• Title/Summary/Keyword: length measurement

Search Result 2,195, Processing Time 0.036 seconds

Preparation and Characterization of Polyurethane Flame-Retardant Coatings Containing Trichloro Lactone Modified Polyesters (트리클로로 락톤 변성폴리에스테르를 함유한 폴리우레탄 난연도료의 제조 및 난연특성)

  • 정충호;박형진;김성래;우종표;김명수
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.200-208
    • /
    • 2002
  • Two-component polyurethane flame-retardant coatings were prepared by blending trichloro lactone modified polyesters (TAPTS) and isocyanate, Desmodur IL. Polycondensation reaction of trichlorobenzoic acid (TBA) as a flame-retardant component, and adipic acid with trimethylolpropane, polycaprolactone 0201, and 1,4-butanediol gave the corresponding TAPTs. The content of TBA was adjusted from 10 to 30 wt% in our experiment. It was found that various properties of these new flame-retardant coatings were comparable to other non-flame-retardant coatings. We also carried out three different tests for the measurement of flammability of flame -retardant coatings. The results of vertical burning test for the coatings containing more than 20 wt% of TBA were determined as 'no burn'. The results of flammability test for the coatings with 20 and 30 wt% of TBA contents indicated the limiting oxygen index (LOI) values of 25% and 27% respectively, which implied relatively good flame retardancy. They also showed the char length of 3.6-5.2 cm according to $45^{\circ}$ Meckel burner test, which can be classified as the first grade flame-retardant coatings.

Characteristic Study of the Pulse Position on CHON, KWAN and CHUCK Using the Ultrasonic Waves (초음파 분석을 이용한 촌관척 위치별 혈관의 특성연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Ryu, Hyun-Hee;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-117
    • /
    • 2007
  • The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women(22.28${\pm}$2.62 age) considered normal in terms of Body Mass Index(BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value. Results showed there is a statistically significant difference among the variables measured on CHON, KWAN and CHUCK. A difference according to gender was also observed. This explains why an oriental medical doctor can tell the difference in pulses depending on the location of CHON, KWAN and CHUCK. In addition, the difference in pressure between CHON and KWAN was higher than that in pressure between KWAN and CHUCK. The findings explain why oriental medical doctors take pulses by dividing CHON, KWAN and CHUCK in the short length of the three fingers. It can be used to develop a pulse diagnosis device enabling accurate measurement according to the characteristics of blood vessel structure based on where the pulse is taken. Furthermore, the results can be used as basic data for the development of a pulse diagnosis simulator.

  • PDF

Model Tests for Measurement of Lateral Earth Pressure on Retaining Wall with the Relieving Platform Using Jumoonjin Sand (주문진 모래를 이용한 선반식 옹벽의 수평토압 측정 모형시험)

  • Moon, In-Jong;Kim, Byoung-Il;Yoo, Wan-Kyu;Park, Yong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5923-5929
    • /
    • 2013
  • Recently, the retaining wall with the relieving platform has received increasing interests also in Korea in that it can reduce the lateral earth pressure and provide more stability than conventional retaining wall. Previous studies with model tests studies covered only a limited test conditions. In this study, total 15 model tests were performed for various conditions with improved model test apparatus to confirm the effect of decreasing the lateral earth pressure on the retaining wall with the relieving platform. Jumoonjin sand was used for model soil and 2 load cells were used for each 15 layers to measure the lateral earth pressure. Based on the experimental results, the lateral earth pressure of the retaining wall with the relieving platform is less than the that of cantilever wall. The length of the platform and the location of the platform are the key factors influencing the lateral earth pressure.

Prediction of Fatigue Life in 2 Ply Rubber/Cord Laminate (2층 고무/코드 적층판의 피로 수명 예측)

  • 임동진;이윤기;윤희석;김민호
    • Composites Research
    • /
    • v.16 no.3
    • /
    • pp.9-17
    • /
    • 2003
  • In order to simulate the crack connection between cords and the interply crack growth in the belt-layer of real tire, 2 ply rubber/cord laminate specimens with exposed edges were tested in 4~11mm displacement control. Measurement of the crack connection is evaluated when crack reaches the half of the length between 45$^{\circ}$ aligned cords, and the amount of the crack growth is measured by the steel probe method. 2 dimensional analytic modeling was performed to simulate the crack connection between cords at the exposed edges. Also, the theoretical life of the specimens was calculated from the crack connection life between cords(critical value) and from the critical value to the final failure by the use of Tearing energy(T); the strain energy release per unit area of one fracture surface of a crack. Then, theoretical life was compared with those of experiments. The life prediction up to the critical value has about 20% error compared to experimental life, and up to the final failure about 65% error. Therefore, total theoretical life has about 45% error compared to the experimental life, which is conceivable in the case of rubber.

