• Title/Summary/Keyword: length measurement

Search Result 2,195, Processing Time 0.026 seconds

Ultrasonic Velocity Measurements of Engineering Plastic Cores by Pulse-echo-overlap Method Using Cross-correlation (다중 반사파 중첩 자료의 상호상관을 이용한 엔지니어링 플라스틱 코어의 초음파속도 측정)

  • Lee, Sang Kyu;Lee, Tae Jong;Kim, Hyoung Chan
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.3
    • /
    • pp.171-179
    • /
    • 2013
  • An automated ultrasonic velocity measurement system adopting pulse-echo-overlap (PEO) method has been constructed, which is known to be a precise and versatile method. It has been applied to velocity measurements for 5 kinds of engineering plastic cores and compared to first arrival picking (FAP) method. Because it needs multiple reflected waves and waves travel at least 4 times longer than FAP, PEO has basic restriction on sample length measurable. Velocities measured by PEO showed slightly lower than that by FAP, which comes from damping and diffusive characteristics of the samples as the wave travels longer distance in PEO. PEO, however, can measure velocities automatically by cross-correlating the first echo to the second or third echo, so that it can exclude the operator-oriented errors. Once measurable, PEO shows essentially higher repeatability and reproducibility than FAP. PEO system can diminish random noises by stacking multiple measurements. If it changes the experimental conditions such as temperature, saturation and so forth, the automated PEO system in this study can be applied to monitoring the velocity changes with respect to the parameter changes.

The Analysis and Field Measurement of Longitudinal Track Forces for Long Railroad Bridges (교량상 궤도축력의 해석 및 실측결과 비교)

  • Kang, Kee Dong;Park, Jong Bang;Kim, In Jae;Park, Dae Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.907-913
    • /
    • 1994
  • The design of railroad bridges differs from road bridges because of the interface between track structure and bridge structure. The track generally consists of Continuous Welded Rail(CWR) which is fixed by fasteners to the sleepers embedded in the ballast. The ballast provides the interface between the track structure and the bridge structure. Large longitudinal forces can develop from the temperature variation in rail and bridge structure. These longitudinal forces are specially important for long bridges because the bridge layout for span length, pier dimensions and arrangement and type of bearings can be governed by these forces. This report provides a comparison of longitudinal track forces determined by analysis and actual measured track forces. In recent practice the longitudinal track force for European railways is analyzed using a finite element analysis method. This method is very time-consuming and requires the detail design of the bridge to be complete. Redesign is required if the design criteria for longitudinal track forces are not satisfied. There is a need to develop a simple analysis method considering the large number of bridge structures and a relatively short design time on the Korean High Speed Rail Project. The analysis results presented herein, based on a simplified analysis, show good agreement with those obtained by finite element analysis, as well as with those measured on an actual track. The proposed analysis method is particularly useful for the preliminary design of bridge structures.

  • PDF

Current Trends and Future-Oriented View of Clinical Measurement Used by Neurological Occupational Therapist (신경계 작업치료사의 평가도구 사용 현황 및 향후 방향)

  • Song, Chiang-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5229-5237
    • /
    • 2012
  • Occupational therapist is required for patient-centered approaches to actively seek the perspectives of patients and their families in clinical settings. The purpose of this study was to investigate the current trends and to suggest future-oriented view of examination and assessment used by neurological occupational therapist in clinical settings. Sixty-six occupational therapists who work in persons with neurological disorders participated in this study. The survey was measured from Seoul and GyeongGi by means of E-mail about commonly used assessment tools and selecting considerations. The participants were 66 neurological occupational therapists. The number of patients by one day was from 10 to 14 persons, and the length of time for initial evaluation was 20-40 minutes per one patient, and reexamination periods was every 1 month or as functional changes were detected. The using tool was not limited only neurological tools, and choice consideration was the reliability and validity of clinical measures. The most frequently used tools for adults were: JHFT for motor function in upper extremity, MMSE-K for cognitive perceptual assessment, MBI for daily activity assessment, and COPM for occupational performance. The most frequently used tools for child were: MVPT for cognitive perceptual assessment and Wee-FIM for daily activity assessment. The results of this study suggest that it is necessary to integrate and associate patient-report, care-giver report, and results of performance-based assessment for estimating plan of care more quality.

GIS Vector Map Compression using Spatial Energy Compaction based on Bin Classification (빈 분류기반 공간에너지집중기법을 이용한 GIS 벡터맵 압축)

  • Jang, Bong-Joo;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.3
    • /
    • pp.15-26
    • /
    • 2012
  • Recently, due to applicability increase of vector data based digital map for geographic information and evolution of geographic measurement techniques, large volumed GIS(geographic information service) services having high resolution and large volumed data are flowing actively. This paper proposed an efficient vector map compression technique using the SEC(spatial energy compaction) based on classified bins for the vector map having 1cm detail and hugh range. We encoded polygon and polyline that are the main objects to express geographic information in the vector map. First, we classified 3 types of bins and allocated the number of bits for each bin using adjacencies among the objects. and then about each classified bin, energy compaction and or pre-defined VLC(variable length coding) were performed according to characteristics of classified bins. Finally, for same target map, while a vector simplification algorithm had about 13%, compression ratio in 1m resolution we confirmed our method having more than 80% encoding efficiencies about original vector map in the 1cm resolution. Also it has not only higher compression ratio but also faster computing speed than present SEC based compression algorithm through experimental results. Moreover, our algorithm presented much more high performances about accuracy and computing power than vector approximation algorithm on same data volume sizes.

