• Title/Summary/Keyword: leg skin

Search Result 177, Processing Time 0.027 seconds

Thermoregulation on Menstrual Cycle -Effects of Ambient Temperatures- (생리주기에 따른 체온조절에 관한 연구 -환경온도의 영향을 중심으로-)

  • 황수경;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.2
    • /
    • pp.339-349
    • /
    • 2001
  • This study was investigated the effects of ambient temperatures and menstrual cycle on Resting Metabolic Rate(RMR), Rectal Temperature(Tre), Skin(forehead, chest, abdomen, forearm, hand, thigh, leg, foot) Temperatures, and subjective thermal sensations in 8 young Korean females(ages 22-25, voluntarily). The Tre and the Skin Temperatures were measured in once every five minute for one hour. RMR was measured three times at 30 minutes intervals by indirect calorimetry. All measurements were gathered during Luteal Phase(LP), Menstruation(M), and Follicular Phase(FP) at two levels of ambient temperatures; low(17~21$^{\circ}C$) and middle(21.1~$25^{\circ}C$). LP were the highest values during FP and M in RMR, Tre, forehead temperature, chest temperature and abdomen temperature, while the leg(leg and foot) and arm(forearm and hand) temperatures were higher during FP rather than during LP at each ambient temperature. The downward curve of Tre in the experiment was larger during FP than LP. The values in subjective thermal sensations were most comfortable during LP than M and FP at each ambient temperature. The LP-FP differences in core and mean skin temperatures, and resting metabolic rate, were more significant at middle ambient temperatures than at low ambient temperatures.

  • PDF

Distribution of clothing microclimate for making comfortable military uniform (쾌적한 군복 설계를 위한 의복기후 분포)

  • Kim, Yang-Won
    • Journal of National Security and Military Science
    • /
    • s.1
    • /
    • pp.231-247
    • /
    • 2003
  • To get the basic data for making comfortable military uniforms and to examine the distribution of clothing microclimate, seasonal fluctuations of skin temperature, subjective sensation, and clothing microclimate were measured from 10 males. The subject were questioned on thermal comfort in experiment. Clothing microclimate temperature at breast, skin temperature at four sites (breast, upper arm, thigh, leg), deep body temperature at eardrum( tympanic temperature), and subjective sensation were measured for an hour in the controlled climatic chamber. The subjects felt comfortable when skin temperature were recorded $34.43^{\circ}C$ at breast, $33.53^{\circ}C$ at upper arm, $32.9^{\circ}C$ at thigh, and 32.50 at leg. Then mean skin temperature was $33.55\pm$$0.63^{\circ}C$. Clothing microclimate temperature ranged from 31.2 to $33.8^{\circ}C$, and clothing microclimate humidity ranged from 49.80~52.41%. In the comparison of these results with the microclimate of military uniforms, it needs more insulation in clothing for military uniforms. It also says that military uniforms should be made of the textiles which can control humidity.

  • PDF

Lower Leg Amputation by Calciphylaxis in Diabetic Nephropathy Patient (A Case Report) (당뇨병성 신부전증 환자의 선단 궤양에 의한 하지절단(1예 보고))

  • Lee, Jun-Young;Yu, Jae-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.109-112
    • /
    • 2009
  • Calciphylaxis is a rare disease that appear in patients with secondary hyper-parathyroidism or chronic renal failure or that show defect in calcium phosphate metabolism which is characterized by fibrin deposit or calcification of medial wall of vessels causing gradual ischemic skin necrosis. Calciphylaxis is a disease with poor prognosis as skin necrosis can progress rapidly. If left untreated, calciphylaxis will progress to sepsis with high mortality. The treatment is controversial but kidney transplantation or parathyroidectomy is suggested to recover calcium-phosphate metabolism. The authors have experienced calciphylaxis in a patient with chronic renal failure caused by DM nephropathy with characteristic skin lesion and rapid skin necrosis. We describe this case with documentary reviews.

  • PDF

Development of Ergonomic Leg Guard for Baseball Catchers through 3D Modeling and Printing

