• Title/Summary/Keyword: length measurement

Search Result 2,201, Processing Time 0.047 seconds

Application of slab and plate width measurement using laser distance meter (Laser를 이용한 후물 판재류 및 Slap폭 측정 적용)

  • 최철호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1076-1078
    • /
    • 1996
  • According to ascending needs for quality assurance of plate by customer and automated measurement of dimension for slab, in plate mill, project is on preceeding to install measuring system to measure width, length and camber of slab and plate using laser distance meter. In this document, I will describe not technical point of view but idea of design for installation system.

  • PDF

A Study on the Temperature Accuracy due to Conditions of Thermocouple Installation (열전대의 설치상태에 따른 온도측정 오차에 관한 연구)

  • 선양래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.49-54
    • /
    • 1982
  • In the equipments of industrial plant and marine engine, an exact temperature measurement is indispensable. Temperature measurement errors are induced by electrical and heat errors, and the insufficient immersion length of thermowell exerts an important effect to the haet error. In this paper, the author analyses the relation between temperature errors and the rate of immersion length to outside diameter (L/D) in order to reduce the heat errors.

  • PDF

An Analysis on Treeing in XLPE by means of Image Processing (화상처리에 의한 XLPE의 트리잉 해석)

  • 이재봉;임장섭;정우성;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.122-128
    • /
    • 1994
  • Studies on treeing phenomena have depended on the visual measurement using optical microscope. In the visual measurement, it is difficult to analyze the treeing in real time because voltages are applied discontinuously and impossible to calculate the deterioated area by treeing. Only tree type and length are studied. In this paper, image processing is introduced and voltages are applied continuously. The tree length and area are calculated in real time from tree inception to breakdown. Growing characteristics about tree types are compared for the normalized breakdown time.

Textbook Analysis about Length Estimation and Exploration for an Alternatives (길이 어림과 관련된 교과서 분석 및 대안 모색)

  • Ko, Jung-Hwa
    • Communications of Mathematical Education
    • /
    • v.24 no.3
    • /
    • pp.587-610
    • /
    • 2010
  • This paper investigates the ways for estimation ability improvement in length, which is recently emphasized in measurement area of mathematics education. According to preceding studies, students' length estimation ability is considerably low. Revision curriculum tried to pursue estimation and feeling of massiveness responsive to trends in mathematics education. But, Such efforts are not reflected in textbooks and they are rather weak in the aspect of estimation and feeling of massiveness. This paper analyzes the contents related to length estimation in current textbooks critically and explores an alternatives. This paper is suggestive for textbook development to improve ability to estimate length.

Study of the error chsracteristics in a mirror loss measurement system using an exqonential decay metod (지수감쇠 기법을 이용한 반사경 손실측정 시스템의 오차특성 연구)

  • 조민식
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.77-82
    • /
    • 2001
  • Error characteristics of a mirror loss measurement system using an exponential decay method were studied, with the two samples having about 200-ppm-loss and 30-ppm-loss, respectively. In order to minimize the decay signal deviation from an exponential curve due to cavity length fluctuation, a data average method was tried. The data average method significantly improved the exponential curve fitting error of the decay signal, so that for a 6 decay signal data average the loss measurement error was reduced by about 2.4 times for the 200-ppm-loss mirror and 1.3 times for the 30-ppm-loss mirror compared with a single shot measurement. Day-to-day mirror loss repeatability error for the two samples was investigated. The repeatability error was measured to be about 5% for the 200-ppm-loss mirror and about 26.4% for the 30-ppm-loss mirror. Low decay signal average effect and high repeatability error in the low loss mirror measurement were explained with non-uniform spatial loss distribution of the sample and contamination from the environment, in addition to the error sources of the mirror loss measurement system itself. The influence of cavity length fluctuation and cavity length measurement error on the mirror loss measurement system performance was theoretically calculated. It confirmed that the requirement for the cavity length parameters was not so strict in the mirror loss measurement system of several ppm resolution. ution.

  • PDF

Clothing-ergonomical Analysis Method for the Basic Torso's Pattern Drafting (토르소 원형설계를 위한 피복인간공학적 분석방법)

  • Kim, Hye-Gyeong;Seo, Chu-Yeon;Seok, Eun-Yeong;Gang, Juk-Hyeong;Kim, Ji-Seon;Kim, Hye-Su;Heo, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.109-125
    • /
    • 2000
  • The purpose of this study was to provide basic data for a more functional torso's pattern by analyzing multidimensional anthropometric measurements and the wearing condition. For the functional torso's pattern drafting, the fitness state of basic torso's patterns(4 types) was compared and evaluated from the cross-sectioned overlap maps by $moir{\acute{e}}$ topography. The results were as follows: 1. According to the measurements of four patterns by using the one-dimensional measurement, the amount of ease in girth item for pattern A was the smallest. The ease of clothes was affected by the position of dart, the amount of dart, and the drafting method. 2. As the results of wearing evaluation by $moir{\acute{e}}$ topography method, pattern B had the largest space length for hip part, pattern A, C and D had the largest space length for bust part. Also, in the all measurement items, pattern A had the smallest amount of ease. The space length for bust and waist part of pattern B was smaller than pattern D, but, for abdomen and hip part of pattern B was larger than pattern D. The space length of pattern C was revealed intermediate for all measurement part. 3. The significant difference of space length of each pattern was shown in all parts except bust part(p<.05). The amount of space was affected by the amount of dart, the characteristics of the somatotype, and the drafting method.

