• Title/Summary/Keyword: length measurement

Search Result 2,201, Processing Time 0.025 seconds

Firing Test of Core Engine for Pre-cooled Turbojet Engine

  • Taguchi, Hideyuki;Sato, Tetsuya;Kobayashi, Hiroaiki;Kojima, Takayuki;Fukiba, Katsuyoshi;Masaki, Daisaku;Okai, Keiichi;Fujita, Kazuhisa;Hongoh, Motoyuki;Sawai, Shujiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.115-121
    • /
    • 2008
  • A core engine for pre-cooled turbojet engines is designed and its component performances are examined both by CFD analyses and experiments. The engine is designed for a flight demonstration of precooled turbojet engine cycle. The engine uses gas hydrogen as fuel. The external boundary including measurement devices is set within $23cm{\times}23cm$ of rectangular cross section, in order to install the engine downstream of the air intake. The rotation speed is 80000 rpm at design point. Mixed flow compressor is selected to attain high pressure ratio and small diameter by single stage. Reverse type main combustor is selected to reduce the engine diameter and the rotating shaft length. The temperature at main combustor is determined by the temperature limit of non-cooled turbine. High loading turbine is designed to attain high pressure ratio by single stage. The firing test of the core engine is conducted using components of small pre-cooled turbojet engine. Gas hydrogen is injected into the main burner and hot gas is generated to drive the turbine. Air flow rate of the compressor can be modulated by a variable geometry exhaust nozzle, which is connected downstream of the core engine. As a result, 75% rotation speed is attained without hazardous vibration and heat damage. Aerodynamic performances of both compressor and turbine are obtained and evaluated independently.

  • PDF

Effect of Various Lower Extremity Exercises Using the Swiss Ball While Standing on Balance, Muscle Strength, Gait and Fall Efficacy in Stroke Patients: A Pilot Study

  • Lim, Yun-Jeong;Kang, Soon-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.4
    • /
    • pp.202-209
    • /
    • 2021
  • Purpose: This study examined whether various lower extremity exercises using a Swiss ball in the standing position could improve balance, muscle strength, gait, and fall efficacy in stroke patients. Methods: Twenty-one stroke patients were randomly divided into three groups, each with seven participants. For four weeks, experimental group 1 performed various lower extremity exercises using a Swiss ball, while experimental group 2 executed the same exercises without a Swiss ball, and the control group underwent general physical therapy. The subjects' knee extensor muscle strength, balance, gait, and fall efficacy were evaluated before and after the intervention using portable muscle strength measurement, the Berg Balance Scale (BBS), G-walk, and the Korean Falls Efficacy Scale (K-FES). Results: Knee extensor strength increased significantly in all three groups after the intervention; in particular, a significant increase was seen in experimental groups 1 and 2 compared to the control group. Moreover, all three groups had significantly better BBS scores and higher cadence after the intervention; notably, experimental group 1 had better scores and increased cadence than the control group. Additionally, gait speed was significantly increased in the experimental group 1 than in the control group. The step length of the non-affected leg was also significantly higher in the same group. The K-FES score improved significantly in all three groups, but there was no significant difference between the groups. Conclusion: This study suggests that lower extremity exercises with or without a Swiss ball could be effective interventions to improve muscle strength, balance, gait, and fall efficacy in stroke patients.

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

Evaluation of Efficacy of Body Shaper for Senior Women Using 3D Scanned Data (3차원 데이터를 활용하여 시니어를 대상으로 한 바디쉐이퍼의 보정기능성 평가)

  • Kim, Soyoung;Hong, Kyunghi;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.21 no.2
    • /
    • pp.220-230
    • /
    • 2019
  • The Fourth Industrial Revolution has increased studies on observing the cross section by overlapping the clothing worn using 3D human body data. However, there is a lack of studies on the effect of pressure clothing that contracts the shape of the human body. Therefore, this study objectively evaluated the shaping functionality of body shapers using 3D scan and 3D data. Two types of commercial body shapers were selected for this study. The nude body and body wearing body shapers were then scanned. A 3D program evaluated the shaping functionality by overlapping the nude state with the body wearing body shaper A and B respectively. As a result, it was found that the effect of body shapers could be adequately observed according to body parts. The smaller body shaper was shown to have superior shaping capability with the abdomen more affected. Analysis of the horizontal cross section indicated that the waist circumference decreased by 6 cm when wearing body shaper A and decreased by 12cm when wearing body shaper B. The volume of the waist part decreased by 8.6% when wearing body shaper A and by 20.4% when wearing body shaper B. Therefore, it is more effective to compare the objective shaping functionality by body parts using the overlapped 3D scanned data rather than using exterior evaluation or length measurement when wearing clothing that contracts the body shape.