  • Lee, Hyojeong;Eom, Ran-i;Lee, Yejin
    • Journal of Fashion Business
    • /
    • v.20 no.3
    • /
    • pp.17-29
    • /
    • 2016
  • To develop baseball catcher leg guards, 3-dimensional (3D) methodologies, which are 3D human body data, reverse engineering, modeling, and printing, optimized guard design for representative positions. Optimization was based on analysis of 3D body surface data and subjective evaluation using 3D printing products. Reverse engineering was used for analysis and modeling based on data in three postures: standing, $90^{\circ}$ knee flexion, and $120^{\circ}$ knee flexion. During knee flexion, vertical skin length increased, with the thigh and knee larger in anterior area compared to the horizontal dimension. Moreover, $120^{\circ}$ knee flexion posture had a high radius of curvature in knee movement. Therefore, guard designs were based on increasing rates of skin deformation and numerical values of radius of curvature. Guards were designed with 3-part zoning at the thigh, knee, and shin. Guards 1 and 2 had thigh and knee boundaries allowing vertical skin length deformation because the shape of thigh and knee significantly affects to its performance. Guard 2 was designed with a narrower thigh and wider knee area than guard 1. The guards were manufactured as full-scale products on a 3D printer. Both guards fit better in sitting than standing position, and guard 2 received better evaluations than guard 1. Additional modifications were made and an optimized version (guard 3) was tested. Guard 3 showed the best fit. A design approach based on 3D data effectively determines best fitting leg guards, and 3D printing technology can customize guard design through immediate feedback from a customer.

Cases of Distal Lower Leg Reconstruction with Flexor Digitorum Longus Muscle Flaps (장족지굴근판을 이용한 하지 원위부 결손의 치험례)

  • Lee, Seung-Hyun;Lee, Hye-Kyung;Cho, Pil-Dong
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.835-838
    • /
    • 2010
  • Purpose: Reconstruction of soft tissue defects in the distal lower leg, especially in the distal third, largely depends on free tissue transfer and local fasciocutaneous flaps. But several local muscle flaps have also been proposed as useful alternative reconstructive manner. In this report, the authors present the successful use of the flexor digitorum longus muscle flaps in the distal lower leg reconstruction. Methods: Case 1: An 81-year-old woman with a dog bite wound in the left distal lower leg was admitted. She had a $10{\times}8\;cm$ wound with tibial exposure along the medial aspect of the leg. Soft tissue reconstruction with a flexor digitorum longus muscle flap and a split-thickness skin graft was performed. Case 2: A 77-year-old woman had a squamous cell carcinoma in the right distal lower leg. After wide excision, a $5{\times}4\;cm$ wound was developed with exposure of the tibia. The flexor digitorum longus muscle flap was transposed and covered with a split-thickness skin graft. Results: The flexor digitorum longus muscle flaps were shown to be useful to cover tibial defects in the distal lower leg. During the follow-up period, no significant donor site morbidity was found. Conclusion: The flexor digitorum longus muscle flap can be used to cover the exposed distal tibia, especially when a free tissue transfer is not an option. The relative ease of dissection and minimal functional deficits were the major advantages of this flap, while the extent of reach into the lower third has a limitation.

Functional Properties of Mechanically Deboned Chicken Meat from Various Chicken Parts (부위별로 제조된 기계발골 계육의 가공적성에 관한 연구)

  • 이성기;김희주;김용재;조규석;김종원
    • Korean Journal of Poultry Science
    • /
    • v.21 no.4
    • /
    • pp.277-284
    • /
    • 1994
  • The functional properties of mechanically deboned chicken meat(MDCM) from whole carcass, whole carcass without exsanguination, neck without skin, leg hone, and upper back and rib were studied. Also, the effects of adding different levels of gelatin and MDCM to the comminuted meats were investigated. Proximate composition values of MDCM ranged from 54.2 to 68.6% moisture, 14.5 to 19.7% protein, 12.3 to 30.1% fat, and 1.1 to 1.3% ash. The MDCM from leg hone had a higher content of fat, and a lower contents of moisture and protein. The MDCM from neck without skin tended to be opposite to the MDCM from leg hone. The total pigment and myoglobin levels were highest in MDCM from whole carcass without exsanguination such as 3.83 and 0.29 rng /g, and those from the other parts were 1.58~2.93 mg /g and 0. 17~0.31 mg /g, respectively. The emulsifying capacity and water holding capacity were highest in MDCM from neck without skin which contained lower levels of fat, collagen and hydroxyproline, but a higher level of salt soluble protein. The emulsifying capacity of comminuted meat decreased as gelatin content increased. The extractability of hydroxyproline from gelatin showed a higher solubility in acidic solution. The MDCM could he added up to 20% level without detrimentally affecting functional properties of comminuted meats although they had less water holding capacity and cooking loss as the proportion of MDCM increased.

