• Title/Summary/Keyword: lead-filter

Search Result 190, Processing Time 0.023 seconds

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Estimating time-varying parameters for monthly water balance model using particle filter: assimilation of stream flow data (입자 필터를 이용한 월 물 수지 모형의 시간변화 매개변수 추정: 하천유량 자료의 동화)

  • Choi, Jeonghyeon;Kim, Sangdan
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.6
    • /
    • pp.365-379
    • /
    • 2021
  • Hydrological model parameters are essential for model simulation and can vary over time due to topography, climatic conditions, climate change and human activity. Consequently, the use of fixed parameters can lead to inaccurate stream flow simulations. The aim of this study is to investigate an appropriate method of estimating time-varying parameters using stream flow observations, and how the simulation efficiency changes when stream flow data are assimilated into the model. The data assimilation method can be used to automatically estimate the parameters of a hydrological model by adapting to a variety of changing environments. Stream flow observations were assimilated into a two parameter monthly water balance model using a particle filter. The simulation results using the time-varying parameters by the data assimilation method were compared with the simulation results using the fixed parameters by the SCEM method. First, we conducted synthesis experiments based on various scenarios to investigate if the particle filter method can adequately track parameters that change over time. After that, it was applied to actual watersheds and compared with the predictive performance of stream flow when using parameters that change with time and fixed parameters. The conclusions obtained through this study are as follows: (1) The predictive performance of the overall monthly stream flow time series was similar between the particle filter method and the SCEM method. (2) The monthly runoff prediction performance in the period except the rainy season was better in the simulation by the periodically changing parameters using the data assimilation method. (3) Uncertainty in the observational data of stream flow used for assimilation played an important role in the predictive performance of the particle filter.

The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light (녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정)

  • Chang, K.Y.;Ko, H.C.;Lee, J.J.;Yoon, Young Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two green light emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diode is suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature. Another study showed that, green light is better for monitoring heart rate during motion than led light. However, it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensor using green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambient light and will propose a solution. This study has two parts of research method. One is measurement system that composed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmography signal is measured by measurement board that composed high-pass filter, low-pass filter and amplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmography signal is measured with lead II electrocardiography signal at the same time and it is measured at the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standard signal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform. The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparing the correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emitting diodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambient light. The waveform and heart rate that measured by two green light emitting diodes are more identical than others. The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

One mg Tar Cigarettes-From the components point of view (초저타르 담배의 설계-요소별 분석)

  • Baskevitch, Nicolas
    • Proceedings of the Korean Society of Tobacco Science Conference
    • /
    • 1997.10a
    • /
    • pp.91-113
    • /
    • 1997
  • One mg tar cigarettes represent a growing segment of the market, in various parts of the world but specially in the Far East. Cigarette design of ultra low tar cigarettes is not easy to manage: a simple extension of the techniques used in the design of the low tar segment will usually lead to tasteless cigarettes. A detailed analysis of the design of commercial ultra low tar cigarettes in different countries shows that no 《dominant design》 has yet been adopted. Blend composition, blend density, filter design, degree of filter ventilation all vary in a large range from cigarette brand to cigarette brand, and will influence the puff number, the tar concentration in each puff and ultimately the taste. We will report and comment on the detailed analysis of 17 commercial brands of ultra low tar cigarettes. We will then review the specific influence of tobacco chemical composition, introduction of reconstituted tobacco, influence of cigarette paper characteristics, selection of filter ventilation components on the burn characteristics and tar delivery; to conclude that the commercial success of an ultra low tar cigarette is linked to a very delicate balance between this techniques and... good marking of course!

  • PDF

Byproducts from Piggery Wastewater Treatment for the Sustainable Soil Amendment and Crop Production

  • Yang, Jae E.;Kim, Jeong-Je;Shin, Young-Oh;Shin, Myung-Kyo;Park, Yong-Ha
    • Journal of Applied Biological Chemistry
    • /
    • v.42 no.3
    • /
    • pp.140-145
    • /
    • 1999
  • Livestock manure is generally beneficial to soil and crop production when appropriate amount is applied, but excessive application may be detrimental to soil and water environments. A proper protocol of livestock waste treatment is required to manage the quality of soil and water. A trickling filter system using rice straw media was employed to treat piggery wastewater from small-scaled livestock farms as an alternative to the currently available methods. Batches of piggery wastewater were treated with this system, and the byproducts of rice straw media and trickling filtrate were applied to the soil with cultivating rye (Secale cereale L.). Objective of this research was to characterize these byproducts for the sustainable soil amendments and rye production. Both the treated straw medium and filtrate were proven to be effective organic fertilizers for rye plant development, with the enhanced but balanced absorption of nutrients. The synergistic effects of filtrate in addition to straw application did not show, but the filtrate appeared to lead to a higher water content of the plant. No specific nutrient deficiency or toxicity symptom was shown due to the salts derived from the byproducts applied. Chemical parameters of the soil quality were significantly improved with the application of straw medium either with or without the filtrate. Judging from parameters relating to the salt accumulations, such as sodium adsorption ratio (SAR), electrical conductivity (EC), exchangeable sodium percentage (ESP), potassium adsorption ratio (KAR), and residual P concentrations, the byproducts from piggery wastewater exhibited no detrimental effects on soil quality within the ranges of treatments used. In addition to the effectiveness of the rice straw trickling filter system for the small-scaled swine farms, both rice straw medium and filtrate could be recycled for the sustainable soil amendment and plant nutrition.