Effectiveness of Patient and Family-Centered Care interventions: A Systematic Review (환자-가족중심 의료서비스의 융합적 성과: 체계적 문헌고찰)

  • Yoo, Ji-Yeon;Ahn, Sung-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.6
    • /
    • pp.365-379
    • /
    • 2019
  • This review aimed to analyze characteristics and performances of patient and family-centered care interventions and evaluate the convergence effectiveness. Randomized controlled trials were searched, selected, data extracted and quality-assessed using the Risk of Bias in 15 databases. Characteristics suggested from 21 studies were provision of information, education, communication and family and friend participation. There were 89 measurement variables of performances. Patient outcome was measured by mortality, length of hospitalization, etc., indicated as significantly improved in 18 studies. This review has provided evidence that patient and family-centered care improved experience and performance of diverse patients, families and health-care providers. There is need to convergence adopt patient and family-centered care and conduct evidence-based studies for improvement of quality of healthcare and patient safety in the future.

A Design of Economic CUSUM Control Chart Incorporating Quality Loss Function (품질손실을 고려한 경제적 CUSUM 관리도)

  • Kim, Jungdae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.203-212
    • /
    • 2018
  • Quality requirements of manufactured products or parts are given in the form of specification limits on the quality characteristics of individual units. If a product is to meet the customer's fitness for use criteria, it should be produced by a process which is stable or repeatable. In other words, it must be capable of operating with little variability around the target value or nominal value of the product's quality characteristic. In order to maintain and improve product quality, we need to apply statistical process control techniques such as histogram, check sheet, Pareto chart, cause and effect diagram, or control charts. Among those techniques, the most important one is control charting. The cumulative sum (CUSUM) control charts have been used in statistical process control (SPC) in industries for monitoring process shifts and supporting online measurement. The objective of this research is to apply Taguchi's quality loss function concept to cost based CUSUM control chart design. In this study, a modified quality loss function was developed to reflect quality loss situation where general quadratic loss curve is not appropriate. This research also provided a methodology for the design of CUSUM charts using Taguchi quality loss function concept based on the minimum cost per hour criterion. The new model differs from previous models in that the model assumes that quality loss is incurred even in the incontrol period. This model was compared with other cost based CUSUM models by Wu and Goel, According to numerical sensitivity analysis, the proposed model results in longer average run length in in-control period compared to the other two models.

Comparison of vertical ground reaction forces between female elderly and young adults during sit-to-stand and gait using the Nintendo Wii Balance Board

  • Lim, Ji Young;Yi, Yoonsil;Jung, Sang Woo;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.4
    • /
    • pp.179-185
    • /
    • 2018
  • Objective: The purpose of this study was to analyze and compare vertical ground reaction forces during sit to stand (STS) and gait between female elderly and young individuals using the Wii Balance Board (WBB). Design: Cross-sectional study. Methods: Fifty-one female elderly people (age: $75.18{\pm}4.60years$), and 13 young people (age: $29.85{\pm}3.69years$) performed the five times STS test and gait respectively on the WBB. We analyzed time (s), vertical peak (%), integral summation (Int_SUM, %), and counter variables (%) in STS and 1st peak (body weight, BW%), 2nd peak (BW%), peak minimum (BW%), time (second), center of pressure (COP) path length (mm), and Int_SUM (BW%) in gait. The independent t-test was used to assess for differences in STS, gait ability, and general characteristics between the female elderly group and young adults group. With the first and last trials excluded, the mean value was obtained from the middle three of the five trials. Results: During STS, Int_SUM and time of young adults were significantly less than of the female elderly subjects. There were no significant differences in peak and counter variables. In gait, all variables (1st peak, 2nd peak, min, time, COP_path, and Int_SUM) showed significant differences between groups (p<0.05). This study demonstrated that the validity of vertical ground reaction forces occurring during STS and gait was significant in female elderly and young adults. Conclusions: Based on the measurement of vertical ground reaction forces in STS and gait using the WBB, it is possible to clinically improve the quality of geriatric physical therapy. Further studies are necessary to examine concurrent validity of elderly patients who have undergone total hip or knee replacement.

