• Title/Summary/Keyword: leak frequency

Search Result 83, Processing Time 0.024 seconds

Analysis of the Cause of Waterleakage in Residential Apartment Underground Parking Ground and the Review of the Repare Methods (공동주택 지하주차장의 누수원인 분석 및 보수방안 검토)

  • Oh, Sang-Keun;Choi, Sung-Min;Song, Je-Young
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.3
    • /
    • pp.255-264
    • /
    • 2014
  • This study analyzes the cause and the repairing method of water leak by parts of basement parking lot which is recorded to have a high defect frequency in apartment buildings. It has been assessed that the cause of water leakage on the first floor upper substrate is due to such factors as landscaping and weights. During construction or through other cases, it has been determined that cracks were produced in the apartment structure because the structure was weak and exposed to the effects of the substrate movement. The base floor and underground external walls are areas that are exposed to water pressure (uplife pressure), thus in normal cases the rear surface repair of the structure using sythetic rubberized polymer gel should be considered as an effective method. However, in cases where application of waterproofing layer is required in the structure due to high water pressure, using asystolic cement milk grout to form the waterproofing layer and applying water-swelling acrylic material into the cracked areas is considered to be highly effective.

IMPROVEMENT OF CROSS-CORRELATION TECHNIQUE FOR LEAK DETECTION OF A BURIED PIPE IN A TONAL NOISY ENVIRONMENT

  • Yoon, Doo-Byung;Park, Jin-Ho;Shin, Sung-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.977-984
    • /
    • 2012
  • The cross-correlation technique has been widely used for leakage detection of buried pipes, and this technique can be successfully applied when the leakage signal has a high signal-to-noise ratio. In the case of a power plant, the measured leakage signals obtained from the sensors may contain background noise and mechanical noise generated by adjacent machinery. In such a case, the conventional method using the cross-correlation function may fail to estimate the leakage point. In order to enhance the leakage estimation capability of a buried pipe in a noisy environment, an improved cross-correlation technique is proposed. It uses a noise rejection technique in the frequency domain to effectively eliminate the tonal noise due to rotating machinery. Experiments were carried out to verify the validity of the proposed method. The results show that even in a tonal noisy environment, the proposed method can provide more reliable means for estimating the time delay of the leakage signals.

A Study of Public Library Patrons' Understanding of Library Records and Data Privacy

  • Kim, Dong-Seok;Noh, Younghee
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.4 no.1
    • /
    • pp.53-78
    • /
    • 2014
  • As instances of private information leak increase, taking steps to protect such information becomes a necessity. In this study of public library patrons, we strove for a comprehensive understanding of library usage records to suggest viable solutions for private information safety in public libraries. To this end, we investigated the patrons' understanding of library usage records and determined the relationship between different user characteristics and privacy knowledge or leaks. The results show that a high number of patrons perceived these records as their own private information, but that there was no necessity for legal procedures or consent for the use of these records. Also, even though the understanding of these usage records showed that there was a relationship between the frequency of library visits and leaks of personal information, the correlation was not particularly strong.

A Study on Accident Frequency by Installing Safety Devices in the LPG Heating and Drying Furnace (LPG 가열로 및 건조로의 안전장치 설치에 따른 사고빈도에 관한 연구)

  • Song, Dong-Woo;Kim, Ki-Sung;Kim, Choong-Hee;Lee, Seong-Gueong;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.49-54
    • /
    • 2015
  • The purpose of this study is to assess the risk of depending on the presence or absence of safety device of domestic heating and drying furnaces, by derivation and analysis of accident frequency of safety devices through FTA (Fault Tree Analysis). Installation standards are lacking in Korean for the safety device of LPG heating and drying furnace, which have a risk of explosion due to structure to trap the leaked gas. Four different safety devices were selected on the basis of NFPA and national standards for combustors of other equipment. Effects of frequency reduction in accidents were analyzed before and after installing the safety devices respectively. As a result, a minimal leakage safety device was presented for preventing damages from gas leak of domestic LPG heating and drying furnace.

A study on the application and counter measures of IC tag in international marine container transport (국제해상컨테이너운송에서 보안강화를 위한 전자태그(IC tag)의 적용과 대응방안)

  • Han, Sang-Hyun;Choi, Jun-Ho
    • International Commerce and Information Review
    • /
    • v.12 no.2
    • /
    • pp.133-158
    • /
    • 2010
  • Since 11 September 2001, the awareness of terrorists' actions has clearly risen. The potential threat of terrorists using containers poses a large risk to our economies and to our societies. In order to protect cargo from damage and terrorist threats, business and government turn to RFID and IC tags, and tradition container is replaced by IC smart container. In this study, presented application of IC tag and future tasks to Container transport by sea in viewpoint of security strengthening. First, realization and international SCM realization structural order that cover container supply chain whole of international standardization and association between industry are certainly needed. Second, it may have to try in technical development for IC tag Ratio that can read elevation moment develop suitable IC tag or reader in International Standard. Third, Need to establish concrete use policy as soon as possible in national dimension at the same time effort for international standard normalization of frequency. Finally, it shows to uses jointly with electron sealing and must solve problem about usable plan and information leak.