Sapphire Based 94 GHz Coplanar Waveguide-to-Rectangular Waveguide Transition Using a Unilateral Fin-line taper (평면형 Fin-line 테이퍼를 이용한 사파이어 기반의 94 GHz CPW-구형 도파관 변환기)

  • Moon, Sung-Woon;Lee, Mun-Kyo;Oh, Jung-Hun;Ko, Dong-Sik;Hwang, In-Seok;Rhee, Jin-Koo;Kim, Sam-Dong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.65-70
    • /
    • 2008
  • We design and fabricate the 94 GHz Coplanar waveguide(CPW)-to-rectangular waveguide transition that is transmits signal smoothly between the CPW, which is a popular transmission line of the planar circuits, and rectangular waveguide for the 94 GHz transceiver system. The proposed transition composed of the unilateral fin-line taper and open type CPW-to-slot-line transition is based on the hard and inflexible sapphire for the flip-chip bonding of the planar MMICs using conventional MMIC technology. We optimize a single section transition to achieve low loss by using an EM field solver of Ansoft's HFSS and fabricate the back- to-back transition that is measured by Anritsu ME7808A Vector Network Analyzer in a frequency range of $85{\sim}105$ GHz. From the measurement and do-embedding CPW with 3 mm length, an insertion and return loss of a single-section transition are 1.7 dB and more an 25 than at 94 GHz, respectively.

Electrical Behavior of the Circuit Screen-printed on Polyimide Substrate with Infrared Radiation Sintering Energy Source (열소결로 제작된 유연기판 인쇄회로의 전기적 거동)

  • Kim, Sang-Woo;Gam, Dong-Gun;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.71-76
    • /
    • 2017
  • The electrical behavior and flexibility of the screen printed Ag circuits were investigated with infrared radiation sintering times and sintering temperatures. Electrical resistivity and radio frequency characteristics were evaluated by using the 4 point probe measurement and the network analyzer by using cascade's probe system, respectively. Electrical resistivity and radio frequency characteristics means that the direct current resistance and signal transmission properties of the printed Ag circuit. Flexibility of the screen printed Ag circuit was evaluated by measuring of electrical behavior during IPC sliding test. Failure mode of the Ag printed circuits was observed by using field emission scanning electron microscope and optical microscope. Electrical resistivity of the Ag circuits screen printed on Pl substrate was rapidly decreased with increasing sintering temperature and durations. The lowest electrical resistivity of Ag printed circuit was up to $3.8{\mu}{\Omega}{\cdot}cm$ at $250^{\circ}C$ for 45 min. The crack length arisen within the printed Ag circuit after $10{\times}10^4$ sliding numbers was 10 times longer than that of after $2.5{\times}10^4$ sliding numbers. Measured insertion loss and calculated insertion loss were in good agreements each other. Insertion loss of the printed Ag circuit was increased with increasing the number of sliding cycle.

Population Ecology of Korean Rose Bitterling, Rhodeus uyekii (Pisces: Acheilognathinae) in the Bongseocheon, Mankyeonggang (River), Korea (만경강 수계 봉서천에 서식하는 각시붕어 Rhodeus uyekii (Pisces: Acheilognathinae)의 개체군 생태)

  • Kim, Hyeong Su;Ko, Jae Geun;Choi, Wung Sun;Park, Jong Young
    • Korean Journal of Ichthyology
    • /
    • v.27 no.2
    • /
    • pp.78-85
    • /
    • 2015
  • Population ecology of Rhodeus uyekii (Pisces: Acheilognathinae) was investigated at the Bongseocheon, Mankyeonggang (River) in Korea, from January to December 2014. It mainly inhabits the slow-flowing waters having mud bottoms. Measurement of the standard length of the population indicated that the following standardization: 24~29 mm are one year old, 30~35 mm are two years old, 36~39 mm are three years old, and >40 mm group are regarded over four years old (October in 2014). The spawning season was from March to June, with water temperatures in the range $11.5{\sim}27.0^{\circ}C$. The sex ratio of female : male was 1 : 0.77. The number of eggs in the ovaries was 104~168 ($mean{\pm}SD$: $124{\pm}18.1$). The size of the matured eggs was 2.8~3.5 ($3.2{\pm}0.15$) mm in the long axis, and 1.4~1.5 ($1.4{\pm}0.03$) mm in the short axis. The eggs were found in Unio douglasiae and the number of eggs, larvae or both was 3~18 ($10.2{\pm}5.0$). Stomach contents were mainly phytoplanktons such as the genera Navicular, Cocconeis, Cymbella (Bacilariophyceae) and Cloniophora (Chlorophyceae).

