• Title/Summary/Keyword: large-scale test

Search Result 1,426, Processing Time 0.032 seconds

Earthquake Response Analysis of A Large Scale Seismic Test Structure (대형지진시험구조물의 지진응답해석)

  • Yun, Chung-Band;Park, Kyoung-Lae;Kim, Jae-Min
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.107-113
    • /
    • 1995
  • This paper presents the earthquake response analysis results on the Large-Scale Seismic Test (LSST)structure which was built at Hualien in Taiwan. The seismic analysis is carried out using a computer code KIESSI, which has been developed based on the three-dimensional axisymmetric finite element method incorporating infinite elements for the far field soil region. The soil and structural properties obtained from the post-correlation study of the forced vibration tests (FVT) are utilized to predict seismic responses. The ground accelerations recorded at a site 56.5 m from the test structure are used as control motions. It has been found that the predicted responses are reasonably compared with the observed responses.

  • PDF

A Large Scale Smart-Grid field-test in Jeju (제주 Smart-Grid 대규모 실증단지 구축 현황)

  • NamKoong, Won;Ha, Bok-Nam;Lee, Sung-Woo;Seo, In-Yong;Jang, Moon-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Five smart grid projects was started with large scale at Jeju Island in South Korea from 2009, and smart-grid test-bed was started in Nov. 2010. The five projects are Smart Power Grid (SPG), Smart Renewable (SR), Smart Transportation (ST), Smart Place (SP) and Smart Electric Service (SES). Korea government constructed the smart grid public relations center at Nov. 2010 in Jeju Island and there will be continued the field operation and interface testing among five smart gird projects until May. 2013.

ROSA/LSTF test and RELAP5 code analyses on PWR steam generator tube rupture accident with recovery actions

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.981-988
    • /
    • 2018
  • An experiment was performed for the OECD/NEA ROSA-2 Project with the large-scale test facility (LSTF), which simulated a steam generator tube rupture (SGTR) accident due to a double-ended guillotine break of one of steam generator (SG) U-tubes with operator recovery actions in a pressurized water reactor. The relief valve of broken SG opened three times after the start of intact SG secondary-side depressurization as the recovery action. Multi-dimensional phenomena specific to the SGTR accident appeared such as significant thermal stratification in a cold leg in broken loop especially during the operation of high-pressure injection (HPI) system. The RELAP5/MOD3.3 code overpredicted the broken SG secondary-side pressure after the start of the intact SG secondary-side depressurization, and failed to calculate the cold leg fluid temperature in broken loop. The combination of the number of the ruptured SG tubes and the HPI system operation difference was found to significantly affect the primary and SG secondary-side pressures through sensitivity analyses with the RELAP5 code.

Large scale fire test on a composite slim-floor system

  • Bailey, C.G.
    • Steel and Composite Structures
    • /
    • v.3 no.3
    • /
    • pp.153-168
    • /
    • 2003
  • This paper discusses the results and observations from a large-scale fire test conducted on a slim floor system, comprising asymmetric beams, rectangular hollow section beams and a composite floor slab. The structure was subjected to a fire where the fire load (combustible material) was higher that that found in typical office buildings and the ventilation area was artificially controlled during the test. Although the fire behaviour was not realistic it was designed to follow as closely as possible the time-temperature response used in standard fire tests, which are used to assess individual structural members and forms the bases of current fire design methods. The presented test results are limited, due to the malfunction of the instrumentation measuring the atmosphere and member temperatures. The lack of test data hinders the presentation of definitive conclusions. However, the available data, together with observations from the test, provides for the first time a useful insight into the behaviour of the slim floor system in its entirety. Analysis of the test results show that the behaviour of the beam-to-column connections had a significant impact on the overall structural response of the system, particularly when the end-plate of one of the connections fractured, during the fire.

Bipolar Membranes and Their Applications

  • Strathmann, H.
    • Membrane Journal
    • /
    • v.11 no.3
    • /
    • pp.97-108
    • /
    • 2001
  • Bipolar membranes have gained increasing interest as a tool for an efficient production of acids and bases from the corresponding salts. A large number of potential applications have been identified in the chemical and biochemical industry have been identified and evaluated on a laboratory scale. In spite of extensive research efforts and laboratory and pilot plat test, there are hardly any large-scale commercial plants. In this paper the basic concept of the electrodialytic water dissociation with bipolar membranes are briefly reviewed. The limitations of today\`s bipolar membranes are indicated. Selected examples of successful applications of the bipolar membrane technology are discussed.