  • PDF

Risk Assessment and Its Application for the POSCO's Batch Annealing Furnace Gas Systems (광양제철소 소둔로 가스설비에 대한 위험성 평가 및 안전성향상안 제시)

  • Kim Y. S.;Yoo J. H.;Jeong S. Y.;Jang E. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.9-13
    • /
    • 2001
  • A complete spectrum of risk assessment including qualitative and quantitative approaches were performed for the POSCO's Batch Annealing Furnace (BAF) gas systems. The purpose of BAF is to enhance the quality of steel by annealing it with either hydrogen/nitrogen mixture gas or pure hydrogen gas. Number of gas leak scenarios were identified to generate frequency of their occurrences. With the hypothetical accident scenarios given, fire/explosion impact studies were performed to estimate magnitude of significant consequences. Several different indices were also presented from which practical safety improvement action items could be established.

  • PDF

A Study on Design and Implementation of the Tesla Coil using Semiconductor Device (반도체 소자를 이용한 테슬라 코일의 설계 및 제작)

  • Kim, Young-Sun;Kim, Dong-Jin;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1571-1576
    • /
    • 2016
  • A Tesla coil is an electrical resonant transformer circuit invented by Nikola Tesla in 1891. It is used to produce high-voltage, low-current, high frequency alternating-current electricity. Tesla coil can generate a long streamer with several million volts of electricity as a high voltage device. It is basically consists of a voltage transformer, high voltage capacitor, spark gap, primary coil, secondary coil and toroid. It is difficult to appear in the output size of the streamer is controlled by the spark gap. The general decision method of the length of streamer is to display the electric output in accordance with the design specifications in initial development plan. Design specifications and the electric output is determined by the application of facilities. In this paper the spark gap is replaced with periodic switching semiconductor device to control output voltage easily in order to apply overvoltage protective circuit due to a secondary coil and a performance test. In these days, their main use is for entertainment and educational displays of the museum, although small coils are still used as leak detectors for high vacuum systems.

Likelihood Estimation of Release Incidents in Chlorine$(Cl_2)$ Facility (염소$(Cl_2)$시설에 대한 누출가능성 예측)

  • Lee, Jae-Jun;Kim, Tae-Su;Lee, Dae-Hee;Yoo, Byung-Tae;Baek, Jong-Bae;Ko, Jae-Wook;An, Hyung-Hwan
    • 한국가스학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.180-185
    • /
    • 2007
  • Likelihood analysis was used for the revision of release probability/frequency in chlorine Injection facilities used in chlorine process. Typically these facilities consist of pressure cylinder, vaporizer, pipeline, measuring equipment and safety equipment. This paper described the incident scenarios considered, likelihood analysis procedure and the selection and application of basic events and for failure rates of mechanical components. Human errors were also considered. The major objective of this paper is to estimate the likelihood of each determined incident scenarios. We estimated failure rates of mechanical components based on likelihood analysis procedure. Human errors were also considered. It was estimated to have $5.73{\times}10^{-5}\;Cl_2$ leak per year during the major $Cl_2$ handling process. The probability of failure in scrubber system was $4.11{\times}10^{-2}/demand$.

  • PDF

Circumferential Resection and Reconstruction of The Mediastinal Trachea Without Prosthesis for Tracheal Stenosis: A Report of 4 Cases (기관삽입관에 의한 기관협착증 의 외과적 치료: 4례 보고)

  • 박주철
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.17-24
    • /
    • 1977
  • The present treatment of respiratory failure, using cuffed endotracheal and tracheostomy tube has produced, apparently with increasing frequency, three lesions which have serious ceminical manifestations such as tracheal stenosis, tracheomalasia, and localized tracheal erosion. Extensive resection and reconstruction of the trachea must be necessary because conservative treatment has generally failed in the fully developed stenotic lesion. of the mediastinal trachea following extensive resection is best accomplished by direct anastomosis of the patient`s own tracheobronchial tissue. Any replacement of the mediastinal trachea must be air tight and laterally rigid, and must heal dependably. A variety of materials has been used for substitution following circumferential excision of tracheal segments within the mediastinum. These attempts have often failed because of early leak or late stenosis. We have successfully performed circumferential resection and primary end-to-end anastomosis of the trachea for 4 cases of post-intubation tracheal stenosis located a few centimeter below the tracheostomy stoma in the period of 3 years between 1974 and 1976. The lesion in one patient was found in the upper trachea which was approached anteriorly through a cervicomediastinal incision with division of the upper sternum. Other three located in the lower half of the trachea were operated through a high transthoracic incision with appropriate hilar mobilization in addition to cervical flexion for the development of the cervical trachea into the mediastinum. There were no hospital death, but suture line granulations occurred in two patients were managed by bronchoscopic removal of granulations without difficulties.

  • PDF

Leveraging the Smart device for waterworks manhole management (상수도맨홀 관리를 위한 스마트 관리장치의 활용)

  • Chun, Haebok;Kim, Yeongkwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.141-148
    • /
    • 2017
  • The waterworks company is in charge of managing water facilities buried underground, and the management has been centered on manholes. However, since there is no standard management manual, it has been impossible to introduce and operate a systemized managing tool by water service providers and managers, and manhole management has been carried out by individual data recording personnel for each water service provider. When the management is carried out individually, the data to be shared by other waterworks managers tend to be privatized, and consequently, it may become a big obstacle to proceed with many civil works such as emergency leak repair, road excavation, replacement of old buildings. This report introduces RFID (Radio Frequency Identification) system which is based on the magnetic field capable of IOT. It also describes the necessity of leveraging the system for smart managing of pipe management record that has been done by hand writing. The RFID system includes RFID marker, data reader, portable computer operating program, and data base server operating program. In this system, the data is managed with a single communication device, and it would be possible to share the information on the underground facilities and water treatment facilities. This RFID technology is expected to provide water service providers with opportunities to develop more scientific and modernized underground facilities information systems.