  • PDF

Circadian Fluctuation of Body Temperature in Different Thermal Conditions of the Distal Extremities by Clothing Type Worn during the Afternoon

  • Park, Shin-Jung
    • International Journal of Human Ecology
    • /
    • v.10 no.1
    • /
    • pp.35-45
    • /
    • 2009
  • Six healthy female volunteers twice undertook an experiment with different types of clothing leaving the arms and legs covered or uncovered at $24{\pm}0.5^{\circ}C$ and $50{\pm}5%$ RH to study how different thermal stimulation to the distal extremities during the afternoon could modulate circadian parameters of body temperature rhythm. One type of clothing consisted of long-sleeved shirts and full-length trousers (Type I, 989 g, 0.991 clo); the other type consisted of half-sleeved shirts and knee-length trousers (Type II, 750 g, 0.747 clo). Subjects wore Type I or Type II clothing during the afternoon (14:00 h - 19:00 h), and Type I clothing during the evening (19:00 h - 22:30 h) and the night sleep (22:30 h - 06:00 h). Rectal temperature and skin temperatures at the arm and leg were measured continuously. Results were as follows: 1) The circadian amplitude of rectal temperature tended to be greater, and the acrophase was significantly earlier when wearing Type II rather than Type I clothing. 2) The circadian nadirs of skin temperatures of the arm and leg were significantly lower and the amplitudes were significantly greater with Type II clothing. In addition, the acrophase and bathyphase of the circadian rhythm of arm skin temperature were significantly earlier with Type II than Type I clothing. 3) The amplitude of rectal temperature was related closely with that of arm and leg skin temperature. These results suggest that a slightly cool thermal stress during the afternoon to the arms and legs exerted by wearing half-sleeved shirts and knee-length trousers induces a greater amplitude and a phase advance of the overt circadian rhythm of body temperature.

Long-term follow-up of a severely traumatized leg treated with ipsilateral fracture-united fibular transfer in a patient with amputation of the contralateral leg: a case report

  • Kim, Eon Su;Yang, Chae Eun;Kim, Jiye;Kim, Sug Won
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.699-702
    • /
    • 2021
  • Extensive bone loss associated with severe vascular injury remains a challenge for lower extremity reconstruction. The fibular free flap has been utilized for many decades to reconstruct long-segment tibial defects. We present an unusual scenario of unilateral weight-bearing, wherein we salvaged the sole lower extremity by transfer of the fractured ipsilateral fibula and a bipedicled skin flap. A 38-year-old man sustained a severe crush injury in the right leg with loss of circulation. His left lower leg had a soft tissue defect measuring 20×15 cm with an exposed comminuted fracture and a 17-cm tibial defect, along with a segmental fracture of the fibula. Subsequently, we reconstructed the tibial defect by transferring a 17-cm-long section of the ipsilateral fibula. We covered the soft tissue defect with a bipedicled skin flap. The patient eventually began to ambulate independently after surgery.

Optimal Electrode Displacement for Motion Analysis using Bio-impedance (임피던스 방식의 동작분석을 위한 최적전극 선정)

  • 송철규;변용훈;윤대영;이명권;김거식;송창훈;김경섭;김수찬;김덕원
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2887-2890
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh, knee, and foot, and two potential electrodes are applied to the lateral, medial, and posterior position of lower leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for ankle, knee and hipjoint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements -0.87, 0.957 and 0.80. respectively. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed possibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

  • PDF

Role of the Gastrocnemius Musculocutaneous with a Propeller Style Skin Flap in Knee Region Reconstruction: Indications and Pitfalls

  • Gianluca Sapino;Rik Osinga;Michele Maruccia;Martino Guiotto;Martin Clauss;Olivier Borens;David Guillier;Pietro Giovanni di Summa
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.593-600
    • /
    • 2023
  • Background Soft tissue reconstruction around the knee area is still an open question, particularly in persistent infections and multiple reoperations scenario. Flap coverage should guarantee jointmobility and protection, even when foreign materials are implanted. The chimeric harvesting of the musculocutaneous gastrocnemius flap, based on the sural artery perforators, can extend its applicability in soft tissue reconstruction of the upper leg, overcoming the drawbacks of the alternative pedicled flaps. Methods A multicenter retrospective study was conducted enrolling patients who underwent to a pedicled, chimeric gastrocnemius musculocutaneous-medial sural artery perforator (GM-MSAP) or lateral sural artery perforator (GM-LSAP) flap for knee coverage in total knee arthroplasty (TKA) recurrent infections and oncological or traumatic defects of the upper leg from 2018 to 2021. Outcomes evaluated were the successful soft tissue reconstruction and flap complications. Surgical timing, reconstruction planning, technique, and rehabilitation protocols were discussed. Results Twenty-one patients were included in the study. Nineteen GM-MSAPs and 2 GM-LSAPs were performed (soft tissue reconstruction in infected TKA [12], in infected hardware [4], and in oncological patients [5]). Donor site was closed primarily in 9 cases, whereas a skin graft was required in 12. Flap wound dehiscence (1), distal flap necrosis (1), distal necrosis of the skin paddle (1), and donor site infection (1) were the encountered complications. Flap reraise associated to implant exchange or extensive debridement was successful without requiring any further flap surgery. Conclusion The propeller-perforator GM-MSAP offers qualitative defect coverage and easiness of multiple flap reraise due to skin availability and its laxity.