• 제목/요약/키워드: leakage ability

검색결과 139건 처리시간 0.025초

Nanoleakage of apical sealing using a calcium silicate-based sealer according to canal drying methods

  • Yoon-Joo Lee;Kyung-Mo Cho;Se-Hee Park;Yoon Lee;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • 제49권2호
    • /
    • pp.20.1-20.13
    • /
    • 2024
  • Objectives: This study investigated the nanoleakage of root canal obturations using calcium silicate-based sealer according to different drying methods. Materials and Methods: Fifty-two extracted mandibular premolars with a single root canal and straight root were selected for this study. After canal preparation with a nickel-titanium rotary file system, the specimens were randomly divided into 4 groups according to canal drying methods (1: complete drying, 2: blot drying/distilled water, 3: blot drying/NaOCl, 4: aspiration only). The root canals were obturated using a single-cone filling technique with a calcium silicate-based sealer. Nanoleakage was evaluated using a nanoflow device after 24 hours, 1 week, and 1 month. Data were collected twice per second at the nanoscale and measured in nanoliters per second. Data were statistically analyzed using the Kruskal-Wallis and Mann-Whitney U-tests (p < 0.05). Results: The mean flow rate measured after 24 hours showed the highest value among the time periods in all groups. However, the difference in the flow rate between 1 week and 1 month was not significant. The mean flow rate of the complete drying group was the highest at all time points. After 1 month, the mean flow rate in the blot drying group and the aspiration group was not significantly different. Conclusions: Within the limitations of this study, the canal drying method had a significant effect on leakage and sealing ability in root canal obturations using a calcium silicate-based sealer. Thus, a proper drying procedure is critical in endodontic treatment.

Modified Continuous Wave Technique을 이용한 근관충전시 형성된 치근단 크기가 치근단 폐쇄에 미치는 영향 (EVALUATION OF THE INFLUENCE OF APICAL SIZES ON THE APICAL SEALING ABILITY OF THE MODIFIED CONTINUOUS WAVE TECHNIQUE)

  • 류무현;정일영;이승종;신수정;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제33권1호
    • /
    • pp.66-75
    • /
    • 2008
  • 본 연구에서는 근관형성의 치근단 크기가 근관 충전의 치근단 폐쇄에 미치는 영향에 대해 알아보고자 하였다. 36개의 단근관, 단근치를 대상으로 3가지 치근단 크기 (Master apical file : #25, #40, #60)에 따라 3가지 실험군으로 나누어 $Profile^{(R)}$$LightSpeed^{(R)}$를 이용하여 근관을 확대하고, Modified continuous wave technique으로 근관충전을 시행하였다. 미세누출의 측정을 위해 실험군당 10개의 치아를 1주일간 India ink에 넣어 색소 침투를 일으키고 치아를 투명화시켜 미세누출의 정도를 측정하였다. 미세누출에 치근단 크기가 미치는 영향을 분석하기 위하여 Kruskal-Wallis one-way ANOVA를 시행하였고, 사후 검정을 위하여 Student-Newman-Keuls method를 시행하였다. 또한, 치아 단면의 형태를 관찰하기 위하여 색소 침투까지 실행된 각 실험군당 2개의 치아를 근첨 1 mm에서 4 mm까지 1 mm간격으로 수평 절단하고 사진 촬영하였다. 각 실험군에서 측정된 미세누출양을 Krustal-Wallis one-way ANOVA에서 분석한 결과 치근단 크기는 유의성 있게 (P < 0.05) 미세누출에 영향을 미쳤으며 치근단 크기가 클수록 미세누출의 평균간과 표준편차 값은 감소하는 경향을 보였다. Student-Newman-Keuls method를 통한 사후 검정에서 치근단 크기가 #25 - #40, #25 - #60에서 유의 한 차이를 보였으며 #40 - #60간에는 통계적인 유의차는 없었다. 단면형태에서는 대부분의 치아에서 난원형의 근관 형태를 관찰 할 수 있었고, 치근단의 크기가 작을수록 성형된 근관에 불규칙한 내면이 존재하였고 gutta-percha나 sealer로 충전되지 않는 recess의 면적이 증가함을 알 수 있었으며 이러한 recess는 미세누출의 통로가 됨을 확인 할 수 있었다. 본 연구 결과, Modified continuous wave technique으로 근관충전시 근관 형성된 치근단 크기가 커질수록 보다 일관되고 성공적 인 결과를 예상할 수 있는 근관충전을 시행할 수 있음을 알 수 있었다.

