• Title/Summary/Keyword: lead free

Search Result 1,078, Processing Time 0.035 seconds

In Vivo Preperation of Standard Reference Materials of Lead in Blood (생체내 혈중 납 표준물질의 제조)

  • Chung, Kyou-Chull;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF

Piezoelectric Properties of Lead-free $Ba(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})TiO_3$ Ceramics for Haptic piezoelectric Actuator (햅틱 압전 액츄에이터용 $Ba(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})TiO_3$ 무면 세라믹스의 압전특성)

  • Park, Min-Ho;Lee, Kab-Soo;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.304-304
    • /
    • 2010
  • 최근 생활에 편리하며 휴대하기 좋은 전자기기들이 개발되고 있다. 휴대폰이나 MP3와 같은 전자기기들은 거의 필수품이라고 할 정도로 우리의 일상생활에 근접하여 있다. 그 종 대표적으로 휴대폰의 종류로 스마트폰과 같은 터치스크린을 이용한 사례는 점차 상승하고 있으며 시간이 지날수록 그 수요는 더욱 많아지고 있다. 때문에 몰입감 제공을 위하여 햅틱장치의 채용이 일반화 되고 있다. 햅틱장치란 가상환경이나 원거리에 있는 환경과 사용자가 상호 작용할 때 사용자에게 촉감이나 힘의 정보를 전달하여 주는 장치로 진동 및 회동 저항에 의해 사용자로 하여금 촉감들 느낄 수 있도록 하는 장치를 뜻한다. 즉, 현실감을 전달을 중점으로 하는 햅틱장치는 빠른 응답 속도와, 진동의 주파수와 크기는 독립적으로 제어가 가능해야 하며 기계적 수용기들을 직접적으로 자극할 수 있어야 한다. 하지만 모바일 햅틱장치의 경우 크기 및 소비전력의 문제로 모든 스펙을 만족하기에는 어려워 좀 더 한정적인 느낌을 제공할 수 없다. 현재까지 모바일 장치에서 햅틱 피드백을 위하여 진동모터나, 솔레노이드, 압전 액츄에이터 등이 많이 사용되어 지고 있다. 그 중 압전 액츄에이터는 입력에너지를 기계적 출력에너지로 변환되는 효과를 이용 한 것으로 압력 센서, 초음파 센서 등 많은 분야에서 응용되고 있으며 변위 범위는 작지만, 크기가 매우 작고 변위 정밀도가 높으며 발생력과 응답속도가 빠르다는 장점이 존재한다. 이를 이용한 햅틱 압전 엑츄에이터의 제작에 사용되는 압전 세라믹스는 높은 전기적 특성을 가질수록 더 졸은 효율을 가지며 이로 인하여 보다 좋은 전기적 특성을 가지는 압전 세라믹스를 필요로 한다. 현재 많이 사용되는 PZT계 세라믹스는 우수한 전기적 특성으로 많이 사용되고 있지만 Pb의 유독성으로 인한 환경문제로 Pb가 포함된 제품을 제한하고 있어 현재 Lead-free의 연구가 이루어지고 있다. Lead-free중 Ba$(Ti_{0.8}Zr_{0.2})O_3$(BZT)는 PZT계 세라믹스를 대체할 차세대 압전 재료로 주목받고 있다. 일반적으로 Lead-free의 압전계수($d_{33}$=100~300pC/N)는 비교적 낮은 값을 보이지만 BZT의 압전계수(BZT $d_{33}$~620pC/N)는 PZT계 세라믹스의 압전계수($d_{33}$=500~600pC/N)와 비교하여 부족하지 않은 압전계수를 보여주며 PZT를 대체할 재료로 주목받고 있다. 본 실험은 햅틱 압전 엑츄에이터용 무연 압전세라믹스의 제작을 위하여 Ba$(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})-TiO_3$(BZT -BCT)의 조성으로 유전 및 압전 특성을 조사하였다.

