the measuring value of two devices(FARAMVB-02, TELMN1000). Program of visual inspection system is made up Borland C++3.1.

  • PDF