• Title/Summary/Keyword: lead isotope

Search Result 89, Processing Time 0.043 seconds

Provenance and Metallurgical Study on Bronze Mirrors Excavated from Mireuksaji Temple Site, Iksan (익산 미륵사지 출토 동경의 금속학적 연구 및 산지 추정)

  • Huh, Il-Kwon;Cho, Nam-Chul;Kang, Hyung-Tae
    • Journal of Conservation Science
    • /
    • v.20
    • /
    • pp.23-30
    • /
    • 2007
  • By analyzing the chemical compositions of bronze mirror presumably excavated from Mireuksaji temple site, Iksan, we have surveyed what alloy composition was used in casting the mirror, and also tried to estimate the manufacturing technique of the bronze mirror, through the observation of microstructure, as well as which region$^{\circ}{\emptyset}s$ galena the lead used in the mirror belonged to, by analyzing the ratio of the lead isotope. The content analysis result of bronze mirrors shows that it consists of 68.8 to 73.3wt% of Cu, 21.6 to 24.9wt% of Sn. In particular, the content of Pb of Mireuk 2 and 3 Samples are higher than those of Miruk 4. The observation result of microstructure demonstrates that Mireuk 2 and 3 consist of ${\alpha}$ and ${\alpha}+{\delta}$ eutectoide phase made through casting process. But Mireuk 4 show other process employed, such as quenching though martensite structure. In the analysis result of provenance though the lead isotope ratio, the origin of the used in bronze millers excavated from Mireuksaji temple site is presumed to be from galenas of Japen, like this those, the chemical competition, microstructure, and lead isotope ratio of bronze mirrors excavated from Mireuksaji can be utilized at fundamental data to compare mutually with other remains.

  • PDF

Scientific Analysis and Provenance Study of Bronze Artifacts Excavated from Dongchon Site in Sunchang, Jeollabuk-do, Korea (전북 순창 동촌유적 출토 청동기의 원료 산지연구)

  • Bae, Go Woon;Chung, Kwang Yong
    • Journal of Conservation Science
    • /
    • v.32 no.2
    • /
    • pp.101-108
    • /
    • 2016
  • Lead isotope ratio of bronze artifacts excavated from Dongchon Site in Sunchang have determined by TIMS. As results of comparison lead isotope ratio of bronze objects with the provenance data of galenas of Korea, China, and Japan, the provenance of three material of bronze objects were turned out to originate from the southern and northern part of China. On the other hands, data were plotted either in zone 3 of the South Korean galena map. The results of these scientific analysis of bronze objects can be used as basic data in comparison researches on manufacturing technology, provenance of bronze objects to be found in the future.

Provenance Analysis of Horse-shaped Bronze Buckles Excavated from Site of Songjeol-dong, Cheongju (납동위원소비 분석을 활용한 청주 송절동유적 출토 마형대구의 원료산지 고찰)

  • Bae, Go Woon;Lee, Sang Ok;Chung, Kwang Yong;Shin, Seoung Chul
    • Journal of Conservation Science
    • /
    • v.35 no.3
    • /
    • pp.209-216
    • /
    • 2019
  • Lead isotope ratios in horse-shaped bronze buckles excavated from the Songjeol-dong site in Cheongju and the mid-western region of the Korean Peninsula have been determined by thermal ionization mass spectrometry. The lead isotope ratios of the samples with data provenance were plotted in zone 3 of the South Korean galena map. The results indicated that the horse-shaped bronze buckles could be made using galena located in the same area as the archaeological site. These results can be used as basic data for comparison purposes in future studies on the manufacturing technology and provenance of bronze artifacts.

