• Title/Summary/Keyword: laser dentistry

Search Result 573, Processing Time 0.039 seconds

Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits

  • Park, Eun Young;Sohn, Hae Ok;Kim, Eun-Kyong
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.1
    • /
    • pp.43-49
    • /
    • 2019
  • Background: In the osseointegration of dental implants, the implant surface properties have been reported to be some of the most important critical factors. The effect of implant's surfaces created by resorbable blast media (RBM) followed by laser ablation on bone tissue reactions was examined using the removal torque test and histomorphometric analysis. Methods: Two types of dental implants, RBM-laser implants (experimental group) and RBM implants (control group) (CSM implant system, Daegu, Korea; L=6 mm, diameter=3.75 mm) were placed into the right and left distal femoral metaphysis of 17 adult rabbits. Six weeks after placement, removal torque was measured and histomorphometric analysis was performed. Results: The mean removal torque was $24.0{\pm}10.2Ncm$ and $46.6{\pm}16.4Ncm$ for the control and test specimens, respectively. The experimental RBM-laser implants had significantly higher removal torque values than the control RBM implants (p=0.013). The mean values of total and cortical bone to implant contact (BIC) were respectively $46.3{\pm}10.8%$ and $65.3{\pm}12.5%$ for the experimental group, and $41.9{\pm}18.5%$ and $57.6{\pm}10.6%$ for the control group. The experimental RBM-laser implants showed a higher degree of total and cortical BIC compared with RBM implants, but there was no statistical significance (p=0.482, 0.225). Conclusion: The removal torque and BIC of the test group were higher than those of the control group. In this study, the surface treatment created by RBM treatment followed by laser ablation appears to have a potential in improving bone tissue reactions of dental implants.

A Case Report of Stevens-Johnson Syndrome with Intraoral Lesions (구강 증상을 동반한 Stevens-Johnson 증후군의 임상 증례)

  • Kim, K.A.;Jang, S.Y.;Ryu, S.S.;Byun, Y.H.;Lee, J.M.;Lee, C.H.;Kee, W.C.;Choi, J.K.
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.23-29
    • /
    • 1997
  • A 49 years old male patient was referred from the Department of Medicine, KNUH for the management of painful oral lesions. The patient had disability of food and drug intake due to multiple intraoral ulcers. Extraoral findings showed upper and lower lip swelling, crust formation on the lips. The lesions were diagnosed as Stevens-Johnson syndrome based on clinical and hematologic findings. The patient was treated with saline irrigation and pulsed Nd:YAG laser irradiation. After 5 daily treatment, the lesions decreased in size and severity, and the patient became more comfortable for food intake and speeching. It was suggested from the results of this clinical trial that a pulsed Nd:YAG laser therapy would be helpful for the symptoms associated with Stevens-Johnson syndrome.

  • PDF

A STUDY OF THE EFFECTS OF THE LOW POWER DENSITY LASER ON THE MECHANICALLY EXPOSED PULP (저출력 레이저가 기계적 노출치수에 미치는 영향에 관한 연구)

  • Park, Dong-Sung;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.109-118
    • /
    • 1989
  • The purpose of this study was to investigate the bio-stimulating effect of low power density laser radiation on the mechanically exposed pulp. Class V cavities on dog's teeth were prepared and the pulps were mechanically exposed with a round bur. In control group, the exposed pulps were capped with $Ca(OH)_2$ powder and the cavities were sealed with Z.O.E.. In experimental group A, the pulps were irradiated with GaA1As laser for 5 minutes and then they were treated the same as control group. In experimental group B, the exposed pulps were covered by aluminum foil and sealed with Z.O.E. after they were irradiated with the laser as the experimental group A. In the all groups, the pulps were histopathologically observed at the time intervals of 1, 2 and 3 week after experiment and the results were statistically evaluated. The results were as follows: 1) In control and experimental groups, mild vascular congestion and bleeding was found in most of the specimens and for the new formation of dentin bridge, experimental group A had the most cases. The dentin bridge had discontinuous osteodentin like appearance without any dentinal tubules. Inflammatory cell infiltration consisted of acute and chronic inflammatory cell, and the formation of microabscess was also observed. 2) The degree of inflammatory cell infiltration was not significantly different among control group and experimental groups at 1 week, 2 week and 3 week. 3) The formation of new dentin bridge was not significantly different between control group and experimental group A at 1 week, but at 2 week and 3 week, experimental group A showed significantly more cases of new dentin formation than control groups. (P < 0.05). 4) Between control group and experimental group B, there was no significant difference in formation of the new dentin bridge at 1, 2 and 3 week. (P> 0.05). 5) There was no significant difference in formation of the new dentin bridge at 1 and 2 week between experimental group A and experimental group B, but at 3 week, the former significantly had more cases of new dentin bridge formation than the latter.(P < 0.05).