  • PDF

Analysis on Vehicle Fires Caused by Damage of Diesel Particulate Filter (DPF) (매연저감장치 손상에 기인한 차량화재 사고사례 분석)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.70-76
    • /
    • 2012
  • This paper deal with vehicle fire caused by damage of diesel particulate filter (DPF) on diesel passenger vehicles. In order to reduce particulate matters included exhaust gases, a DPF in the exhaust system were installed diesel vehicles. A DPF was broken by excessively trapped particulate matters, regeneration error with a malfunction of ECU and defect of suction system such as swirl valve. If the DPF was broken, hot exhaust gases was released to the bottom of vehicle and released hot exhaust gases lead to occur the fire through combustible materials around the exhaust system. When a fire happened in the diesel vehicle caused by damage of DPF, silicate inorganic compounds were attached to the exhaust ventilation pipe and muffler. The silicate inorganic compounds were created by DPF combustion consisting of raw material ceramics. If the silicate inorganic compounds attached to the tail pipe in the diesel passenger vehicles, its fire cause will be assumed damage of DPF.

Removal Technologies of Odor and Volatile Organic Compounds from Industrial Processes (산업체 VOC/악취 저감기술)

  • Choo, Soo-Tae;Nam, Chang Mo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.3
    • /
    • pp.289-297
    • /
    • 2004
  • Emissions of volatile organic compounds and odors from various industrial processes not only pollute surrounding life environments, but also lead to the deterioration of the working environments, causing various industrial health and business problems. These pollutants are usually stimulating, irritating, malodorous and sometimes carcinogenic, Which should be reduced in the pollutants formation, stage, but the practical processes do not allow This paper describes the major sources of VOC and odors, and their sampling/analysis methods. Furthermore, various removal technologies for these pollutants are suggested, which particularly include the characteristics of the catalytic and scrubber/carbon filter combined process, and even process design technologies.

  • PDF

Single-phase SRM Drive with Torque Ripple Reduction and Power Factor Improvement

  • Lee, D.H.;Ahn, J.W.;Lee, Z.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.57-61
    • /
    • 2006
  • In the single-phase switched reluctance motor (SRM) drive, the required DC source is generally supplied by the circuit consisting of bridge rectifier and large filter capacitor connected with DC line terminal. Due to the large capacity of the capacitor, the charged time of capacitor is very short from the AC source. Lead to the bridge rectifiers draws pulsating current from the AC source side, which results in reduction of power factor and low system efficiency. Therefore a novel single-phase SRM drive system is presented in this paper, which includes drive circuit realizing reduction of torque ripple and improvement of power factor with a novel switching topology. The proposed drive circuit consists of one switching part and diode, which can separate the output of AC/DC rectifier from the large capacitor and supply power to SRM alternately, in order to realize the torque ripple reduction and power factor improvement through the switching scheme. In addition, the validity of the proposed method is tested by some simulations and experiments.

  • PDF

Monitoring of Chatter Vibration by Frequency Analysis of AE Signals (AE 신호의 주파수분석에 의한 Chatter 진동의 감시)

  • 조대현
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.5
    • /
    • pp.157-164
    • /
    • 2000
  • A machine tool generally has some serious stability problems in the form of tool chatter during the cutting process. Chatter vibration deteriorates the surface finish, reduce tool and machine life, accelerates machine tool system component wear, and may lead to an unacceptable noise sound in the working environment. In this study, the behavior of spectral density of AE signal and principal cutting force signal in order to monitor the chatter vibration in the cutting process has been investigated. From the results, the reliability of proposed monitoring method has been confirmed.

  • PDF

New Permanent Magnet Synchronous Motor Current Sensing Phase Delay Compensation Method

  • Park, Sei-Hun;Kim, Il-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.241-246
    • /
    • 2016
  • This paper presents a method that can improve the performance of permanent magnet synchronous motor current control by minimizing the measured current phase delay caused by the Low Pass Filter(LPF) used to cut off the noises that flowed in when feedback currents are measured. Although existing methods that change the Cutoff Frequency of the LPF can minimize phase delays during high speed rotations, their noise cutoff effects are much lower and this may lead to the decline of control performance. Therefore, in this study, an algorithm that can compensate current phase delays through relatively simple calculations from the synchronous motor d-q axis coordinate transformation matrix and the inverse transformation matrix is proposed and the validity of the proposed method is verified by comparing the waveform of the calculated current with the waveform of actual currents through simulations and experiments.