  • PDF

Quasi Static Test of Lap Spliced Shear-Flexure RC Piers Using Real Scale Models (주철근 겹침이음된 휨-전단 RC교각의 실물모형 준정적 실험)

  • 곽임종;조창백;조정래;김영진;김병석
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.203-210
    • /
    • 2002
  • The past bridge design specifications of Korea didn't include 1imitation on the amount of lap splices in the plastic hinge zone of piers, and so do current specifications. But these specifications include just limitation on the minimal length of lap splices. Thus, a large majority of non-seismically designed bridge piers may have lap splices in plastic hinge zone. In this study, model pier was selected among existent bridge piers whose failure mode is complex shear-flexure mode. Full scaled RC pier models whose aspect ratio is about 2.67 were constructed and quasi static test according to the drift level history was implemented. From the test results, effect of the lap splices on the seismic performance of bridges piers was analyzed, and the seismic capacity of the model bridges was evaluated by capacity spectrum method.

  • PDF

Behavior of Geotextile Tube by Numerical Analysis (수치해석기법을 이용한 지오텍스타일 튜브의 거동분석)

  • 신은철;오영인;조인휘
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.385-392
    • /
    • 2003
  • Traditional forms of river and coastal structures have become very expensive to build and maintain, because of the shortage of natural rock. Geotextile tubes hydraulically or mechanically filled with dredged materials have been applied in hydraulic and coastal engineering in recent years(shore protection structure, detached breakwater, groins and jetty). Recently, new preliminary design criteria supported by model and prototype tests, and some stability analysis calculations have been studied. In this study, the numerical analysis was performed to investigate the behavior of geotextile tube with various properties of geotextile and hydraulic pumping conditions. Numerical analysis was executed to compare with the results from the large-scale field model tests, and also compared the results of 2-D plane strain analysis and 3-D FEM analysis. A geotextile tube was modeled using the commercial finite element analysis program ABAQUS and the one-quarter of tube was modeled. Behavior of geotextile tube during the hydraulic pumping procedure was analyzed by comparing the large-scale field model test and numerical analysis. The shape variation and maximum tube height between the numerical analysis results and large-scale filed test results are turned out to be a good agreement.

  • PDF

Study on the Computational Simulation of Large Scale Gap Test (Large Scale Gap 시험의 전산모사연구)

  • Lee, Jin-Sung;Park, Jung-Su;Lee, Young-Shin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.932-940
    • /
    • 2011
  • This study describes computational simulation results in 2-dimensional and 3-dimensional space concerning large scale gap test(LSGT) by using commercial hydrocode such as AUTODYN and LS-DYNA to analyze the detonation phenomenons of high explosives. To consider the possibilities of LSGT simulation, we used Lee - Tarver reaction rate model of PBX-9404 and Comp-B which were implemented AUTODYN's material library. Also we have tried the diverse numerical schemes such as Lagrangian, Eulerian and ALE(Arbitary Lagrangian Eulerian), SPH(Smoothed Particle Hydrodynamics) in LSGT simulations. After LSGT simulations, we compared the simulation results with published results to verify the LSGT simulations. According to the LSGT simulations, we have concluded as follows. In 2-dimensional and 3-dimensional space, Lagrangian solver provided the most reliable results based on analysis time and accuracy. When using two hydrocodes in 2-dimensional space, the simulation results are almost same except one explosive model. We have verified the modeling method and simulation results of the LSGT by using the commenrcial hydrocode in this study.

Field Performance Test of Unit Platform Development for Offshore Floating Photovoltaic Power Structure (부유식 해상태양광 발전을 위한 단위 플랫폼 구조물의 실해역 성능평가)

  • Na, Kyoung Won;Choo, JinHun;Lee, Byung Jun
    • New & Renewable Energy
    • /
    • v.17 no.3
    • /
    • pp.16-23
    • /
    • 2021
  • Recently, the Korean government announced a plan to activate renewable energies, with focus on clean energy sources such as solar and wind power as the core and the goal of achieving carbon neutrality by 2050. Unlike other photovoltaic (PV) systems, offshore PV installations are advantageous for large-scale expansion because of the ease of securing sites; they also enable lowering the power generation costs based on construction of large-scale power facilities of megawatt class or higher owing to low noise and landscape damage. However, any power generation should proceed with consideration of the special environmental conditions of the ocean. Above all, when installing large-scale facilities, it is important to reduce fluctuations of the structure and secure stability to actively respond to waves. This study is concerned with the development of a floating body technology that actively responds to waves so as to enable commercialization of offshore solar power. A unit platform for research and development on offshore PV generation was installed in the Saemangeum sea, and the structural fluctuations and stability were analyzed to ensure conformity with the major performance indicators.