  • PDF

THE MICROHARDNESS OF RESTORATIVE COMPOSITE AND DUAL-CURED COMPOSITE CEMENT UNDER THE PRECURED COMPOSITE OVERLAY (아르곤레이저를 이용한 레진인레이 하부의 레진 시멘트 및 광중합형 복합레진 중합)

  • Park, Sung-Ho;Lee, Chang-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.109-115
    • /
    • 2000
  • This study was designed to evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay. For restorative materials, Z100 and Tetric Ceram were used. For dual cured composite cements, Variolink II((VL II) of three consistency (low, high, ultra high) were used. To determine the optimal microhardness of Z100, Tetric Ceram and Variolink II, each material was packed into the 1mm thickness teflon mold without composite overlay and light cured for 60 seconds. Then the microhardnesses of each sample were measured, averaged and regarded as optimal hardness of each material. To evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay, the composites were packed into 1mm thickness teflon mold, coverd with celluloid strip, and then precured composite overlay which was made of Targis(Ivoclar/Vivadent, Liechtenstein) was positioned. 2 types of visible light curing machine, the power density of one of which was 400$mW/cm^2$ and the other was 900$mW/cm^2$, and one type of argon laser were used to cure the restorative composite and dual cured cement. For each group, 10 sample were assigned. The light curing tip was positioned over the composite overlay and light cured for 1min., 2min. or 3min with visible light curing machine or 15sec, 30 sec, 45sec, and 60 sec with argon laser. The Vickers hardnesses of upper and lower surface of Z100, Tetric Ceram, and 3 types of VL II cement were measured. When the 900 $mW/cm^2$ curing light was used, 2min. was needed for optimal curing of Z100 and Tetric Ceram. Variolink II did not be cured optimally even though the curing time was extended to 3min. When 400$mW/cm^2$ curing light was used, 3min. was necessary for Z100, whereas 3min. was not enough for Tetric Ceram. Variolink II was not cured optimally even though the curing time was extended to 3min. When argon laser was used, Z100, Tetric Ceram and Variolink II were not cured optimally in 60 seconds.

  • PDF

Effects of resolution of inflammation for low-power $CO_2$ laser treatment on gingivitis patients (치은염 환자에서 저출력 이산화탄소 레이저의 염증완화 효과에 관한 연구)

