Evaluation of Muscle Tension in Hemiplegia Patients with a Real-time Monitoring System during High Intensity Laser Therapy

  • Lee, Sang-Kwan;Lee, Hyeong-O;Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • 제19권3호
    • /
    • pp.277-283
    • /
    • 2015
  • In this study, we evaluated the muscle tension in hemiplegia patients using a real-time monitoring system combined with high-intensity laser treatment (HILT) device. Five hemiplegia patients were treated with HILT in the left forearm muscle for 8 minutes, and the muscle was relaxed for 8 minutes following the treatment. Both the gradient of the force-displacement curves and the muscle hardness decreased during the therapy, and the effects were maintained following the treatment. The results show that muscle tension decreased rapidly during laser irradiation, and the efficacy of the treatment depended on the duration of the illness. Consequently, we conclude that this combined HILT and real-time muscle tension monitoring system is useful for evaluating the therapeutic procedure and for treatment of muscle pain.

입자 구형도에 따른 레이저 선가공의 비구형 흄 마이크로 입자 산포 특성 연구 (Dispersion Characteristics of Nonspherical Fume Micro-Particles in Laser Line Machining in Terms of Particle Sphericity)

  • 김경진;박중윤
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.1-6
    • /
    • 2022
  • This computational investigation of micro-sized particle dispersion concerns the fume particle contamination over target surface in high-precision laser line machining process of semiconductor and display device materials. Employing the random sampling based on probabilistic fume particle generation distributions, the effects of sphericity for nonspherical fume particles are analyzed for the fume particle dispersion and contamination near the laser machining line. The drag coefficient correlation for nonspherical particles in a low Reynolds number regime is selected and utilized for particle trajectory simulations after drag model validation. When compared to the corresponding results by the assumption of spherical fume particles, the sphericity of nonspherical fume particles show much less dispersion and contamination characteristics and it also significantly affects the particle removal rate in a suction air flow patterns.

대화면 FPS 게임을 위한 레이저센서기반의 대형스크린과 레이저광원 권총의 설계와 구현 (Laser-recognizable Screen and Gun with Laser Source for Realistic Big Screen First Person Shooters Games)

  • 한녹손;김성환
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2008년도 춘계학술발표대회
    • /
    • pp.481-484
    • /
    • 2008
  • In this paper, we present a new game interface design for First Person Shooters (FPS). Previously, FPS on computer is commonly played using keyboard/mouse or joystick along with PC display. We improve the communication environment between player and game world by means of new control system including large screen and laser gun, which create a real life-like space for players. Because traditional display for FPS uses CRT, it cannot support large screen display due to limitation of CRT technology. We designed and implemented a new input device using laser recognizable display. Results suggest that the combined interface creates a method which helps beginners to enjoy playing a FPS immediately and gives experienced players a new gaming experience.

펄스 레이저와 CFPI를 이용한 이종금속 접촉부의 이물질 측정에 관한 연구 (A Study on the Measurement of Foreign Material in Dissimilar Metal Contact Using Pulse Laser and Confocal Fabry-Perot Interferometer)

  • 홍경민;강영준;박락규
    • 비파괴검사학회지
    • /
    • 제33권2호
    • /
    • pp.160-164
    • /
    • 2013
  • 레이저 초음파검사 장치는 레이저 빔을 이용하여 초음파 신호를 발생시키고 측정하는 비접촉식 결함 검사 장치이다. 이 장치는 펄스 레이저 빔을 이용하여 광대역 주파수 범위를 갖는 초음파 신호를 발생시키고 작은 점으로 집속된 레이저 빔을 이용하여 초음파 신호를 측정하므로 우수한 측정 분해능을 제공한다. 본 연구에서는 이종금속 접촉부식(갈바닉 부식) 현상을 레이저를 이용한 비파괴, 비접촉 방법으로 측정하였다. 부식된 부분에 이물질이 혼합되는 경우를 가정하고, 레이저 초음파 실험을 진행하였다. 시편의 뒷면에서 펄스 레이저로 초음파를 발생시키고, 같은 위치의 앞면에서 CW 레이저와 CFPI를 이용하여 초음파 신호를 획득하였다. 이물질이 존재하는 부분의 초음파 신호 특성을 분석하여 이물질의 위치 및 크기를 측정하였다.