Effects of Elastic Band Resistance Exercise on Improving the Balance Ability in the Elderly (탄력밴드저항운동이 노인의 균형 능력 향상에 미치는 영향)

  • Kim, Geon;Kim, Su-Hyon;Seo, Sam-Ki;Yoon, Hui-Jong;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.2
    • /
    • pp.1-10
    • /
    • 2008
  • Purpose: This study examines the effects of elastic band of resistance exercise for balance control of the elderly. Methods: Thirty of eighty participants in experiment subjects who demonstrated balance-impairment through the use of primary screening tests including the one leg standing test (OLST), functional reach test (FRT) and timed up and go (TUG) were selected as subjects. Fifteen subjects that underwent muscle-strengthening exercise using an elastic band were selected as the exercise group and fifteen subjects were selected as a control group. Subjects undertook a home-based exercise program three times per week for 9 weeks. Muscle strength, functional assessment and a balance test were quantitatively measured before and after the exercise regimen. Results: After muscle strengthening exercises, changes in maximal voluntary isometric contraction (MVIC) showed a significant increase in all of the lower extremity muscles of the exercise group subjects. There were statistically significant differences between the exercise and control groups for changes in the OLST, FRT and TUG, which are functional assessments of balance ability, and changes of the unit path length and circumference area, measurement items of quantitative analysis. In addition, from examining correlations between MVIC, balance ability, it was found that an increase of muscle strength in the hip joint group of muscles among the lower extremity muscles had greater improvement in correlation with balance ability in this elderly population. Conclusion: Resistance exercise using elastic bands had significant effects on muscle strengthening in elderly subjects, with a resultant increase of lower extremity muscle strength with significant improvement of balance ability.

  • PDF

An Assessment of the Excavation Damaged Zone in the KAERI Underground Research Tunnel (원자력연구원 내 지하처분연구시설의 암반 손상대 발생영향 분석)

  • Kim, Jin-Seop;Kwon, Sang-Ki;Cho, Won-Jin
    • Explosives and Blasting
    • /
    • v.27 no.1
    • /
    • pp.21-31
    • /
    • 2009
  • An excavation damaged zone (EDZ) is created by fracturing, excavation or stress redistribution of tunnels. In this zone the mechanical and hydraulic properties of rock are changed, which makes additional cracks and serves as a dominant pathway of groundwater flow. In this study, an assessment on an EDZ size was practiced by the measurement of the deformation modulus at the KAERI underground research tunnel (KURT), and the information was applied to the modelling analysis using FLAC2D software. The EDZ at KURT fell into the range of 0.6~1.8m and the deformation moduli of the EDZ generally correspond to about 40% of intact rock mass. With a consideration of the EDZ in numerical analysis, tunnel displacements increased by about 65% and the maximum principal stress decreased to 58% from the case without EDZ. The plastic zone of the tunnel was enlarged to the crown and invert zones of the tunnel within the range of the length of rock bolts. About 2% of the total tunnel displacement with EDZ was suppressed by the KURT support system. It is anticipated that the investigation of an EDZ can be used as an important and fundamental research for validating the overall performance of a high level waste disposal system.

Comparison of Damping for Steel Tall Buildings by Half Power Bandwidth and Random Decrement Method (철골조 고층건물의 하프파워법과 RD법에 의한 감쇠율 비교)

  • Yoon, Sung-Won;Ju, Young Kyu;Shin, Sang Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.107-115
    • /
    • 2007
  • In this paper, the damping ratios of two methods, namely the half-power bandwidth method and random decrement method from the vibration measurement were examined. Ambient vibration tests were conducted on two steel-framed and one composite tall building ranging from 27 to 36 stories. The performance of the half-power bandwidth method was investigated using four sample sizes, such as 1024, 2048, 4096 and 8192. Damping by the half-power bandwidth method is slightly more overestimated than the random decrement method due to insufficient record length. Damping evaluation by the half-power bandwidth method was found to be enhanced when using the narrower bandwidth with long recorded data.