  • Song, Hyun-Jong;Kim, Byung-Ock;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.657-668
    • /
    • 2008
  • Purpose: In this study, we compared low-power $CO_2$ laser treatment to ultrasonic scaling, which is generally approved as a power-driven mechanical instrumentation, and evaluated both of these treatments regarding their clinical effectiveness and change in the volume of in GCF. Material and methods: 20 patients who had gingivitis were selected. all of patients has no systemic problems. Randomly selected, one quadrant received ultrasonic scaling only, another quadrant received ultrasonic scaling and $CO_2$ laser irradiation, the other quadrant received $CO_2$ laser irradiation only. Clinical parameters measured at baseline, 1 weeks, 2weeks, 4weeks and 8weeks. Result: Pocket probing depth and clinical attachment level were not changed during study period. Gingival index of all group were improved after treatment. At 1 weeks after treatment, Gingival index of ultrasonic scaling group was only significantly different compared to control group. At 2 weeks after treatment, gingival index of all experimental group were significantly different compared to control group. At 4 and 8 weeks after treatment, gingival index of all group were increased, but experimental group were lower than control group. Sulcus bleeding index was similar to the results of gingival index. At 1 weeks after treatment, all experimental group were significantly different compared to control group and it maintained during study. At 2 weeks after treatment, sulcus bleeding index of all group were lowest during study. Gingival crevicular fluid were measured with $Periotron^{(R)}$ 8000($Oraflow^{(R)}$, Inc. USA). At baseline, all group were showed moderately severe condition. At 1 week after treatment, laser treatment only group was reduced quantity of gingival crevicular fluid mostly, and all group were reduced quantity of gingival crevicular fluid. At 2 weeks after treatment, all group were health state. At 4 and 8 weeks after treatment, all group were showed recurrent of inflammation, and control group was the most significantly increased. Conclusion: This study showed that the effects of $CO_2$ laser treatment were similar to conventional ultrasonic scaling and this result remained longer than plaque control only. These results suggest possibility of $CO_2$ laser treatment for altered periodontal therapy.

Detection of laser doppler blood flow signal from human teeth

  • Ikawa, M.;Iiyama, M.;Shimauchi, H.
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.546.1-546
    • /
    • 2003
  • Laser doppler flowmeter (LDF) has been applied to the measurement of pulpal blood flow (PBF) in human teeth. As far as we searched, the detection area of the pulp in the blood flow measurement has not been clarified, yet. Therefore, the purpose of this study was to obtain information of the detection area in PBF measurement using LDF. The experiments were performed on the artificial blood circulation in extracted human upper central incisors. The apical portions of examined teeth (n=6) were severed and root canals were enlarged from the apical end to the 2mm incisal to the level of enamel-cement junction. An individual resin cap of each tooth was prepared and a hole was drilled 2mm incisal to enamel-cement junction of the labial side of the cap. The measurement probe of LDF (MBF3D, Moor Instrument, UK) was plugged into the hole of the cap. Heparinized human peripheral blood, which was in advance collected and diluted 3 times with physiological saline, was pumped through the apical foramen of the teeth via a silicone tube and a disposable needle (o.d. 0.7mm) and blood flow signals were monitored. The flux signal significantly increased with the enlargement of the root canal to incisal direction (p<0.01, Friedman analysis). The result indicates that the performance of LDF in PBF with human teeth is limited.

  • PDF

Streptococcus Mutans Biofilm Inhibition Effect of Indocyanine Green and Near Infrared Diode Laser (Indocyanine Green과 근적외선 다이오드 레이저의 Streptococcus mutans 세균막에 대한 억제 효과)

  • Kim, Yeowon;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.446-453
    • /
    • 2020
  • The purpose of this study was to evaluate the effect of Indocyanine Green (ICG) and near-infrared (NIR) diode laser on Streptococcus mutans biofilms depending on ICG concentrations. S. mutans biofilms were formed on a Hydroxyapatite disk, and 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solutions dissolved in sterile distilled water and a NIR diode laser having a power of 300 mW and a wavelength of 808 nm were applied to the biofilms. The temperature changes of the biofilm surface according to the concentrations of the ICG solution were measured using a 1-channel thermocouple thermometer. Compared to the control group, in the groups with only the 3.0, 4.0, 5.0 mg/mL ICG solution application, and in the groups with the 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solution application and light irradiation, a statistically significant decrease in the bacterial counts were observed. The temperature increase according to the concentration of the ICG solutions was 9.53℃, 10.43℃, 11.40℃, 12.10℃, 12.67℃, and 13.63℃ in ICG solutions of 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mg/mL respectively. This study presents the potential for clinical application of ICG and NIR diode lasers as a new method for preventing dental caries.