  • PDF

Defect Length Measurement using Underwater Camera and A Laser Slit Beam

  • Kim, Young-Hwan;Yoon, Ji-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.746-751
    • /
    • 2003
  • A method of measuring the length of defects on the wall of the spent nuclear fuel pool using the image processing and a laser slit beam is proposed. Since the defect monitoring camera is suspended by a crane and hinged to the crane hook, the camera viewing direction can not be adjusted to the orientation that is exactly perpendicular to the wall. Thus, the image taken by the camera, which is horizontally rotated along the axis of the camera supporting beam, is distorted and thus, the precise length can not be measured. In this paper, by using the LASER slit beam generator, the horizontally rotated angle of the camera is estimated. Once the angle is obtained, the distorted image can be easily reconstructed to the image normal to the wall. The estimation algorithm adopts a 3-dimensional coordinate transformation of the image plane where both the laser slit beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect taken at arbitrary rotated angle can be reconstructed to an image normal to the wall. From the result of a series of experiments, the accuracy of the defect is measured within 0.6 and 1.3 % error bound of real defect size in the air and underwater, respectively under 30 degree of the inclined angle of the laser slit beam generator. Also, the error increases as the inclined angle increases upto 60 degree. Over this angle, the defect length can not be measured since the defect image disappears. The proposed algorithm enables the accurate measurement of the defect length only by using a single camera and a laser slit beam.

  • PDF

Analysis on the Measurement and Shape Classification of the Head and Face for Korean Male Children aged $9{\sim}12$ years ($9{\sim}12$세 남자 아동의 머리와 얼굴 부위 측정 및 유형 분류)

  • Lee Hyun-Min;Choi Hei-Sun;Kim Son-Hee
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.6 s.53
    • /
    • pp.933-944
    • /
    • 2004
  • This study was aimed to provide the fundamental and various measurement data of the head and face for male children. Two hundred forty one male children, aged nine to twelve years, participated for this study. The 31 regions on the head and face of the subjects were directly measured by the expert experimenters. Through factor analysis, the six factors were extracted upon factor scores and those factors comprised $67.47\%$ for the total variances. The first factor was described the general height elements for the mouth and the environs of the mouth. The second factor was described the general height around the nose, forehead and eyes. The third factor was described the height of the ear environs. The forth factor contained the length around the sinciput to the occiput, the head thick and the head circumstance. The fifth factor was described the general width of the outer head and the corner of the eyes. The last factor contained the depth of the mouth and nose. Four clusters as their head and face shape were categorized using six factor scores by cluster analysis. Type 1 was characterized by the shortest head and face width, surface length and girth, and the shorter length of head, but the highest position of chin, philtrum, upper lip. Type 2 was characterized by the shortest head and face length and thickness, and the lowest position of the forehead, eye, nose, mouth, ear environs, but that had wider width of head and face. Type 3 was characterized by the longest and the widest head and face type, and the highest position of the mouth. Type 4 was characterized by longer length of head and face, and the widest head girth and largest head thickness, and the highest position of the forehead, eye, nose environs. And this type had the widest width of nose and mouth, and the longest head surface length.

  • PDF

The Comparative Study between Leg Length Analysis and X-ray on Diagnosis of Pelvic Malpositions - according to Positions and Valuation Bases - (기능성 족지장단분석과 X-ray의 골반변위 진단의 비교 연구 - X-ray 촬영 자세 및 평가 기준에 따라 -)

  • Lee, Jung-Min;Koog, Gil-Ho;Choi, Bo-Mi;Jeong, Hyun-A;Hong, Seo-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.2
    • /
    • pp.169-180
    • /
    • 2010
  • Objectives: This study was carried out to investigate the relationship of leg length analysis and X-ray finding according to positions and valuation bases on diagnosis of pelvic malpositions. Methods: Twenty-two people who get $33.09{\pm}10.73$ as average were evaluated by leg length analysis and X-ray findings. After measuring innominate measurement(IM), femur head line. distance between S2 and posterior superior iliac spine(PSIS). ilium shadow measurement(ISM), major axis of obturator foramen(MaF), minor axis of obturator foramen(MiF) and distance between off centering measurement and symphysis pubis, those were analyzed. Results: 1. In assessment of posterior rotation malposition ilium(PI), it was showed the best coincidence between leg length analysis and X-ray analyzed by 1M in supine position(11 cases, 50.5%). 2. In assessment of inflare, coincidence index between leg length analysis and X-ray were not good($4.00{\pm}3.03$ cases, $18.15{\pm}13.82%$). And leg length analysis were not sensitive. 3. On the whole, coincidence index between leg length analysis and X-ray were not good(best: 1 case, 45.5%; worst: 11 cases, 50.0%). Conclusions: Results form this investigation showed the relationship of leg length analysis and X-ray according 10 positions and valuation bases on diagnosis of pelvic malpositions. This results are expected to contribute to establish method of assessment in diagnosis of pelvic malpositions.

  • PDF