Gibberellic acid와 여러 가지 제초제와의 혼합처리가 메귀리에 대한 제초활성에 미치는 영향 (Effect of mixtures of gibberellic acid and several herbicides on the herbicidal activity against wild oat (Avena fatua L.))

  • 김진석;최정섭;홍경식;조광연
    • 농약과학회지
    • /
    • 제2권3호
    • /
    • pp.107-116
    • /
    • 1998
  • Gibberellic acid에 대한 밀과 메귀리간에 차등반응을 이용하여 제초제에 gibberellic acid를 첨가함으로써 상대적으로 민감한 반응을 보였던 메귀리를 효과적으로 방제할 수 있는 조합을 찾고, 그 효과증대의 생리적 원인을 조사하고자 실험하였다. 밀은 $GA_{3}$에 대한 낮은 신장반응을 보였으나, 메귀리는 이보다 $4{\sim}5$배 높은 반응을 보였다. $GA_{3}$에 침지된 메귀리 종자를 파종한 후 토양처리했을 때는 isoproturon, trifluralin의 효과가 증진되었다. 경엽처리의 경우 $GA_{3}$는 tralkoxydim fenoxaprop-ethyl, metsulfuron-methyl, metribuzine, isoproturon의 효과를 증진시켰으나, oxyfluofen과 paraquat의 효과에는 거의 영향을 미치지 않았다. 경엽처리조건에서 체계처리를 할 경우 tralkoxydim처리 이전에 $GA_{3}$를 처리하면 tralkoxydim의 효과를 증진시켰으나, tralkoxydim처리 이후에 $GA_{3}$를 처리하면 효과가 낮은 경향이었다. 그러나 $GA_{3}$를 어느 시기에 처리하여도 tralkoxydim의 신장저해효과를 증진 또는 경감시키지는 못하였고, $GA_{3}$가 처리된 잎의 과산화작용 화합물에 대한 반응은 무처리와 비교하여 일정한 경향을 보이지 않았다. 이들 결과로 보아 $GA_{3}$가 일부 제초제의 효과를 증진시킨 것은 조직의 연화(세포신장 촉진)에 의한 높은 제초반응 때문이라기보다는 제초제 흡수, 이행의 변화 또는 제초작용 발현과 관련한 체내대사의 촉진 때문으로 추정된다.

  • PDF

치근단 역충전용 포틀랜드 시멘트 신복합재료의 물리적 성질 고찰 (Physical properties of novel composite using Portland cement for retro-filling material)

  • 이상진;조옥인;염지완;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제35권6호
    • /
    • pp.445-452
    • /
    • 2010
  • 연구목적: 이 연구의 목적은 새로운 근단 역충전 재료를 개발하기 위해 MTA, MTA와 AH-plus 혼합물 (AMTA), 그리고 실험적 개발재료인 Portland cement-Epoxy resin composite (EPPC)의 미세 누출 및 물리적인 성질을 비교하는 것이다. 연구 재료 및 방법: 발거 치아 49개를 근관 성형하고 gutta-percha와 sealer로 충전하였다. 각 치아의 치근을 근단부 3 mm에서 절단하고 3 mm 깊이의 역충전 와동을 형성하였다. 15개씩 무작위로 분류한 치근을 세 군으로 나누어 각각 MTA, AMTA, EPPC로 충전하였고 네 개의 치근은 대조군으로 사용하였다. 각 군의 재료로 역충전이 완료된 모든 실험군을 젖은거즈로 덮고 24시간 동안 경화시켰다. 경화 후 72시간 동안 1% methylene blue 염색액에 담근 후, 치근단을 수직 절단하여 사진을 촬영하고 미세 누출을 평가하였다. Vicat apparatus를 사용하여 실험군 별로 경화시간을 측정하였으며, aluminum step wedge를 사용한 디지털 방사선 사진을 촬영하여 각 군의 방사선 불투과도를 평가하였다. 미세누출과 경화시간에 대해 각 군간의 차이를 일원배치분산분석 및 Scheffe 사후 검증으로 유의수준 95%에서 평가하였다. 결과: AMTA와 EPPC는 MTA군에 비해 적은 미세누출량을 보였다 (p < 0.05). AMTA는 가장 높은 방사선 불투과도를 보였으며 개발 재료인 EPPC군은 5 mm aluminum 두께의 방사선 불투과도를 보였다. MTA가 가장 긴 경화시간을 나타낸반면 EPPC군은 다른 군에 비해 초기경화와 최종경화 모두 가장 짧은 경화시간을 나타냈다 (p < 0.05). 결론: 이 연구 조건하에서, 신개발 재료인 EPPC는 치근단 역충전 재료로서 기존의 MTA보다 양호한 밀폐능력과 방사선 불투과성 및 짧은 경화시간 등의 역충전 재료로서 적절한 물리적 성질을 가진 것으로 보인다.

