• 제목/요약/키워드: laser measuring system

검색결과 442건 처리시간 0.034초

레이저를 이용한 캠 프로파일 정밀 측정 장치 개발에 관한 연구 (A Study on the Development of High Precision Cam Profile Measuring System using Laser Interferometer)

  • 임상헌;이춘만;정종윤;윤상대;신상훈;신성우;황영국
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.267-268
    • /
    • 2006
  • Cam mechanisms are one of the most popular devices for generating irregular motion and are widely used in many industrial areas. The purpose of this study is the development of high precision measuring system fur measurement data acquisition and analysis of a manufactured cam profile. The developed system is composed of servo motor, CNC controller, rotary encoder, and laser interferometer And also, this system is non-contact measuring type. The developed system takes only 5 minutes to measure a cam profile and to analyze the measuring data while the CMM(coordinate measuring machine) takes about 1 hours even by a skilled operator.

  • PDF

영상 및 레이저 계측기를 통한 경사면 상황인식 시스템 (Recognition System of Slope Condition Using Image and Laser Measuring Instrument)

  • 한상훈;한영준
    • 대한임베디드공학회논문지
    • /
    • 제9권4호
    • /
    • pp.219-227
    • /
    • 2014
  • Natural disasters such as a ground collapse and a landslide have broken out due to the climate change of the Korea and the reckless expansion of cities and roads. The climate changes and the reckless urbanization have made the ground weak. Thus, it is important to keep a close eye on the highly weakened landslide and to prevent its natural disasters. In order to prevent these disasters, this paper presents a system of recognizing the road slide condition by measuring the displacements using laser scanner instrument. The previous system of monitoring the road slide has some problems as inaccurate recognition due to using only images from a camera, or expensive system such as artificial satellites and aircraft systems. To solve this problem, our proposed system uses the 3D range data from the laser scanner for measuring the accurate displacement of the road slide and optical flows from the Lucas-Kanade algorithm for recognizing the road slide in the image.

Enhancement of Tracking Performance of Laser Tracking System for Measuring Position Accuracy of Robots

  • Hwang, Sung-Ho;Choi, Gyeong-Rak;Lee, Ho-Gil;Shon, Woong-Hee;Kim, Jin-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.61.5-61
    • /
    • 2001
  • The laser tracking system(LTS) presents the most promising technique for dynamic position measurement of industrial robots. This system combine the advantage of high accuracy with a contactless measurement technique. It is the measurement system of position in three dimensions using distance data obtained by laser interferometer and real time angle by tracking mirror assembly. After measuring the tracking error of the beam projected on the center of retroreflector in robot end effector, this system tracks the end effector continuously by adjusting tracking mirror angle to minimize this error ...

  • PDF

레이저 검지기를 이용한 이동식 다차로 속도위반 알고리즘 연구 (A Study on Development of Mobile Multi-lane Speed Enforcement System With a Laser Detector)

  • 유성준;박진용
    • 한국안전학회지
    • /
    • 제32권4호
    • /
    • pp.114-121
    • /
    • 2017
  • In order to overcome the limitations of the mobile speed system for 1 lane, this study is used a multi-laser beam to develop a mobile speed measuring system, using a multi-phase beam. By using multi-laser beam, least squares algorithms and speed error processing algorithms were developed to improve speed accordancy and speed error rates compared to conventional mobile speed meters using a single laser beam. A field test showed that 80.0 percent of 3 lane and 87.0 percent of 4 lane were appropriate for the mobile speed system. With the development of the mobile speed measuring system, it is expected to dramatically reduce the accidents caused by the speed of traffic. It is also expected to effectively operate equipment and manage the cost by improving manpower and providing improved enforcement accuracy, by contributing positively to public institution and public affairs.

선형측정장치 개발 (Development of linear measuring system)

  • 엄태봉;김구영;정명세
    • 한국정밀공학회지
    • /
    • 제10권4호
    • /
    • pp.104-108
    • /
    • 1993
  • The linear length measurements are most frequently performed and should be most accurate among other parts in dimensional metrology. We developed the linear measuring system using a laser interferometer to improve the accuracy and to shorten the calibration time. The uncertainty of the system is 0.01 .mu. for 500mm steel gage block. The range of the measurement and resolution of the system are 1000mm and 0.01 .mu. m, respectively.