  • PDF

A Study on Work's Exposure to Dust, Crystalline Free Silica and Lead in Ceramic Industry (일부 요업사업장의 분진, 결정형 유리규산 및 납의 폭로에 관한 연구)

  • Oh, Se-Min;Shin, Yong-Chul;Park, Dong-Wook;Lee, Na-Roo;Park, Sueng-Hyun;Yi, Gwang-Yong;Moon, Young-Hahn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.168-179
    • /
    • 1994
  • In some ceramic industries, worker exposure to dust, crystalline free silica and lead were determined and evaluated. The conclusions are as follows. 1. Crystalline silica in bulk samples was 10.5 % in sanitary ware industry, 9.4 % in tile industry, and 2.1 % in ceramic insulator industry respectively. The free silica content of air filter sample was 8.03 % in table ware industry, 5.59 % in sanitary ware industry, and 1.32 % in ceramic insulator industry. Because silica content in ceramic dust is relatively high, it is should be considered silica as important factor in evaluating for ceramic industry. 2. The silica contents in dust from tile, sanitary ware and table ware industries are above 5%, it should be classified as "Type" 2 dust. 3. The airborne concentration of respirable crystalline silica was $27.9{\mu}g/m^3$ in a sanitary ware factory and $5.8{\mu}g/m^3$ in a ceramic insualtor factory. Three of ten samples sampled the above factories were exceeded the occupational exposure levels, $100{\mu}g/m^3$. 4. Geometric mean(GM) of total dust in 11 factories was $1.00mg/m^3$ and GM of respirable dust concentration in 5 factories was $0.33mg/m^3$. Sanitary ware industry had the highest concentration of total dust, $1.62mg/m^3$ and of respirable dust, $0.88mg/m^3$. 5. Average lead concentration in air was $0.05mg/m^3$ in glazing process of 2 factories manufacturing table ware. Five of ten sample(50%) were exceeded $0.05mg/m^3$. Therefore lead exposure in pottery industry should be considered as important problem.

  • PDF

Effect of Korean Traditional Tea Materials Water Extract on Hepatic Oxygen Free Radical Generating and Scavenging Enzyme Activities in Lead Administered Rats (한국전통차 재료의 열수추출물이 납투여 흰주의 간조직 중 유해 활성산소 생성과 제거효소 활성에 미치는 영향)

  • 김덕진;조수열;신경희;이미경;김명주
    • Journal of Nutrition and Health
    • /
    • v.36 no.2
    • /
    • pp.117-124
    • /
    • 2003
  • This study was designed to test the effect of Korean traditional tea materials on oxygen-free radical metabolism in lead (Pb) -administered rats. Male rats were divided into normal, Pb-control (Pb-Con) and Pb-water extract of green tea (Camellia sinensis; GT) , persimmon leaf (Diospyros kaki; PL) , safflower seed (Carhamus tinctorius: SS) , Du-Zhong (Eucommia ulmoides; EU) groups, respectively. Pb intoxication was induced by administration of lead acetate (25 mg/kg. B.W., oral) weekly. The extract was administered based on 1.26 g of raw material/kg B.W./day for 4 weeks. When the GT, PL, SS and EU were supplemented to the Pb-administered rats, hepatic lipid peroxide levels were significantly lower compared to the Pb-Con group. Hepatic cytochrom P-450 content and aminopyrine N-demethylase activity was lower in the Pb-Con group than in the normal group, whereas xanthine oxidase activity was significantly elevated in Pb-administered rats. The water extract of GT, PL, SS and EU supplementation attenuated changes in enzyme activities generating reactive oxygen species in the liver. Hepatic superoxide dismutase, catalase and glucose 6-phosphate dehydrogenase activities were significantly higher in the Pb-Con group than in the normal group, while monoamine oxidase activity also tended to increase in the Pb-administered rats. However, glutathione peroxidase and glutathione S-transferase activities, and glutathione content significantly decreased through Pb intoxication. The supplementation of GT, PL, SS and EU induced alleviation changes of hepatic antioxidant enzyme activity.

Electrodeposited Tin Properties & Their Effect on Component Finish Reliability

  • Fusco Phil;Schetty Rob
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.09a
    • /
    • pp.201-209
    • /
    • 2004
  • As the European Community's Directive on the Restriction of Hazardous Substances in Electrical and Electronic Equipment banning lead (Pb) in electronics products will take effect on July 1, 2006, most electronics manufacturers will be commencing with volume production of Pb-free components by the middle of 2004. Electrodeposited pure tin finishes on electronic components are a leading contender to replace the industry standard tin-lead. Commensurate with this shift will be a somewhat steep learning curve as manufacturers adapt a variety of equipment and processes to contend with the issues surrounding this critical, industry-wide material conversion. Since the electrodeposited finish directly influences the critical reliability characteristics of the component itself, the nature of the Pb-free component finish must be well characterized and understood. Only through a thorough examination of the attributes of the electroplated tin deposit can critical decisions be made regarding component finish reliability. This paper investigates the properties of electrodeposited tin that may have an effect on component reliability, namely, grain structure (size and shape), oxide formation, tin whisker formation, and solderability. Data will be presented from laboratory and production settings, with the objective being to enable manufacturers to draw their own conclusions regarding previously established perceptions and misconceptions about electrodeposited tin properties.