Abdominal Wall Closure Using Artificial Mesh for Patients with an Open Abdomen (복부개방(Open abdomen) 환자에서 인공막(Artificial Mesh)를 이용한 근막봉합술)

  • Cha, Sung Whan;Shim, Hong Jin;Jang, Ji Young;Lee, Jae Gil
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.172-177
    • /
    • 2012
  • Purpose: After damage control surgery, abdominal wall closure may be impossible due to increased intra-abdominal pressure (IAP), and primary closure may induce abdominal compartment syndrome. The purpose of this study was to investigate changes in the IAP and the feasibility of abdominal wall closure using artificial mesh. Methods: From July 2010 to July 2011, 8 patients with intra-abdominal hypertension underwent abdominal wall closure using artificial mesh. Medical data such as demographics, diagnosis, operation, IAP, postoperative complications, mortality and length of hospital stays were collected and reviewed, retrospectively. One patient was excluded because of inadequate measurement of the IAP. Results: Seven patients, 4 males and 3 females, were enrolled, and the mean age was 54.1 years old. Causes of operations were six traumatic abdominal injuries and one intra-abdominal infection. The IAP was reduced from $21.9{\pm}6.6mmHg$ before opening the abdomen to $15.1{\pm}7.1mmHg$ after fascial closure. Fascial closure was done on $14.9{\pm}17.5$ days after the first operation. The mean lengths of the hospital and the intensive care unit (ICU) stays were 49.6 days and 29.7 days respectively. Operations were performed $3.1{\pm}1.5$ times in all patients. Two patients expired, and one was transferred in a moribund state. Three patients suffered from complications, such as retroperitoneal abscesses, enterocutaneous fistulas, and bleeding that was related to the negative pressure wound therapy. Conclusion: After abdominal wall closure using artificial mesh, intra-abdominal pressure was well controlled, and abdominal compartment syndrome does not occur. When the abdominal wall in patients who have intra-abdominal hypertension is closed, artificial mesh may be useful for maintaining a lower abdominal pressure. However, when negative pressure wound therapy is used, the possibility of serious complications must be kept in mind.

Delayed Presentation of a Post-traumatic Mesenteric Arteriovenous Fistula: A Case Report (외상 후 지연성으로 발생한 장간막 동정맥루: 증례보고)

  • Cho, Jayun;Jung, Heekyung;Kim, Hyung-Kee;Lim, Kyoung Hoon;Chun, Jae Min;Huh, Seung;Park, Jinyoung
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.248-251
    • /
    • 2013
  • Introduction: A post-traumatic mesenteric arteriovenous fistula (AVF) is extremely rare. Case Report: A previously healthy 26-year-old male was injured with an abdominal stab wound. Computed tomography (CT) showed liver injury, pancreas injury and a retropancreatic hematoma. We performed the hemostasis of the bleeding due to the liver injury, a distal pancreatectomy with splenectomy and evacuation of the retropancreatic hematoma. On the 5th postoperative day, an abdominal bruit and thrill was detected. CT and angiography showed an AVF between the superior mesenteric artery (SMA) and the inferior mesenteric vein with early enhancement of the portal vein (PV). The point of the AVF was about 4 cm from the SMA's orifice. After an emergent laparotomy and inframesocolic approach, the isolation of the SMA was performed by dissection and ligation of adjacent mesenteric tissues which was about 6 cm length from the nearby SMA orifice, preserving the major side branches of the SMA, because the exact point of the AVF could not be identified despite the shunt flow in the PV being audible during an intraoperative hand-held Doppler-shift measurement. After that, the shunt flow could not be detected by using an intraoperative hand-held Doppler-shift measuring device. CT two and a half months later showed no AVF. There were no major complications during a 19-month follow-up period. Conclusion: Early management of a post-traumatic mesenteric AVF is essential to avoid complications such as hemorrhage, congestive heart failure and portal hypertension.

Input Impedance Calculation of the Power Line Communication System (전력선 통신 시스템의 입력 임피던스 계산)

  • Chun, Dong-wan;Lee, Jin-taek;Park, Young-Jin;Kim, Kwan-Ho;Shin, Chull-Chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.983-990
    • /
    • 2004
  • In this paper, we calculated the input impedance of the power line communication(PLC) networks using medium voltage power line. First of all, we proposed input and output teoninal model of PLC network, and calculated the input impedance applying the attenuation constants by radiation loss, conductor loss, dielectric loss. From the calculation result, we knew that the attenuation by radiation loss was largest, and the input impedance appears like a standing wave fonn with a fixed cycle because the high reflection at the input terminal for the characteristic impedance of the power line is very large. And also the cycle of input impedance depends on the coaxial cable length, and the amplitude depends on the characteristic impedance of power line and losses. From the measurement result, calculated result was very similar to the measured result.