  • PDF

원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정 (A Study on the In-process Measurement of Metallic Surface roughness in Cylindrical Grinding by Diode Laser)

  • 김희남
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1995년도 춘계학술대회 논문집
    • /
    • pp.1-8
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens a detecting unit with polygon mirror and CCD array sensor. and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultanilusly monitor the state of the grind wheel. The experimental results, showed that the increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min. the feed rate is 0.2m/min-0.9m/min, the dressing speed is 0.2mm/rev-0.4mm/rev, the stylus method and the in-process method can be obtained the same results. thus under limited working conditions. using the proposed system. the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

원통연삭가공시 반도체 레이저 빔을 이용한 금속표면거칠기의 인프로세스 측정 (A Study on the In-Process Measurement of Metallic Surface Roughness in Cylindrical Grinding by Diode Laser)

  • 김희남;이주상
    • 한국안전학회지
    • /
    • 제10권3호
    • /
    • pp.30-41
    • /
    • 1995
  • This paper proposed a simple method for measuring surface roughness of ground surface. Utilizing non-contact in-process measuring system using the diode laser. The measurement system is consisted of a laser unit with a diode laser and a cylindrical lens, a detecting unit with polygon mirror and CCD array sensor, and a signal processing unit with a computer and device. During operation, this measuring system can provide information on surface roughness in the measuring distance with a single sampling and simultaniously monitor the state of the grind wheel. The experimental results, showed that the Increase of the feed rate and the dressing speed an caused increase in the surface roughness and when the surface roughness is 4Rmax-10Rmax, the cutting speed is 1653m/min-1665m/min, the table speed is 0.2n1/min -0.9m/min, the dressing speed is 0.2mm/rev~0.4mm/rev, the stylus method and the in-process method can be obtained the same results. Thus, under limited working conditions, using the proposed system, the surface roughness of the ground surface during cylindrical grinding can be obtained through the in-process measurement method using the diode laser.

  • PDF

포켈스 소자를 이용한 고전압 임펄스 및 미소신호 측정기술 개발 (Development of Measuring Techniques for High Voltage Impulse and Small Signals using Pockels Cell)

  • 홍진영;이정헌;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1571-1573
    • /
    • 1994
  • In order to substitute for the conventional measuring system which could bring about technical inconveiences, measuring techniques for the fast transient high voltage upto 100 kV and small signals less than 1 V are developed by use of Laser Source with Packets cell. for the former, capacitive voltage divider was specially designed for reducing the impulse voltage less than the half-wave voltage of pockets cell. For the tatter, interferometer type was employed as a mean to removing the fluctuation of Laser output intensity. And also the main beam through the Pockels cell and the reference beam from the Laser source are seperated before being detected respectively by photo diodes. And then, these two signals are amplified and compared for detecting only the small signals applied across the Pockels cell. Throughout this work, Laser-based measuring system is likely to enable us, at this moment, to detect correctly lightning impulse voltage upto 100 kV and the small signals less than 1 V upto the 2 MHz. Such a system could be employed as a possible diagnostic measuring system at the substation.

  • PDF

자동 표고 측정 장치 개발에 관한 연구 (A Study on the Development of the Automatic Level Measurement System)

  • 김종안;김수현;곽윤근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.756-760
    • /
    • 1997
  • In this research, the automatic level measurement system used in land leveling was developed. By using a laser transmitter and a receiver as measuring equipments, level was measured automatically. The driving part of this system was composed of stepping motor, timing belt and pulley. It drived the laser receiver to track laser beam generated form the laser transmitter. The level measuring experiments were performed about three level change shapes (step, random, sine). This system could measure step level change of which amplitude was 40mm in 0.5s, random level change within .+-. mm, maximum measurement error. In case of sine level change, experiment was executed with varying the spatial frequency of level change. As a result, this system was able to measure sine level change of which spatial frequency was 0.5m $^{-1}$ accurately.

  • PDF

레이저용접부 온도측정을 위한 적외선 온도측정장치의 개발에 관한 연구 (II) - 적외선 온도측정에서 제인자의 영향 - (A Study of the Infrared Temperature Sensing System far Measuring Surface Temperature in Laser Welding(II) - Effect of the System Parameter on Infrared Temperature Measurement -)

  • 이목영;김재웅
    • Journal of Welding and Joining
    • /
    • 제20권1호
    • /
    • pp.69-75
    • /
    • 2002
  • This study investigated the effect of the system parameters on penetration depth measurement using infrared temperature sensing system. The distance from focusing lens to detector was varied to diminish the error in measuring weld bead width. The effect of bead surface shape on measured surface temperature profile was evaluated using specimen heated by electric resistance. The measuring distance from laser beam was changed to optimize the measuring point. The results indicated that the monitoring device of surface temperature using infrared detector array was applicable to real time penetration depth control.