  • PDF

CuO첨가에 따른 $(Na,K)(Nb,Ta)O_3$ 세라믹스의 유전 및 압전 특성

  • Park, Min-Ho;Lee, Yu-Hyeong;Ryu, Ju-Hyeon;Hong, Jae-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.76-76
    • /
    • 2009
  • PZT세라믹스는 높은 압전특성과 우수한 큐리온도($400^{\circ}C$)를 보유하고 있어 오래시간에 걸쳐 주목받고 있다. 현재 압전변압기, 액츄에이터, 센서등의 압전소자는 PZT를 이용하여 제작하고 있지만 PZT는 고온 소결시 PbO의 휘발이 환경오염을 초래하며 인체의 유해하다는 연구결과가 나왔다. 이에 최근에는 PbO가 포함 되지않은 무연(lead-free)계 압전세라믹스가 주목받고 있다. 무연 압전 세라믹스의 종류로는 Bi-layer-structured ceramics, Bi-perovskite type ceramics, NKN base ceramics 가 존재하고 있다. 그 중 $(Na_{0.5}K_{0.5})NbO_3(NKN)$ 세라믹스는 높은 큐리온도와($400^{\circ}C$)와 높은 전기기계 결합계수(약 36%)를 보유하고 있어 많은 연구가 이루어 지고 있다. 하지만 NKN은 PZT에 비하여 치밀성이 낮으며 일반적인 산화물 소결방법으로는 밀도를 높이기가 어려운 단점이 존재한다. 이를 개선하기 위한 방법으로 hot pressing와 spak plasma sintering, RTGG와 같은 방법으로 밀도를 높일수 있지만 비용이 많이 들어 일반적으로 사용이 어렵다. 다른 방법으로 NKN에 첨가물을 넣는 방법을 사용하고 있는데 방법으로 $LiNbO_3$, $LiTiO_3$, $LiSbO_5$를 첨가하여 개선하는 방법이 있다. 본 실험은 첨가물을 넣는 방식으로 비화학양론적 $(Na_{0.5}K_{0.5})_{0.97}(Nb_{0.9}Ta_{0.1})O_3(NKNT)$조성에 CuO를 mol%로 변화주어 유전 및 압전 특성을 조사하였다.

  • PDF

Piezoelectric Properties of (K,Na)$NbO_3$ ceramics with the amount of KCN addition (KCN 첨가에 따른 (K,Na)$NbO_3$ 세라믹스의 압전특성)

  • Seo, Byeong-Ho;Sung, Kum-Hyun;Lee, Sang-Ho;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.188-189
    • /
    • 2009
  • In this study, in order to develop excellent lead-free composition ceramics for piezoelectric transformer, $(K_4CuNb_8O_{23})$ added $(K_{0.5}Na_{0.5})(Nb_{0.96}Sb_{0.04})O_3$ ceramics were fabricated using conventional mixed oxide method and their piezoelectric and dielectric properties were investigated as a function of the amount of KCN addition. With increasing the amount of KCN addition, density and mechanical quality factor(Qm), electromechanical coupling factor (Kp) were increased up to 1.2mol% and then decreased. At the 1.2mol% KCN added specimen, mechanical quality factor (Qm), electromechanical coupling factor (Kp), density and dielectric constant (${\varepsilon}r$) showed the optimal values of 781, 0.445, $4.42g/cm^3$ and 443, respectively, for piezoelectric transformer application.

  • PDF

Dielectric and piezoelectric properties of CuO added $(K_{0.5}Na_{0.5})_{0.97}(Nb_{0.96}Sb_{0.04})O_3$ ceramics (CuO첨가에 따른 $(K_{0.5}Na_{0.5})_{0.97}(Nb_{0.96}Sb_{0.04})O_3$세라믹스의 유전 및 압전 특성)

  • Lee, Yu-Hyong;Park, Min-Ho;Noh, Jung-Rae;Yoo, Ju-Hyun;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.160-161
    • /
    • 2009
  • In this study, in order to develop the lead free piezoelectric ceramics with excellent piezoelectric properties, (Na,K)$NbO_3$ ceramics according to the amount CuO addition were fabricated using a conventional mixed oxide process and their piezoelectric and dielectric characteristics were investigated. At the 0.8mol% CuO added composition, density, electromechanical coupling factor(kp), echanical quality factor(Qm), dielectric constant$(\varepsilon_r$) and piezoelectric constant($d_{33}$) showed the optimum value of $4.459g/cm^3$, 0.469, 540, 410, 69.57pC/N, respectively.

  • PDF