The Effect of a Modified Side-Bridge Exercise on the Thickness of Trunk Muscles in Healthy Adults (수정된 측면 교각운동이 정상 성인 몸통근육의 두께에 미치는 영향)

  • Park, Jae-Cheol;Kim, Yong-Nam
    • PNF and Movement
    • /
    • v.19 no.1
    • /
    • pp.127-135
    • /
    • 2021
  • Purpose: The purpose of this study was to determine the effect of the side-bridge exercise on the thicknesses of the external and internal obliques, the transverse abdominis, and the erector spinae, which are some of the trunk muscles of healthy adult males and females. Methods: There were 30 subjects divided into two groups with 15 subjects in the modified side-bridge exercise group and 15 subjects in the bridge exercise group. The changes in each variable were analyzed before the exercise, after three weeks, and after six weeks of exercise using a two-way repeated analysis of variance. The significance level was set at 0.05. When there was any interaction between the time of measurement and each group, a paired t-test was conducted to find the difference within groups and an independent-sample t-test was conducted to find the difference between groups. The significance level for both tests was set at 0.01. Results: There was a significant difference in the external and internal obliques and the erector spinae according to changes over time and the interactions between the time and groups (p < 0.05). However, there was a significant difference in the transverse abdominis only according to the interaction between the length of times (p < 0.05). Conclusion: The study results indicated that the modified side-bridge exercise significantly increased the thickness of the external and internal obliques and the erector spinae. This suggests the usability of the exercise in lumbar stabilization exercises in future studies and clinical fields.

A Finite Memory Structure Smoothing Filter and Its Equivalent Relationship with Existing Filters (유한기억구조 스무딩 필터와 기존 필터와의 등가 관계)

  • Kim, Min Hui;Kim, Pyung Soo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.2
    • /
    • pp.53-58
    • /
    • 2021
  • In this paper, an alternative finite memory structure(FMS) smoothing filter is developed for discrete-time state-space model with a control input. To obtain the FMS smoothing filter, unbiasedness will be required beforehand in addition to a performance criteria of minimum variance. The FMS smoothing filter is obtained by directly solving an optimization problem with the unbiasedness constraint using only finite measurements and inputs on the most recent window. The proposed FMS smoothing filter is shown to have intrinsic good properties such as deadbeat and time-invariance. In addition, the proposed FMS smoothing filter is shown to be equivalent to existing FMS filters according to the delay length between the measurement and the availability of its estimate. Finally, to verify intrinsic robustness of the proposed FMS smoothing filter, computer simulations are performed for a temporary model uncertainty. Simulation results show that the proposed FMS smoothing filter can be better than the standard FMS filter and Kalman filter.

Effects of therapeutic horse-riding program on the walking ability of students with intellectual disabilities

  • Kang, Ok-Deuk
    • Journal of Animal Science and Technology
    • /
    • v.63 no.2
    • /
    • pp.440-452
    • /
    • 2021
  • The purpose of this study was to determine if an 8-week therapeutic riding (TR) program was effective in improving the walking ability of students with intellectual disabilities. Thirteen students diagnosed with intellectual disabilities participated in the TR program. TR sessions were conducted twice a week (30 min per session), with a total of 16 rides taking place over an 8-week period. A gait measurement analyzer was used to measure progress based on a turn test (6-m walking and turning test), walk test (10-m walking), and timed up and go (TUG) test. Measurements were made three times: before horse-riding (P0), after 4 weeks (8 rides) of horse-riding (P1), and after 8 weeks (16 rides) of horse-riding (P2). Data analysis was conducted using SPSS software (ver. 22.0). Descriptive statistics were generated on the general characteristics of the subjects, and the Kolmogorov-Smirnov test was used to verify the normality of the data. Because of the lack of normality, the data were analyzed using a nonparametric method and the significance level was set to 0.05. Measurements of the duration of the forward gait cycle (s) in the turn test and the forward gait speed (m/s) in the walk test indicated improved walking ability after the TR program (p < 0.001); the stride length (% height) also increased significantly (p < 0.05). The walk test revealed a significant effect of the program on the duration of the forward gait cycle (p < 0.05), while there were significant improvements on the left and right of the elaborated strides (p < 0.001). No significant improvement in TUG test performance was observed after the TR program. In this study, an 8-week TR program had positive results on gait. Therefore, further research is merited, where TR programs are likely to improve the walking ability of individuals with intellectual disabilities.