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

질환별 레이저 침의 임상적 효과 평가 : 체계적 문헌고찰 및 메타분석 (Evaluation of the Clinical Effectiveness of Laser Acupuncture for Disease Specific : Systematic Reviews and Meta-analyses)

  • 김대진;최병희;김태영;박수강;곽진영
    • 대한의용생체공학회:의공학회지
    • /
    • 제45권2호
    • /
    • pp.81-89
    • /
    • 2024
  • Purpose : This study conducted a systematic review and meta-analysis to evaluate the clinical effectiveness of laser acupuncture for each condition using information from laser acupuncture trials registered on clinicaltrials.gov from January 2013 to June 2023. Methods : We quantitatively and qualitatively analysed the results of 16 clinical trials of laser acupuncture whose research results were confirmed. A risk of bias assessment was also carried out to assess the quality of each clinical trial. Results : A meta-analysis including three clinical trials was conducted to evaluate the comparative effectiveness of laser acupuncture and sham laser acupuncture in reducing pain and found that the laser acupuncture group had a statistically significant reduction in pain compared with the sham laser acupuncture group. In addition, 11 of the 13 trials not included in the meta-analysis showed a positive effect of laser acupuncture. Conclusion : Although laser acupuncture has a long history of clinical use and a lot of research, there is still some scepticism due to the lack of a clear mechanism of action and inconsistent reports of clinical effectiveness. In addition, there is a significant lack of systematic reviews of clinical evidence for major disease specific, and ongoing research is needed to establish an objective evidence base for the clinical effectiveness of laser acupuncture.

반도체 광증폭기와 외부변조 기법을 이용한 전광 NOR 논리소자 (An All-Optical NOR Logic Device using a Semiconductor Optical Amplifier and an External Modulation Technique)

  • 변영태;김상혁;이석;김재헌;우덕하;김선호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.197-200
    • /
    • 2000
  • All-optical NOR logic device was realized by use of two pump signals with a single wavelength and a semiconductor optical amplifier(SOA). Specially, Mach-Zehnder(MZ) modulator was used for an external modulation of the pump signals. To obtain the sufficient gain saturation of the SOA, pump signals are amplified by an Er-doped fiber amplifier(EDFA) at the input of the SOA. Pump and probe signals are obtained from a DFB laser diode(${\lambda}_p$=1554 nm) and a tunable laser diode(${\lambda}_s$=1535 nm), respectively. The operation characteristics of the NOR logic device are successfully measured and demonstrated at the modulation frequency of 4.83 MHz.

  • PDF

스탠드간 장력프로파일을 이용한 열연판 평탄도 제어시스템 (Flatness Control System of the Hot Strip by Using Tension Profile between Stands)

  • 홍완기;이준정
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.27-36
    • /
    • 1999
  • To have high flatness quality of hot rolled strip in the hot strip finishing mill train, a new inter-stand tension profile measuring device of segmented looper roll type(coined as Flatness Sensing Inter-stand Looper, FlatSIL) and a new flatness control system have been developed in this study. The device measures the strip tension profile across the strip width and informs the strip wave pattern to new flatness control system where work roll bending mode to relieve the strip wave is determined. The existing automatic shape control system which uses laser type shape-meter installed at the outlet of the last finishing mill stand strip tension between down coiler and last finishig mill since the latent wave concealed by the strip tension between down coiler and last finishing mill stand cannot be measured by the laser distance-meter. Thus the existing shape control system is not able to control the flatness through the full strip length. The new flatness control system, however, works for full strip length during strip rolling as far as the tension profile measuring device and work roll bender are on. With the new flatness control system, work roll bender is automatically controller to minimize the latent wave of the running strip and the flatness quality as well as strip travelling stability has been noticeably improved from strip head through body to tail.

  • PDF

GaAs/AlGaAs Quantum Cascade Laser에서 Deep Mesa 구조에 의한 문턱전류 감소 (Threshold Current Reduction of GaAs/AlGaAs Quantum Cascade Laser due to the Deep Mesa Structure)

  • 한일기;송진동;이정일
    • 한국진공학회지
    • /
    • 제17권6호
    • /
    • pp.523-527
    • /
    • 2008
  • GaAs/AlGaAs 물질계를 기반으로 한 양자폭포레이저를 제작하였다. 양자폭포레이저는 활성층의 위까지만 식각된 shallow mesa 구조와 활성층까지 식각된 deep mesa 구조로 제작되었다. shallow mesa 구조의 경우 문턱전류 밀도가 $26-32\;kA/cm^2$이었지만 deep mesa 구조의 경우 문턱전류 밀도는 $13\;kA/cm^2$로 대단히 감소되었다. Deep mesa 구조에서의 문턱전류 감소는 측면 방향으로의 전류 손실이 감소되었기 때문으로 설명되었다.