서울대학교병원에서의 Provox 장기간 사용경험 (Long-Term Experiences of the Provox Voice Prosthesis at Snuh)

  • 정영호;박준범;원태빈;이승신;모지훈;박석원;성명훈;김광현
    • 대한기관식도과학회지
    • /
    • 제5권2호
    • /
    • pp.130-137
    • /
    • 1999
  • Background and Objectives : Provox, a recently developed tracheoesophageal prosthesis, had been widely used for voice rehabilitation after total laryngectomy for its low resistance and easiness of speech ability. But, long-term use of Provox resulted in many complications and resulted in cessation of Provox as a primary method of vocal rehabilitation. The aim of this study is to report Provox-related problems and the long-term results of Provox voice prosthesis. Materials and Methods : Medical records from patients who had undergone total laryngectomy with Provox insertion at seoul National University Hospital between January 1993 and December 1998 were reviewed retrospectively. Results : 36 patients had used 79 Provox voice prostheses during the observed period. The most common complication causing prosthesis change or removal was leakage and/or aspiration, followed by granulation formation, crusting and/or obstruction, and non-function. Median in situ lifetime of Provox was 274 days and 1-year-in situ rate was 31.0% Among 36 patients, 17 patients had undergone tracheoesophageal shunt closure at the last follow-up visit. 10 patients had complications but got along without further treatments, and 1 patient changed to Blom-Singer voice prosthesis. Only 8 patients experienced no complication, and 5 out of whom had several times of Provox change. Conclusion : long-term use of Provox resulted in discontinuation of its use due to complications in many cases. A better voice prosthesis with lower complication rate and longer in situ lifetime is needed.

  • PDF

Channel and Gate Workfunction-Engineered CNTFETs for Low-Power and High-Speed Logic and Memory Applications

  • Wang, Wei;Xu, Hongsong;Huang, Zhicheng;Zhang, Lu;Wang, Huan;Jiang, Sitao;Xu, Min;Gao, Jian
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권1호
    • /
    • pp.91-105
    • /
    • 2016
  • Carbon Nanotube Field-Effect Transistors (CNTFETs) have been studied as candidates for post Si CMOS owing to the better electrostatic control and high mobility. To enhance the immunity against short - channel effects (SCEs), the novel channel and gate engineered architectures have been proposed to improve CNTFETs performance. This work presents a comprehensive study of the influence of channel and gate engineering on the CNTFET switching, high frequency and circuit level performance of carbon nanotube field-effect transistors (CNTFETs). At device level, the effects of channel and gate engineering on the switching and high frequency characteristics for CNTFET have been theoretically investigated by using a quantum kinetic model. This model is based on two-dimensional non-equilibrium Green's functions (NEGF) solved self - consistently with Poisson's equations. It is revealed that hetero - material - gate and lightly doped drain and source CNTFET (HMG - LDDS - CNTFET) structure can significantly reduce leakage current, enhance control ability of the gate on channel, improve the switching speed, and is more suitable for use in low power, high frequency circuits. At circuit level, using the HSPICE with look - up table(LUT) based Verilog - A models, the impact of the channel and gate engineering on basic digital circuits (inverter, static random access memory cell) have been investigated systematically. The performance parameters of circuits have been calculated and the optimum metal gate workfunction combinations of ${\Phi}_{M1}/{\Phi}_{M2}$ have been concluded in terms of power consumption, average delay, stability, energy consumption and power - delay product (PDP). In addition, we discuss and compare the CNTFET-based circuit designs of various logic gates, including ternary and binary logic. Simulation results indicate that LDDS - HMG - CNTFET circuits with ternary logic gate design have significantly better performance in comparison with other structures.

원전 증기발생기 와전류검사 장치의 전기적 특성 측정 (Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP)