FATIGUE RESISTANCE OF DENTAL IMPLANTS TREATED WITH LASER METHOD

  • Park, Eun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.734-739
    • /
    • 2006
  • Statement of problem. Many surface processing methods of dental implant have been developed, the laser processing is one of them. Purpose. This study was to investigate in vitro the fatigue resistance of implants treated with laser method(CSM implant, CSM Company, Daegu, Korea). Material and methods. Fatigue tests of 23 laser treated CSM implant(CSM Company, Daegu, Korea) were conducted using Instron 8871 (Load cell, 5 kN, Instron Co., England), according to ISO 14801 (2003), Results. From 300 N, each specimens were not fractured and withstood until more than 5,000,000 cycle. Conclusion. Within the limits of this in vitro study, implants treated with laser method (CSM implant, CSM Company, Daegu, Korea) have had enough rigidity and fatigue resistance to use clinically with reliance.

EFFECT OF LOW LEVEL LASER THERAPY ON HEALING OF OPEN SKIN WOUNDS IN RATS (백서 연조직에 저수준 레이저 요법시 창상 치유기전에 관한 연구)

  • You, Sang-Woo;Kim, Kyung-Wook;Lee, Jae-Hoon;Kim, Chang-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.481-489
    • /
    • 2000
  • This research was focused on overall examination of tissue alteration, wound healing promotion. After the hair on the dorsal surface was shaved, $5{\times}5mm$ oval skin defect was formed. Experimental wounds of right side were irradiated on every day for 90 second with Ga-Al-As semi-conductor laser. Left side wounds served as control group. The rats were sacrificed on the 1st, 3rd, 5th, 7th, 14th, 21th day. For light microscopically, parafin section were stained with H&E, MT. The outcomes were as follows : 1. On 1st day, experimental and control group were seen acute inflammatory cell infiltration, edema. 2. On the 3rd days, both groups were seen crust development, collagen, blood vessel proliferation. 3. On the 5th days, experimental group were reduced edema and inflammatory cell infiltration than control group. 4. On the 7th days, both groups were observed edema, inflammatory cell infiltration disappearance and keratinocytes motility from wound defect. 5. On the 14th days, experimental group appeared collagen, blood vessel proliferation and hair follicle than control group. 6. On the 21th days, both groups were seen normal status re-epithelization. According to the above results, The wound-healing stimulated by laser radiation involves an increased rate of epithelial growth. LLLT was confirmed that it has fibroblast, blood vessel proliferation, influence initial wound healing process.

  • PDF

In vivo evaluation of infrared LASER mediated drug release of PLA-tetracycline complexes coated gold nanoparticle-titania nanotubes with mouse (마우스를 이용한 PLA - tetracycline 복합체 코팅 금 나노입자 - 티타니아 나노튜브의 적외선 레이저 유도 약물용출 생체 내 평가)

  • Moon, Kyung-Suk;Jeoung, Chan-Gwoun;Bae, Ji-Myung;Oh, Seunghan
    • Korean Journal of Dental Materials
    • /
    • v.44 no.1
    • /
    • pp.33-41
    • /
    • 2017
  • In this study, we prepared PLA-tetracycline complexes coated gold nanoparticle-titania nanotubes and estimated their infrared LASER mediated drug release in the abdominal region of ICR mouse. The results of UV-Vis spectrophotometer showed the highest absorbance at the wavelength of 530 nm and 809 nm indicating the existence of gold nanoparticles. EDX analysis showed that the amounts of gold nanoparticle coated on titania nanotubes were approximately 3.62-36.5 wt%. In vivo test resulted that the tetracycline release value of experimental groups (6.5 ng/mL) was higher than that of control group (5.8 ng/mL) on the condition of 30 minutes of LASER irradiation. Therefore, it is expected that PLA-tetracycline complexes coated gold nanoparticle-titania nanotubes have the feasibility in the field of infrared remote controlled drug device and overcome the limitation of location and time of drug release in dental implant.