• 제목/요약/키워드: leakage preventing plate

검색결과 4건 처리시간 0.014초

화학물질 저장 탱크와 방류벽 사이의 공간 부족 개선을 위한 누출 방지판의 안정성 평가 기준 (Technical Criterion of Safety Evaluation of Leakage Preventing Plates for Alleviating Space Shortage Between Chemical Storage Tank and Dike)

  • 이은별;곽솔림;최영보
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.42-50
    • /
    • 2018
  • The Chemical Controls Act strictly regulates for the chemical companies to establish sufficient space between the liquid chemical tank and dike, but facilities already installed suffer from the space shortage between the tank and dike. Installing leakage preventing plates on the dike is considered as one of the economic solutions that can alleviate the space deficiency. However, there is no technical and reasonable criterion for the safety evaluation of the leakage preventing plate on the dike. In order to address this problem, we provide generalized and verified calculating equations that give maximum height and horizontal distance of leakage trajectories. Through the proposed equations, proper heights of the leakage preventing plates on the dike can be easily determined. In this study, new calculating methods are also developed to determine the impact force of the liquid to the leakage preventing plates. In addition, we performed the reactivity experiments between four corrosive liquid chemicals and two stainless steel materials that are candidate substances for the construction of the leakage preventing plate. The results of this study is expected to be applicable as a guideline in the design of safe dike and its leakage preventing plates.

A method to prevent cerebrospinal fluid leakage: Reinforcing acellular dermal matrix

  • Lee, Hojune;Eom, Ye Seul;Pyon, Jai-Kyong
    • 대한두개안면성형외과학회지
    • /
    • 제21권1호
    • /
    • pp.45-48
    • /
    • 2020
  • In neurosurgical cases, problems related to wound healing can vary from simple wound dehiscence to multilayer defects. This study demonstrates an effective method to prevent persistent cerebrospinal fluid (CSF) leakage using reinforcing acellular dermal matrix in neurosurgical patients with wound dehiscence. A 52-year-old woman was admitted for management of recurrent glioblastoma. After tumor removal surgery, the patient experienced sustained CSF leakage from the wound despite reparative attempts. The plastic surgery team performed wound repair procedure after remnant tumor removal by the neurosurgery team. Acellular dermal matrix was applied over the mesh plate to prevent CSF leakage and the postoperative status of the patient was evaluated. No sign of CSF leakage was found in the immediate postoperative period. After 3 years, there were no complications including CSF leakage, wound dehiscence, and infection. We hereby propose this method as a feasible therapeutic alternative for preventing CSF leakage in patients experiencing wound problem after neurosurgical procedures.

Anterior skull base reconstruction using an anterolateral thigh free flap

  • Kim, Shin Hyun;Lee, Won Jai;Chang, Jong Hee;Moon, Joo Hyung;Kang, Seok Gu;Kim, Chang Hoon;Hong, Jong Won
    • 대한두개안면성형외과학회지
    • /
    • 제22권5호
    • /
    • pp.232-238
    • /
    • 2021
  • Background: Galeal or temporalis muscle flaps have been traditionally used to reconstruct skull base defects after tumor removal. Unfortunately, these flaps do not provide sufficient vascularized tissue for a dural seal in extensive defects. This study describes the successful coverage of large skull base defects using anterolateral thigh (ALT) free flaps. Methods: This retrospective study included five patients who underwent skull base surgery between June 2018 and June 2021. Reconstruction was performed using an ALT free flap to cover defects that included the intracranial space and extended to the frontal sinus and cribriform plate. Results: There were no major complications, such as ascending infections or cerebrospinal leakage. Postoperative magnetic resonance imaging showed that the flaps were well-maintained in all patients. Conclusion: Successful reconstruction was performed using ALT free flaps for large anterior skull base defects. In conclusion, the ALT free flap is an effective option for preventing communication between the nasal cavity and the intracranial space.

안전한 전력전달을 위한 새로운 형태의 자기케이블 (A New Concept of Magnetic Cable for Safe Mobile Power Delivery)

  • 이우영;허진;최수용;임춘택
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.542-553
    • /
    • 2011
  • 본 논문에서 방전 또는 스파크로 인한 전기화재, 폭발사고 및 감전 사고의 위험 없이 고주파 고전력을 안전하게 전달할 수 있는 새로운 형태의 실용적인 자기케이블을 처음으로 제안하였다. 또한, 케이블 사이에서 발생하는 누설자속에 대한 자기저항을 주변효과(fringe effect)까지 고려하여 정량적으로 해석하였다. 자기케이블에 상쇄코일, 상쇄금속판, 상쇄금속관과 같은 상쇄실드 적용함으로써 자기케이블 사이의 누설자속을 급격히 줄여 콤팩트한 자기케이블을 구현하였고, 장거리 전력전송을 가능하게 하였다. 입력전류 $10A_{rms}$(20kHz)에서 상쇄금속관이 적용된 1.5m길이, 5cm의 케이블 사이의 간격을 갖는 자기케이블로 353.8W의 전력을 68%효율로 전달하였다. 이는 상쇄금속관을 적용하지 않았을 때에 비해 출력전력은 약 25배, 효율은 약 7배 높은 수치다. 본 논문에서는 제안된 자기케이블의 성능 특성을 실험과 자장 시뮬레이션을 통해 분석 및 검증하고 비교하였으며, 기대했던 우수한 성능을 실제로 확인하였다.