• Title/Summary/Keyword: leakage accidents

Search Result 281, Processing Time 0.025 seconds

A Leakage Current Supervising Control and Data Acquision in the Building based on Embedded System (임베디드 시스템을 이용한 빌딩 누전감시 시스템)

  • Shin, Seung-Woo;Yu, Jong-Il;Chang, Kyung-Bae;Shim, Il-Joo;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2457-2460
    • /
    • 2004
  • As the usage of electron electricity is rapidly increasing, corresponding accidents also take place proportionately. Although various losses occur very often because of senility of system and maintenance, only a earth leakage current breaker by a leakage current alert is used. That means it is always fraught with dander. This paper, we propose to measure and cut a leakage current and method of taking a measurement current short circuit. Besides, through keeping watch communication with server, prevent electric loss and mishap in advance.

  • PDF

The study of Taxonomy of Performance Shaping Factors for Human Error Management (인적오류 관리를 위한 수행영향인자 분류에 관한 연구)

  • Jung, Kyung-Hee;Cho, Jai-Rip
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2010.04a
    • /
    • pp.157-160
    • /
    • 2010
  • Almost all companies have paid much attention to the safety management ranging from maintenance to operation even at the stage of designing in order to prevent accidents, but fatal accidents continue to increase throughout the world. In particular, it is essential to systematically prevent such fatal accidents sa fire, explosion or leakage of toxic gas at factories in order to not only protect economic losses and environmental pollution. In addition, HRA may be used to detect the human errors which may cause accidents or trace back to any mistake on the part of workers. This work focuses on the coincidence of human error and mechanical failure for management of human error, and on some important performance shaping factors to propose a method for improving safety effectively of the process industries.

  • PDF

Development and Evaluation of Human Reliability Analysis Model for the Reduction of Human Errors (인적오류 저감을 위한 인간 신뢰도 분석 체계 및 평가에 관한 연구)

  • Jung, Kyung-Hee;Byun, Seong-Nam;Cho, Jai-Rip
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2048-2051
    • /
    • 2010
  • Almost all companies have paid much attention to the safety management ranging from maintenance to operation even at the stage of designing in order to prevent accidents, but fatal accidents continue to increase throughout the world. In particular, it is essential to systematically prevent such fatal accidents as fire, explosion or leakage of toxic gas at factories in order to not only protect the workers and neighbors but also prevent economic losses and environmental pollution. In addition, HRA may be used to detect the human errors which may cause accidents or trace back to any mistake on the part of workers. Usually, HRA technique is used in association with other risk assessment techniques. Moreover, it can serve to enumerate the human errors which may occur during operation or down-time or correct the existing system to reduce the mistakes. This work focuses on the coincidence of human error and mechanical failure for management of human error, and on some important performance shaping factors to propose a method for improving safety effectively of the process industries.

  • PDF

A Study on the Range of Damage Effects of Benzene Leakage Accidents using the KORA Program (KORA 프로그램을 활용한 벤젠 누출사고 피해영향범위에 관한 연구)

  • Cha, Jeong-Min
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.112-120
    • /
    • 2019
  • Benzene is a class 4 hazardous material according to the Act on the Safety Control of Hazardous Substances. This study qualitatively evaluated the damage size of a "toxic" accident and "pool fire" accidents based on benzene in a virtual scenario of a fire and leakage accident during unloading at a port facility. The KORA program was used as an evaluation method, which is supported as a universal program by the National Institute of Chemical Safety. The range of damage effects of a benzene-induced fire and leakage accident was predicted. In the case of toxic damage range, the accident's damage effect range for the "worst case scenario" was reduced by up to 5.11% with a decrease in the size of the leakage hole. In the case of the leakage time, the damage effect range increased to 145.12% with a 10 min leakage time compared to that of a 5 min leakage time and went up to 20 min (212.29%) with a 20 min leakage time. In the case of pool-fire-induced damage, the damage effect range by radiant heat in the "worst case scenario" was 228.8 m in radius from the center of the handling facility. In the "alternative scenario," the damage effect range by radiant heat was reduced by up to 8.26% compared to that in the "worst case scenario" since the size of the leakage hole was decreased by reducing the cross-sectional area of the pipe.

Statistical Analysis of Chemical Substance Transporting Accidents (화학물질 운송 화학사고의 통계 특성 분석에 관한 연구)

  • Lee, Tae-Hyung;Lee, Sang-Jae;Shin, Chang-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.23-30
    • /
    • 2016
  • This study analyzed the characteristics of chemical accidents, including the accidents occurring each year according to status, type of accident, accident cause for chemical substance transporting accidents. The major aim of this study was to provide information on the chemical accidents that occurred involving chemical substance transporting accidents from 2013 to July - 2016. The total incidence of chemical transporting accidents was 77 cases; 74 cases occurred by the spill & leakage type. The main cause of the accidents analyzed was traffic accidents (41 cases). Forty-six accidents were related to hazardous chemical substances. Among the 46 hazardous chemical substances involved in transporting chemical accidents, 46% of the accident substances were hydrogen chloride. For the prevention and response to accidents occurring during the transportation of chemicals, it is necessary to complement the precautions for chemical accidents caused by transportation accidents and chemical spills and leaks of chemicals. In addition, when the chemical transport of an accident occurs, it is necessary to apply a chemical transport safety system for chemical transfer.