Measurement and Calculation of Excess Enthalpies for n-Hexane/Alkane series and NaOH/Water/Ethanol System using Isothermal Microcalorimeter (등온 미세열량계를 이용한 n-Hexane-알칸계 이성분 혼합물 및 NaOH/Water/Ethanol계의 과잉 엔탈피 측정 및 계산)

  • Choi, In Kyu;You, Seong-sik
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.660-667
    • /
    • 2017
  • Equilibrium data of the mixture is essential in the design and operation of separation equipment such as distillation or extraction in chemical processes. These equilibrium data can be obtained through experiments or by calculations using the known binary parameters and the thermodynamic models. Generally, to obtain these parameters, phase equilibrium experimental data such as gas-liquid and liquid-liquid are used. In this study, the excess enthalpy of the mixture was measured using the flow type microcalorimeter which is a simpler method than phase equilibria experiments, and the parameters of various theories were obtained by using this data. In order to investigate the relationship between carbon chain length, enthalpy and binary parameters in the alkane system, excess enthalpies for the n-hexane + alkane (n-pentane, n-heptane, n-octane and n-dodecane) were measured at 298.15 K and the banary interaction parameters of Wilson, NRTL, and UNIQUAC were obtained from the experimental data. In addition, we wanted to obtain basic information on the interaction and association phenomena of the system including electrolyte applicable to various fields by using the excess enthalpy experimental data and the existing theory. First, we investigated the excess enthalpy for the NaOH / Water / Ethanol system as a basic experiment and examined the applicability using the electrolyte-NRTL (eNRTL) theory.

Alternative Method of Retrocrural Approach during Celiac Plexus Block Using a Bent Tip Needle

  • An, Ji Won;Choi, Eun Kyeong;Park, Chol Hee;Choi, Jong Bum;Ko, Dong-Kyun;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • v.28 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • Background: This study sought to determine safe ranges of oblique angle, skin entry point and needle length by reviewing computed tomography (CT) scans and to evaluate the usefulness of a bent tip needle during celiac plexus block (CPB). Methods: CT scans of 60 CPB patients were reviewed. Image of the uppermost margin of L2 vertebral body was used to measure the minimal and maximal oblique angles and the distances from the midline to skin puncture point. The imaginary needle trajectory distance was calculated by three-dimensional measurement. When the procedure was performed by using a $10^{\circ}$ bent tip needle under a $20^{\circ}$ oblique X-ray fluoroscopic view, the distance (GF/G'F) from the midline to the actual puncture site was measured. Results: The imaginary safe oblique angle range was $26.4-34.2^{\circ}$ and $27.7-36.0^{\circ}$ on the right and left, respectively. The distance from the midline to skin puncture point was 6.1-7.6 cm on the right and 6.3-7.6 cm on the left. The needle trajectory distance at minimal angle was 9.6-11.6 cm on the right and 9.5-11.5 cm on the left. The distance of GF/G'F was 5.1-6.5 cm and 5.0-6.4 cm on the right and left, respectively. All imaginary parameters were correlated with BMI except for GF/G'F. All complications were mild and transient. Conclusions: We identified safe values of angles and distances using a straight needle. Furthermore, using a bent tip needle under a $20^{\circ}$ oblique fluoroscopic view, we could safely perform CPB with smaller parameter values.

A study on correlations between tongue with skeletal pattern and intermaxillary space in Class II malocclusion adult patients (골격성 II급 성인 부정교합자에서 혀와 두개안면골격 및 악간공간과의 상관관계에 관한 연구)

  • Kang, Hyun-Hee;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.575-587
    • /
    • 1999
  • This study was designed to evaluate the correlations between tongue with skeletal pattern and intermaxillary space in Class II malocclusion adult patients. Craniofacial skeletal pattern was analyzed on the lateral cephalometric radiograph and the subjects were devided two groups by facial ratio, the 30 subjects of hyperdivergent group and the 30 subjects of hypodivergent group. The size and posture of tongue and intermaxillary space were measured on the lateral cephalometric radiograph. These data were statistically analyzed to examine significant differences between both groups and compared the correlation between tongue with skeletal measurements and intermaxillary space in each group. The results of this study were as follows. 1. In comparison of the tongue and intermaxillary space, the measurement of TS/IS showed significantly larger in hyperdivergent group and PIH and IS showed significantly larger in hypodivergent group. There were no statistically significant differences in the measurements of the height and posture of tongue. 2. In correlation between tongue with craniofacial skeletal measurements, the length and height of tongue showed the highest correlation with AFH(anterior facial height) in both groups(p<0.01). And that measurements showed high correlation with PFH(posterior facial height) in hypodivergent group. 3. In both groups, most measurements of tongue showed high correlation with intermaxillary space and the height and space of tongue showed high correlation with AIH and PIH(p<0.01).

  • PDF