Raw Material and Provenance of Chosen-Tongbo (I) (조선통보의 주조원료와 산지 연구(I))

  • Kang, Hyung Tae;Kim, Gyu Ho;Huh, Woo Young;Hirao, Yoshimitsu
    • Journal of Conservation Science
    • /
    • v.16 s.16
    • /
    • pp.15-20
    • /
    • 2004
  • Two pieces of choson-Tongue(朝鮮通寶) minted at 1423 A.D. were analyzed by atomic absorption spectroscopy and neutron activation analysis. The measurement of lead isotope ratios was also carried out in order to predict the provenance of raw materials used for minting. The Chosen-Tongue was minted as bronze having the chemical compositions of $Cu\;90\%,\;Pb\;3\~4\%,\;Sn\;2\~3\%$, which were different from the typical composition of Chinese and Japanese coins. The results of lead isotope ratios showed that the provenance of raw materials used for minting had a possibility to be originated from South China. And application of statistical linear discriminant analysis (SLDA) to the provenance of lead used for minting of Chosen-Tongue was confirmed.

  • PDF

Determination of Lead in Steels by Hydride generation-Inductively Coupled Plama/Mass Spectrometry (수소화물 발생-유도결합플라스마 질량분석법에 의한 철강 중의 납의 정량)

  • Park, Chang Joon;Song, Sun Jin;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.410-415
    • /
    • 2001
  • An analytical method has been developed which determines lead in steel samples by inductively coupled plasma mass spectrometry (ICP-MS) with sample introduction by the hydride generation. The lead hydride is not stable and requires and oxidant for the oxidation into metastable Pb(IV) before reduction to $PbH_4$ with $NaBH_4$. A study was carried out to find and optimum lead hydride generation condition for a sample solution with more than $1000{\mu}g/mL$ Fe matrix. $K_2Cr_2O_7$ was found to work as an efficient oxidant when more than $10{\mu}g/mL$ Fe matrix was present. Lactic acid was used with the oxidant as a complexing agent of the metastable Pb(IV) to enhance sensitivity. Optimum concentrations of the sample acidity, oxidant and lactic acid were different depending on the matrix concentration. The isotope dilution method was employed for the quantitation of lead. The determined Pb concentrations of the NIST steel SRM 361 and 362 were in good agreement with the certified values within the uncertainty range.

  • PDF

A study on the determination of lead in whole blood by ICP/MS (ICP/MS에 의한 전혈 중 납의 분석방법 연구)

  • Park, Kyung Su;Kim, Sun Tae
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.240-245
    • /
    • 1997
  • An accurate analysis method for the determination of lead in whole blood by ICP/MS was developed. Whole blood samples were decomposed in microwave digestion system without any contamination and loss of lead. The 96 samples were analyzed by ICP/MS using mass$^{208}$ isotope of lead. Lead concentrations of human whole blood were ranged of $2.50{\sim}22.8{\mu}g/dL$. The accuracy of this analysis method was verified by analyzing of NIST SRM 955a series(lead in blood).

  • PDF

Scientific Conservation and Analysis of Octagonal Green Glass Bottle Excavated from Tomb Hwayu princess (화유옹주묘 출토 녹유리장경각병-보존과 분석)

  • Gang, Hyeong-Tae;Yang, Pil-Seung;Heo, U-Yeong;Jo, Nam-Cheol
    • KOMUNHWA
    • /
    • no.70
    • /
    • pp.5-15
    • /
    • 2007
  • Octagonal green glass bottle with long neck(녹유리장경각병) was found in the tomb of the princess Hwayu who was King Youngjo's daughter by a concubine while the tomb was exhumed and buried in another place around Bucheon City, Gyeonggi-do. This octagonal glass bottle is dark green. It was made in AD 1736-A1795 because it was cngraved an inscription of "건륭년제" the bottom. This glass bottle was taken an X-ray radiography and tested adhesives and restoration materials for the conservation. Loctite 401 was suitable as considering the translucency of the glass bottle, good adhesive property and reversibility of the adhesive so it was chosen. A minute piece of the glass was analyzed the composition and lead isotope ratio. Major chemical composition of the glass bottle consisted of SiO2, K2O, and PbO system and the ratio was 68: 18.5:5.7. Green color of glass bottle was due to Fe2O3 and CuO. When the glass bottle was made, quartz as raw material of silica and K2O as natural saltpeter(KNO3) were utilized. As a result of lead isotope ratio analysis, it was suggested that the galena as raw material of lead for glass making came from the southern part of China. These results are expected to become useful data in background of glass culture and circulation study of old glass.

  • PDF