Development and Performance Test of Online Electrical Safety Monitoring System Applying an Algorithm to Measure Resistive Leakage Currents using Phase Differences (위상차를 이용한 저항성 누설전류 측정 알고리즘을 적용한 온라인 전기안전 감시시스템의 개발 및 성능시험)

  • Yoo, Jeong Hyun;Kim, Hie Sik;Jeong, Yong Wook
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.27-32
    • /
    • 2018
  • Nowadays, to prevent electrical accidents in Korea, inspectors directly performed checking general electrical facilities as a cycle from every one to three years. It is difficult to presuppose an omen because intact conditions of electrical equipments are not kept at the time of inspection. In this paper, in order to ensure effectiveness of an online basis electric inspection, we developed an electrical safety IoT system using LoRa communication technology to enable monitoring mainly electrical safety components such as overcurrent, overvoltage, resistive leakage current, and power. Then we proposed a method for verifying performances of the prosed electrical safety IoT system. Resistive leakage currents are calculated by using difference of phase between voltages and currents. We verified that average errors are 0.97%, which reference goal is ${\pm}5%$ for a device, through reliability test according to conditions. Results of this research can be used as basic study materials to develop technologies for measuring three phase leakage current and for implementing public electrical safety. platform.

A Study on Safety Assessment of Hydrogen Station (수소충전소의 안전성 평가 연구)

  • PYO, DON-YOUNG;KIM, YANG-HWA;LIM, OCK-TAECK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.499-504
    • /
    • 2019
  • Due to the rapid spread and low minimum ignition energy of hydrogen, rupture is highly likely to cause fire, explosion and major accidents. The self-ignition of high-pressure hydrogen is highly likely to ignite immediately when it leaks from an open space, resulting in jet fire. Results of the diffusion and leakage simulation show that jet effect occurs from the leakage source to a certain distance. And at the end of location, the vapor cloud explosion can be occurred due to the formation of hydrogen vapor clouds by built-up. In the result, it is important that depending on the time of ignition, a jet fire or a vapor cloud explosion may occur. Therefore, it is necessary to take into account jet effect by location of leakage source and establish a damage minimizing plan for the possible jet fire or vapor cloud explosion. And it is required to any kind of measurements such as an interlock system to prevent hydrogen leakage or minimize the amount of leakage when detecting leakage of gas.

A Study on The Countermeasure by The Types through Case Analysis of Industrial Secret Leakage Accident (산업기밀 유출사고 사례분석을 통한 유형별 대응방안 연구)

  • Chang, Hangbae
    • Convergence Security Journal
    • /
    • v.15 no.7
    • /
    • pp.39-45
    • /
    • 2015
  • Industrial secrets that companies own recently protected by various act related industrial security such as Trade Secret Act, Act on Prevention of Divulgence and Protection of Industrial Technology, etc. However, despite such protection infringement and leakage accidents of industrial secrets is increasing every year. According to a survey conducted by KAITS(Korean Association for Industrial Technology Security) annual average of estimated damage by industrial secrets leakage is estimated to be "50 trillion won." This is equivalent to the amount of annual revenue of small businesses more than 4,700 units. Following this, industrial secrets leakage causes serious damages to competitiveness of nation and companies and economic. However investment and effort to the industrial secrets leakage crime is lack of level compared to the scale of damage. Actually, most companies except some major companies are lack of response action about industrial secrets leakage because of shortage of separate organization, workforce, budget for industrial secrets leakage security. This paper aims to understand the overall flow of the industrial secrets leakage crime through various taxonomy such as cause of occurrence and leakage pathway and grasp the condition of damage from industrial secrets leakage through analyzation of internal and external industrial secrets leakage crime. This is expected to be the basis for related research.

A Study on the Development of Calculation Tables and Formulas for Determining Separation Distance in Case of Cl2・HF Tank-lorry Leakage (염소・불화수소 탱크로리 누출사고 시 이격거리 산정을 위한 산정표 및 산정식 개발 연구)

  • Jeon, Byeong-Han;Kim, Hyun-Sub;Lim, Sang-Min;Lee, Joo-Chan;Lee, Gang-San
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.212-219
    • /
    • 2021
  • Chemical accidents caused by transport vehicles account for 20% of all chemical accidents every year, but there are difficulties in the accident-response process due to repeated situations where the impact assessment information is unknown. In this study, we developed a calculation table and formula for predicting the range of damage for chlorine and hydrogen fluoride, which have a high domestic usage, high risk of accidents, and high accident frequency in the last 7 years. The calculation table is based on the leakage rate, wind speed, and temperature, and the calculation formula was derived using R software for special situations where it is difficult to apply the calculation table. The calculation table and formula could be used on site by related organizations to obtain important information for decision making, which could help in minimizing damage from chemical accidents, setting separation distances, and deciding to evacuate residents.

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.