  • 이희종;조찬희;유현주;문균영;이태훈
    • 비파괴검사학회지
    • /
    • 제33권5호
    • /
    • pp.465-471
    • /
    • 2013
  • 원전 증기발생기는 원자로 냉각재 계통에서 발생한 열에너지를 터빈 계통의 주급수에 전달하여 터빈을 회전시키기 위한 증기를 생산하는 일종의 열교환기이다. 증기발생기 전열관의 손상은 증기발생기의 구조적 및 누설 건전성 유지 능력을 저해시키기 때문에 주기적으로 와전류검사를 수행하여 전열관의 건전성을 평가한다. 증기발생기 전열관의 건전성 평가는 보통 원자로 연료 재장전 기간 중에 수행된다. 현재 국내 증기발생기 전열관에 적용되는 와전류검사는 KEPIC 및 ASME 코드 요건에 따라 수행되며, 와전류검사 수행에 필요한 검사 시스템은 와전류검사 장치와 수집된 신호를 평가하기 위한 평가 프로그램으로 구성된다. 검사에 적용되는 와전류검사 시스템을 구성하는 핵심기기인 와전류검사 장치는 ASME 및 KEPIC 코드에서 총 고조파 왜곡율, 입출력 임피던스, 증폭기 직선성 및 안정성, 위상 직선성, 대역폭 및 복조필터 응답, 디지털 변환, 채널 간섭 등과 같은 전기적 특성을 측정하도록 규정하고 있다. 이에 따라 본 논문에서는 국내 최초로 개발한 원전 증기발생기 와전류검사 장치의 전기적 특성 측정을 위한 ASME 및 KEPIC 코드 요건을 설명하고, 이 요건에 따른 증기발생기 와전류검사 장치의 전기적 특성의 측정 결과를 제시하였다.

응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향 (THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF

늑막유착을 동반한 질환에서의 비디오 흉부수술 (Aideo-Assisted Thoracic Surgery in Pleural Adhesion)

  • 성숙환;김현조;이창하;김주현
    • Journal of Chest Surgery
    • /
    • 제29권8호
    • /
    • pp.916-922
    • /
    • 1996
  • 늑막유착이 있는 경우에서의 비디오흉부수술은 금기로 인식되어 왔다. 이러한 늑막유착이 비디오흉 부수술 도중 발견되는 경우에는 출혈 및 폐실질 손상의 가능성 등으로 인하여 개흉술로 전환하여 수술 하는 것이 보통이다. 따라서 본 병원에서는 늑막유착이 있는 경우에서의 비디오 흉부수술의 가능성에 대하여 후향적으로 연구하였다. 서울대학교병원 흉부외과에서는 1992년 7월 7일부터 1995년 9월 4일까지 비디오 흉부수술을 연속적으로 226명의 환자에서 시행하였고, 이중 50명(22.1%)에서 수술 중 늑막유착이 발견되었다. 기흉 환자 16명, 늑막 질환 환자 15명, 양성 폐결절 7명, 종격동 종양 5명, 다한증 환자 2명, 미만성 폐실질 질환의 폐생검 2명, 원발성 폐암에 대한 폐엽절제술 1명, 기관지 확장증으로 폐엽절제술을 시행 받은 2명의 환자에서 늑막유착이 있었다. 늑막유착은 포함된 범위와 유착의 정도에 따라 분류하였으며, 포함된 범위 에 따라서 I도, II도, III도로 나누었고, 유착의 정도에 따라 경도, 중등도, 심한 정도, 매우 심한 정도로 분류하였다. 수술 전 늑막의 비후가 발견되어 늑막 박피술이 필요한 정도의 늑막유착은 매우 심한 정도\ulcorner 분류하여 비디오 흉부수술을 시행하지 않았으며, 이번 연구 대상에서는 제외시켰다. 50명의 환자 중에서 유착의 정도는 경도가 15명(30.0%), 중등도가 29명(58.0%)이었으며, 심한 정도의 늑막유착도 6명(12.0%)에서 있었으며, 유착의 범위는 대부분(32명, 64.0%)이 II도에 속하였으며, I도와 III도가 각각 8명(16.0%), 10명(20.0%)이 었다. 늑막유착이 있는 환자에서 수술 시간, 흉관거치기간, 재원 일수등이 늑막유착이 발견되지 않았던 환자에 비하여 증가되어 있었다. 수술후 합병증으로 지속적 공기 유출 또는 흉관 배액이 늑막유착이 있는 환자에서 각각 18.0%와 6.0%로 늑막유착이 발견되지 않았던 환자에서의 5.1%와 1.7%에 비하여 많은 분포를 보였다. 기관지 확장증 2명(4.0%)에서 늑막유착 박 리 도중 발생한 출혈로 인하여, 개흉술로 전환하였다. 늑막유착이 있는 환자에서의 비디오 흉부수술은 수술 시간, 흉관거치기간, 재원일수등의 증가를 가져올 수 있으며, 합병증의 빈도가 높았으나, 비디오 흉부수술의 기타 장점을 고려하여 볼 때 문제점은 되지 않을 것으로 사려된다. 또한 수술 중 발견되는 예상치 못한 늑막유착 환자에서도 비디오 흉부수술의 시\ulcorner는 필요하리라 생각된다.

  • PDF